MAURY USCG vessel records Sign in
← All vessels

SAFARI ENDEAVOUR

SAFARI ENDEAVOUR is a 1983 passenger vessel (inspected). The Coast Guard has recorded 136 inspections since 1984, most recently in April 2026, along with 189 deficiencies, 1 operational control and 13 casualty investigations between 2003 and 2022.

Records from 1984 to 2026. Most recent: inspection, 15 April 2026.

Built
1983
Last inspected
15 April 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8963698 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WDG2742
228668
Flag
UNITED STATES
338423000
Maury page id
psix-228668

Inspections, by type

…with no type recorded36
Years with a record 40 calendar years (1984–2026)
The 136 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)183.3 ft × 37.0 ft × 11.5 ft
Registered tonnagegross 99 / net 67
ITC dimensions (L × B × D)183.3 ft × 37.0 ft × 11.5 ft
ITC tonnagegross 1,425 / net 511
BuilderJEFFBOAT INC · JEFFERSONVILLE, IN, UNITED STATES · built 1983
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portJUNEAU, AK
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 4 February 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it511 - Convention (Subpart B), Net Ton
67 - Regulatory (Subpart C or D), Net Ton
1425 - Convention (Subpart B), Gross Ton
99 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDG2742MMSI 338423000 · active · compulsorily equipped · granted 24 February 2022, expires 18 February 2032
WDD4996MMSI 367152220 · expired · voluntarily equipped · granted 22 November 2006, cancelled 28 January 2017
WCW8883MMSI 366934000 · expired · voluntarily equipped · granted 26 September 1996, cancelled 2 December 2006
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 136

15 April 2026 Deficiency Check · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8313400
22 January 2026 Vessel Attendance · Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8296444
27 August 2025 Deficiency Check · Damage Survey
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 8220053
18 June 2025 Deficiency Check · Damage Survey
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 8163427
15 April 2025 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 8111805
8 July 2024 Deficiency Check · Damage Survey · Administrative Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7953543
1 May 2024 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7876448
20 February 2024 Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7867932
19 May 2023 Damage Survey · Deficiency Check · In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 7693280
24 March 2023 Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7656572
7 October 2022 In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7573562
18 September 2022 Deficiency Check · Damage Survey
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7562439
25 July 2022 Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 7522627
25 April 2022 COI Inspection · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7437686
18 March 2022 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7414327
9 February 2022 Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7393654
13 August 2020 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7084642
3 April 2020 COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6939615
17 October 2019 Administrative Inspection · Internal Structural Exam · Drydock Exam · Hull Examination · Examination of Repairs
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6831388
10 September 2019 In-Service Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6808356
30 April 2019 Administrative Inspection · MARPOL Annex VI Survey · MARPOL Annex I Examination · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6670283
15 October 2018 Administrative Inspection · Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6558874
19 August 2018 Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 6564691
2 May 2018 COI Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6403043
14 September 2017 Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6284327
25 April 2017 COI Inspection · MTSA Verification · MTSA/ISPS Verification · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6127650
7 October 2016 Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6017121
1 September 2016 Examination of Repairs · Damage Survey
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 5989789
22 May 2016 In-Service Inspection · Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 5885782
27 April 2016 COI Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5862007
5 October 2015 Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5738031
19 March 2014 Internal Structural Exam · COI Inspection · Deficiency Check · Examination of Repairs · Hull Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4818188
25 June 2012 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4356466
18 July 2011 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4095266
1 December 2010 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3902268
22 April 2009 MTSA/ISPS Verification · COI Inspection · Administrative Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3457758
5 March 2009 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3428140
17 November 2008 Internal Structural Exam · Underwater Inspection in lieu of Drydock
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3366273
3 August 2008 ISM Oversight
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 3288939
10 July 2008 Administrative Inspection
Administrative · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 3263934
15 April 2008 COI Inspection · MTSA Verification
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3179272
21 February 2008 Internal Structural Exam · Hull Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3153468
19 June 2007 Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 2968096
11 September 2006 Damage Survey · Examination of Repairs
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 2775732
10 September 2006 Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 2778365
6 July 2006 Deficiency Check
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 2703687
22 June 2006 Examination of Repairs
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 2688496
21 June 2006 Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 2687069
28 May 2006 Type not recorded
No type recorded · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 2673222
28 May 2006 Examination of Repairs
Physical examination · Marine Safety Detachment Sitka · USCG Arctic District (CGD-A) · Activity 2673244
25 May 2006 Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 2678651
15 April 2006 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2641479
20 January 2006 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2572273
9 November 2005 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2532000
1 November 2005 Hull Examination · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2526504
3 August 2005 Administrative Inspection
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2450063
8 June 2005 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 2392018
11 May 2005 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 2375009
12 April 2005 Internal Structural Exam · Hull Examination · COI Inspection · MTSA/ISPS Verification
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2342737
25 October 2004 Examination of Repairs
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2227769
22 October 2004 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2231079
20 September 2004 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 2200350
13 September 2004 Type not recorded
No type recorded · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 2195125
3 August 2004 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 2154954
29 July 2004 Type not recorded
No type recorded · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 2190567
24 June 2004 MTSA/ISPS Verification
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 2095400
28 May 2004 Security Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 2087704
26 May 2004 Security Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 2081136
12 May 2004 Security Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 2074262
26 April 2004 COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2052960
5 April 2004 Underwater Inspection in lieu of Drydock
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2047423
1 April 2004 Administrative Inspection
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2035383
25 March 2004 Administrative Inspection
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2031748
30 December 2003 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1971370
13 December 2003 Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1964528
26 November 2003 Hull Examination · Internal Structural Exam · COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1955169
26 June 2003 Deficiency Check · Damage Survey
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1827893
24 June 2003 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1827880
4 April 2003 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1768261
27 November 2002 COI Inspection · Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1695347
17 October 2002 Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1691687
5 August 2002 Damage Survey
Physical examination · MSD SITKA · USCG Arctic District (CGD-A) · Activity 1658745
3 August 2002 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1673908
3 December 2001 Hull Examination · COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1428129
18 August 2001 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 504451
20 February 2001 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 721005
4 June 2000 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 84825
8 December 1999 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1437640
3 December 1999 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 733185
8 November 1999 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 803724
24 July 1999 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 507907
2 July 1999 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 50475
15 May 1999 Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1402872
2 May 1999 Damage Survey
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1384117
25 November 1998 Hull Examination · COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 805925
29 September 1998 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 802019
24 September 1998 Damage Survey
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1466563
20 September 1998 Examination of Repairs
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 798911
29 June 1998 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 793105
13 April 1998 Hull Examination · Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1392866
27 January 1998 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 788758
11 December 1997 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1116972
10 November 1997 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1119905
29 October 1997 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 780296
16 October 1997 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1368449
26 September 1997 Damage Survey
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1118244
25 September 1997 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 27072
25 September 1997 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 212156
25 September 1997 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 216234
14 April 1997 Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1094008
14 March 1997 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1383457
6 February 1997 COI Inspection · Inclining Experiment
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1419686
6 August 1996 Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1359247
28 March 1996 Administrative
Administrative · Marine Safety Center (MSC) · Activity 1077685
21 December 1995 Administrative
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1182578
15 September 1995 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 874695
7 September 1995 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1190514
18 July 1995 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 879231
12 July 1995 Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 884385
25 April 1995 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1171482
19 December 1994 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 842847
7 December 1994 Hull Examination · COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 831679
10 January 1994 Hull Examination · COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 850352
15 August 1993 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 172801
30 June 1993 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 359274
7 April 1993 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1144475
8 December 1992 Hull Examination · COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 962827
4 November 1991 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 947192
23 February 1989 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1197421
23 February 1989 Administrative
Administrative · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1200891
21 February 1989 COI Inspection · Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1040277
13 December 1988 COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1213687
11 December 1987 COI Inspection · Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1001955
13 December 1986 Hull Examination · COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1024780
10 December 1985 COI Inspection · Credit Drydock
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1299911
10 December 1984 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 977923

Deficiency record · 189

07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 15 April 2026 Resolved
The general construction of the vessel shall be such as to minimize fire hazards insofar as reasonable and practicable. 1) The door leading from the galley to the engine room was unable to fully close and maintain the fire boundary. 2) Port side galley door doesn't latch properly when fire doors are activated.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 April 2026
Resolution: O/o provided video of both fire doors functioning as they should. Videos uploaded to Deficiencies-->Documents
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 15 April 2026 Resolved
All electrical installations shall be to the satisfaction of the OCMI. 1) Laundry room washer receptacle has ground pin broken off in one side of the outlet and extension cord with multiple plugs being utilized presenting an electrical hazard. 2) Junction box over the #1 SSDG is not mounted and just hanging. 3) Portable sump pump is being utilized as permanent installation using extension cord for galley ice maker drain. 4) Wires and connectors for equipment that was removed from the utility room on the 400 deck need to be secured.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 April 2026
Resolved 20 April 2026
Resolution: O/o provided objective evidence that the above deficiencies have been corrected. See deficiencies--Documents.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 April 2026 Resolved
Valves for removing water or impurities from fuel in water traps or strainers shall be provided with caps or plugs to prevent fuel leakage. Main and generator fuel filters are missing plugs for drain valves.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 April 2026
Resolved 23 April 2026
Resolution: O/o provided objective evidence of the fuel filters with the plugs installed. See Def---Docs tab.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 15 April 2026 Resolved
Each vessel must meet the applicable requirements in Subchapter S of this chapter...Penetrations and openings in watertight bulkhead penetrations must have means to make them watertight. Multiple cable penetrations at WTD #2 is loose and not watertight. Cable penetrations at WTD #1 are loose and not watertight.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 April 2026
Resolved 20 April 2026
Resolution: O/o Provided videos displaying each of the cable penetrations are properly sealed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 April 2026 Resolved
A fire control plan must show the location of fire protection/emergency equipment. The fire control plan does not show the interconnected smoke detector system installed by A Gow on 23APR2024.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 May 2026
Resolved 23 April 2026
Resolution: Received and verified amended fire and safety plan. Amended by a P.E. uploaded to vessel documents tab.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 27 August 2025 Resolved
A vessel of more than 19.8 meters (65 feet) in length carrying more than 600 passengers or with overnight accommodations for more than 49 passengers must have:(a) Two generator sets;(b) An electrical power system that complies with the requirements of §§ 111.10-4, 111.10-5, and 111.10-9, in subchapter J of this chapter;(c) A final emergency power source, as defined by § 112.01-20 in subchapter J of this chapter, with sufficient capacity to power the loads listed in § 112.15-5 in subchapter J of this chapter for three hours; and(d) The final emergency power source located outside the machinery space. The vessel's starboard side generator shutdown while underway with 74 passengers on board. The vessel's emergency generator came on within 15 seconds and the port generator was brought on line with in a couple of minutes.46 CFR 120.312 (a)(b)(c)(d)
Action required: 10 - Deficiency Rectified
Resolved 27 August 2025
Resolution: Rectified
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 15 April 2025 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel giving consideration to protection against fire. Fire Door on 2nd Deck leading to passageway for passenger accommodation did not latch. Inner spring found to be defective.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 April 2025
Resolved 15 April 2025
Resolution: Damaged spring replaced. MI reviewed video or latching door
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 15 April 2025 Resolved
…the public address system must be […] audible during normal operating conditions throughout the accommodation spaces. Passenger cabins have the ability to mute the public address system when switched to Channel 1.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 May 2025
Resolved 15 April 2026
Resolution: Verified passenger cabins are unable to mute the public address system during the annual inspection.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 15 April 2025 Resolved
Each vessel must have adequate emergency lighting fitted along the line of escape… Various instances of emergency lighting throughout vessel, as designated on Fire Control Plan, not illuminated.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 May 2025
Resolved 15 April 2025
Resolution: O/o replaced worn lights and retested emergency lighting.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 15 April 2025 Resolved
or each watertight door which is in a required subdivision bulkhead, an indicator light must be installed in the pilothouse […]. The indicator must show whether the door is open or closed. Mechanism for activation switch on 02 watertight doors found to be bent and unable to accurately indicate status of door. Due by next DDX.
Action required: 705 - Other - as specified
Due 15 April 2026
Resolved 15 April 2026
Resolution: Verified the watertight door indicators accurately indicate the status of wt door during the annual inspection.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 15 April 2025 Resolved
[…] marine inspector shall require that all observed unsafe practices and hazardous situations be corrected. Dead end wires in E/R and steering compartment.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 April 2025
Resolved 17 April 2025
Resolution: MI reviewed photo evidence of reapired dead end wires
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 1 May 2024 Resolved
Electrical equipment on a vessel must be installed and maintained to: Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock; Live deadend wires located above both main engines and generators in the engine room. 46CFR120.200
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 June 2024
Resolved 2 May 2024
Resolution: Dead end wire removed from above engines.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 18 September 2022 Resolved
A vessel of more than 19.8 meters (65 feet) in length carrying more than 600 passengers or with overnight accommodations for more than 49 passengers must have: (a) Two generator sets; (b) An electrical power system that complies with the requirements of §§111.10-4, 111.10-5, and 111.10-9, in subchapter J of this chapter; (c) A final emergency power source, as defined by §112.01-20 in subchapter J of this chapter, with sufficient capacity to power the loads listed in §112.15-5 in subchapter J of this chapter for three hours; and (d) The final emergency power source located outside the machinery space… Vessels port ship service diesel generator (SSDG) is out of commission. Repairs to be made to the satisfaction of the attending CG Marine Inspector. 46 CFR 120.312
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 24 September 2022
Resolved 24 September 2022
Resolution: Port generator oil cooler was replaced, ops check good.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 26 April 2022 Resolved
Floor framing in crew berthing #8 found corroded. Repair framing between operational season of 2022 and 2023. 46 CFR 115.610
Action required: 705 - Other - as specified
Resolved 21 April 2023
Resolution: Floor framing in crew berthing 8 was cropped and renewed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 25 April 2022 Resolved
Each major generator and motor shall be fitted with name plate. Marine inspector noted that No. 2 generator did not have a data plate attached. -46 CFR 183.10-5a ; 50C
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 June 2022
Resolved 3 May 2023
Resolution: The port and starboard motors have data plates as well as the drive engines.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 25 April 2022 Resolved
Prove proper operation of fixed sprinkling system. Vessel completed extensive repairs of sprinkler system and system was not ready for inspection during USCG attendance. -46 CFR 181.05-5 ; 50C
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 June 2022
Resolved 15 May 2023
Resolution: The system was brought up to pressure, dumped the valve on the zone and all alarms on the panel were tested. The alarm that is tied into the integrated smoke/fire detection system was tested as well.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 April 2022 Resolved
Flow meter is currently an indication of pump running but not flow or pressure. Vessel intends to install alarms associated with current flow meter -46CFR182.20-10 ; 705C-Prior to carrying passengers in 2023
Action required: 705 - Other - as specified
Resolved 21 April 2023
Resolution: Flow meter installed and alarm connected for all wet exhaust systems
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 30 April 2019 Resolved
(Cleared) 46 CFR 122.524(a) – Conduct a fire and man overboard drill in the presence of an attending CG Marine Inspector. The vessel did not provide adequate crew during the COI inspection. (Combined 2 similar CG-835 items).
Action required: 17 - Rectify deficiencies prior to departure
Due 30 April 2019
Resolved 3 May 2019
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 30 April 2019 Resolved
33 CFR 151.25(h) – Provide a corrective action plan and implement the same to ensure the Oil Record Book is being properly maintained to include Master’s signature, relevant entries with corresponding receipts and documents. (Combined 3 similar CG-835 items).
Action required: 702 - Prior to embarking on international voyage
Due 30 April 2019
Resolved 3 May 2019
01 - Certificates & Documentation › 013 - Documents › Cargo information
Issued 30 April 2019 Resolved
MARPOL VI/18.3 - Provide bunker delivery notes that provide all details required by MARPOL Annex VI.
Action required: 702 - Prior to embarking on international voyage
Due 30 April 2019
Resolved 3 May 2019
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 30 April 2019 Resolved
Provide a standard discharge connection.
Action required: 702 - Prior to embarking on international voyage
Due 30 April 2019
Resolved 30 July 2019
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 30 April 2019 Resolved
Repair the deteriorated gasket on the FSD between the accommodation space and operating station.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 May 2019
Resolved 30 July 2019
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 30 April 2019 Resolved
46 CFR 120.432(a) - Provide adequate e-lighting serving below deck spaced to the assembly station.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2019
Resolved 3 May 2019
01 - Certificates & Documentation › 013 - Documents › Cargo information
Issued 30 April 2019 Resolved
Provide reception facility receipt for the off load of sludge and oily water.
Action required: 702 - Prior to embarking on international voyage
Due 30 April 2019
Resolved 3 May 2019
01 - Certificates & Documentation › 013 - Documents › SAR co-operation plan for pass. ships on fixed trade
Issued 30 April 2019 Resolved
SOLAS (2014) V/7.3 - Provide a SAR Cooperation Plan.
Action required: 702 - Prior to embarking on international voyage
Due 30 April 2019
Resolved 26 November 2019
Resolution: SAR Co-op plan approval letter rcvd and entered into MISLE
11 - Life Saving Appliances › N/A - No Subsystem › Thermal Protective Aids
Issued 30 April 2019 Resolved
SOLAS (2014) III/22.4.1 – Provide a thermal protective aid for each person on board (9 more).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2019
Resolved 30 July 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 April 2019 Resolved
46 CFR 115.840 – Make repair to the leaking cooling water pipes for both MDE exhausts and starboard shaft seal.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2019
Resolved 3 May 2019
04 - Emergency Systems › N/A - No Subsystem › Means of communication between safety centre and other control stations
Issued 30 April 2019 Resolved
46 CFR 121.602(b) – Repair the inoperative annunciator on the sound power phone between the steering compartment and the pilothouse.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2019
Resolved 3 May 2019
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 30 April 2019 Resolved
46 CFR 115.830(a) – Remove the combustible material stowed under the dry exhaust on the port and starboard side.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2019
Resolved 3 May 2019
Electrical › Electrical Distribution System (service) › Wiring
Issued 25 April 2017 Resolved
Air conditioning unit in bow thruster/laundry room was wired with a 'permanent' extension cord. Remove and rearrange wiring to be in accordance with 46 CFR 120.340(r).
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 25 May 2017
Resolved 25 April 2017
Resolution: Extension cord removed from service. Air conditioner plugged directly into ship's outlet.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 25 April 2017 Resolved
Electrical outlet box was missing front cover, presenting shock hazard. Renew outlet cover in accordance with 46 CFR 120.200(b).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 May 2017
Resolved 25 April 2017
Resolution: New cover was affixed to electrical outlet.
Electrical › Lighting (service) › Lighting Fixture
Issued 25 April 2017 Resolved
Light fixture in A/C flat was loose and not properly mounted/secured. Mount in a fixed position in accordance with 46 CFR 120.410(c)(2).
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 9 May 2017
Resolved 25 April 2017
Resolution: Lighting fixture was properly re-mounted to ceiling framing.
Stability › Unintentional Flooding › General
Issued 25 April 2017 Resolved
Laundry room/bow thruster room bilge had nearly two feet of water in the bilge. Bilges must be clean and dry for inspection in accordance with 46 CFR 115.802(a)(1).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 April 2017
Resolved 25 April 2017
Resolution: Vessel configured bilge system and pumped water overboard to allow for inspection.
Communications › Radio Communications › EPIRB
Issued 25 April 2017 Resolved
Service or Replace EPIRB. Update any contact information as necessary in NOAA Registration.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 May 2017
Resolution: EPIRB renewed and registered.
Electrical › Electrical Distribution System (service) › Wiring
Issued 25 April 2017 Resolved
Many small electrical lines had improper terminations, including some on main propulsion engines. Terminate ends in an approved manner or remove to provide safe environment, per 46 CFR 120.200(c).
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 25 May 2017
Resolved 1 May 2017
Resolution: New wiring harnesses installed and junction boxes fitted.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 25 April 2017 Resolved
Phone in lower passageway had un-mounted junction box with exposed wires. The box should be properly mounted in a way as to not present a shock/fire hazard, in accordance with 46 CFR 120.200(b).
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 25 May 2017
Resolved 1 May 2017
Resolution: Junction box renewed.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 25 April 2017 Resolved
Engine room had excessive oil and fuel in the bilge as a result of ongoing engine maintenance. Bilges to be pumped at conclusion of engine work. 46 CFR 115.802(a)(1).
Condition: Invalid
Action required: 705 - Other - as specified
Due 9 May 2017
Resolved 1 May 2017
Resolution: Bilges pumped and cleaned.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 25 April 2017 Resolved
Oily water separator was undergoing maintenance and not available for inspection. Complete work and make available for USCG inspection prior to sailing international. 46 CFR 115.804.
Condition: Invalid
Action required: 705 - Other - as specified
Due 9 May 2017
Resolved 1 May 2017
Resolution: OWS work completed and tested sat.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 25 April 2017 Resolved
Starboard exhaust system found leaking corrosive fluid through gaskets near side-shell. Deck plate corroded & needs renewal. Make fittings leak-tight and arrest corrosion. 46 CFR 119.430(b).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 9 May 2017
Resolved 1 May 2017
Resolution: New gaskets installed and fittings tightened, sat.
Navigation › Piloting/Steering › Maneuverability Rating
Issued 25 April 2017 Resolved
Several parts of the navigation suite were tagged out for maintenance. Complete work and make ready for inspection per 46 CFR 115.804(b).
Condition: Invalid
Action required: 705 - Other - as specified
Due 2 May 2017
Resolved 1 May 2017
Resolution: Navigation suite op-tested sat during sea trials.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 25 April 2017 Resolved
Fire Control Plan D, copy onboard vessel, did not have a USCG approval letter onboard. Plans must be approved by OCMI or MSC. Provide approval to OCMI's satisfaction, per 46 CFR 116.202.
Condition: Invalid
Action required: 705 - Other - as specified
Due 9 June 2017
Resolved 1 May 2017
Resolution: Fire control plan matches current vessel configuration.
Engineering › Diesel Engine (propulsion-direct drive) › Emergency shutdown
Issued 25 April 2017 Resolved
Main diesel engines were not available for safe testing, due to other work taking place in engine room at the time. Make available for USCG inspection prior to carrying passengers. 46 CFR 115.804(a).
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 May 2017
Resolution: Generator and propulsion system op-tested sat during sea trials.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 25 April 2017 Resolved
Smoke detector batteries were expired and units were not working. Renew batteries.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 2 May 2017
Resolved 28 July 2017
Resolution: Batteries replaced and units op-tested sat.
Engineering › Fuel Oil Service System › Valve
Issued 25 April 2017 Resolved
Engine room remote fuel shut-offs could not properly actuate. Overhaul remote connection so valve can actuate.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 April 2017
Resolution: Valves overhauled and greased. Op-tested to actuate with ease.
Engineering › Diesel Engine (auxiliary) › Emergency shutdown
Issued 25 April 2017 Resolved
Generator was undergoing maintenance and was not available for inspection. Make generator ready for op-testing and inspection prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 April 2017
Resolution: Generator was re-assembled after regular maintenance was complete and op-tested sat.
Operations/Management › Drills/Instruction › Not Conducted
Issued 25 April 2017 Resolved
Vessel not ready to get underway to perform drills. Vessel must get underway and perform required drills (Fire, MOB, Abandon Ship, Security).
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 April 2017
Resolution: Vessel got underway, performed drills satisfactory.
Lifesaving › Inflatable Buoyant Apparatus › Servicing
Issued 25 April 2017 Resolved
IBA’s were being serviced at time of inspection. Make IBA’s ready for inspection prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 April 2017
Resolution: IBA’s were made available for inspection. All sat.
Construction/Loadline › Penetrations › Pipe Flange
Issued 25 April 2017 Resolved
Bow thruster tunnel has wasted plate and holes beyond acceptable levels. Crop and renew plate to original scantlings, renew unit, or propose new design at next drydock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 October 2017
Resolved 8 November 2017
Resolution: Bow thruster tunnel completely replaced, see activity 6284327.
Fire Fighting › Fire Hoses › Condition
Issued 22 May 2016 Resolved
Replace all yellow fire hoses that are not commericially lined and do not meet UL 19.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 5 June 2016
Resolved 25 May 2016
Resolution: hoses replaced.
Engineering › Bilge Water Management System › Not Operational
Issued 27 April 2016 Resolved
Bilge high level alarm inop in lazerette. 46 CFR 119.530
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 May 2016
Resolution: Attended vessel and witnessed satisfactory operation of bilge high level alarm in lazarette.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 5 October 2015 Resolved
Submit repair proposal to be conducted at next dry dock (or the next haul out) for fr 43 (MSD flat) and fr 33-43 near gray water tank. 46 CFR 115.700(b)
Action required: 705 - Other - as specified
Due 30 April 2016
Resolved 5 November 2015
Resolution: Repair Proposal is sufficient & submitted.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 28 April 2014 Resolved
Make all fire doors meet structural fire protection requirements IAW 46 CFR 116.435(c)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 May 2014
Resolved 18 May 2014
Resolution: Received email with pictures of gasket material installed on all fire doors.
Engineering › Fuel Oil Service System › Piping
Issued 28 April 2014 Resolved
Provide tape or means to prevent spray on fittings of high pressure fuel lines IAW SOLAS 74 Ed. Ch II-2, Reg 4.2.2.5.3
Condition: Invalid
Action required: 705 - Other - as specified
Due 14 May 2014
Resolved 11 May 2014
Resolution: Received email with pictures of the the engine and generator high pressure fuel fittings properly taped.
Operations/Management › Pollution › Control of Discharge of Oil
Issued 28 April 2014 Resolved
Properly mark and secure the fueling station on fantail IAW 33 CFR 104.280.
Condition: Invalid
Action required: 705 - Other - as specified
Due 14 May 2014
Resolved 30 April 2014
Resolution: Received email with pictures of the fuel containment bin properly marked and secured.
Communications › Alarms/Indicators › Autopilot Alarm
Issued 28 April 2014 Resolved
Install approved bridge navigational watch alarm system IAW SOLAS 74 Ed. Ch. V, Reg 19.2.2.3.
Condition: Invalid
Action required: 705 - Other - as specified
Due 14 May 2014
Resolved 11 May 2014
Resolution: Received email and report from Harris Electric, Inc attesting to the satisfactory installed of the approved Bridge Navigational Watch Alarm System.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 28 April 2014 Resolved
Provide directory and labeling of all panelboards and breakers IAW 46 CFR 120.220 (d).
Condition: Invalid
Action required: 705 - Other - as specified
Due 14 May 2014
Resolved 15 May 2014
Resolution: Received email with pictures of all electrical panels appropriately labeled. Email originally sent on 05/13/2014 but had to be resent due to formatting issues.
Operations/Management › Vessel Safety Management › External Certification/Verification/Control
Issued 1 December 2010 Resolved
Complete credit hull examination prior to operation/carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 April 2011
Resolved 10 October 2011
Engineering › Sea-water System (primary cooling) › Piping
Issued 20 April 2009 Resolved
Repair leak on raw water supply piping in engineroom.
Action required: 705 - Other - as specified
Resolved 25 April 2009
Resolution: New piping installed. Tested sat.
Engineering › Fuel Oil Service System › Flange
Issued 20 April 2009 Resolved
Repair f/o leak in piping fwd stbd engineroom.
Action required: 705 - Other - as specified
Resolved 25 April 2009
Resolution: Tightened connection. Tested sat.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 20 April 2009 Resolved
Install blank or spare breaker in engineroom breaker panel.
Action required: 705 - Other - as specified
Resolved 25 April 2009
Resolution: Blank installed in panel.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 20 April 2009 Resolved
Prove proper operation of OWS.
Action required: 705 - Other - as specified
Resolved 25 April 2009
Resolution: Installed components for repair that was not complete at time of initial inspection. Tested sat.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 20 April 2009 Resolved
Install fire stop in wireway above 100 deck fire screen doors.
Action required: 705 - Other - as specified
Resolved 25 April 2009
Resolution: Installed fire stop in wireway.
Lifesaving › Inflatable Liferafts › Carriage Requirement
Issued 20 April 2009 Resolved
Install liferafts not onboard at time of initial inspection.
Action required: 705 - Other - as specified
Resolved 25 April 2009
Resolution: Installed liferafts.
Fire Fighting › Automatic Sprinkler System › Testing Switches (Alarm/Sprinklers)
Issued 20 April 2009 Resolved
Prove operation of alarm when isolation valves 2 & 5 are closed.
Action required: 705 - Other - as specified
Resolved 25 April 2009
Resolution: Proved proper operation.
Communications › Alarms/Indicators › Sprinkler Alarm System
Issued 20 April 2009 Resolved
Prove proper operation of sprinkler audible alarm on bridge.
Action required: 705 - Other - as specified
Resolved 25 April 2009
Resolution: Proved proper operation of alarm.
Communications › Alarms/Indicators › Sprinkler Alarm System
Issued 20 April 2009 Resolved
Prove proper operation of zone indication at panel on bridge.
Action required: 705 - Other - as specified
Resolved 25 April 2009
Resolution: Proved proper operation.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 20 April 2009 Resolved
Repair throw on fwd dining room fire screen door to allow proper latching upon closing.
Action required: 705 - Other - as specified
Resolved 25 April 2009
Resolution: Adjusted to allow proper operation.
Fire Fighting › Automatic Sprinkler System › Piping
Issued 20 April 2009 Resolved
Repair leak on sprinkler pump discharge flange.
Action required: 705 - Other - as specified
Resolved 25 April 2009
Resolution: Renewed gaskets. Tested sat.
Engineering › Fuel Oil Service System › Valve
Issued 20 April 2009 Resolved
Label f/o shut off valves and provide wrench of proper construction to provide necessary leverage to operate valves.
Action required: 705 - Other - as specified
Resolved 25 April 2009
Resolution: Labeled and provided modified wrench.
Communications › Alarms/Indicators › General Alarm
Issued 20 April 2009 Resolved
Prove proper operation of port fwd general alarm on 300 deck.
Action required: 705 - Other - as specified
Resolved 25 April 2009
Resolution: Proved proper operation.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 20 April 2009 Resolved
Install new A class door between bridge and electronic equip storage space due to present door being compromised with unauthorized vents. Interim measure of installation of insulation inside door with stainless steel covers on both sides of door accepted as temporary measure while new door is on order.
Action required: 705 - Other - as specified
Due 1 December 2009
Resolved 25 November 2009
Resolution: New A class door installed between the bridge and electronic equip storage space.
Fire Fighting › Fixed Halon Fire Extinguishing System › Piping
Issued 20 April 2009 Resolved
Prove properation of shut down of port SSDG upon activation of halon system.
Action required: 705 - Other - as specified
Resolved 25 April 2009
Resolution: Proved proper shut down of engine.
Engineering › Freshwater System (jacketwater cooling) › Sensor
Issued 20 April 2009 Resolved
Prove proper operation of high temp alarm on stbd MDE.
Action required: 705 - Other - as specified
Resolved 25 April 2009
Resolution: Proved proper operation.
Operations/Management › Passenger Operations › Safety Orientation
Issued 20 April 2009 Resolved
Provide safety placard for room 311. Existing placard has been water damaged. To be installed upon receipt of special order.
Action required: 705 - Other - as specified
Due 1 August 2009
Resolved 25 November 2009
Resolution: Safety placard provided for room 311.
Construction/Loadline › Hull › Hull Plating
Issued 17 November 2008 Resolved
Crop-out and renew plating under bilge suction basket and bulkhead at frame 56, engineroom stores, mid ships, approx. 1.5' X 1' and port side shell at frames 72-73 at bilge knuckle approx. 8' X 10".
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 November 2009
Resolved 25 November 2009
Resolution: Cropped out and repaired to original.
Construction/Loadline › Hull › Transverse Frame
Issued 17 November 2008 Resolved
Reweld cracked weld in framing insert aft side at frame 36 port, approx. 1.5' and forward side approx. 2'. Crop-out and renew bottom 10" of frame 37, 15' inboard from side shell, approx 8'. Crop-out and renew bottom 10" of frame 39 in way of the gray water tank, approx 3'. Crop-out and renew frame 60, squash bulkhead from side shell inboard, approx. 8' X 12".
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 November 2009
Resolved 25 November 2009
Resolution: Cropped out and renewed to original.
Electrical › Electric Generation Source (emergency) › Metallic Enclosure/Frame
Issued 17 November 2008 Resolved
Renew emergency generator enclosure due to wastage and weather tight integrity.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 November 2009
Resolved 25 November 2009
Resolution: Enclosure to emergency generator was repaired and is now weather tight.
Communications › Audible Communications › Bell
Issued 15 April 2008 Resolved
Prove proper operation of 3 inoperable general alarm bells.
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 April 2008
Resolved 24 April 2008
Construction/Loadline › Markings › Load Line Mark
Issued 15 April 2008 Resolved
Provide loadlines markings in contrasting color on port and starboard sideshell.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 April 2008
Resolved 25 April 2008
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 15 April 2008 Resolved
Prove proper operation including remote closure capability of port side 200 deck fire door and port side main deck aft crew fire door.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 April 2008
Resolved 25 April 2008
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 15 April 2008 Resolved
Ensure lifejacket storage areas in passenger cabins are marked with appropriate SOLAS labels.
Due 30 April 2008
Resolved 25 April 2008
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 15 April 2008 Resolved
Replace missing FSD closure indicator on promenade deck.
Due 30 April 2008
Resolved 25 April 2008
Engineering › Pressure Vessel › Relief Valve
Issued 15 April 2008 Resolved
Replace faulty relief valve on air receiver.
Due 15 May 2008
Resolved 24 April 2008
Construction/Loadline › Structures › Door
Issued 15 April 2008 Resolved
Repair seal on forward watertight door #49
Due 15 May 2008
Resolved 24 April 2008
Construction/Loadline › Structures › Door
Issued 15 April 2008 Resolved
Repair lower hinge on watertight door # 56.
Due 15 May 2008
Resolved 24 April 2008
Electrical › Electrical Distribution System (service) › Cable
Issued 15 April 2008 Resolved
Secure electrical wiring in engine room.
Due 15 May 2008
Resolved 24 April 2008
Stability › Watertight Integrity › General
Issued 15 April 2008 Resolved
Adjust port rudder packing to prevent leakage.
Due 15 May 2008
Resolved 24 April 2008
Construction/Loadline › Hull › Transverse Frame
Issued 21 February 2008 Resolved
Repair transverse frames 35 and 37 where compromised at the turn of the bilge where they met the sideshell on the port side.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 February 2008
Resolved 12 March 2008
Construction/Loadline › Hull › Stiffener
Issued 21 February 2008 Resolved
Replace multiple verticle stiffeners found wasted between frames 33 and 40 on the port and starboard side.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 February 2008
Resolved 12 March 2008
Construction/Loadline › Hull › Stringer
Issued 21 February 2008 Resolved
Replace angle bar under the deck plate that was found corroded and in need of replacement in the crew/AC flat and in the Laundry/Bow thruster room.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 February 2008
Resolved 12 March 2008
Construction/Loadline › Penetrations › Valve Flange
Issued 21 February 2008 Resolved
Replace worn valve housing for gate valve #48 and 8 other valves called out by company.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 February 2008
Resolved 12 March 2008
Electrical › Electrical Distribution System (service) › Junction Box
Issued 21 February 2008 Resolved
Provide junction box for cables joined with wire nuts in forepeak.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 February 2008
Resolved 12 March 2008
Engineering › Diesel Engine (propulsion-reduction gear) › Cylinder
Issued 19 June 2007 Resolved
Restore engine to operational condition (#4 cylinder leaking coolant due to worn o-ring & cylinder liner).
Condition: Unknown
Action required: 705 - Other - as specified
Due 19 June 2007
Resolved 19 June 2007
Resolution: Tech rep and port engineer attended vessel, corrected problem. CG witnessed operational test of engine, sat.
Engineering › Diesel Engine (propulsion-direct drive) › Cylinder Head
Issued 11 September 2006 Resolved
Vessel is restricted on the SEADROME DOCK until repairs to the STBD Main Engine CAT 3512 are completed to the satisfaction of an attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 25 September 2006
Resolved 11 September 2006
Resolution: Repairs completed & tested engine sat. Cause of pitting on the liner unknown at this time. Possible water treatment need to be adjusted.
Engineering › Diesel Engine (propulsion-direct drive) › Cylinder Liner
Issued 11 September 2006 Resolved
Vsl's P/S Mn Engines operation restricted to the manufacturer's minimum recommendation on the pyrometer temp readings (975 degrees F) to minimized pitting & fractures to cylinder liners & until all cylinder liners inspected by CAT authorized rep [name withheld] maintenance procedures on lube oil sampling tests & water coolant treatment program.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 December 2006
Resolved 13 November 2006
Resolution: O/O provided inspection report for P/S Mn Engines. Report in documents has "MDE Inspection Results.
Engineering › Diesel Engine (propulsion-direct drive) › Cylinder Liner
Issued 11 September 2006 Resolved
Send a report of the cylinder liner inspections for the Port & STBD Main Engines to the nearest OCMI upon completion. Report must be verified either by CATERPILLAR manufacturer representative or authorized dealer.
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 December 2006
Resolved 13 November 2006
Resolution: Report sent to Sector Seattle. See documents "MDE Inspection rpt".
Electrical › Electric Supply System (service) › Battery Charger
Issued 22 June 2006 Resolved
Repair the electrical connection to the battery charger of the Port AUX GEN wire set to the 12 volt forward battery bank. Two wires found charred & insulation wire exposed. This may have cause the spark leading to the battery exploding. Big safety electrical problem. Check vent cap (clear) to battery cover for proper venting.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 July 2006
Resolved 6 July 2006
Resolution: Completed by engineer, sat.
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 22 June 2006 Resolved
Remove excessive oil in the engineroom bilges particularly under STBD Reduction gear and OWS foundation platform area.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 July 2006
Resolved 6 July 2006
Resolution: Done, sat.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 22 June 2006 Resolved
Vessel shall conform to rail courses intervals (4") as per D17 (moc) Insp Note 01-02 in the 200 deck & 300 deck area.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 22 July 2006
Resolved 27 June 2006
Resolution: Does not apply to K-boats, requirement cleared.
Construction/Loadline › Penetrations › Pipe Flange
Issued 22 November 2005 Resolved
Renew starboard overboard pipe penetration for sewege overboard located A/C space.
Action required: 705 - Other - as specified
Due 5 December 2005
Resolved 5 December 2005
Electrical › Electric Supply System (service) › Cable
Issued 1 November 2005 Resolved
Properly connect welder power supply conductors. (Remove twist on connecters and use proper crimp connectors)
Action required: 705 - Other - as specified
Due 9 December 2005
Resolved 5 December 2005
Electrical › Electrical Distribution System (service) › Conductor
Issued 1 November 2005 Resolved
Remove power strip from behind grinder located in A/C flat.
Action required: 705 - Other - as specified
Due 9 December 2005
Resolved 5 December 2005
Fire Fighting › Automatic Sprinkler System › Sprinklers
Issued 1 November 2005 Resolved
Remove interferences to sprinkler head located in aux space above sewege treatment plant.
Action required: 705 - Other - as specified
Due 9 December 2005
Resolved 5 December 2005
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 1 November 2005 Resolved
Renew hydrostatic release for the forward starboard liferaft.
Action required: 705 - Other - as specified
Due 9 December 2005
Resolved 5 December 2005
Construction/Loadline › Hull › Hull Plating
Issued 1 November 2005 Resolved
Renew area of hull plating as identified by hull gaging. Areas located port and starboard side of keel between frames 65 and 67 and outboard approx 4 feet in way of shaft packing area for port and starboard shafts.
Action required: 705 - Other - as specified
Due 5 December 2005
Resolved 5 December 2005
Construction/Loadline › Penetrations › Pipe Flange
Issued 1 November 2005 Resolved
Renew auxiliary sea chest vent line.
Action required: 705 - Other - as specified
Due 5 December 2005
Resolved 5 December 2005
Construction/Loadline › Penetrations › Pipe Flange
Issued 1 November 2005 Resolved
Remove PVC piping from cargo door overboard drain line in way of A/C space.
Action required: 705 - Other - as specified
Due 5 December 2005
Resolved 5 December 2005
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 25 October 2004 Resolved
Vessel shall not operate with passengers on board until liquid oily/fuel residue is removed from engine room bilges.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 October 2004
Construction/Loadline › Penetrations
Issued 5 April 2004 Resolved
Renew/replace fire pump seachest suction valve due to normal deterioration condition. LEGACY COMPONENT DESC: Valve Flange
Action required: 705 - Other - as specified
Resolved 7 April 2004
Resolution: Renwed/replaced with new valve.
Documentation › Certificates/Documents
Issued 25 March 2004 Resolved
VESSEL MUST PROVIDE PROOF OF CURRENT CERTIFICATE OF DOCUMENTATION BY 26APR04. VESSEL IS ALLOWED TO TRANSIT FROM LA/LB TO SEATTLE, WA WITHOUT A CURRENT CERTIFICATE OF DOCUMENTATION AS LONG AS NO PASSENGERS ARE CARRIED. LEGACY COMPONENT DESC: Certificate of Documentation (CG-1270)
Due 28 April 2004
Resolved 28 April 2004
Resolution: Sighted certificate of Documention.
Engineering › Diesel Engine (auxiliary)
Issued 10 December 2003 Resolved
In accordance with SOLAS 74 amendment accepted on 1 July 1998, Chapter II-2, Reg (15), provide and install protected fuel oil line on high pressure fuel piping on both ships service generators. LEGACY COMPONENT DESC: Fuel oil lines
Action required: 705 - Other - as specified
Due 10 January 2004
Resolved 28 January 2004
Resolution: Received field service report and photographs detailing installation of shieled fuel lines.
Communications › Alarms/Indicators
Issued 26 November 2003 Resolved
REPAIR 3 INOPERATIVE GE ALARM BELLS AND 11 UNSATISFACTORY GE ALARM BELLS LEGACY COMPONENT DESC: General Alarm
Action required: 705 - Other - as specified
Due 15 December 2003
Resolved 5 December 2003
Fire Fighting › Fire Hoses
Issued 26 November 2003 Resolved
HYDROTEST ALL FIRE HOSES AND STENCIL DATE OF TEST ON EACH HOSE LEGACY COMPONENT DESC: Condition
Condition: Improper/Lack of Maintenance
Due 15 December 2003
Resolved 9 December 2003
Lifesaving › Lifebuoys
Issued 26 November 2003 Resolved
INSTALL NEW BATTERIES IN 9 RING BOUY LIGHTS LEGACY COMPONENT DESC: Self-igniting Lights
Condition: Improper/Lack of Maintenance
Due 15 December 2003
Resolved 5 December 2003
Resolution: NEW BATTERIES INSTALLED
Accommodation/Occupational Safety › Occupational Safety
Issued 26 November 2003 Resolved
REPAIR AS ORIGINAL FIRE STATION #11 PLEXIGLASS WINDOW
Due 15 December 2003
Resolved 5 December 2003
Lifesaving › Thermal Protective Aids
Issued 26 November 2003 Resolved
RENEW OR REPAIR AS ORIGINAL 31 THERMAL PROTECTIVE AIDS
Condition: Improper/Lack of Maintenance
Due 15 December 2003
Resolved 11 December 2003
Resolution: Renewed.
Accommodation/Occupational Safety › Ventilation
Issued 26 November 2003 Resolved
CLEAN VENTS IN CERT ACCOM STORES
Due 15 December 2003
Resolved 5 December 2003
Electrical › Lighting (service)
Issued 26 November 2003 Resolved
INSTALL MISSING LIGHT FIXTURE COVER PORT SIDE IN ACCOM CERT STORES LEGACY COMPONENT DESC: Lighting Fixture
Due 15 December 2003
Resolved 5 December 2003
Electrical › Electrical Distribution System (service)
Issued 26 November 2003 Resolved
INSTALL MISSING COVERS ON 2 JUNCTION BOXES IN PORT SIDE CERT ACCOM STORES LEGACY COMPONENT DESC: Junction Box
Due 15 December 2003
Resolved 5 December 2003
Construction/Loadline › Structures
Issued 26 November 2003 Resolved
REPAIR AS ORIGINAL DECK PLATE SUPPORT FRAME IN WAY OF FRAME 20 LEGACY COMPONENT DESC: Deck Plating
Due 15 December 2003
Resolved 5 December 2003
Electrical › Lighting (service)
Issued 26 November 2003 Resolved
INSTALL MISSING LIGHT FIXTURE COVER STBD SIDE ENGINEERING STORES LEGACY COMPONENT DESC: Lighting Fixture
Due 15 December 2003
Resolved 8 December 2003
Electrical › Electrical Distribution System (service)
Issued 26 November 2003 Resolved
INSTALL MISSING BLANKS ON 2 CONTROLLER BOXES IN LAZARETTE LEGACY COMPONENT DESC: Switch
Due 15 December 2003
Resolved 10 December 2003
Accommodation/Occupational Safety › Refrigeration (stores)
Issued 26 November 2003 Resolved
REMOVE UN-USED WIRING FROM FORMER REFRIGERATION UNIT IN LAZARETTE AND PROPERLY CAP SALT WATER COOLING LINE THAT IS NO LONGER IN SERVICE.
Due 15 December 2003
Resolved 17 December 2003
Electrical › Electrical Distribution System (service)
Issued 26 November 2003 Resolved
INSTALL PACKING IN WATERTIGHT BLKHD STUFFING TUBES FOR NEW WIRE RUNS LOCATED FORWARD CREW BERTHING PASSAGE AS INDICATED BY ATTENDING MARINE INSPECTOR. LEGACY COMPONENT DESC: Cable
Due 15 December 2003
Resolved 5 December 2003
Construction/Loadline › Penetrations
Issued 26 November 2003 Resolved
Repair to new condition drain line above sewage treatment plant as indicated by attending marine inspector. LEGACY COMPONENT DESC: Drain pipe
Action required: 705 - Other - as specified
Due 15 December 2003
Resolved 5 December 2003
Accommodation/Occupational Safety › Refrigeration (air conditioning)
Issued 26 November 2003 Resolved
Install proper hose and double clamp hose ends in way of flexible joint for sea water cooling line for HVAC system. LEGACY COMPONENT DESC: Salt water cooling
Action required: 705 - Other - as specified
Due 11 December 2003
Resolved 10 December 2003
Fire Fighting › Structural - Horizontal Zones
Issued 26 November 2003 Resolved
Repair door latches and prove proper operation of both galley fire screen doors. LEGACY COMPONENT DESC: Fire door
Action required: 705 - Other - as specified
Due 11 December 2003
Resolved 10 December 2003
Fire Fighting › Structural - Horizontal Zones
Issued 26 November 2003 Resolved
Prove proper operation of port side main deck cargo loading fire screen door. LEGACY COMPONENT DESC: Fire screen door
Action required: 705 - Other - as specified
Due 11 December 2003
Resolved 10 December 2003
Fire Fighting › Structural - Horizontal Zones
Issued 26 November 2003 Resolved
Adjust fire screen door #8 located main deck port at top of stir tower to machinery space to operate properly. LEGACY COMPONENT DESC: Fire door
Action required: 705 - Other - as specified
Due 11 December 2003
Resolved 10 December 2003
Fire Fighting › Structural - Horizontal Zones
Issued 26 November 2003 Resolved
Repair upper hinge of left side fire screen door #7 and show proper operation. LEGACY COMPONENT DESC: Fire door
Action required: 705 - Other - as specified
Due 11 December 2003
Resolved 10 December 2003
Fire Fighting › Structural - Main Vertical Zones
Issued 26 November 2003 Resolved
Adjust door latch and prove proper operation of Fwd main deck fire screen door leading to aux machinery space. LEGACY COMPONENT DESC: Fire door
Action required: 705 - Other - as specified
Due 11 December 2003
Resolved 10 December 2003
Fire Fighting › Structural - Horizontal Zones
Issued 26 November 2003 Resolved
Adjust for proper operation 300 level fire doors. LEGACY COMPONENT DESC: Fire door
Action required: 705 - Other - as specified
Due 11 December 2003
Resolved 10 December 2003
Fire Fighting › Fire Pumps
Issued 26 November 2003 Resolved
Renew fire pump discharge elbow as indicated by attending marine inspector. LEGACY COMPONENT DESC: Piping
Action required: 705 - Other - as specified
Due 11 December 2003
Resolved 10 December 2003
Stability › Weathertight Integrity
Issued 26 November 2003 Resolved
Repair door latch and show proper operation of port side 300 level weather tight door. LEGACY COMPONENT DESC: Weather tight door
Action required: 705 - Other - as specified
Due 11 December 2003
Resolved 10 December 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 26 November 2003 Resolved
In accordance with amendment to SOLAS, Chap II-2, Reg (13) provide on board, and update vessel Fire Control plan, required number of emergency escape breathing devices (EEBD). LEGACY COMPONENT DESC: EEBD
Action required: 705 - Other - as specified
Due 10 January 2004
Resolved 28 January 2004
Resolution: Received photographs of all installed EEBD''s.
Electrical › Electric Generation Source (service)
Issued 26 November 2003 Resolved
prove proper operation of ships service diesel generator's reverse power relay's. Vessel shall not operate SSDG's in parallel operation until equipment proven satisfactory to attending marine inspector. LEGACY COMPONENT DESC: Reverse power relay
Action required: 705 - Other - as specified
Due 13 December 2003
Resolved 13 December 2003
Resolution: Reverse power relays tested satisfactorily.
Engineering › Compressed Air System (control)
Issued 26 June 2003 Resolved
Repair wasted reducer from ship's service air receivers supplying control air pressure to ships' control air system. LEGACY COMPONENT DESC: Piping
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 26 June 2003
Resolved 26 June 2003
Resolution: Suveyed sat.
Electrical › Electrical Distribution System (service)
Issued 27 November 2002 Resolved
Install proper cover to wiring junction box at wiring penetration to warmer oven located centerline of galley. LEGACY COMPONENT DESC: Metallic Enclosure/Frame
Action required: 705 - Other - as specified
Due 31 December 2002
Resolved 6 December 2002
Electrical › Electric Supply System (service)
Issued 27 November 2002 Resolved
Properly dead end loose cable (110 volt) located under starboard aft galley sink. LEGACY COMPONENT DESC: Cable
Action required: 705 - Other - as specified
Due 31 December 2002
Resolved 6 December 2002
Electrical › Electrical Distribution System (service)
Issued 27 November 2002 Resolved
Renew splash prrof cover on 110 volt outlet box #f-11 located above after galley sink. LEGACY COMPONENT DESC: Outlet Box
Action required: 705 - Other - as specified
Due 31 December 2002
Resolved 6 December 2002
Electrical › Electrical Distribution System (service)
Issued 27 November 2002 Resolved
Properly dead end un-used 440 volt feed cable located starboard galley in way of removed steam cooker. LEGACY COMPONENT DESC: Cable
Action required: 705 - Other - as specified
Due 10 December 2002
Resolved 6 December 2002
Electrical › Electrical Distribution System (service)
Issued 27 November 2002 Resolved
Properly dead end un-used 110 volt electrical cable on starboard side of galley in way of removed steam cooker. LEGACY COMPONENT DESC: Cable
Action required: 705 - Other - as specified
Due 10 December 2002
Resolved 6 December 2002
Electrical › Electrical Distribution System (service)
Issued 27 November 2002 Resolved
Install proper cover on dishwasher connection box located under counter adjacent to dishwasher located port side of galley. LEGACY COMPONENT DESC: Metallic Enclosure/Frame
Action required: 705 - Other - as specified
Due 31 December 2002
Resolved 6 December 2002
Electrical › Electrical Distribution System (service)
Issued 27 November 2002 Resolved
Install proper cover on outlet for reefer boxes located aft end of galley adjacent to engineers stateroom. LEGACY COMPONENT DESC: Outlet Box
Action required: 705 - Other - as specified
Due 31 December 2002
Resolved 6 December 2002
Fire Fighting › Fire Hydrants
Issued 27 November 2002 Resolved
Provide spanner wrench for fire station #7 located forward starboard on deck adjacent to forward lounge. LEGACY COMPONENT DESC: Condition
Action required: 705 - Other - as specified
Due 9 December 2002
Resolved 2 December 2002
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 27 November 2002 Resolved
Install retro-reflective tape to life ring mounted boat deck aft port side.
Action required: 705 - Other - as specified
Due 9 December 2002
Resolved 3 December 2002
Accommodation/Occupational Safety › Potable Water System
Issued 27 November 2002 Resolved
Remove incorrect pressure relief valves on hot water heaters and install correct rated valves, or open hot water heaters for internal inspection. LEGACY COMPONENT DESC: Hot water heaters
Action required: 705 - Other - as specified
Due 9 December 2002
Resolved 6 December 2002
Resolution: Proper relief valves (100 psi) installed on all 3 hot water heaters.
Construction/Loadline › Penetrations › Pipe Flange
Issued 27 November 2002 Resolved
Crop and renew wasted fuel tank vents located frame 53 port and starboard side.
Action required: 705 - Other - as specified
Due 9 December 2002
Resolved 3 December 2002
Construction/Loadline › Hull › Bottom Plating
Issued 27 November 2002 Resolved
Provide repair proposal for approval to repair puncture of aft swim step void. On approval of proposal crop and renew affected area.
Due 10 December 2002
Resolved 4 December 2002
Construction/Loadline › Hull › Weld
Issued 27 November 2002 Resolved
Clad weld approximately 15 linear feet of washed out weldments on underbody as indicated by attending marine inspector during hull examination.
Due 5 December 2002
Resolved 4 December 2002
Lifesaving › Immersion Suits
Issued 27 November 2002 Resolved
Lubricate all suit zippers and include maintenance into periodic maintenance schedule. LEGACY COMPONENT DESC: Maintenance
Action required: 705 - Other - as specified
Due 10 December 2002
Resolved 29 November 2002
Lifesaving › Immersion Suits
Issued 27 November 2002 Resolved
Renew 3 float lights on 3 survival suits LEGACY COMPONENT DESC: lights
Action required: 705 - Other - as specified
Due 10 December 2002
Resolved 29 November 2002
Construction/Loadline › Penetrations
Issued 27 November 2002 Resolved
Renew as original the 4 inch overboard valve for HVAC system. LEGACY COMPONENT DESC: Sea valves
Action required: 705 - Other - as specified
Due 10 December 2002
Resolved 4 December 2002
Construction/Loadline › Penetrations
Issued 27 November 2002 Resolved
Renew as original the 1 inch globe valve for starboard seachest vent. LEGACY COMPONENT DESC: Sea valves
Action required: 705 - Other - as specified
Due 10 December 2002
Resolved 4 December 2002
Communications › Alarms/Indicators › General Alarm
Issued 27 November 2002 Resolved
Repair or renew ganeral alarm bell located on fantail and demonstrate proper operation.
Action required: 705 - Other - as specified
Due 10 December 2002
Resolved 6 December 2002
Fire Fighting
Issued 8 November 1999 Resolved
DEMONSTRATE COMPLIANCE WITH REQUIREMENT 3 OF G-MSE-4 LETTER DATED NOVEMBER 3, 1998 (PLAN REVIEW REQUIREMENTS FOR SPRINKLER SYSTEM)
Condition: Unknown
Due 8 November 1999
Resolved 8 November 1999
Navigation
Issued 2 May 1999 Resolved
MAKE PERMANENT REPAIR TO PORT RUDDER ASSEMBLY/LINKAGE.
Condition: Unknown
Due 2 May 1999
Resolved 2 May 1999
Fire Fighting
Issued 25 November 1998 Resolved
REPLACE RELIEF VALVE FOR SPRINKLER SYSTEM UNFIRED PRESSURE VESSEL WITH A PROPER VALVE WITH HAND RELIEVING ABILITY.
Condition: Unknown
Due 10 December 1998
Resolved 21 December 1998
Fire Fighting
Issued 25 November 1998 Resolved
DEMONSTRATE COMPLIANCE WITH REQUIREMENTS 2,3,& 6 OF G-MSE-4 LETTER DATED NOVEMBER 3, 1998. (PLAN REVIEW REQUIREMENTS FOR SPRINKLER SYSTEM)
Condition: Unknown
Due 25 November 1998
Resolved 25 November 1998
Engineering
Issued 24 September 1998 Resolved
MAKE AVAILABLE FOR COAST GUARD INSPECTION, PORT MAIN ENGINE EXHAUST BUTTERFLY VALVE. THIS ITEM IS TO BE COMPLETED PRIOR TO CARRIAGE OF PASSENGERS, BUT IN NO CASE LATER THAN 02 OCT 98._x001C_ _x001C_
Condition: Unknown
Due 24 September 1998
Resolved 24 September 1998
Fire Fighting
Issued 13 April 1998 Resolved
DEMONSTRATE PROPER OPERATION OF GALLEY FIXED FIRE EXTINGUISHING SYSTEM PRIOR TO CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 15 April 1998
Resolved 16 April 1998
Fire Fighting
Issued 13 April 1998 Resolved
DEMONSTRATE PROPER OPERATION OF TIME DELAY FOR ENGINE ROOM FIXED HALON SYSTEM PROR TO CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 15 April 1998
Resolved 16 April 1998
Fire Fighting
Issued 6 February 1997 Resolved
Obtain Coast Guard approval of newly inbstalled fire sprinkler system. No later than 01OCT97 when new SOLAS regs required it.
Condition: Unknown
Due 6 February 1997
Resolved 6 February 1997
Fire Fighting
Issued 7 December 1994 Resolved
CORRECT FAULT INDICATION FROM FIRE DETECTION PANEL ZONE 15 (ENGINEROOM).
Condition: Unknown
Due 7 December 1994
Resolved 7 December 1994
Documentation
Issued 7 December 1994 Resolved
OBTAIN CERTIFICATE OF INSPECTION FOR STERN TENDER PRIOR TO CARRIAGE OF PASSENGERS ON TENDER VESSEL.
Condition: Unknown
Due 3 January 1995
Resolved 3 January 1995
Documentation
Issued 7 December 1994 Resolved
PROVIDE RESULTS OF STABILITY CALCULATIONS ASSOCIATED WITH MODIFICATIONS FORTENDER DAVITS SUBMITTED TO U.S. COAST GUARD G-MSC-1 TO [name withheld].
Condition: Unknown
Due 3 January 1995
Resolved 3 January 1995
Construction/Loadline
Issued 7 December 1994 Resolved
PROVIDE RESULTS OF STRUCTURAL ANALYSIS FROM U.S. COAST GUARD G-MSC-1 FOR TENDER DAVITS TO [name withheld].
Condition: Unknown
Due 8 December 1994
Resolved 8 December 1994
Construction/Loadline
Issued 7 December 1994 Resolved
PROPERLY FASTEN DECK PLATING TO DECK PLATE FRAMING THROUGHOUT SECOND DECK.
Condition: Unknown
Due 3 January 1995
Resolved 3 January 1995
Construction/Loadline
Issued 7 December 1994 Resolved
PROVIDE COUNTERWEIGHT FOR BOW THRUSTER ROOM EMERGENCY ESCAPE SCUTTLE.
Condition: Unknown
Due 3 January 1995
Resolved 3 January 1995
Electrical
Issued 7 December 1994 Resolved
RENEW DETERIORATED SUPPLY WIRING TO NAVIGATION LIGHT LOCATED ON OPEN DECK ABOVE PILOT HOUSE.
Condition: Unknown
Due 3 January 1995
Resolved 3 January 1995
Documentation
Issued 30 June 1993 Resolved
The vessel did not have a Waste Management Plan in writing and posted. The Master was under the impression that because his vessel is under 100 gross tons he was not required to post a written plan. He was made aware of the regulation and he had a plan typed and posted at that time.
Condition: Unknown
Due 30 June 1993
Resolved 7 July 1993
Accommodation/Occupational Safety
Issued 30 June 1993 Resolved
The vessel did not have a sufficient number of MARPOL V placards posted.
Condition: Unknown
Due 30 June 1993
Resolved 7 July 1993
Electrical
Issued 8 December 1992 Resolved
REMOVE HOUSEHOLD TYPE FLOURESCENT LIGHTING FIXTURES IN ENGINEROOM AND REPLACE WITH UL APPROVED MARINE TYPE FLOURSECENT FIXTURES.
Condition: Unknown
Due 8 December 1992
Resolved 8 December 1992
Lifesaving
Issued 8 December 1992 Resolved
INSTALL AND PROVE PROPER OPERATION OF GENERAL ALARM BELL ON AFT SIDE OF SUNDECK SUPERSTRUCTURE.
Condition: Unknown
Due 8 December 1992
Resolved 8 December 1992
Construction/Loadline
Issued 8 December 1992 Resolved
REPLACE MISSING DOG ON PORT SIDE PROMINADE DECK WATERTIGHT SIDE DOOR.
Condition: Unknown
Due 8 December 1992
Resolved 8 December 1992
Unknown
Issued 23 February 1989 Resolved
OBTAIN AN INSPECTION FOR CERTIFICATION PRIOR TO PLACING VSL BACK IN OPERA- TION.
Condition: Unknown
Due 23 February 1989
Resolved 23 February 1989
Electrical
Issued 11 December 1987 Resolved
INSTALL MINIMUM 1/2 INCH WIDE METAL BANDS FOR THE ELECTRICAL WIRING WHERE SECURED WITH NYLON TIE WRAPS.
Condition: Unknown
Due 11 December 1987
Resolved 11 December 1987
Documentation
Issued 11 December 1987 Resolved
SUBMIT CALCULATIONS AND/OR DATA TO AMEND THE STABILITY LETTER TO ALLOW -139- PERSONS, VICE -137-, OR DOWNGRADE THE CERTIFICATE OF INSPECTION.
Condition: Unknown
Due 11 December 1987
Resolved 11 December 1987
Electrical
Issued 11 December 1987 Resolved
INSTALL A COVER FOR THE GENERAL ALARM FUSE PANEL IN THE EMERGENCY GENERATORROOM.
Condition: Unknown
Due 11 December 1987
Resolved 11 December 1987
Fire Fighting
Issued 11 December 1987 Resolved
RENEW FIRE STATION NO. 6 HOSE VALVE.
Condition: Unknown
Due 11 December 1987
Resolved 11 December 1987
Engineering
Issued 11 December 1987 Resolved
INSTALL THE HEAT SHIELDS ON THE RACOR FUEL FILTERS OF THE #1 MDE AND #2 S/S GENERATOR PRIME MOVER.
Condition: Unknown
Due 11 December 1987
Resolved 11 December 1987
Electrical
Issued 11 December 1987 Resolved
PROVIDE AN OPERATIONAL TACHOMETER FOR THE #1 S/S GENERATOR PRIME MOVER.
Condition: Unknown
Due 11 December 1987
Resolved 11 December 1987
Deck/Cargo
Issued 13 December 1986 Resolved
SUBMIT OR PROVIDE AN APPROVED PLAN FOR THE MODIFICATION TO THE PORT AND STBBOAT CRANE, SUN DECK AFT.
Condition: Unknown
Due 13 December 1986
Resolved 13 December 1986
Deck/Cargo
Issued 13 December 1986 Resolved
PROVE THAT THE INSTALLATION OF THE HYDRAULIC PUMPS ADJACENT TO THE P &S LIFERAFT STOWAGE WILL NOT INTERFERE TO THE RELEASE OR DEPLOYMENT OF THE LIFERAFTS AND PROVIDE ADEQUATE ACCESSIBILITY TO LIFERAFTS.
Condition: Unknown
Due 13 December 1986
Resolved 13 December 1986
Construction/Loadline
Issued 13 December 1986 Resolved
PROVIDE APPROVED PLAN FOR THE RELOCATION OF ACCESS TO THE STEERING GEAR ROOM.
Condition: Unknown
Due 13 December 1986
Resolved 13 December 1986
Unknown
Issued 13 December 1986 Resolved
PROVIDE PLAN OR INTENTION OF THE VESSEL TO THE USE AND OPERATION OF TWO RUBBER BOATS STOWED AFT OF THE SUN DECK INCLUDING THE CARRIAGE OF SPARE GASOLINE IF THERE IS A NEED FOR IT.
Condition: Unknown
Due 13 December 1986
Resolved 13 December 1986
Lifesaving
Issued 13 December 1986 Resolved
RELOCATE RELEASING GEAR PINS ON PORT AND STBD. FORWARD MOST LIFERAFTS LAUNCHING GEAR, PRIOR TO SAILING.
Condition: Unknown
Due 13 December 1986
Resolved 13 December 1986
Deck/Cargo
Issued 13 December 1986 Resolved
THE NEWLY INSTALLED BOAT CRANE, PORT AND STBD., ARE NOT TO BE USED UNTIL THE INSTALLATION IS APPROVED BY THE COAST GUARD.
Condition: Unknown
Due 13 December 1986
Resolved 13 December 1986
Construction/Loadline
Issued 13 December 1986 Resolved
PROVE THE SATISFACTORY COMPLETION OF THE MODIFICATION TO THE FORWARD CABINSSUN DECK,PORT AND STARBOARD, AFT OF THE PILOTHOUSE, FR 33-38, INSTALLATION AND WORKMANSHIP IN ACCORDANCE WITH APPROVED PLAN OR DRAWING NO.86-002 AND COMMENTS LETTER BY G-MSC-1, 28NOV86.
Condition: Unknown
Due 13 December 1986
Resolved 13 December 1986

Casualty record · 13

24 June 2003Routine · role: Involved in a Marine Casualty · activity 1827880
22 October 2004Routine · role: Involved in a Marine Casualty · activity 2231079
25 May 2006Routine · role: Involved in a Marine Casualty · activity 2678651
28 May 2006Routine · role: Involved in a Marine Casualty · activity 2673222
21 June 2006Routine · role: Involved in a Marine Casualty · activity 2687069
10 September 2006Routine · role: Involved in a Marine Casualty · activity 2778365
25 August 2007Routine · role: Involved in a Marine Casualty · activity 3113898
26 May 2009Routine · role: Involved in a Marine Casualty · activity 3488738
20 August 2009Routine · role: Involved in a Marine Casualty · activity 3575846
22 August 2009Routine · role: Involved in a Marine Casualty · activity 3590168
19 May 2010Routine · role: Involved in a Marine Casualty · activity 3746672
19 August 2018Routine · role: Subject to Marine Inspection · serious marine incident, as classified · 1 injured · activity 6564691
25 July 2022Routine · role: Involved in a Marine Casualty · activity 7522627
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

SPIRIT OF ENDEAVOUR (2003–2010). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.