← All vessels
ENHYDRA
Passenger (Inspected) · Passenger Ship class · Built 1980s · USCG Southwest District (CGD-SW) · Other hulls named ENHYDRA
ENHYDRA is a 1983 passenger vessel (inspected). The Coast Guard has recorded 98 inspections since 1985, most recently in April 2024, along with 148 deficiencies, 4 operational controls and 1 casualty investigation in 2024.
Records from 1985 to 2024. Most recent: inspection, 19 April 2024.
- Built
- 1983
- Last inspected
- 19 April 2024
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 148 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 1 investigation · 2024
Identity
654894
WDJ6539
228675
Flag
UNITED STATES
367798780
Maury page id
psix-228675
Inspections, by type
…with no type recorded13
Years with a record
37 calendar years (1985–2024)
The 98 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Tonnage as PSIX records it61 - Regulatory (Subpart C or D), Net Ton
113 - Convention (Subpart B), Net Ton
89 - Regulatory (Subpart C or D), Gross Ton
378 - Convention (Subpart B), Gross Ton
113 - Convention (Subpart B), Net Ton
89 - Regulatory (Subpart C or D), Gross Ton
378 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
WDJ6539MMSI 367798780 · active · compulsorily equipped · granted 7 July 2017, expires 7 July 2027
WDD8769MMSI 367302530 · expired · compulsorily equipped · granted 12 July 2007, cancelled 16 September 2017 · licensed under a name not among this hull’s recorded names (not shown)
WTC3217MMSI not assigned · expired · compulsorily equipped · granted 30 March 1998, cancelled 21 June 2008 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 98
19 April 2024
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7898427
29 February 2024
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7866046
4 January 2024
Damage Survey
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7845374
4 January 2024
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7953481
26 December 2023
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7842578
15 June 2023
Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7716309
23 May 2023
Deficiency Check · In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7608014
13 April 2023
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7660612
3 April 2023
Plan Review "T" Boat · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7666831
28 December 2022
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7613944
4 November 2022
Deficiency Check · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7589472
9 October 2022
In-Service Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7575496
9 October 2022
Type not recorded
No type recorded · USCGC BLACKFIN (WPB 87317) · USCG Southwest District (CGD-SW) · Activity 7592944
22 September 2022
Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7499829
2 March 2022
Deficiency Check · In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7404771
15 February 2022
Hull Examination · Examination of Repairs
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7381493
14 December 2021
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7367922
25 June 2021
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7235818
24 June 2021
COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7228477
24 April 2021
Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7182000
23 April 2021
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7189165
19 April 2021
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7178648
25 September 2020
Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7065054
24 September 2019
In-Service Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6790526
26 March 2019
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6637641
8 October 2018
Deficiency Check · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6557402
18 September 2018
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6537359
20 September 2017
Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6265889
22 August 2017
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6248429
26 June 2017
Administrative Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6260364
6 June 2017
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6160583
1 August 2016
Deficiency Check · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5959640
17 June 2016
Deficiency Check · COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5910249
17 December 2015
Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5783946
13 October 2015
Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5741565
19 May 2014
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4866534
7 June 2012
Internal Structural Exam · Deficiency Check · Administrative Inspection · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4336260
28 October 2010
DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3870025
25 February 2010
Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3690570
10 February 2010
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3678025
16 July 2009
Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3535856
4 December 2008
DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3373394
18 September 2007
Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3063044
4 August 2005
Administrative Inspection
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 2451145
23 June 2005
Deficiency Check
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 2400256
24 May 2005
MTSA Verification · Re-Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 2363545
28 September 2004
Hull Examination
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 2207209
26 May 2004
Annual Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 2078744
6 August 2003
Deficiency Check
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1869089
28 May 2003
Annual Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1820591
17 June 2002
Deficiency Check
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1631830
26 April 2002
COI Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1609793
3 May 2001
Re-Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1410544
8 June 2000
Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 212701
26 May 2000
Re-Inspection · Deficiency Check
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1460412
18 October 1999
Hull Examination
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 806728
26 July 1999
Deficiency Check
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1106636
3 May 1999
COI Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1450295
1 April 1999
Deficiency Check
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 787024
11 March 1999
Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 815049
16 September 1998
Administrative
Administrative · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 800549
22 May 1998
Re-Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1419952
2 June 1997
Deficiency Check
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 787132
6 May 1997
Re-Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1368216
3 May 1996
COI Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1392453
2 May 1995
COI Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1353735
2 November 1994
Hull Examination
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1171139
4 May 1994
COI Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1420869
3 May 1993
COI Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1414145
16 July 1992
Administrative
Administrative · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1268354
4 June 1992
Deficiency Check
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 948120
5 May 1992
COI Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1473314
3 May 1991
COI Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 928582
31 May 1990
Deficiency Check
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1230622
1 May 1990
COI Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1242865
31 October 1989
Hull Examination
Physical examination · MSO CLEVELAND · USCG Great Lakes District (CGD-GL) · Activity 1320299
12 May 1989
Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1200291
9 May 1989
COI Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1348768
9 September 1988
Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1348860
3 June 1988
Deficiency Check
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1199750
31 May 1988
Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 888783
26 May 1988
COI Inspection
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1195404
19 May 1988
Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1351189
26 April 1988
Administrative
Administrative · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1038056
19 April 1988
Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1033066
9 March 1988
Examination of Repairs
Physical examination · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1029506
25 February 1988
Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1334016
17 February 1988
Type not recorded
No type recorded · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1021825
29 January 1988
Administrative
Administrative · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1015490
27 January 1988
Plan Review "T" Boat
Administrative · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1323502
22 December 1987
Plan Review "T" Boat
Administrative · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1006484
14 December 1987
Plan Review "T" Boat
Administrative · MSO BUFFALO · USCG Great Lakes District (CGD-GL) · Activity 1006482
18 August 1987
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1031328
15 June 1987
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1008372
15 April 1987
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1309013
14 April 1986
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1000893
13 March 1986
Credit Drydock
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 998076
11 April 1985
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 980868
Deficiency record · 148
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 29 February 2024
Resolved
A vessel that is exposed to salt water more than 3 months in any 12 month period must undergo a dry dock examination and internal structural exam at least once every 2 years. Vessel failed to complete dry dock exam prior to 29FEB2024. Vessel must complete satisfactory dry dock exam prior to returning to service as an inspected small passenger vessel.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 4 January 2024
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull. Vessel lost its anchor and ran aground aground in Long Beach Harbor. Vessel required to submit repair plan to USCG Sector LALB of intended repair. Vessel restricted from carrying pax.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 26 December 2023
Resolved
Except as otherwise provided in this section, each space accessible to passengers or used by the crew on a regular basis, must have at least two means of escape, one of which must not be a watertight door. The vessel’s galley has only one means of escape, leading aft. Vessel is prohibited from carrying overnight passengers or utilizing overnight accommodations until regulations or alternative compliance is met to OCMI satisfaction.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 26 December 2023
Resolved
The two required means of escape must be widely separated and, if possible, at opposite ends or sides of the space to minimize the possibility of one incident
blocking both escapes. The vessel’s galley has only one means of escape, leading aft. Vessel is prohibited from carrying overnight passengers or utilizing overnight accommodations until regulations or alternative compliance is met to OCMI satisfaction.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 26 December 2023
Resolved
The minimum clear opening of a door or passageway used as a means of escape must not be less than 810 millimeters (32 inches) in width, however, doors or passageways used solely by crew members must have a clear opening not less than 710 millimeters (28 inches). The sum of the width of all doors and passageways used as means of escape from a space must not be less than 8.4 millimeters (0.333 inches) multiplied by the number of passengers for which the space is designed. The doorways for all passenger berthing rooms are 30 inches in width. Vessel is prohibited from carrying overnight passengers or utilizing overnight accommodations until regulations or alternative compliance is met to OCMI satisfaction.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 26 December 2023
Resolved
A means of escape which is not readily apparent to a person from both inside and outside the space must be adequately marked in accordance with § 185.606 of this
chapter. Doors and/or hatches that serve as a means of escape are not properly marked “EMERGENCY EXIT, KEEP CLEAR”. Vessel is prohibited from carrying overnight passengers or utilizing overnight accommodations until regulations or alternative compliance is met to OCMI satisfaction.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 15 June 2023
Resolved
Each life float must be fitted with a lifeline, pendants, two paddles, a painter, and a light. The lifeline must be as furnished by the manufacturer with the approved life float. Each paddle must be of at least 4 feet in length, lashed to the life float to which it belongs, and buoyant. Life floats must not be stowed in tiers more than 4 feet high. When stowed in tiers, the separate units must be kept apart by spacers. The name of a vessel must be marked or painted in clearly legible letters and numbers on each life float and each life float paddle. One paddle was missing from one of the life floats, the lifelines of numerous life floats were found to be deteriorated, many paddles were not lashed to their life float, spacers were missing from between many of the life floats, the marking of the vessel's name was found to be faded on two of the life floats, and the vessel's name was not marked on numerous life float paddles.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 June 2023
Resolved
An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard, or rail. The starboard engine belt was found to be missing its cover/guard.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 15 June 2023
Resolved
Vessels having overnight accommodations for passengers must have an interconnected fire detection system in compliance with 46 CFR 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces. The fire detector located in the galley was missing.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 15 June 2023
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, and the vessel from electrical hazards, including fire and electrical shock. MIs observed two missing bulkhead emergency lights and one that was inoperable as well as 18 open lighting receptacles in passenger accommodation areas.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 15 June 2023
Resolved
Each distribution panel must be protected from falling debris and dripping or splashing water. The engine room panel is missing its door.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 June 2023
Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets. The container for child life jackets was not labeled with the life jacket storage capacity and size.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Other (Conditions of employment)
Issued 15 June 2023
Resolved
Employers must ensure that they and their crewmembers meet the requirements of this part (46 CFR 16). While conducting a DAPI spot check, consortium enrollment confirmation, an accurate crewmember list, and most recent MIS report could not be provided. Additionally, alcohol testing equipment could not be provided.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 15 June 2023
Resolved
Except on a vessel limited to daytime operations, the magnetic compass must be illuminated. The vessel could not prove illumination of the magnetic compass.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 15 June 2023
Resolved
Portable watertight containers for distress flares and smoke signals shall be of a bright color, and containers shall be clearly marked in legible contrasting letters at least 0.5 inches high: “DISTRESS SIGNALS”.
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 15 June 2023
Resolved
When, in accordance with § 178.210 of this chapter, a vessel must be provided with a stability letter, the stability letter must be posted under glass or other suitable transparent material, such that all pages are visible, at the operating station of the vessel. Only the third/last page of the stability letter has been posted and is visible at the operating station.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 May 2023
Resolved
A vessel must be operated in accordance with applicable
laws and regulations in such a manner as to afford
adequate precaution against hazards that might endanger
the vessel and the persons to be transported.
Deficiencies 02-05 provide objective evidence that the
vessel is substandard and not proactively managing
technical and operational requirements. Vessel must
complete a satisfactory expanded annual inspection prior
to any movement.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 May 2023
Resolved
At each inspection, all observed unsafe practices, fire hazards, and other hazardous situations must be corrected. The vessel had approximately 20 gallons of flammable liquids stored throughout the vessel in unapproved storage locations. Additionally, the vessels flammable storage cabinets on the uppermost deck were no longer in a serviceable condition.
09 - Working and Living Conditions › 091 - Living Conditions › Cleanliness
Issued 23 May 2023
Resolved
A passenger accommodation space must be maintained to minimize fire and safety hazards and to preserve sanitary conditions. Passenger accommodation areas had a strong smell of sewage and were cluttered with excessive trash that obstructed the means of emergency egress.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 23 May 2023
Resolved
Rails or equivalent protection must be installed near the periphery of all decks of a vessel accessible to passengers or crew. The vessels rail courses on the uppermost passenger deck were either missing, deteriorated, or very loose.
09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 23 May 2023
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, and the vessel from electrical hazards, including fire and electrical shock. The vessel had numerous wiring issues which posed a major hazard to passengers and crew. The hazards identified include: 01 non operational emergency light, open receptacles in passenger accommodation areas, exposed wiring in the overhead of berthing areas, a deteriorated shore power cable, and an air compressor which was being powered off of a 30 foot extension cord.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 May 2023
Resolved
Each ring life buoy on a vessel must be approved in accordance with 46 CFR 160.050. Vessel's ring buoy on the starboard bridge wing is no longer in serviceable condition.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 23 May 2023
Resolved
Each life float must be fitted with a lifeline, pendants, two paddles, a painter, and a light. The vessel's life float light was not operational.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 23 May 2023
Resolved
A vessel must be provided with a satisfactory arrangement for draining any watertight compartment. Vessel had approximately 10" of standing water in the machinery space bilge.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 23 May 2023
Resolved
Fire fighting drills and training shall be logged or otherwise documented for review by the Coast guard upon request. Vessel did not have an official logbook and lacked adequate documentation of passenger manifests, drills, and monthly EPIRB testing.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 23 May 2023
Resolved
At each inspection, all observed unsafe practices, fire hazards, and other hazardous situations must be corrected. Vessel has a leaking fuel hose on the port diesel generator.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 May 2023
Resolved
Each life jacket must be marked in clearly legible block capital letters with the vessel's name. The vessel had numerous life jackets which were labeled with a different vessel's name.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 23 May 2023
Resolved
At each inspection, all observed unsafe practices, fire hazards, and other hazardous situations must be corrected. Vessels bilge discharge piping has an excessive leak.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 23 May 2023
Resolved
The float-free link required by 180.130(a)(1) must be of proper strength for the size of the life float as indicated on its identification tag. Vessel had 02 life floats which were missing their identification tag for the weak link.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 23 May 2023
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel with the terms of its COI giving consideration to the provisions for a seaworthy hull. The vessel has excessive hull deterioration on the uppermost deck and on the starboard midships embarkation door. The vessel is required to conduct hull thickness gauging and must make repairs prior to obtaining credit dry dock.
08 - Alarms › N/A - No Subsystem › General alarm
Issued 28 December 2022
Resolved
Vessels described by 46 CFR 175.110(d) must submit plans to the cognizant OCMI, in accordance with 46
CFR 176.700, for the installation and use of monitoring device to ensure the wakefulness of the
watchmen required in paragraph (a) of this section.
Vessel has not submitted plans or installed the required Watchmen system. Vessel is restricted from carrying overnight passengers until deficiency is rectified.
46CFR185.410(b)
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 28 December 2022
Resolved
An interconnected detection and alarm system must: (1) Consist of multiple-station smoke detectors listed by an NRTL, or independent laboratory accepted by the Commandant according to 46 CFR subpart 159.010, as meeting UL 217 (incorporated by reference, see 46 CFR 175.600); (2) Be installed such that the actuation of alarm in one area results in both audible and visual alarms in all areas required by 46 CFR 181.405(c) or 118.400(d) to be protected by the interconnected detection and alarm system; (3) Contain an independent power source; and (4) Alarm on low power.
Vessel has not installed an interconnected Fire detection system as required. Vessel is restricted to no more than Limited Coastwise route until deficency is rectified.
46CFR181.450
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 4 November 2022
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull, protection against fire, means of escape in case of a sudden unexpected casualty, guards and rails in hazardous places, ventilation of enclosed spaces, and necessary facilities for passengers and crew. Local lifeguard reported inspected vessel collided with another recreational boat. Vessel not to carry passengers until after Marine Inspector approval.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 9 October 2022
Resolved
The master of a vessel, except a vessel listed in § 122.502(a), shall keep a correct, written count of all passengers that embark on and disembark from the vessel. Prior to departing on a voyage, the passenger count must be communicated verbally or in writing, and available ashore at the vessel's normal berthing location or with a representative of the owner or managing operator of the vessel. The passenger count shall be available to the Coast Guard upon request. Operator could not provide a count for how many people were on board or how many people departed the vessel in the past 24 hours.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 22 September 2022
Resolved
Except on a vessel limited to daytime operations, the compass must be illuminated. Compass light could not be energized.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 September 2022
Resolved
Each portable fire extinguisher on a vessel must be of an approved type. Fire extinguishers do not mean type approval with out proper mounting. Found a fire extinguisher not mounted to a secure location.
10 - Safety of Navigation › N/A - No Subsystem › Voyage or passage plan
Issued 22 September 2022
Resolved
The master of a vessel required to prepare a crew and passenger list by paragraph (a) of this section shall see that the list is prepared prior to departing on a voyage. The list must be communicated verbally or in writing ashore at the vessel's normal berthing location or with a representative of the owner or managing operator of the vessel. The crew and passenger list shall be available to the Coast Guard upon request.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 22 September 2022
Resolved
Where the station power does not exceed 250 watts carrier power or 1500 watts peak envelope power, the radio operator must hold a marine radio operator permit or higher class license.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 22 September 2022
Resolved
A portable watertight container marked as required by § 185.614 of this chapter, carried at the operating station. Flares found in a nonwatertight container.
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage treatment plant
Issued 22 September 2022
Resolved
When operating a vessel on a body of water where the discharge of treated or untreated sewage is prohibited by the Environmental Protection Agency under 40 CFR 140.3 or 140.4, the operator must secure each Type I or Type II device in a manner which prevents discharge of treated or untreated sewage.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 December 2021
Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. Vessel exceeded two year interval. Vessel required to undergo satisfactory drydock examination prior to carrying passengers.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 19 April 2021
Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. Vessel exceeded two year interval on 01APR2021. Vessel required to undergo satisfactory drydock examination prior to departure or carrying passengers.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 25 September 2020
Resolved
Gauges to indicate lubricating oil pressure shall be provided for all propulsion engines and located so as to be in view of the operator Vessel needs to prove oil pressure gauges in pilot house are operational.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Ventilators, air pipes, casings
Issued 25 September 2020
Resolved
All enclosed spaces within the vessel shall be properly vented or ventilated. Where such opening would endanger the vessel under adverse weather conditions, means shall be provided to close them. Vessel shall fix port side goose-neck.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 25 September 2020
Resolved
Each survival craft must be secured to the vessel by a painter with a float-free link. Vessel to replace old painters with satisfactory line.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 25 September 2020
Resolved
Each door, hatch, or scuttle, used as a means of escape, must be capable of being opened by one person, from either side, in both light and dark conditions. Vessel to provide a means of opening port side crew accommodation escape hatch with handle.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 25 September 2020
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of the COI giving consideration to necessary facilities for passengers and crew. Vessel to repair starboard side emergency ladder pin angle iron.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 September 2019
Resolved
At each initial and subsequent inspection for certification, the MI shall require that all observed unsafe practices and hazardous situations be corrected. MI identified fuel leak on the Port Main Diesel Engine fuel pump. Vessel to make proper repairs.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 24 September 2019
Resolved
A hatch exposed to the weather must be watertight. All (06) flush deck hatches are inoperable & do not seal.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 24 September 2019
Resolved
At each initial & subsequent inspection for certification, the MI shall require that all observed unsafe practices & hazardous situations be corrected. All smoke detectors on vessel are outside manufactures 10 year renewal recommendations. Vessel not authorized overnight accommodations until detectors are renewed with UL217 detectors.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 24 September 2019
Resolved
Each battery used in an item of life saving equipment must be replaced during the annual inspection if the expiration date of the battery has passed. Water light batteries are expired on all water lights. Renew all batteries & conduct maintenance on battery terminals. Vessel not authorized night time operations until batteries renewal.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 September 2019
Resolved
At each initial & subsequent inspection for certification the MI shall examine & test for safe electrical condition. (02) outlets on pilothouse are loose and unserviceable. Vessel service outlets.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 September 2019
Resolved
Pressure vessels must be tested & inspected in accordance with part 61 subpart 61.10. Vessel to make pressure vessel available for inspection.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Company verification, review and evaluation
Issued 24 September 2019
Resolved
Vessel to provide a copy of their 2018 MIS report.
05 - Radio Communications › N/A - No Subsystem › Performance standards for radio equipment
Issued 24 September 2019
Resolved
Vessel to provide an updated copy of FCC safety certificate.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 September 2019
Resolved
Vessel to remove refrigerator from pilot house & (03) daisy chained surge protectors from pilot house.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 24 September 2019
Resolved
Vessel to remove accumulation of oil in engine room. Vessel had 8 five gallon pails of oil unsecured in stbd side engine room.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 24 September 2019
Resolved
Vessel to remove unauthorized propane grill and (03) associated propane tanks from vessel.
09 - Working and Living Conditions › 091 - Living Conditions › Sleeping room
Issued 24 September 2019
Resolved
All mattresses must comply with either: (1) The US Dept. of Commerce standard for mattress flammability (FF 4-72.16), 16 CFR Part 1632, subpart A & not contain polyurethane foam; or (2) IMO Res. A.688(17) (incorporated by reference, see 46 CFR 175.600). Mattresses that may contain polyurethane foam. Vessel to provide sufficient proof that all on board mattresses meet the required standards. Vessel to remove, replace/renew all mattresses from vessel if they do not meet required standard; as indicated.
09 - Working and Living Conditions › 092 - Working Conditions › Anchoring devices
Issued 8 October 2018
Resolved
A vessel must be fitted with ground tackle and mooring lines necessary for the vessel to be safely anchored or moored. Vessel does not have an anchor onboard because the line that attaches to the anchor chain frayed and parted.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 18 September 2018
Resolved
46 CFR 180.175(f)(4) Light. The light must be a floating wateright approved under approval series 161.010 or other standard specified by the Commandant.
Replace batteries in floating water lights attached to lifefloats; batteries must be of an approved make/model for the floating waterlight (Qty. 2); the installed batteries did not comply with the approved make/model as listed on the casing/body of the floating light.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 18 September 2018
Resolved
46 CFR 180.175(f)(3)(iv) Painter. Be stowed in such a way that it runs out freely when the life float or buoyant apparatus floats away from a sinking vessel.
Life Floats not stowed in a float free arrangement that would allow the free flow of the pointer lines. Reconfigure Life Floats and paineter line to ensure float free arrangements.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 18 September 2018
Resolved
46 CFR 164.46(d)((iii) Operations AIS. The accurate broadcast of a properly assigned Maritime Mobile Service Identity (MMSI) number.
AIS broadcasting incorrect vessel informatin, MMSI No. and Call Sign. Correct AIS to broadcast correct vessel information.
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 20 September 2017
Resolved
Provide covers for all open spaces on all circuit breakers.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 20 September 2017
Resolved
Provide temporary cover for all rotating machinery and open piping while repairing bow thruster machinery.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 9 June 2017
Resolved
Replace/renew STBD shaft due to current condition, as identified.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 9 June 2017
Resolved
Make port shaft available for inspection or replace due to corrosion.
Fire Fighting › Fire Main › Material
Issued 8 July 2016
Resolved
Replace 3 pipe couplings with permanent piping.
Stability › Weathertight Integrity › General
Issued 8 July 2016
Resolved
Repair forward weather tight doors.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 8 July 2016
Resolved
Provide Professional Engineer statement as to background/stucture of blackwater tank. Aft transverse bulkhead is starting to buckle at integration on blackwater tank.
Electrical › Electric Generation Source (service) › Generator
Issued 13 October 2015
Resolved
At the time of the inspection, both generators were not operating properly. Prove proper operation of both generators, prior to operating. 46 CFR 183.310
Fire Fighting › Fire Pumps › Power Source
Issued 13 October 2015
Resolved
Provide proof of proper operation of the Main Fire pump prior to carrying passengers. 46 CFR 181.300
Electrical › Electrical Distribution System (service) › Panelboard
Issued 13 October 2015
Resolved
Several distribution panels were missing the front cover. Replace covers prior to carrying passengers. 46 CFR 183.330
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 13 October 2015
Resolved
Prove operation of all Emergency Lighting on battery power prior to carrying passengers. 46 CFR 183.432 (b)
Communications › Radio Communications › EPIRB
Issued 13 October 2015
Resolved
Install EPIRB to float free prior to carrying passengers. 46 CFR 180.64
Operations/Management › Vessel Activity › Loading
Issued 13 October 2015
Resolved
Provide proof from Marine Safety Center there is no restrictions for passengers carried on the upper deck. 46 CFR 170.120
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 28 October 2010
Resolved
Provide Marine Sanitation Device Information Placard.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 28 October 2010
Resolved
Provide cover for breaker box in engine room. 46 CFR 183.05-15
Accommodation/Occupational Safety › Ventilation › General
Issued 28 October 2010
Resolved
Engine Room Ventillation Screen needs to be replaced. 46 CFR 182.20-45
Engineering › Diesel Engine (propulsion-reduction gear) › Block
Issued 25 February 2010
Resolved
Oil leak STBD MDE speed sensor.
Engineering › Diesel Engine (propulsion-reduction gear) › Cylinder Head
Issued 25 February 2010
Resolved
Repair exhaust leak Port MDE inboard exhaust.
Engineering › Diesel Engine (propulsion-reduction gear) › Cylinder Head
Issued 25 February 2010
Resolved
Replace oil saturated exhaust lagging Port MDE
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 25 February 2010
Resolved
Properly label #2 breakers above tool box in E/R
Accommodation/Occupational Safety › Occupational Safety › Spark Producing Device
Issued 25 February 2010
Resolved
Replace electrostatic matting with proper type in way of switchboard E/R
Fire Fighting › Fire Pumps › Power Source
Issued 25 February 2010
Resolved
Label fire pump start switch
Electrical › Electric Generation Source (service) › Panelboard
Issued 25 February 2010
Resolved
Repair/Replace gauges #1 Generator
Engineering › Diesel Engine (propulsion-reduction gear) › Valve
Issued 25 February 2010
Resolved
Repair Port MDE oil gauge.
Lifesaving › Lifefloat › Approval
Issued 25 February 2010
Resolved
Clarify abandon ship procedures.
Fire Fighting › Portable CO2 Fire Extinguisher › Location
Issued 25 February 2010
Resolved
Add extinguisher in storage space to master list.
Engineering › Sea-water System (primary cooling) › Piping
Issued 25 February 2010
Resolved
Properly secure R/W piping to bulkhead in Pump room.
Lifesaving › Inflatable Liferafts › Not on Board
Issued 25 February 2010
Resolved
Provide 4' paddles for all life floats.
Fire Fighting › Fixed Fire Detection System › UL 217 Approval
Issued 25 February 2010
Resolved
Provide two UL 217 detectors. for rooms 108,211
Operations/Management › Drills/Instruction › Safety Orientation
Issued 25 February 2010
Resolved
Place passenger safety orientation in writing with vessel documents.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 25 February 2010
Resolved
Replace expired medication in first aid kit.
Lifesaving › Lifefloat › Serviceable
Issued 25 February 2010
Resolved
Provide Lifefloat maint. records, mfg instructions and list of items to inspect and what to look for when conducting monthly inspections.
Operations/Management › Drills/Instruction › Abandon Ship
Issued 25 February 2010
Resolved
Crew are to conduct emergency drills witnessed by CG marine inspector prior to carrying passengers for hire.
Stability › Watertight Integrity › General
Issued 25 February 2010
Resolved
Make pump room bulkhead penetrations watertight.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 25 February 2010
Resolved
Post illuminated exit signs near exits.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 10 February 2010
Resolved
Operator is required to conduct an Annual inspection prior to 04 December 2009, per 46 CFR 176.500.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 4 December 2008
Resolved
Vessel to provide proof of being in compliance with DAPI and EAP.
Personnel › Certificates/Documents/Licenses › License, Master
Issued 4 December 2008
Resolved
Provide valid documentation for licensed Master/mate and number of deckhands when underway less than 12 hours.
Operations/Management › Drills/Instruction › Not Conducted
Issued 4 December 2008
Resolved
Full crew are to conduct all safety drills witnessed by CG marine inspector.
Fire Fighting › Fire Pumps › Pressure
Issued 4 December 2008
Resolved
Renew fire pump gauge.
Engineering › Diesel Engine (propulsion-reduction gear) › Valve
Issued 4 December 2008
Resolved
Install plugs/caps on all machinery lube oil drain lines.
Fire Fighting › Remote Fuel Shutoff › General
Issued 4 December 2008
Resolved
Repair port/starboard fuel oil emergency shut-off pulls.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 4 December 2008
Resolved
Install smoke detectors in accommodation rooms 108 & 211.
Lifesaving › Lifejacket/PFD (Type II) › Storage
Issued 4 December 2008
Resolved
Remove all six life jacket lockers from second deck.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 4 December 2008
Resolved
Remove or secure all unsecured free standing lockers throughout the vessel.
Electrical › Electrical Distribution System (service) › Shore Connection Box
Issued 4 December 2008
Resolved
Install j-box for electrical shore tie cable splice or remove from the vessel.
Engineering › Electric Propulsion System › Wiring
Issued 4 December 2008
Resolved
Install j-box or remove all open ended wires on both main engines.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 4 December 2008
Resolved
Repair insulation in engine room overhead IWO starboard generator.
Engineering › Fuel Oil Service System › Vent Pipe
Issued 4 December 2008
Resolved
Install flame screens in all fuel oil vents.
Electrical › Electrical Distribution System (service) › Cable
Issued 24 May 2005
Resolved
Install cable supports in engine room as noted by marine inspector.
Electrical › Electrical Distribution System (service) › Cable
Issued 24 May 2005
Resolved
Remove extension cords used for heater in galley. Provide appropriate cable installation.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 24 May 2005
Resolved
Inspect all life jackets and replace retro-reflective material as needed.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 24 May 2005
Resolved
Operator does not have an EAP program and does not display the required information.
Lifesaving › Buoyant Apparatus › Not on Board
Issued 26 May 2004
Resolved
remove (1) unserviceable bouyant apparatus and replace as needed. passenger capacity limited to 200 when operating more than one mile from shore
Communications › Radio Communications › EPIRB
Issued 28 May 2003
Resolved
Prove proper operation of the EPIRB test feature.
Operations/Management › Drills/Instruction
Issued 2 May 2002
Resolved
Conduct drills in presence of marine inspector.
Accommodation/Occupational Safety
Issued 26 May 2000
Resolved
REPLACE BROKEN WINDOW IN DOOR ON MAIN DECK PORT SIDE AFT
Lifesaving
Issued 26 May 2000
Resolved
INSTALL RETRO-REFLECTIVE TAPE IN FOUR PLACES ON BOTH SIDES OF ALL THREE LIFE RING BOUYS.
Lifesaving
Issued 26 May 2000
Resolved
THIS VESSEL IS LIMITED TO NOT MORE THAN ONE MILE FROM SHORE WHEN CARRYING MORE THAN 240 PERSONS.
Lifesaving
Issued 26 May 2000
Resolved
REPLACE SEVEN(7) BOUYANT APPARATUS THAT ARE CONDEMNED WITH LIFE FLOATS AS PER 46 CFR 117.200
Documentation
Issued 3 May 1999
Resolved
PROVIDE PROOF OF COMPLIANCE WITH CHEMICAL TESTING PROGRAM
Documentation
Issued 3 May 1999
Resolved
PROVIDE STATION BILL FOR VESSEL.
Construction/Loadline
Issued 11 March 1999
Resolved
VESSEL CAN NOT OPERATE WITH PASSENGERS UNTIL IT IS IN COMPLIANCE WITH THE NEW BILGE SYSTEM REQUIREMENTS.
Unknown
Issued 6 May 1997
Resolved
OPERATING CREW TO PERFORM SATISFACTORY DRILLS WHEN FULLY MANNED.
Unknown
Issued 6 May 1997
Resolved
PROVIDE PROOF OF COMPLIANCE WITH DRUG TESTING PROGRAM.
Unknown
Issued 6 May 1997
Resolved
PROVIDE CURRENT FCC GREAT LAKES RADIOTELEPHONY CERTIFICATE.
Lifesaving
Issued 3 May 1996
Resolved
Conduct in the presence of an attending USCG marine inspector satisfactory fire and man overboard drills.
Lifesaving
Issued 3 May 1996
Resolved
Place onboard additional 65 Type 1 approved PFDs to the satisfaction of theattending USCG marine inspector.
Navigation
Issued 3 May 1996
Resolved
Obtain to the satisfaction of the attending USCG marine inspector currentlycorrected light list or appropriate extract.
Lifesaving
Issued 3 May 1996
Resolved
Post to the satisfaction of the attending USCG marine inspector the Emergency Radio Placard.
Lifesaving
Issued 3 May 1996
Resolved
Post to the satisfaction of the attending USCG marine inspector revised Emergency Instructions.
Lifesaving
Issued 3 May 1996
Resolved
Post to the satisfaction of the attending USCG marine inspector PFD_x001C_ Placards.
Lifesaving
Issued 3 May 1996
Resolved
Renew to the satisfaction of the attending USCG marine inspector PFD retroreflective material on the approx. 50 PFDs where retroreflective material is unsat.
Lifesaving
Issued 3 May 1996
Resolved
Secure cooking appliances iaw 46 CFR 184.220 to the satisfaction of the attending USCG marine inspector.
Navigation
Issued 3 May 1996
Resolved
Place onboard most current Inland Rules of the Road (NAVRULES) to the satisfaction of the attending USCG marine inspector.
Construction/Loadline
Issued 2 May 1995
Resolved
Free up fresh water tank valve to the satisfaction of the attending Coast Guard marine inspector.
Engineering
Issued 2 May 1995
Resolved
Replace torn port side fuel vent flame screen to the satisfaction of the attending Coast Guard marine inspector.
Construction/Loadline
Issued 2 May 1995
Resolved
Clean to the satisfaction of the attending Coast Guard marine inspector theclogged bilge strainer in "wine cellar" compartment.
Electrical
Issued 2 May 1995
Resolved
Repair electrical light in lazerette to the satisfaction of the attending Coast Guard marine inspector.
Electrical
Issued 5 May 1992
Resolved
Provide appropriate marine electrical socket for ornamental lighting display.
Navigation
Issued 5 May 1992
Resolved
Provide current C.G. Light List.
Deck/Cargo
Issued 5 May 1992
Resolved
Provide suitable second anchor.
Lifesaving
Issued 9 May 1989
Resolved
LIFEPRESER.STORAGE AREAS WERE NOT MARKED WITH TYPE AND NUMBER CONTAINED IN AREAS
Engineering
Issued 26 May 1988
Resolved
INSTALL VALVE AND REACH ROD IN FOREPEAK ON BILGE SYSTEM SUCTION LINE.
Engineering
Issued 15 April 1987
Resolved
REPAIR OR REPLACE THE PORT MAIN ENGINE TACHOMETER IN THE PILOT HOUSE.
Casualty record · 1
4 January 2024Routine · role: Involved in a Marine Casualty · activity 7953481
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.