07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 22 May 2025
Resolved
All escape hatches and other emergency exits used as means of escape must be marked on both sides in clearly legible letters at least 2 inches high: EMERGENCY EXIT, KEEP CLEAR, Porperly label all emergency exits.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 June 2025
Resolution: Emergency exits labeled.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 May 2024
Resolved
The station bill of a vessel of more than 65 feet in length, required to have more than four crew members, must set forth the special duties and duty station of each crew member for various emergencies. The station bill on board the vessel did not include or fully address for each crew member (list is from reg site):
(1) The closing of (as applicable) hatches, airports, watertight doors, vents, scuppers, and valves for intake and discharge lines that penetrate the hull, the stopping of fans and ventilating systems, and the operating of all safety equipment;
(2) The preparing and launching of survival craft and rescue boats (This content is NOT APPLICABLE, however, recommend content include duties for recovery of a person in water);
(3) The extinguishing of fire; and
(4) The mustering of passengers including the following:
(i) Warning the passengers;
(ii) Assembling the passengers and directing them to their appointed stations; and
(iii) Keeping order in the passageways and stairways and generally controlling the movement of the passengers.
Resolve by 05 July 2024.
Action required: 705 - Other - as specified
Due 5 July 2024
Resolved 20 June 2024
Resolution: Station Bill placed in galley, and pilot house.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 22 May 2024
Resolved
IAW 46 CFR 116.115 vessel is authorized to meet regulations applicable to the vessel on March 10, 1996. On passenger decks of vessels engaged in an excursion type operation, rails shall be at least 42 inches high. The space below the rail shall be fitted with bulwarks, chain link fencing, wire mesh, or the equivalent. Space below rail was not fitted with an bulwarks, chain link fencing, wire mesh, or equivalent.
Resolve by 05 July 2024.
Action required: 705 - Other - as specified
Due 5 July 2024
Resolved 20 June 2024
Resolution: Vessel is old T-L. Requirement for hoizontol courses is 12 inches. Vessel's courses are 9 inches. Deficiency cleared.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 May 2024
Resolved
Each vessel inspected and certificated under the provisions of this Subchapter (K) must, when any passengers are aboard during the tenure of the certificate, be in full compliance with the terms of the certificate. COI requires Senior Deckhand to be designated in writing by the vessel Master. Senior deckhands listed but not specifically designated by each credentialed officer employed as the vessel's master.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 June 2024
Resolution: CSenior deckhands listed, and specifically desinated by each credentialed employed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 May 2024
Resolved
Spanner wrenches must be provided for each fire hydrant required by this regulation. A sufficient number of spanner wrenches (one per hydrant) were not provided.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 20 June 2024
Resolution: Spanner wrenches placed at each hydrant.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 20 May 2022
Resolved
Port and starboard RPM gauges are inoperable.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 August 2022
Resolution: Gauges were tested and are now operational.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 20 May 2022
Resolved
Port temperature gauge inoperable
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 August 2022
Resolution: Gauge was tested and is now operational.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 20 May 2022
Resolved
10 adult and 16 children's lifejackets need new retroreflective tape
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 August 2022
Resolution: Retro tape has been renewed.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 20 May 2022
Resolved
Bilge in E/R has excessive oil
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 August 2022
Resolution: Bilge has been cleaned out.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 May 2022
Resolved
Replace flexible fuel hoses; found cracked and weakened.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 August 2022
Resolution: Appropriate fuel hoses have been replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 20 May 2022
Resolved
Put blanks where old switches have been removed in the electrical box in the engine room.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 August 2022
Resolution: Blank has been placed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 May 2022
Resolved
Make pressure vessel available for inspection.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 August 2022
Resolution: P/V inspected
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 20 May 2022
Resolved
Supports for cables/wires in the engine room must be metallic. Several zip ties were found throughout.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 August 2022
Resolution: Supports have been fixed.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 13 July 2021
Resolved
bilge alarm E/R inoperable
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 July 2021
Resolution: bilge wire reconfigured and alarm operational
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 13 July 2021
Resolved
emergency lighting 1st deck inoperable
Action required: 705 - Other - as specified
Resolved 15 July 2021
Resolution: new lighting installed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 13 July 2021
Resolved
starboard generator engine oil and RPM gauge inoperable
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 September 2021
Resolution: new gauges installed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 13 July 2021
Resolved
Port generator RPM gauge inoperable
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 September 2021
Resolution: new gauges installed.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 13 July 2021
Resolved
Life ring light inoperable. Battery expired March 2021
Action required: 705 - Other - as specified
Resolved 16 July 2021
Resolution: New battery installed. Light operational.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 9 July 2020
Resolved
lifejacket stowage to be marked with number and type (adult, child)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 July 2020
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 12 August 2019
Resolved
Main deck bow hydrant valve leaks, and pipe to hose connection was missing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 September 2019
Resolved 28 August 2019
Resolution: Step repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 12 August 2019
Resolved
port and starboard engine RPM gauges inoperable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 September 2019
Resolved 28 August 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 12 August 2019
Resolved
batteries were found connected with wing nuts.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 September 2019
Resolved 24 September 2019
Resolution: Confirmed replaced
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 August 2019
Resolved
bridge deck broken weld on bottom rail.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 September 2019
Resolved 24 September 2019
Resolution: Weld repaired.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 12 August 2019
Resolved
bridge deck bottom step starboard side found severely corroded.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 September 2019
Resolved 7 October 2019
Resolution: step has been renewed.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 23 August 2018
Resolved
Emergency light located on aft second deck was unable to be adequately tested. Make available for testing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 18 September 2018
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 23 August 2018
Resolved
Portable lights must be located at the operating station and the access to propulsion machinery space.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 September 2018
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 23 August 2018
Resolved
2nd deck starboard aft outlet needs a cover
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 September 2018
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 23 August 2018
Resolved
Forward compartment overhead outlet is charred and has a shorted outlet.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 September 2018
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 August 2018
Resolved
Placards containing instructions for the donning and use of lifejackets onboard the vessel must be posted in conspicuous places visible to the crew and passengers.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 September 2018
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 23 August 2018
Resolved
Cap or plug unused pipes penetrating bulkhead on 2nd deck starboard side aft and forward.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 September 2018
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 24 May 2017
Resolved
Replace lifeline on bridge deck lifebuoy. Found worn and frayed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 June 2017
Resolved 22 June 2017
Resolution: Lifeline has been replaced.
Lifesaving › Lifejacket/PFD (Type II) › Retroreflective Material
Issued 24 May 2017
Resolved
Replace retro tape on 13 child size lifejackets.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 June 2017
Resolved 22 June 2017
Resolution: Retro tape has been renewed.
Lifesaving › Lifejacket/PFD (Type II) › Storage
Issued 24 May 2017
Resolved
Label child and adult lifejacket stowage boxes with the correct number of jackets.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 June 2017
Resolved 22 June 2017
Resolution: Stowage boxes labeled.
Electrical › Electrical Distribution System (service) › Panelboard
Issued 24 May 2017
Resolved
Electrical boxes in bow and engine room need latches.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 24 June 2017
Resolved 22 June 2017
Resolution: Latches have been installed.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 24 May 2017
Resolved
Repair MDE RPM, starboard generator RPM and starboard generator water temp gauges.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 June 2017
Resolved 22 June 2017
Resolution: Gauges operational.
Fire Fighting › Fire Hoses › Condition
Issued 25 August 2016
Resolved
01 fire hose located on first deck forward leaking excessively.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 September 2016
Resolved 29 August 2016
Resolution: new hose was purchased and replaced the leaking hose.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 25 August 2016
Resolved
02 emergency lights on second deck are inoperable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 August 2016
Resolved 26 August 2016
Resolution: One light was replaced, and the other the battery was replaced. Both operational.