MAURY USCG vessel records Sign in
← All vessels

POOL RIG 55

POOL RIG 55 is a 1983 mobile offshore drilling unit. The Coast Guard has recorded 13 inspections since 1983, most recently in October 1988, along with 86 deficiencies.

Records from 1983 to 1988. Most recent: inspection, 20 October 1988.

Built
1983
Last inspected
20 October 1988
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

228666
Flag
UNITED STATES
—
Maury page id
psix-228666

Inspections, by type

…with no type recorded6
Years with a record 5 calendar years (1983–1988)
The 13 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 38 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it2245 - Regulatory (Subpart C or D), Net Ton
2245 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 13

20 October 1988 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1199498
9 April 1987 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1334329
8 April 1987 Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1021146
2 April 1987 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1018443
1 March 1987 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1321688
26 January 1987 Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1013420
26 January 1987 Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1017767
26 January 1987 Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1315823
26 February 1986 Deficiency Check
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 986417
14 February 1986 COI Inspection · Credit Drydock
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1306897
6 March 1985 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1290461
18 January 1985 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1290458
20 December 1983 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 975519

Deficiency record · 86

Electrical
Issued 2 April 1987 Resolved
REPAIR ALL INOPERABLE GENERAL ALARM BELLS.
Condition: Unknown
Due 2 April 1987
Resolved 2 April 1987
Deck/Cargo
Issued 26 January 1987 Resolved
PROVIDEW REFUELING HOSES WITH DEAD MAN TYPE NOZZELS FOR PORT AND STBD CRANES.
Condition: Unknown
Due 26 January 1987
Resolved 26 January 1987
Deck/Cargo
Issued 26 January 1987 Resolved
RENEW HYDRAVLIC HOSES (4) FROM DIRECTIONAL CONTROL BLOCK TO WHICH MOTORS, STBD CRANE.
Condition: Unknown
Due 26 January 1987
Resolved 26 January 1987
Electrical
Issued 26 January 1987 Resolved
REINSTALL FIXED CO2 SYSTEM IN EMERGENCY GENERATOR SPACE.
Condition: Unknown
Due 26 January 1987
Resolved 26 January 1987
Electrical
Issued 26 January 1987 Resolved
SHOW PROPER OPERATION OF OVERSPEED SHUT DOWNS AND REVERSE POWER RELAYS FOR NO. 1 AND NO. 2 EMDS. ALSO LOW LUDE OIL ALARM ON NO. 2 EMD.
Condition: Unknown
Due 26 January 1987
Resolved 26 January 1987
Accommodation/Occupational Safety
Issued 26 January 1987 Resolved
PROVIDE A HAND RELIEVING DEVICE ON THE RELIEF VALVE ON THE SANITARY WATER TANK LOCATED NEXT TO OMNIPURE UNIT.
Condition: Unknown
Due 26 January 1987
Resolved 26 January 1987
Accommodation/Occupational Safety
Issued 26 January 1987 Resolved
MAKE OPERABLE THE HIGH WATER ALARM ON THE MSD OMNIPURE UNIT.
Condition: Unknown
Due 26 January 1987
Resolved 26 January 1987
Deck/Cargo
Issued 26 January 1987 Resolved
RENEW ALL CRACKED OR BROKEN GLASS IN PORT AND STBD CRANES.
Condition: Unknown
Due 26 January 1987
Resolved 26 January 1987
Deck/Cargo
Issued 26 January 1987 Resolved
RPOVIDE API HAND SIGNAL CHARTS IN CONTROL CABS OF BOTH CRANES.
Condition: Unknown
Due 26 January 1987
Resolved 26 January 1987
Lifesaving
Issued 26 January 1987 Resolved
CHANGE FUEL IN BOTH LIFEBOATS.
Condition: Unknown
Due 26 January 1987
Resolved 26 January 1987
Documentation
Issued 26 January 1987 Resolved
PROVIDE ONBOARD VESSEL A COAST GUARD APPROVED CONSTRUCTION PORTFOLIO.
Condition: Unknown
Due 26 January 1987
Resolved 26 January 1987
Navigation
Issued 26 January 1987 Resolved
PAINT PORT AND STBD RUNNING LIGHT SHIELDS "FLAT BLACK".
Condition: Unknown
Due 26 January 1987
Resolved 26 January 1987
Lifesaving
Issued 26 January 1987 Resolved
CLEAN BARREL OF LINE THROWING GUN.
Condition: Unknown
Due 26 January 1987
Resolved 26 January 1987
Electrical
Issued 26 January 1987 Resolved
MAKE OPERABLE ALL EXPLOSION PROOF LIGHTS ON DRILL FLOOR.
Condition: Unknown
Due 26 January 1987
Resolved 26 January 1987
Construction/Loadline
Issued 26 January 1987 Resolved
RENEW ALL MISSING CLOSURE DOGS, LUBRICATE AND FREE UP ALL FROZEN CLOSURE DOGS, AND RENEW ALL MISSING GASKERS ON ITAKE/EXHAUST VENT COVERS THROUGH- OUT VESSEL.
Condition: Unknown
Due 26 January 1987
Resolved 26 January 1987
Lifesaving
Issued 26 January 1987 Resolved
PROVIDE THE FOLLOWING BANDAGES FOR FIRST AID KIT: THREE 4-INCH BANDAGE COMPRESSES AND EIGHT 2-INCH COMPRESSES.
Condition: Unknown
Due 26 January 1987
Resolved 26 January 1987
Documentation
Issued 26 January 1987 Resolved
MAINTAIN AN OIL RECORD BOOK IN ACCORDANCE WITH 33 CFR 151.125. (RECORD OF WASTE OIL DISPOSAL AND POLLUTION INCIDENTS)
Condition: Unknown
Due 26 January 1987
Resolved 26 January 1987
Deck/Cargo
Issued 26 January 1987 Resolved
CONDUCT AN ANNUAL HYDRO TEST OF THE FUEL OIL TRANSFER HOSE (1.5 TIMES MAX. ALLOWABLE WORKING PRESS). LOG HYDRO TEST.
Condition: Unknown
Due 26 January 1987
Resolved 26 January 1987
Electrical
Issued 26 January 1987 Resolved
MAKE OPERABLE THE LOW LUBE OIL PRESSURE ALARM ON THE EMERGENCY GENERATOR.
Condition: Unknown
Due 26 January 1987
Resolved 26 January 1987
Electrical
Issued 26 January 1987 Resolved
PROVIDE RUBBER INSULLATION MAT ON DECK, IN FRONT OF SWITCH BOARD IN EMERGENCY GENERATOR ROOM.
Condition: Unknown
Due 26 January 1987
Resolved 26 January 1987
Electrical
Issued 26 January 1987 Resolved
LABLE REMOTE FUEL OIL SHUT-OFF VALVE FOR EMERGENCY GENERATOR.
Condition: Unknown
Due 26 January 1987
Resolved 26 January 1987
Fire Fighting
Issued 26 January 1987 Resolved
REPLACE BROKEN PRESSURE GUAGE ON PORT SIDE FIRE PUMP.
Condition: Unknown
Due 26 January 1987
Resolved 26 January 1987
Electrical
Issued 26 January 1987 Resolved
REPAIR ALL INOPERABLE GENERAL ALARM BELLS.
Condition: Unknown
Due 26 January 1987
Resolved 26 January 1987
Lifesaving
Issued 14 February 1986 Resolved
OPEN LIMIT SWITCH AND CONTROLLER FOR INSPECTION, #1 & 2 LIFEBOATS.
Condition: Unknown
Due 14 February 1986
Resolved 14 February 1986
Lifesaving
Issued 14 February 1986 Resolved
CONDUCT OPERATIONAL TEST OF BOTH LIFEBOAT; OPERATE IN THE WATER, SPRAY SYSTEM.
Condition: Unknown
Due 14 February 1986
Resolved 14 February 1986
Fire Fighting
Issued 14 February 1986 Resolved
CONDUCT FIRE & BOAT DRILLS AND INSPECT GENERAL ALARMS AT EACH LOCATION.
Condition: Unknown
Due 14 February 1986
Resolved 14 February 1986
Documentation
Issued 14 February 1986 Resolved
PROVIDE ON BOARD APPROVAL LETTER FOR THE HAZARDOUS LOCATION, PLAN CCGD8 MMTLTR. DATED 26OCT84.
Condition: Unknown
Due 14 February 1986
Resolved 14 February 1986
Electrical
Issued 14 February 1986 Resolved
CHOCK BATTERIES IN PLACE INSIDE BATTERY BOXES ON THE OBSTRUCTION LIGHTS, FOG AND NAVIGATIONS LIGHTS, AND ANNUNCIATOR BOX.
Condition: Unknown
Due 14 February 1986
Resolved 14 February 1986
Electrical
Issued 14 February 1986 Resolved
TIGHTEN BATTERY TERMINAL CONNECTION TO ANNUNCIATOR BATTERIES AND LINE THE BATTERY BOX WITH LEAD OR SOME OTHER CORROSION RESISTANT MATERIAL.
Condition: Unknown
Due 14 February 1986
Resolved 14 February 1986
Electrical
Issued 14 February 1986 Resolved
REPAIR MOTOR ON DEEPWELL TO REMOVE 100% GROUND IN ELECTRICAL SYSTEM.
Condition: Unknown
Due 14 February 1986
Resolved 14 February 1986
Fire Fighting
Issued 14 February 1986 Resolved
REPLACE GENERAL ALARM CONTACT MAKER LOCATED ON STARBOARD SIDE NEAR MUD PITSWITH A CONTACT MAKER APPROVED FOR USE IN A HAZARDOUS LOCATION.
Condition: Unknown
Due 14 February 1986
Resolved 14 February 1986
Fire Fighting
Issued 14 February 1986 Resolved
PROVIDE HYDRO TEST DATE FOR THE FIXED CO2 BOTTLES & CO2 CHARGE BOTTLE FOR THE SEMI PORTABLE UNITE.
Condition: Unknown
Due 14 February 1986
Resolved 14 February 1986
Navigation
Issued 14 February 1986 Resolved
PROVIDE BATTERY FOR EPIRB.
Condition: Unknown
Due 14 February 1986
Resolved 14 February 1986
Deck/Cargo
Issued 14 February 1986 Resolved
MAKE PRELOAD TANKS 1,2,3,17,16,25,26,27 & VOIDS
Condition: Unknown
Due 14 February 1986
Resolved 14 February 1986
Lifesaving
Issued 14 February 1986 Resolved
REPLACE LIGHT STICKS FOR LIFEBOAT COMPARSER AND PROVIDE INTERIOR LIGHTS 2-3 CELLS FLASHLIGHTS POINTING TO THE OVERHEAD.
Condition: Unknown
Due 14 February 1986
Resolved 14 February 1986
Fire Fighting
Issued 14 February 1986 Resolved
PROVIDE ON CII FIRE EXTINGUISHER OUTSIDE THE EMERGENCY GENERATOR ROOM.
Condition: Unknown
Due 14 February 1986
Resolved 14 February 1986
Engineering
Issued 14 February 1986 Resolved
MAKE AIR RECEIVERS IN AIR COMPRESSOR ROOM AND ABOVE DRILL FLOOR AVAILABLE FOR INTERNAL INSPECTION OR HYDROSTATIC TEST.
Condition: Unknown
Due 14 February 1986
Resolved 14 February 1986
Deck/Cargo
Issued 14 February 1986 Resolved
TEST RELIEF VALVES TO ALL AIR RECEIVERS.
Condition: Unknown
Due 14 February 1986
Resolved 14 February 1986
Electrical
Issued 14 February 1986 Resolved
TEST THE PURGE AIR LOSS ALARM ON THE DRILLERS CONSOLE.
Condition: Unknown
Due 14 February 1986
Resolved 14 February 1986
Accommodation/Occupational Safety
Issued 14 February 1986 Resolved
INSTALL RELIEF VALVE ON HOT WATER HEATER IN LAUNDRY ROOM ON 02 LEVEL WITH RELIEF SETTING LESS THAN 100 PSIG.
Condition: Unknown
Due 14 February 1986
Resolved 14 February 1986
Electrical
Issued 14 February 1986 Resolved
LABEL EMERGENCY SHUTDOWN LOCATED AT SHALE SHAKER.
Condition: Unknown
Due 14 February 1986
Resolved 14 February 1986
Engineering
Issued 14 February 1986 Resolved
INSTALL CAPS OVER PIPING TO LUBE OIL TANK IN GENERATOR SPACE.
Condition: Unknown
Due 14 February 1986
Resolved 14 February 1986
Engineering
Issued 14 February 1986 Resolved
REMOVE PLASTIC FUEL OIL FILTER SYSTEM TO MAIN GENERATOR AND REPLACE WITH APPROVED FILTER SYSTEM.
Condition: Unknown
Due 14 February 1986
Resolved 14 February 1986
Electrical
Issued 14 February 1986 Resolved
TEST REVERSE POWER RELAYS ON BOTH MAIN GENERATORS.
Condition: Unknown
Due 14 February 1986
Resolved 14 February 1986
Electrical
Issued 14 February 1986 Resolved
TEST OVERSPEEDS OF BOTH GENERATORS PROVIDING MEANS TO MEASURE RPM'S.
Condition: Unknown
Due 14 February 1986
Resolved 14 February 1986
Engineering
Issued 14 February 1986 Resolved
INSTALL HEAT RESISTANT GLASS ON MAIN FUEL OIL TANK AND HYDRAULIC OIL TANK.
Condition: Unknown
Due 14 February 1986
Resolved 14 February 1986
Accommodation/Occupational Safety
Issued 14 February 1986 Resolved
REPAIR OR REPLACE TRANSFORMER ON OMNI-PURE SEWAGE TREATMENT SYSTEM, TO MAKESYSTEM OPERATIONAL.
Condition: Unknown
Due 14 February 1986
Resolved 14 February 1986
Electrical
Issued 14 February 1986 Resolved
REMOVE SPLICE IN ELECTRICAL CABLE NEAR SINK ABOVE MUD PITS, OR SHOW SPLICE IS APPROVED FOR HAZARDOUS LOCATIONS BY UL.
Condition: Unknown
Due 14 February 1986
Resolved 14 February 1986
Accommodation/Occupational Safety
Issued 14 February 1986 Resolved
INSTALL REST PLATES AND GUARD ON GRINDER.
Condition: Unknown
Due 14 February 1986
Resolved 14 February 1986
Accommodation/Occupational Safety
Issued 14 February 1986 Resolved
PROVIDE GUARD ON ENGINE SHAFT IN AIR COMPRESSOR ROOM.
Condition: Unknown
Due 14 February 1986
Resolved 14 February 1986
Accommodation/Occupational Safety
Issued 14 February 1986 Resolved
REMOVE OIL FROM AIR COMPRESSOR ROOM AND REMOVE OILY RAGS IN BUCKET NEAR MUDPUMPS.
Condition: Unknown
Due 14 February 1986
Resolved 14 February 1986
Lifesaving
Issued 14 February 1986 Resolved
REPAIR SPRAY SYSTEM TO PORT LIFEBOAT.
Condition: Unknown
Due 14 February 1986
Resolved 14 February 1986
Construction/Loadline
Issued 14 February 1986 Resolved
PROVIDE RUBBER GASKETING FOR ALL MAN HOLES VERSUS SILICON SEALANT AND CLEAN SURFACES TO MAKE WATERTIGHT. TO BE COMPLETED PRIOR TO NEXT RIG MOVE.
Condition: Unknown
Due 14 February 1986
Resolved 14 February 1986
Deck/Cargo
Issued 14 February 1986 Resolved
CONDUCT REQUIRED TEST TO CRANE PER 46 CFR 107.259.
Condition: Unknown
Due 14 February 1986
Resolved 14 February 1986
Documentation
Issued 14 February 1986 Resolved
PROVIDE VALID DOCUMENTATION FOR THE VESSEL 46 CFR 67 ANNUAL RENEWAL STICKER EXPIRED.
Condition: Unknown
Due 14 February 1986
Resolved 14 February 1986
Fire Fighting
Issued 14 February 1986 Resolved
PROVIDE EVIDENSE OF SERVICE FOR THE FIXED CO2 SYSTEM TRIGGER BOTTLE 46 CFR 107.235
Condition: Unknown
Due 14 February 1986
Resolved 14 February 1986
Accommodation/Occupational Safety
Issued 14 February 1986 Resolved
PROVIDE "BEWARE OF TAIL ROTOR" SIGNS AT EACH ACCESS TO THE HELICOPTER LANDING AREA 46 CFR 108.653.
Condition: Unknown
Due 14 February 1986
Resolved 14 February 1986
Electrical
Issued 14 February 1986 Resolved
PROVE SATISFACTORY OPERATOR OF THE LOW LUBE ALARM ON #1 GENERATOR.
Condition: Unknown
Due 14 February 1986
Resolved 14 February 1986
Accommodation/Occupational Safety
Issued 14 February 1986 Resolved
REMOVE OPENED PAINT, SOLVENTS, AND FLAMMABLES FROM STOREROOM ON PORT SIDE AND PLACE IN A FM OR UL APPROVED STORAGE CABINET.
Condition: Unknown
Due 14 February 1986
Resolved 14 February 1986
Deck/Cargo
Issued 14 February 1986 Resolved
INSTALL MACHINERY GUARDS OVER GEARING USED IN JACKING HOUSE.
Condition: Unknown
Due 14 February 1986
Resolved 14 February 1986
Lifesaving
Issued 14 February 1986 Resolved
CHANGE OUT FUEL OIL IN BOTH LIFEBOATS.
Condition: Unknown
Due 14 February 1986
Resolved 14 February 1986
Fire Fighting
Issued 14 February 1986 Resolved
PROVIDE ON BOARD TWO O2/LFL METERS UL OR FM APPROVED OR SUBMIT DOCUMENTATION INDICATING THE APPROVAL OF THE UNITS ON BOARD THE RIG "GASTECHTOR.
Condition: Unknown
Due 14 February 1986
Resolved 14 February 1986
Electrical
Issued 14 February 1986 Resolved
TEST EMERGENCY GENERATOR FOR AUTOMATIC TRANSFER, LOW LUBE OIL PRESSURE, ANDHIGH WATER TEMPERATURE ALARMS.
Condition: Unknown
Due 14 February 1986
Resolved 14 February 1986
Documentation
Issued 14 February 1986 Resolved
PROVIDE AN OIL RECORD BOOK, STANDARD DISCHARGE CONNECTION, AND OIL TRANSFERPROCEDURES 33 CFR 155.720
Condition: Unknown
Due 14 February 1986
Resolved 14 February 1986
Deck/Cargo
Issued 14 February 1986 Resolved
PROVIDE MARKINGS ON FUEL OIL TRANSFER HOSE (33 CFR 155.800) AND PERFORM TEST ON HOSES REQUIRED.
Condition: Unknown
Due 14 February 1986
Resolved 14 February 1986
Documentation
Issued 14 February 1986 Resolved
PROVIDE PLACARD AS REQUIRED 33 CFR 155.430
Condition: Unknown
Due 14 February 1986
Resolved 14 February 1986
Engineering
Issued 14 February 1986 Resolved
TEST EMERGENCY SHUTOFF TO AIR OPERATED FUEL OIL TRANSFER PUMP.
Condition: Unknown
Due 14 February 1986
Resolved 14 February 1986
Documentation
Issued 14 February 1986 Resolved
PROVIDE SUBMIT FOR APPROVAL A HAZARDOUS LOCATION PLAN.
Condition: Unknown
Due 14 February 1986
Resolved 14 February 1986
Engineering
Issued 14 February 1986 Resolved
INSTALL CORROSION RESISTANT SCREENING MATERIAL OVER LUBE OIL TANK VENT.
Condition: Unknown
Due 14 February 1986
Resolved 14 February 1986
Deck/Cargo
Issued 14 February 1986 Resolved
REMOVE STEEL WEDGES AND OTHER MATERIAL FROM FUEL OIL CONTAINMENT LOCATED ONDECK.
Condition: Unknown
Due 14 February 1986
Resolved 14 February 1986
Lifesaving
Issued 14 February 1986 Resolved
PROVIDE THE REQUIRED NUMBER OF CARTRIDGES FOR THE SHOULDER GUM LINE-THROWING APPLIANCE 46 CFR 108.517/46 CFR 160.031-4
Condition: Unknown
Due 14 February 1986
Resolved 14 February 1986
Lifesaving
Issued 14 February 1986 Resolved
PROVIDE ON BOARD 12 HAND HELD, ROCKET-PROPELLED, PARACHUTE RED-FLARE, DISTRESS SIGNALS 46 CFR 108.521, 46 CFR 160.36.
Condition: Unknown
Due 14 February 1986
Resolved 14 February 1986
Lifesaving
Issued 14 February 1986 Resolved
PROVIDE THE FOLLOWING EQUIPMENT FOR THE FIRST AID KIT; 24 TRIANGULAR BANDAGES AND SPLINTS 46 CFR 108.707.
Condition: Unknown
Due 14 February 1986
Resolved 14 February 1986
Accommodation/Occupational Safety
Issued 14 February 1986 Resolved
REMOVE BED SPRINGS FROM HOSPITAL SPACE AND SECURE OXYGEN BREATHING.
Condition: Unknown
Due 14 February 1986
Resolved 14 February 1986
Fire Fighting
Issued 14 February 1986 Resolved
PROVIDE RELIEF VALVES FOR BOTH FIRE PUMPS PER 46 CFR 108.417.
Condition: Unknown
Due 14 February 1986
Resolved 14 February 1986
Electrical
Issued 14 February 1986 Resolved
CLEAN CONTACTS FOR PORT LIFEBOAT WINCH MOTOR CONTROLLER 46 CFR 111.95
Condition: Unknown
Due 14 February 1986
Resolved 14 February 1986
Fire Fighting
Issued 14 February 1986 Resolved
REPLACE TWO FIRE HOSES, NOT CORRECT THREADS & DETERIOATED 46 CFR 108.425.
Condition: Unknown
Due 14 February 1986
Resolved 14 February 1986
Fire Fighting
Issued 14 February 1986 Resolved
PROVIDE FLASHLIGHTS FOR FIREMAN'S OUTFITS 46 CFR 108.497 AND MARK EACH LOCKER FOR THE FIREMAN'S OUTFITS 46 CFR 108.635.
Condition: Unknown
Due 14 February 1986
Resolved 14 February 1986
Fire Fighting
Issued 14 February 1986 Resolved
PROVIDE SPANNER WRENCHES FOR FIRE STA IN MUD PIT ROOM AND FIRE STA #5 46 CFR 108.423.
Condition: Unknown
Due 14 February 1986
Resolved 14 February 1986
Fire Fighting
Issued 14 February 1986 Resolved
REFIL AIR BOTTLE FOR THE SCBA LOCATED AT LIFEBOAT STA #2. 46 CFR 108.497
Condition: Unknown
Due 14 February 1986
Resolved 14 February 1986
Fire Fighting
Issued 14 February 1986 Resolved
LABEL FIRE STA IN MUD PIT ROOM 46 CFR 108.633
Condition: Unknown
Due 14 February 1986
Resolved 14 February 1986
Lifesaving
Issued 14 February 1986 Resolved
PROVIDE LIFEBOAT WINCH DRUMS WITH THE CAPABILITY TO HAVE THE CAPASITY HELD BY SINGLE WAPE, NO DOUBLE SPOOLING.
Condition: Unknown
Due 14 February 1986
Resolved 14 February 1986
Lifesaving
Issued 14 February 1986 Resolved
REPAIR/REPLACE BROKEN LIFE RING BRACKETS STBD BOW, PORT STERN 46 CFR 108.515
Condition: Unknown
Due 14 February 1986
Resolved 14 February 1986
Deck/Cargo
Issued 14 February 1986 Resolved
PROVIDE PLUG FOR FUEL OIL CONTAINMENT BOX 33 CFR 155.
Condition: Unknown
Due 14 February 1986
Resolved 14 February 1986
Lifesaving
Issued 14 February 1986 Resolved
WEIGHT TEST BOTH LIFEBOAT.
Condition: Unknown
Due 14 February 1986
Resolved 14 February 1986
Construction/Loadline
Issued 14 February 1986 Resolved
CONDUCT UNDERWATER SURVEY OF THE AREA BELOW THE MAT AT THE NEXT RIG MOVE.
Condition: Unknown
Due 14 February 1986
Resolved 14 February 1986

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.