Records from 1985 to 1988. Most recent: inspection, 3 May 1988.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Engineering
Issued 5 September 1987
Resolved
MAKE THE WATER AND FIRESIDE ON THE AUXILIARY STEAM BOILER AVAILABLE FOR INSPECTION BY A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 31 March 1988
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 5 September 1987
Resolved
PERFORM A HYDROSTATIC TEST ON THE AUXILIARY STEAM BOILER IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 31 March 1988
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 5 September 1987
Resolved
MAKE AVAILABLE FOR INTERNAL EXAMINATION OR HYDROSTATICALLY TEST NO. 1 AND NO. 2 STARTING AIR TANKS, IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 31 March 1988
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 12 January 1987
Resolved
PROVIDE AN INTERNATIONAL SHORE CONNECTION ON BOARD THE VESSEL,
Condition: Unknown
Due 12 January 1987
Resolved 12 January 1987
Unknown
Issued 30 September 1985
Resolved
UPDATE ALL CHARTS AND PUBLICATIONS TO REFLECT THE LATEST ADMIRALTY NOTICES/NOTICE TO MARINERS.
Condition: Unknown
Due 30 September 1985
Resolved 30 September 1985
Unknown
Issued 30 September 1985
Resolved
RECHARGE OR REMOVE THE DRY CHEMICAL FIRE EXTINGUISHER LOCATED IN THE ENGINEERING WORKSHOP.
Condition: Unknown
Due 30 September 1985
Resolved 30 September 1985
Unknown
Issued 30 September 1985
Resolved
REPAIR/REPLACE THE FIRE NOZZLE AT FIRE STATION #8 (FORWARD CEMENT ROOM)
Condition: Unknown
Due 30 September 1985
Resolved 30 September 1985
Unknown
Issued 30 September 1985
Resolved
REPAIR/REPLACE THE RELIEF VALVE FOR THE #2 START AIR RECEIVER SO THAT IT IS CAPABLE OF BEING HAND RELIEVED.
Condition: Unknown
Due 30 September 1985
Resolved 30 September 1985
Unknown
Issued 30 September 1985
Resolved
PROVIDE AND MAINTAIN AN OIL RECORD BOOK.
Condition: Unknown
Due 30 September 1985
Resolved 30 September 1985
Unknown
Issued 27 March 1985
Resolved
PROVIDE 10 LIFEJACKETS ABOARD WITH APPROVED WATERLIGHS ONBOARD. VSL IS LIMITED TO A MAX OF 16 PERSONS ABORD UNTIL THIS ITEM IS COMPLETED. VSLS ROUTE IS LIMITED TO VOYAGES OF NOT MORE THAN 20 MILES OFF THE COAST OF SAMATERA AND SINGAPORE UNTIL THIS ITEM IS COMPLETED.
Condition: Unknown
Due 27 March 1985
Resolved 27 March 1985
Unknown
Issued 27 March 1985
Resolved
INSTALL A DAVIT FOR RESCUE BOAT AND WEIGHT TEST THE SAME TO 900 LBS ON IN- STALLATION. CONDUCT A BOAT DRILL OPERATING THE DAVITS AND RESCUE BOAT. THEVSL IS LIMITED TO VOYAGES OF NOT MORE THAN 20 MILES OFF THE COAST OF SAMATERA AND SINGAPORE UNTIL THIS ITEM IS COMPLETED.
Condition: Unknown
Due 27 March 1985
Resolved 27 March 1985
Unknown
Issued 27 March 1985
Resolved
PROVIDE TWO OARS WITH OAR LOCKS AND BOAT HOOK FOR RESCUE BOAT. THE VESSEL IS LIMITED TO VOYAGES OF NOT MORE THAN 20 MILES OFF THE COAST OF SAMATERA AND SINGAPORE UNTIL THIS ITEM IS COMPLETED.
Condition: Unknown
Due 27 March 1985
Resolved 27 March 1985
Unknown
Issued 27 March 1985
Resolved
PROVIDE A COAST GUARD APPROVED AUTOMATION TEST PROCEDURE.
Condition: Unknown
Due 27 March 1985
Resolved 27 March 1985
Unknown
Issued 27 March 1985
Resolved
PROVIDE APPROVED GUIDANCE FOR USE OF THE STABILITY TANKS FITTED ON THE VESSEL.
Condition: Unknown
Due 27 March 1985
Resolved 27 March 1985
Unknown
Issued 27 March 1985
Resolved
REQUEST FOR DRYDOCK EXTENSION IS DENIED. MAKE VESSEL AVAILABLE FOR DRYDOCKEXAMINATION IMMEDIATELY.
Condition: Unknown
Due 27 March 1985
Resolved 27 March 1985
Unknown
Issued 27 March 1985
Resolved
PROVIDE TWO SERVICED 20 MAN LIFE RAFTS ABOARD. VESSEL CURRENTLY HAS ONLY ONE RAFT ABOARD AND IT REQUIRES SERVICING. VSL IS LIMITED TO VOYAGES OF NOTMORE THAN TWENTY MILES OFF THE COAST OF SAMATERA AND SINGAPORE UNTIL THIS ITEM IS COMPLETED.
Condition: Unknown
Due 27 March 1985
Resolved 27 March 1985
Unknown
Issued 27 March 1985
Resolved
REPAIR AND PROVE OPERATION OF THE FOLLOWING BOW THRUSTER EQUIPMENT: (A) OVERSPEED TRIP. (B) RECONNECT LOCAL ALARM PANEL DED END WIRES AND PROVE OPERATION OF ALL ALARM INDICATIONS ON THIS PANEL AND (C) PROVER OPERATION OF HIGH JACKET WATER TEMPERATURE SHUT DOWN AND LOW LUBE OIL PRES. SHUTDOWN.
Condition: Unknown
Due 27 March 1985
Resolved 27 March 1985
Unknown
Issued 27 March 1985
Resolved
CROP AND RENEW APPROX 48"X36" SECTION OR STBD SIDE SHELL APPROX 36" ABOVE THE WATER LINE BETWEEN THE THIRD AND FOURTH FRAME OF THE TOP OF NO. 2A STBDWING TANK WHERE HOLED AND DOUBLED.
Condition: Unknown
Due 27 March 1985
Resolved 27 March 1985
Unknown
Issued 27 March 1985
Resolved
REPAIR VESSELS EMERGENCY PORTABLE LIFE RAFT RADIO.
Condition: Unknown
Due 27 March 1985
Resolved 27 March 1985
Unknown
Issued 27 March 1985
Resolved
REPAIR AFTER PORT SEARCH LIGHT.
Condition: Unknown
Due 27 March 1985
Resolved 27 March 1985
Unknown
Issued 27 March 1985
Resolved
MAKE THE FOLLOWING REPAIRS TO THE VESSELS AUTOMATION SYSTEM. (A) REPAIR FIREMAIN PRESSURE GAUGE ON THE BRIDGE, (B) REPAIR ENGINE ORDER TELEGRAPH, (C) REPAIR STBD ENGINE OIL MIST DETECTOR AND (D) REPAIR STBD ENGINE SHAFT PILLAR BEARING HIGH TEMPERATURE ALARM.
Condition: Unknown
Due 27 March 1985
Resolved 27 March 1985
Unknown
Issued 27 March 1985
Resolved
PROVIDE AND POST WHERE REQUIRED THE FOLLOWING PUBS. AND PLACARDS: (A) TWO INSTRUCTIONS FOR DONNING LIFE JACKETS, (B) TWO INST FOR LAUNCHING LIFERAFTS(C) TWO WATCH QUARTER AND STATION BILLS, (D) POST CERT OF INSP AND (E) PRO-VIDE COPIES OF THE CURRENT SUBCHAPTER I REGS AND THE COL REGS ABOARD.
Condition: Unknown
Due 27 March 1985
Resolved 27 March 1985
Unknown
Issued 27 March 1985
Resolved
INSTALL A HORN FOR THE ENGINE ROOM TELEPHONE.
Condition: Unknown
Due 27 March 1985
Resolved 27 March 1985
Unknown
Issued 27 March 1985
Resolved
REMOVE PORTABLE CORDS AND INSTALL TWO OUTLETS FOR 220 VOLTS, ONE IN THE ENGINE ROOM AND ONE NEAR THE HATCH TO THE MAIN DECK.
Condition: Unknown
Due 27 March 1985
Resolved 27 March 1985
Unknown
Issued 27 March 1985
Resolved
PROVE THE OPERATION OF THE FOLLOWING EQUIPMENT ON THE OIL FIRE 30 PSI BOILER: (A) FLAME FAILURE WITH BURNER OPERATING AND AT LIGHT OFF, (B) AUTO-MATIC CYCLING OF THE BURNER AT HIGH AND LOW TEMPERATURES, (C) HIGH TEMPE- RATURE ALARM AND SHUT DOWN (D) LOW WATER SHUT DOWN AND ALARM.
Condition: Unknown
Due 27 March 1985
Resolved 27 March 1985
Unknown
Issued 27 March 1985
Resolved
INSTALL A FIXED FIRE FIGHTING SYSTEM AND EXPLOSION PROOF LIGHT AND ELEC- TRICAL FITTINGS IN PAINT LOCKER. THIS INSTALLATION IS TO BE COAST GUARD APPROVED. THIS ITEM IS TO BE COMPLETED AT DRYDOCK BUT NOT LATER THAN COMPLIANCE DATE.
Condition: Unknown
Due 27 March 1985
Resolved 27 March 1985