Records from 1984 to 1993. Most recent: inspection, 12 February 1993.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 27
12 February 1993
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 839323
10 December 1991
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1257171
25 October 1991
Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 937588
7 October 1991
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 939787
30 August 1990
Re-Inspection · Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1232796
7 November 1989
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1025490
6 October 1989
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1199839
4 January 1989
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1352883
25 October 1988
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 888123
18 October 1988
MARPOL Annex II Examination · Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 888294
28 June 1988
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1208110
6 June 1988
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1201606
12 May 1988
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1041496
13 April 1988
Hull Examination · Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1339725
5 November 1987
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1020859
6 October 1987
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1021027
23 December 1986
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1310128
18 November 1986
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1329360
1 August 1986
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1003536
28 May 1986
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1293350
15 May 1986
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 994287
11 December 1985
Deficiency Check · Credit Drydock
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 996062
9 November 1985
Deficiency Check
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1304230
6 October 1985
COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 988764
1 July 1985
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1288273
19 December 1984
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1284855
11 October 1984
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1284853
Fire Fighting
Issued 7 October 1991
Resolved
REMOVE EXISTING CONTROL PLAN HALON BOTTLE 100LB AND INSTALL 125LB WITH CURRENT DOT APPROVED HYDRO DATE AS PER C.O.I._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 October 1991
Resolved 7 October 1991
Fire Fighting
Issued 7 October 1991
Resolved
RENEW IN LIKE KIND AND QUALITY OR DEMONSTRATE PROPER OPERATION OF 12FT FIREAPPLICATOR ON HELO DECK._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 October 1991
Resolved 7 October 1991
Fire Fighting
Issued 7 October 1991
Resolved
PROVIDE REQUIRED SERVICING FOR HYDRO TEST OF PAINT LOCKER FIXED CO2 SYSTEM._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 October 1991
Resolved 7 October 1991
Engineering
Issued 7 October 1991
Resolved
MAKE SAFETY VALVES AVAILABLE FOR SETTING AND SEALING ON THE 4 AUX. BOILERS,CLEAVER BROOKS PORT AND STBD. AND CLAYTON LOS 81-147 AND LOS 81-148. TO BE COMPLETED TO THE SATISFACTION OF ATTENDING USCG MARINE INSPECTOR._x001C_ _x001C_
Condition: Unknown
Due 7 October 1991
Resolved 7 October 1991
Lifesaving
Issued 7 October 1991
Resolved
DEMONSTRATE PROPER OPERATION OF SHALE SHAKER NR21 H2S SENSOR._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 October 1991
Resolved 7 October 1991
Engineering
Issued 7 October 1991
Resolved
RENEW IN LIKE KIND AND QUALITY 6 RACOR FUEL FILTER SHIELDS TO NR3 DIESEL AND EMERG GENERATOR, 3 EACH.
Condition: Unknown
Due 7 October 1991
Resolved 7 October 1991
Electrical
Issued 7 October 1991
Resolved
RENEW IN LIKE KIND AND QUALITY AS ORIGINAL EMERGENCY GENERATOR BATTERIES (40 BLOCK CELL SYSTEM, 24 VOLTS).
Condition: Unknown
Due 7 October 1991
Resolved 7 October 1991
Electrical
Issued 7 October 1991
Resolved
RENEW IN LIKE KIND AND QUALITY AS ORIGINAL UNINTERRUPTIBLE POWER SUPPLY BATTERY SYSTEM.(100 BLOCK CELL SYSTEM, 120 VOLTS DC)
Condition: Unknown
Due 7 October 1991
Resolved 7 October 1991
Electrical
Issued 7 October 1991
Resolved
PERMANENTLY INSTALL EMERGENCY BATTERY LIGHT FIXTURE IN PASSAGEWAY FROM CREWQUARTERS TO ELECTRICAL SHOP._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 October 1991
Resolved 7 October 1991
Lifesaving
Issued 7 October 1991
Resolved
DEMONSTRATE PROPER OPERATION OF SHALE SHAKER LOSS OF PURGE ALARM BY VISUAL OR AUDIBLE, MUST BE READILY SEEN OR HEARD._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 October 1991
Resolved 7 October 1991
Engineering
Issued 7 October 1991
Resolved
RENEW IN LIKE KIND AS ORIGINAL AND DEMONSTRATE PROPER OPERATION OF 4 PRESSURE VESSELS RELIEFS FOR RTP 5.10 #1/TANK 1262, STB APV #1/TANK 1112, STB APV #2/TANK 1111 AND STB APV #3/TANK 1114. PRESSURE VESSELS NOT TO BE USED UNTIL PROPER RELIEFS VALVES FITTED AND TESTED.
Condition: Unknown
Due 7 October 1991
Resolved 7 October 1991
Lifesaving
Issued 7 October 1991
Resolved
CONDUCT OPERATIONAL UNDERWAY TESTS OF LIFE BOATS NR 1,2,3, AND 4._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 October 1991
Resolved 7 October 1991
Documentation
Issued 7 October 1991
Resolved
PROVIDE [name withheld] OF APPROVAL DATE AND CG PORT OF APPROVAL FOR CONSTRUCTION PORTFOLIO 46 CFR 305(HH)._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 October 1991
Resolved 7 October 1991
Lifesaving
Issued 7 October 1991
Resolved
DEMONSTRATE PROPER OPERATION OF SUSPENSION/RELEASE GEAR, ENG AHEAD/ASTERN, ENG COOLING WATER, WATER SPRAY SYSTEM ON NR 1,2,3, AND 4 LIFEBOATS WHILE CONDUCTING UNDERWAY TESTS._x001C_ _x001C_
Condition: Unknown
Due 7 October 1991
Resolved 7 October 1991
Documentation
Issued 7 October 1991
Resolved
PROVIDE [name withheld] OF ANNUAL INSPECTION/TESTS OF 2 MAIN/2 AUX CRANESCONDUCTED BY ABS DURING OCT 91.
Condition: Unknown
Due 7 October 1991
Resolved 7 October 1991
Lifesaving
Issued 7 October 1991
Resolved
PROVIDE REQUIRED ANNUAL SERVICING FOR HYDROSTATIC RELEASE UNITS ON LR STATIONS NR1 AND NR3 OR REPLACE WITH UNITS CURRENTLY IN SERVICE.
Condition: Unknown
Due 7 October 1991
Resolved 7 October 1991
Lifesaving
Issued 7 October 1991
Resolved
PROVIDE [name withheld] OF CERTIFICATES FOR 3 BFG LIFERAFTS SER 10/LOT29,SER 8/LOT29 AND SER 13/LOT32 FROM D.O.T. APPROVED FACILITY.
Condition: Unknown
Due 7 October 1991
Resolved 7 October 1991
Lifesaving
Issued 7 October 1991
Resolved
DEMONSTRATE PROPER OPERATION OF LIFEBOATS PORTABLE RADIO'S SER NR 5183, 5172 AND 5187.
Condition: Unknown
Due 7 October 1991
Resolved 7 October 1991
Lifesaving
Issued 7 October 1991
Resolved
RENEW IN LIKE KIND AND QUALITY AS ORIGINAL 12 HAND HELD FLARES FOR CONTROL ROOM._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 October 1991
Resolved 7 October 1991
Engineering
Issued 30 August 1990
Resolved
MAKE ASME PRESSURE VESSELS NUMBER 997405 AND 991416 (LOW PRESSURE COMPRESSOR AIR DRYERS) AVAILABLE FOR U.S. COAST GUARD INTERNAL EXAMINATION.
Condition: Unknown
Due 30 August 1990
Resolved 30 August 1990
Lifesaving
Issued 30 August 1990
Resolved
CONDUCT HYDROSTATIC TEST ON ALL LIFEBOAT ESCAPE AIR BOTTLES. SUBMIT RESULTS TO U.S. COAST GUARD MARINE SAFETY DETACHMENT SANTA BARBARA, CA.
Condition: Unknown
Due 30 August 1990
Resolved 30 August 1990
Construction/Loadline
Issued 30 August 1990
Resolved
PROVIDE COPIES OF HOUSTON GEOSCAN GUAGING REPORT, DIVERS SURVEY AND VIDEO TAPE OF UNDERWATER INSPECTION TO U.S. COAST GUARD MARINE SAFETY DETACHMENT SANTA BARBARA (111 HARBOR WAY / SANTA BARBARA, CA 93109-2315)
Condition: Unknown
Due 30 August 1990
Resolved 30 August 1990
Lifesaving
Issued 6 October 1989
Resolved
CONDUCT FIRE AND BOAT DRILLS WITHIN ONE WEEK OF TAKING ON INDUSTRIAL PERSONNEL.
Condition: Unknown
Due 6 October 1989
Resolved 6 October 1989
Fire Fighting
Issued 6 October 1989
Resolved
DEMONSTRATE PROPER OPERATION OF THE FIRE SCREEN DOOR BORDERING LIVING SPACEPORT SIDE AND MAIN DECK MACHINERY SPACE WITH INBOARD DOOR CLOSED.
Condition: Unknown
Due 6 October 1989
Resolved 6 October 1989
Construction/Loadline
Issued 6 October 1989
Resolved
REPAIR FRACTURED GREASE PIPE PENETRATION OF PORT AFT PONTOON AT THE 51 FT LEVEL.
Condition: Unknown
Due 6 October 1989
Resolved 6 October 1989
Deck/Cargo
Issued 6 October 1989
Resolved
REPAIR FRACTURED PIPE RACK STBD SIDE OF MAIN DECK OUTBOARD SIDE, AT 3" PIPEBRACE AT WEB OF EYE BEAMS.
Condition: Unknown
Due 6 October 1989
Resolved 6 October 1989
Engineering
Issued 18 October 1988
Resolved
RENEW AND PROVE RELIEF VALVE ON INBOARD CLAYTON STEAM HEATING BOILER.
Condition: Unknown
Due 18 October 1988
Resolved 18 October 1988
Engineering
Issued 18 October 1988
Resolved
REPAIR AND PROVE PORT AND STARBOARD EMERGENCY FUEL SHUTDOWNS.
Condition: Unknown
Due 18 October 1988
Resolved 18 October 1988
Fire Fighting
Issued 18 October 1988
Resolved
HYDRO TEST FOUR PORTABLE CO2 EXTINGUISHERS.
Condition: Unknown
Due 18 October 1988
Resolved 18 October 1988
Lifesaving
Issued 18 October 1988
Resolved
RENEW FOUR ORANGE SMOKE FOR LIFEBOATS.
Condition: Unknown
Due 18 October 1988
Resolved 18 October 1988
Lifesaving
Issued 18 October 1988
Resolved
REPLACE ONE BUOYANT ROCKET FOR LINE THROWING GUN.
Condition: Unknown
Due 18 October 1988
Resolved 18 October 1988
Construction/Loadline
Issued 13 April 1988
Resolved
PROVIDE A COPY OF UNDERWATER SURVEY VIDEO TAPE AND REPORT TO THIS OFFICE.
Condition: Unknown
Due 13 April 1988
Resolved 13 April 1988
Documentation
Issued 13 April 1988
Resolved
REPLACE, MODIFY OR REMOVE OILY WATER SEPARATOR TO COMPLY WITH MARPOL 73/78 STANDARDS.
Condition: Unknown
Due 13 April 1988
Resolved 13 April 1988
Lifesaving
Issued 13 April 1988
Resolved
CONDUCT OPERATIONAL TEST OF LIFEBOAT NUMBER 1, RELEASE TESTS FOR LIFEBOATS 1, 3, AND 4 AND SPRINKLER TEST OF NUMBER 2.
Condition: Unknown
Due 13 April 1988
Resolved 13 April 1988
Fire Fighting
Issued 13 April 1988
Resolved
PROVIDE USCG APPROVED PLAN AND VENDORS SERVICE MANUAL FOR FIXED CO2 SYSTEM.
Condition: Unknown
Due 13 April 1988
Resolved 13 April 1988
Lifesaving
Issued 13 April 1988
Resolved
CONDUCT FIRE AND BOAT DRILL WITH REGULAR CREW.
Condition: Unknown
Due 13 April 1988
Resolved 13 April 1988
Lifesaving
Issued 13 April 1988
Resolved
REPLACE ALL MILK IN ALL FOUR LIFEBOATS (16 OZ. PER PERSON).
Condition: Unknown
Due 13 April 1988
Resolved 13 April 1988
Unknown
Issued 6 October 1987
Resolved
COMPLETE WORKLIST ITEMS 1-28 PRIOR TO CONDUCTING DRILL OPERATIONS OR MOVINGFROM THE AREA OF PORT HUENEME. TOTAL PERSONS ON BOARD IS LIMITED TO 54.
Condition: Unknown
Due 6 October 1987
Resolved 6 October 1987
Documentation
Issued 6 October 1987
Resolved
AMEND THE CERTIFICATE OF DOCUMENTATION TO REFLECT CHANGE OF ADDRESS.
Condition: Unknown
Due 6 October 1987
Resolved 6 October 1987
Fire Fighting
Issued 6 October 1987
Resolved
TEST THE FIXED CO2 SYSTEM FOR THE EMERGENCY GENERATOR.
Condition: Unknown
Due 6 October 1987
Resolved 6 October 1987
Fire Fighting
Issued 6 October 1987
Resolved
TEST THE FIXED HALON SYSTEMS.
Condition: Unknown
Due 6 October 1987
Resolved 6 October 1987
Documentation
Issued 6 October 1987
Resolved
RESOLVE WHETHER THE SEDCO 712 IS TO BE CERTIFICATED AS SELF-PROPELLED OR PROPULSION-ASSISTED.
Condition: Unknown
Due 6 October 1987
Resolved 6 October 1987
Navigation
Issued 6 October 1987
Resolved
CONDUCT A LIAISON MEETING WITH THE PORT AUTHORITY FOR PORT HUENEME, PILOTS ASSOCIATION, CRAIG FUSARO (FISHING LIAISON) ATTENDED BY COAST GUARD TO ADDRESS THE LOCATION OF THE RIG.
Condition: Unknown
Due 6 October 1987
Resolved 6 October 1987
Construction/Loadline
Issued 18 November 1986
Resolved
TIE-DOWNS FOR HELICOPTERS ARE TO BE RECESSED.
Condition: Unknown
Due 18 November 1986
Resolved 18 November 1986
Fire Fighting
Issued 18 November 1986
Resolved
FURNISH NAPHTHA FOR FLAME SAFETY LAMPS.
Condition: Unknown
Due 18 November 1986
Resolved 18 November 1986
Construction/Loadline
Issued 18 November 1986
Resolved
REPAIR CRACK IN WELD, DECKHOUSE TO MAIN DECK, FORWARD PORTSIDE.
Condition: Unknown
Due 18 November 1986
Resolved 18 November 1986
Accommodation/Occupational Safety
Issued 18 November 1986
Resolved
FREE UP PULLEYS ON OUTSIDE FIRE DAMPERS.
Condition: Unknown
Due 18 November 1986
Resolved 18 November 1986
Construction/Loadline
Issued 18 November 1986
Resolved
PRVIDE HELO DECK WITH NON-SKID SURFACE.
Condition: Unknown
Due 18 November 1986
Resolved 18 November 1986
Lifesaving
Issued 18 November 1986
Resolved
STENCIL LIFE RAFTS WITH CAPACITY OF PERSONS ALLOWED.
Condition: Unknown
Due 18 November 1986
Resolved 18 November 1986
Lifesaving
Issued 9 November 1985
Resolved
WEIGHT TEST FOR AND AFT LIFERAFT LAUNCHING DAVITS. PRIOR TO 06DEC85.
Condition: Unknown
Due 9 November 1985
Resolved 9 November 1985
Fire Fighting
Issued 9 November 1985
Resolved
RECHARGE AND INSTALL ONE (1) 100 LBS. CO2 BOTTLE SERIAL #17122EK FOR THE MAIN CO2 ROOM. THE ABOVE TO BE COMPLETED PRIOR TO 06DEC85 TO THE SATISFACTION OF THE ATTENDING C.G. INSPECTOR.
Condition: Unknown
Due 9 November 1985
Resolved 9 November 1985
Lifesaving
Issued 9 November 1985
Resolved
WEIGHT TEST ALL LIFEBOATS, RESCUE BOAT AND THEIR DAVITS AND PROVE SATISFACTORY OPERATION OF EACH RELEASING GEAR. PRIOR TO 06DEC85.
Condition: Unknown
Due 9 November 1985
Resolved 9 November 1985
Lifesaving
Issued 9 November 1985
Resolved
PROVE SATISFACTORY OPERATION OF EACH LIFEBOAT WATER SCREEN SYSTEM. PRIOR TO 06DEC85.
Condition: Unknown
Due 9 November 1985
Resolved 9 November 1985
Fire Fighting
Issued 6 October 1985
Resolved
RECHARGE AND INSTALL THREE (3) 100 LB. CO2 CYLINDERS IN MAIN CO2 ROOM.
Condition: Unknown
Due 6 October 1985
Resolved 6 October 1985
Documentation
Issued 6 October 1985
Resolved
FCC EXEMPTION CERTIFICATE (FORM 821) EXPIRED.
Condition: Unknown
Due 6 October 1985
Resolved 6 October 1985
Fire Fighting
Issued 6 October 1985
Resolved
FOAM SAMPLE TO BE SUBMITTED TO MANUFACTURER FOR ANALYSIS.
Condition: Unknown
Due 6 October 1985
Resolved 6 October 1985
Lifesaving
Issued 6 October 1985
Resolved
WEIGHT TEST ALL LIFEBOATS, RESCUE BOATS AND THEIR DAVITS AND PROVE SATISFACTORY OPERATION OF EACH RELEASING GEAR.
Condition: Unknown
Due 6 October 1985
Resolved 6 October 1985
Lifesaving
Issued 6 October 1985
Resolved
PROVE SATISFACTORY OPERATION OF EACH LIFEBOAT WATER SCREEN SYSTEM.
Condition: Unknown
Due 6 October 1985
Resolved 6 October 1985
Fire Fighting
Issued 6 October 1985
Resolved
PROVIDE A PORTABLE FIRE EXTINGUISHER AND AN AUDIBLE WARNING DEVICE FOR VESSEL'S FORK LIFT TRUCK.
Condition: Unknown
Due 6 October 1985
Resolved 6 October 1985
Lifesaving
Issued 6 October 1985
Resolved
PROVIDE WHISTLES AND/OR LIGHTS FOR 26 LIFE PRESERVERS.
Condition: Unknown
Due 6 October 1985
Resolved 6 October 1985
Construction/Loadline
Issued 6 October 1985
Resolved
MAKE VARIOUS INTERNAL COMPARTMENTS AVAILABLE FOR EXAMINATION AT NEXT DRYDOCK INSPECTION.
Condition: Unknown
Due 6 October 1985
Resolved 6 October 1985
Fire Fighting
Issued 6 October 1985
Resolved
PROVIDE AND INSTALL TAGS AND SEALS FOR ALL FIRE EXTINGUISHERS.
Condition: Unknown
Due 6 October 1985
Resolved 6 October 1985
Fire Fighting
Issued 6 October 1985
Resolved
PROVIDE AND POST LOCAL CONTROL OPERATING INSTRUCTIONS FOR BOTH THRUSTER HALON SYSTEMS.
Condition: Unknown
Due 6 October 1985
Resolved 6 October 1985
Lifesaving
Issued 6 October 1985
Resolved
WEIGHT TEST FORE AND AFT LIFERAFT LAUNCHING DAVITS.
Condition: Unknown
Due 6 October 1985
Resolved 6 October 1985
Lifesaving
Issued 6 October 1985
Resolved
PROVIDE AND INSTALL ONE GLOBE FOR THE LANTERN IN THE NUMBER ONE (#1) LIFEBOAT.
Condition: Unknown
Due 6 October 1985
Resolved 6 October 1985
Lifesaving
Issued 1 July 1985
Resolved
CRACKS IN FIBREGLASS TO#3 LIFE BOAT
Condition: Unknown
Due 1 July 1985
Resolved 1 July 1985
Lifesaving
Issued 1 July 1985
Resolved
MAKE PREMANENT REPAIRS TO 2"X2" HOLE IN WAY OF LIFE BOAT #4 COVERAT STERN STBD. CORNER.
Condition: Unknown
Due 1 July 1985
Resolved 1 July 1985
Construction/Loadline
Issued 11 October 1984
Resolved
PROVE REMOTE OPERATION OF WATERTIGHT DOORS IN THE STBD. FWD COLUMN.
Condition: Unknown
Due 11 October 1984
Resolved 11 October 1984
Deck/Cargo
Issued 11 October 1984
Resolved
REMOTE ACTUATED BILGE VALVES FROZEN
Condition: Unknown
Due 11 October 1984
Resolved 11 October 1984
Deck/Cargo
Issued 11 October 1984
Resolved
PROVE OPERATION OF BILGE HIGH LEVEL ALARMS IN STBD FWD COLUMN AND STBD PUMP ROOM
Condition: Unknown
Due 11 October 1984
Resolved 11 October 1984