MAURY USCG vessel records
← All vessels

SDLIMOBOAT

Built
1983
Last inspected
16 June 2026
Documentation
Expired · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 16 June 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDJ9524
228677
Flag
UNITED STATES
Maury page id
psix-228677

Documentation record

Registered dimensions (L × B × D)36.0 ft × 16.0 ft × 5.0 ft
Registered tonnagegross 20 / net 16
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDENNIS C. BUBNAR · PORT HUENEME, CA, UNITED STATES · built 1983
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portSAN DIEGO, CA
Endorsements, as the file codes themcw_un
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it16 - Simplified, Net Ton
20 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 20 inspections, each with its date, unit and type; 35 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 20

16 June 2026 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8406512
31 March 2026 Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8309534
22 April 2025 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8123617
21 May 2024 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7916340
3 April 2024 Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7889473
29 June 2023 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7726843
24 May 2022 COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7457277
2 March 2022 Hull Examination · Internal Structural Exam · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7404388
25 August 2021 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7284807
1 September 2020 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7043075
27 April 2020 Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6945307
16 March 2020 Deficiency Check · Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6927332
26 March 2019 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6649342
20 March 2019 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6646264
9 April 2018 Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6566429
26 March 2018 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6378635
11 April 2017 COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6122428
4 January 2017 COI Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6066046
7 April 2016 Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 5848483
29 March 2016 Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 5842453

Deficiency record · 35

08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 21 May 2024 Resolved
On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level. MI found that the bilge alarm light at the operating station was not installed. Install light for bilge alarm and notify local OCMI when complete.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 May 2024
Resolved 31 May 2024
Resolution: Received photo of alarm and light working from the operating station. All SAT.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 29 June 2023 Resolved
Each life jacket must be marked with Type I retroreflective material approved in 46 CFR 164.018. Replace retroreflective on 04 Life Jackets.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 4 July 2023
Resolution: O/O replaced retro on 04 life jackets.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 24 May 2022 Resolved
Vessel VHF DSC radio found to be programmed without MMSI information. Program radio to include MMSI
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 May 2022
Resolved 24 May 2022
Resolution: Programmed VHF-DSC radio with MMSI and GPS information.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 2 March 2022 Resolved
Port fwd corner of engine room bulkhead found to be delaminated. Repair delaminated section of bulkhead.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 10 May 2022
Resolution: Vessel POC removed damaged fiberglass and replaced with new. Fiberglass repair appeard to have a good secondary bond.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 2 March 2022 Resolved
Stern light lens found to be broken and missing. Repair stern light.
Action required: 705 - Other - as specified
Resolved 10 May 2022
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 25 August 2021 Resolved
Install operable VHF radio. Vessel is restricted from operationg > 1000' from land.
Action required: 705 - Other - as specified
Resolved 3 September 2021
Resolution: New radio installed in tested. Video received.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 25 August 2021 Resolved
Obtain FCC Safety Radio Certificate. Vessel is restricted from operating >1000' from land.
Action required: 705 - Other - as specified
Resolved 10 September 2021
Resolution: Picture of new FCC radio certificate received.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 25 August 2021 Resolved
Provide 01 portable hand bilge pump of >5 GPM.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 September 2021
Resolved 3 September 2021
Resolution: Picture of new bilge pump received.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 25 August 2021 Resolved
Replace or restock First Aid Kit meeting 46CFR 160.041.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 September 2021
Resolved 3 September 2021
Resolution: Picture of new first aid kit received.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 1 September 2020 Resolved
Properly install guard on serpentine belt in machinery space.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 October 2020
Resolved 18 November 2020
Resolution: Vessel Rep emailed picture of Guard installed.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 1 September 2020 Resolved
Trace all dead end wiring and cable to ensure everything is secured properly.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 October 2020
Resolved 29 September 2020
Resolution: Vessel rep emailed picture of all dead end wiring traced and labeled not in service. Deemed SAT.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 1 September 2020 Resolved
Clean out debris from Rakor filter bowl.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 October 2020
Resolved 29 September 2020
Resolution: Vessel rep emailed picture of cleaned Rakor filter bowl.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 1 September 2020 Resolved
Properly seal hatch on collision bulkhead.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 October 2020
Resolved 29 September 2020
Resolution: Vessel rep emailed pictures of hatch on collision bulkhead properly sealed.
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 1 September 2020 Resolved
Send us a copy of their updated crew list along with proof of pre-employment drug testing.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 October 2020
Resolved 29 September 2020
Resolution: Vessel rep emailed updated DAPI crew roster.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead strength
Issued 17 March 2020 Resolved
Repair engine compartment bulkhead on stbd side @ hull. Fiberglass seal has broken bond.
Action required: 705 - Other - as specified
Due 30 April 2020
Resolved 27 April 2020
Resolution: Repaired.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 17 March 2020 Resolved
Re-tab deck beams @ hull that have broken bond (stbd x4 / port x1).
Action required: 705 - Other - as specified
Due 30 April 2020
Resolved 27 April 2020
Resolution: Repaired.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 17 March 2020 Resolved
Clean bilge of all oil/debris.
Action required: 705 - Other - as specified
Due 30 April 2020
Resolved 27 April 2020
Resolution: Bilge found cleaned.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 26 March 2019 Resolved
Provide life buoy with lifeline.
Action required: 705 - Other - as specified
Due 9 April 2019
Resolved 9 April 2019
Resolution: Lifeline was provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 26 March 2019 Resolved
Repair leaking salt water pump.
Action required: 705 - Other - as specified
Due 9 April 2019
Resolved 9 April 2019
Resolution: New pump was isntalled.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 26 March 2019 Resolved
Make repairs to rudder post tube to remove flexible hose between packing gland and thru-hull penetration.
Action required: 705 - Other - as specified
Due 9 April 2019
Resolved 9 April 2019
Resolution: Satisfactory repairs were made.
02 - Structural Conditions › N/A - No Subsystem › Spaces in cargo areas
Issued 26 March 2019 Resolved
Secure all mooring cleats firmly to the vessel.
Action required: 705 - Other - as specified
Due 9 April 2019
Resolved 9 April 2019
Resolution: All cleates were securely fastened.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 26 March 2018 Resolved
Properly seperate adult and child sized life jackets.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 April 2018
Resolved 4 May 2018
Resolution: Life jackets seperated.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 26 March 2018 Resolved
Install aspirin and iodine in the first aid kit.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 April 2018
Resolved 4 May 2018
Resolution: First aid kit up to date.
Engineering › Diesel Engine (propulsion-reduction gear) › Air Cleaner
Issued 26 March 2018 Resolved
Properly secure the air intake housing on the MDE
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 May 2018
Resolved 4 May 2018
Resolution: New housing installed .
Engineering › Sea-water System (primary cooling) › Piping
Issued 26 March 2018 Resolved
Renew raw water discharge hose on MDE pump.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 May 2018
Resolved 4 May 2018
Resolution: Renewed the raw water hose.
Engineering › Fuel Oil Service System › Valve
Issued 26 March 2018 Resolved
properly label the emergency fuel cut-off valve location.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 April 2018
Resolved 4 May 2018
Engineering › Fuel Oil Service System › Valve
Issued 26 March 2018 Resolved
Re-design and demenstarte existing emergency cut-off valve mechanism
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 April 2018
Resolved 4 May 2018
Resolution: Witnessed proper operation of the emergency cut-off valve.
Navigation › Piloting/Steering › Magnetic Compass
Issued 26 March 2018 Resolved
Install a magnetic compass
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 April 2018
Resolved 4 May 2018
Resolution: Compass installed
Fire Fighting › Ventilation Systems › Ducts
Issued 26 March 2018 Resolved
Make engine compartment gastight and provide closures to prevent the admission of air during pre-engineered fixed sytem discharge.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 April 2018
Resolved 4 May 2018
Resolution: Engine compartment is gastight.
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 11 April 2017 Resolved
Provide name of the vessel on the PFDs, ring buoy and lifefloats to match the vessel name.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 June 2017
Resolved 29 June 2017
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 11 April 2017 Resolved
Provide anchor light.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 June 2017
Resolved 29 June 2017
Lifesaving › Lifebuoys › Size
Issued 11 April 2017 Resolved
Provide 24" ring bouy and bracket.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 June 2017
Resolved 29 June 2017
Electrical › Electric Supply System (service) › Battery Installation Ventilation
Issued 11 April 2017 Resolved
Provide ventilation for battery installation.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 29 June 2017
Resolved 29 June 2017
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 7 April 2016 Resolved
Provide service report for one fire extinguisher and Fireboy.
Action required: 705 - Other - as specified
Due 7 April 2016
Resolved 13 April 2016
Resolution: Service report provided.
Engineering › Sea-water System (primary cooling) › Valve
Issued 29 March 2016 Resolved
Repair or replace ball valve for MDE cooling water intake.
Action required: 705 - Other - as specified
Due 29 March 2016
Resolved 7 April 2016
Resolution: Ball valve replaced.

Ownership record