MAURY USCG vessel records Sign in
← All vessels

MS JUDITH

MS JUDITH is a 1983 passenger vessel (inspected). The Coast Guard has recorded 50 inspections since 1983, most recently in October 2010, along with 39 deficiencies.

Records from 1983 to 2010. Most recent: inspection, 7 October 2010.

Built
1983
Last inspected
7 October 2010
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDD8438
228661
Flag
UNITED STATES
367199160 (licence lapsed)
Maury page id
psix-228661

Inspections, by type

…with no type recorded7
Years with a record 27 calendar years (1983–2010)
The 50 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it67 - Regulatory (Subpart C or D), Net Ton
99 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDD8438MMSI 367199160 · expired · compulsorily equipped · granted 22 June 2007, cancelled 26 August 2017
WRC6556MMSI not assigned · expired · compulsorily equipped · granted 4 August 1998, cancelled 3 January 2009 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 50

7 October 2010 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3865452
21 August 2008 Internal Structural Exam · Annual Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3305867
8 February 2008 Examination of Repairs · Damage Survey
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3143983
12 September 2007 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3057377
25 July 2007 COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3006845
10 June 2007 Administrative Inspection
Administrative · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2956907
15 September 2006 Re-Inspection · MTSA Verification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2779344
14 September 2005 Re-Inspection · Ballast Water Examination · Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2492349
17 December 2004 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2261661
8 October 2004 Annual Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2203281
17 October 2003 Re-Inspection · Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1929117
22 September 2003 Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1903364
31 July 2003 Drydock Extension
Administrative · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 1866155
9 January 2003 Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1728013
12 July 2002 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1644671
7 May 2002 Type not recorded
No type recorded · USCGC KEY BISCAYNE (WPB 1339) · USCG Southeast District (CGD-SE) · Activity 1615004
1 August 2001 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1070767
1 August 2001 Hull Examination · Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1461433
12 October 2000 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1057218
14 September 2000 Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1415448
29 July 1999 Hull Examination · COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1466063
4 March 1999 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 800976
29 January 1999 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 790106
8 October 1998 Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1413418
3 August 1998 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 39407
25 July 1997 Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1434596
13 August 1996 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1427248
14 August 1995 COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1456294
19 September 1994 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1459898
5 August 1994 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1455181
8 October 1993 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 827122
30 August 1993 Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 825873
6 August 1993 Hull Examination · COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1157637
23 September 1992 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1259810
2 April 1992 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 951843
30 March 1992 Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 953663
26 September 1991 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 933573
28 September 1990 Hull Examination · COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 932084
1 November 1989 COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1282352
8 March 1989 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 892559
3 November 1988 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1208059
14 June 1988 Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 893748
3 November 1987 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1328969
3 November 1986 COI Inspection · Hull Examination
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1016303
18 February 1986 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1302996
6 June 1985 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 979908
17 December 1984 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 980826
12 April 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1281215
20 January 1984 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 971690
20 December 1983 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1280123

Deficiency record · 39

Stability › Watertight Integrity › General
Issued 7 October 2010 Resolved
Remove and replace in appropriate vent closing devices.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 October 2010
Fire Fighting › Portable CO2 Fire Extinguisher › Number
Issued 7 October 2010 Resolved
Provide appropriate number/type portable extinguishers as per COI.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 October 2010
Stability › Watertight Integrity › General
Issued 7 October 2010 Resolved
Make watertight bulkhead penetrations watertight.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 October 2010
Electrical › Electric Supply System (service) › Cable
Issued 7 October 2010 Resolved
Remove/replace exposed 12V wire to VHF Radio
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 October 2010
Stability › Watertight Integrity › General
Issued 7 October 2010 Resolved
make appropriate adjustments to watertight doors to make watertight.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 October 2010
Documentation › Manuals/Policy Documentation › Transfer Procedures
Issued 25 July 2007 Resolved
Provide a copy of proper fuel transfer procedures and have readily available onboard vsl.
Due 1 August 2007
Resolved 31 August 2007
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 25 July 2007 Resolved
Provide and post EAP information as required.
Due 1 August 2007
Resolved 31 July 2007
Communications › Radio Communications › EPIRB
Issued 25 July 2007 Resolved
Provide proof of registration of EPIRB with current vsl's name and post decal as required.
Due 1 August 2007
Resolved 31 July 2007
Operations/Management › Ballast Water Managment › Mandatory Practices
Issued 14 September 2005 Resolved
Provide BWM plan IAW 33 CFR 151.2035
Action required: 705 - Other - as specified
Due 13 October 2005
Resolved 15 September 2006
Resolution: Vsl does not use ballast water, so they do not need a BWM plan.
Personnel › Certificates/Documents/Licenses › Certificate, CPR Course Completion
Issued 8 October 2004 Resolved
Provide first aid and CPR certification documentation.
Action required: 705 - Other - as specified
Due 8 November 2004
Resolved 17 December 2004
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 8 October 2004 Resolved
Repaint vessel name and hailing port.
Action required: 705 - Other - as specified
Due 8 November 2004
Resolved 17 December 2004
Lifesaving › Buoyant Apparatus
Issued 17 October 2003 Resolved
MAKE ALL LIFEFLOATS FLOAT FREE.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 October 2003
Fire Fighting › Fire Pumps
Issued 17 October 2003 Resolved
RENEW FIRE PUMP PRESSURE GUAGE.
Condition: Unknown
Due 24 October 2003
Resolved 27 October 2003
Lifesaving › Lifejacket/PFD (General)
Issued 17 October 2003 Resolved
RENEW ALL WASTED RETRO-REFLECTIVE TAPE ON LIFEJACKETS. LEGACY COMPONENT DESC: Retroreflective Material
Condition: Unknown
Due 24 October 2003
Resolved 27 October 2003
Construction/Loadline
Issued 14 September 2000 Resolved
REPLACE FASTENERS ON REACH ROD FOR FOREPEAK BILGE PIPING VALVE.
Condition: Unknown
Due 14 October 2000
Resolved 18 September 2000
Accommodation/Occupational Safety
Issued 14 September 2000 Resolved
Renew flame screen on sanitation tank goose neck.
Condition: Unknown
Due 14 September 2000
Resolved 14 September 2000
Fire Fighting
Issued 14 September 2000 Resolved
Stop leak in pump priming supply water line.
Condition: Unknown
Due 14 September 2000
Resolved 14 September 2000
Electrical
Issued 14 September 2000 Resolved
INSTALL PULLEY COVER ON PORT GENERATOR ADJACENT TO LAUNDRY MACHINE.
Condition: Unknown
Due 14 October 2000
Resolved 18 September 2000
Navigation
Issued 14 September 2000 Resolved
Renew wasted steering arm gusset on starboard side.
Condition: Unknown
Due 14 September 2000
Resolved 14 September 2000
Construction/Loadline
Issued 14 September 2000 Resolved
Install bilge alarms in crew quarters/galley compartment. Through hull fittings in shower and galley sink require bilge alarm in this compartment.
Condition: Unknown
Due 14 September 2000
Resolved 14 September 2000
Engineering
Issued 14 September 2000 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 14 October 2000
Resolved 18 September 2000
Engineering
Issued 14 September 2000 Resolved
REPLACE BALL IN GOOSENECK NECK CLOSURE.
Condition: Unknown
Due 14 October 2000
Resolved 18 September 2000
Fire Fighting
Issued 14 September 2000 Resolved
PROVIDE PERMANENT MOUNTING BRACKET FOR ENGINE ROOM PORTABLE FIRE EXTINGUISHER LOCATED AT STARBOARD AFT HATCHWAY.
Condition: Unknown
Due 14 October 2000
Resolved 18 September 2000
Construction/Loadline
Issued 29 July 1999 Resolved
INSTALL ADEQUATE BILGE ALARMS, 46 CFR 182.530
Condition: Unknown
Due 29 July 1999
Resolved 29 July 1999
Lifesaving
Issued 29 January 1999 Resolved
PROVE VSL IS ARRANGED, MANUEVERABLE AND EQUIPPED TO RESCUE A HELPLESS PERSON FROM THE WATER IAW 46 CFR 180.210.
Condition: Unknown
Due 29 January 1999
Resolved 29 January 1999
Engineering
Issued 5 August 1994 Resolved
REPAIR PIN HOLE LEAK IN OUTBOARD PORT MAIN ENGINE EXHAUST AND RELAGG EXHAUST BEFORE EXHAUST COOLING WATER INLET.
Condition: Unknown
Due 5 August 1994
Resolved 5 August 1994
Engineering
Issued 5 August 1994 Resolved
GAS FREE AND REPAIR PIN HOLE IN STBD FUEL OIL TANK LOCATED IN VESTIBULE AREA LEADING TO ENGINEROOM.
Condition: Unknown
Due 5 August 1994
Resolved 5 August 1994
Documentation
Issued 6 August 1993 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 6 August 1993
Resolved 6 August 1993
Lifesaving
Issued 26 September 1991 Resolved
PROVIDE 406 MHz EPIRB ON BOARD VESSEL.
Condition: Unknown
Due 26 September 1991
Resolved 26 September 1991
Construction/Loadline
Issued 1 November 1989 Resolved
INSTALL CAPTIVE CHAINS ON ALL MAIN DECK HATCHES.
Condition: Unknown
Due 1 November 1989
Resolved 1 November 1989
Lifesaving
Issued 1 November 1989 Resolved
RENEW SIX DAYTIME AND SIX NIGHTTIME OUTDATED EMERGENCY SIGNALS.
Condition: Unknown
Due 1 November 1989
Resolved 1 November 1989
Lifesaving
Issued 1 November 1989 Resolved
RENEW OUTDATED EPIRB BATTERY.
Condition: Unknown
Due 1 November 1989
Resolved 1 November 1989
Unknown
Issued 3 November 1988 Resolved
ARRANGE ENGINE VENTILATION TO BRING INTO COMPLIANCE WITH 46CFR182.20-45(C).
Condition: Unknown
Due 3 November 1988
Resolved 3 November 1988
Deck/Cargo
Issued 3 November 1988 Resolved
MAKE PERMANENT REPAIRS TO OIL LEAK IN BOW HYDROLIC WINCH.
Condition: Unknown
Due 3 November 1988
Resolved 3 November 1988
Lifesaving
Issued 17 December 1984 Resolved
RESTENCIL LIFE FLOATS(TOP AND BOTTOM).
Condition: Unknown
Due 17 December 1984
Resolved 17 December 1984
Navigation
Issued 17 December 1984 Resolved
OBTAIN COPIES OF LIGHT LIST, TIDE TABLE, CURRENT TABLE, COAST PILOT AND NOTICE TO MARINERS. ALL OF THE ABOVE TO BE COMPLETED TO THE SATISFACTION OF THE COGNIZANT OCMI AND BY 17JAN85.
Condition: Unknown
Due 17 December 1984
Resolved 17 December 1984
Electrical
Issued 17 December 1984 Resolved
REPLACE INDICATOR LIGHTS ON SWITCHBOARD.
Condition: Unknown
Due 17 December 1984
Resolved 17 December 1984
Electrical
Issued 17 December 1984 Resolved
REPAIR OVERSPEED TRIP PORT AND STBD GENERATORS AND TEST SAME.
Condition: Unknown
Due 17 December 1984
Resolved 17 December 1984
Electrical
Issued 17 December 1984 Resolved
REPLACE POP OFF VALVE ON PORT AIR RECEIVER AND TEST SAME.
Condition: Unknown
Due 17 December 1984
Resolved 17 December 1984

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.