Records from 1985 to 2007. Most recent: inspection, 19 December 2007.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 80
19 December 2007
Type not recorded
No type recorded · Commandant (CG-CVC) · Activity 3118303
25 April 2007
Administrative Inspection
Administrative · Activities Europe · Activity 2915196
20 March 2006
In-Service Inspection · Deficiency Check
Physical examination · Activities Europe · Activity 2607187
9 January 2006
COI Inspection · Hull Examination · MARPOL Annex I Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2567790
21 March 2005
Annual Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2310605
28 April 2004
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2054863
18 November 2003
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1958674
7 July 2003
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1838402
24 March 2003
Annual Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1760806
26 August 2002
Administrative Inspection
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1666727
15 March 2002
Annual Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1492292
5 December 2001
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 772809
2 December 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 772689
8 August 2001
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1069422
21 June 2001
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1067316
1 June 2001
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 62985
15 May 2001
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1063407
16 April 2001
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1063002
16 March 2001
COI Inspection · Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1425094
31 July 2000
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 771150
30 July 2000
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 204025
2 June 2000
Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1440332
24 November 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 811533
9 November 1999
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 164877
25 October 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 792854
30 June 1999
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1083712
28 March 1999
COI Inspection
Physical examination · Activities Europe · Activity 1365140
17 July 1998
Deficiency Check
Physical examination · Activities Europe · Activity 1129588
8 June 1998
Deficiency Check
Physical examination · Activities Europe · Activity 1127685
24 April 1998
Deficiency Check · Re-Inspection
Physical examination · Activities Europe · Activity 1368715
11 March 1998
Hull Examination
Physical examination · Activities Europe · Activity 1368738
12 January 1998
Deficiency Check
Physical examination · Activities Europe · Activity 1121434
2 December 1997
Administrative
Administrative · Activities Europe · Activity 775587
17 October 1997
Type not recorded
No type recorded · Activities Europe · Activity 775743
23 September 1997
Administrative
Administrative · Activities Europe · Activity 1112841
11 June 1997
Administrative
Administrative · Activities Europe · Activity 775463
28 May 1997
Administrative
Administrative · Activities Europe · Activity 1109104
27 May 1997
Type not recorded
No type recorded · Activities Europe · Activity 1108435
21 April 1997
Type not recorded
No type recorded · Activities Europe · Activity 1110149
3 April 1997
COI Inspection
Physical examination · Activities Europe · Activity 1413147
12 March 1997
Plan Review "T" Boat
Administrative · Activities Europe · Activity 1102894
11 February 1997
Administrative
Administrative · Activities Europe · Activity 1103811
11 February 1997
Administrative
Administrative · Activities Europe · Activity 1103813
24 September 1996
Administrative
Administrative · Activities Europe · Activity 1137620
10 July 1996
Deficiency Check
Physical examination · Activities Europe · Activity 1087083
10 July 1996
Administrative
Administrative · Activities Europe · Activity 1087086
1 June 1996
Administrative
Administrative · Activities Europe · Activity 1084941
4 March 1996
Deficiency Check
Physical examination · Activities Europe - OLD · USCG Northeast District (CGD-NE) · Activity 1355693
9 January 1996
Hull Examination · Re-Inspection
Physical examination · Activities Europe - OLD · USCG Northeast District (CGD-NE) · Activity 1470909
28 December 1995
Type not recorded
No type recorded · Activities Europe - OLD · USCG Northeast District (CGD-NE) · Activity 1353842
11 May 1995
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 909658
6 April 1995
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 862971
10 April 1994
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1170092
22 May 1993
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 848580
22 April 1993
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1158881
13 January 1993
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1137541
11 April 1992
Deficiency Check · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1261591
13 September 1991
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 939749
26 April 1991
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1252213
14 April 1991
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 915253
12 April 1991
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 921518
2 April 1991
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1236214
6 June 1990
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1246830
2 May 1990
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1220768
20 March 1990
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 908627
20 July 1989
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 906335
27 May 1989
COI Inspection · Drydock Extension
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1210952
16 March 1989
Drydock Extension
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1034949
22 November 1988
Drydock Extension
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 895399
25 July 1988
Drydock Extension · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1351202
14 March 1988
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1029588
19 October 1987
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1016029
21 September 1987
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1006494
6 July 1987
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1319103
9 June 1987
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1029807
27 May 1987
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1336335
31 March 1987
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1020423
2 February 1987
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1311263
31 December 1986
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1029458
6 June 1985
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 985238
Electrical › Electric Generation Source (emergency) › Generator
Issued 13 January 2006
Resolved
Prove automatic startup of emergency generator and starting x6.
Action required: 705 - Other - as specified
Due 13 February 2006
Resolved 20 January 2006
Resolution: Started automatically and 5 additional times within 30 minutes.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 13 January 2006
Resolved
Prove proper operation of ship's switchboard and associated appliances.
Action required: 705 - Other - as specified
Due 13 February 2006
Resolved 20 January 2006
Resolution: Proved proper operation and transfer of all switchboard appliances.
Electrical › Lighting (emergency) › Lighting Feeder
Issued 13 January 2006
Resolved
Prove operation of emergency lighting.
Action required: 705 - Other - as specified
Due 13 January 2006
Resolved 20 January 2006
Resolution: Proved operation of emergency lighting
Electrical › Electrical Distribution System (service) › Wiring
Issued 13 January 2006
Resolved
Prove operation of freezer alarm.
Action required: 705 - Other - as specified
Due 13 February 2006
Resolved 15 January 2006
Resolution: Repaired alarm.
Lifesaving › Lifeboat › Markings
Issued 13 January 2006
Resolved
Replace all faded and peeling life pod retro reflective tape to the satisfaction of Marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 February 2006
Resolved 14 January 2006
Resolution: Replaced peeling and faded tape.
Electrical › Electric Generation Source (service) › Generator
Issued 13 January 2006
Resolved
Unavailable for inspection due to rebuild. Inspect all safety devices.
Action required: 705 - Other - as specified
Due 13 February 2006
Resolved 20 January 2006
Resolution: Generator ran and all safety devices tested.
Accommodation/Occupational Safety › Ventilation › General
Issued 13 January 2006
Resolved
Prove emergency drilling operations ventilation stop.
Action required: 705 - Other - as specified
Due 13 February 2006
Resolved 20 January 2006
Resolution: Proved drilling vent stop.
Accommodation/Occupational Safety › Ventilation › General
Issued 13 January 2006
Resolved
Prove fuel system shutdown via ventilation from rig floor.
Action required: 705 - Other - as specified
Due 13 February 2006
Resolved 20 January 2006
Resolution: Proved fuel shutdown remotely using ventilation shutdown from rig floor.
Accommodation/Occupational Safety › Ventilation › General
Issued 13 January 2006
Resolved
Prove general ventilation shutdown from rig floor.
Action required: 705 - Other - as specified
Due 13 February 2006
Resolved 20 January 2006
Resolution: Proved general ventilation shutdown from rig floor.
Lifesaving › Visual Distress Signals (General) › Expired
Issued 13 January 2006
Resolved
Batteries out of date in epirb. Renew.
Action required: 705 - Other - as specified
Due 13 February 2006
Resolved 13 February 2006
Resolution: Extended date due to transit.
Accommodation/Occupational Safety › Ventilation › General
Issued 13 January 2006
Resolved
Test purge alarms iaw NFPA 496
Action required: 705 - Other - as specified
Due 13 February 2006
Resolved 20 January 2006
Resolution: Tested purge alarms iaw regs.
Accommodation/Occupational Safety › Sleeping Accommodations › Berth
Issued 13 January 2006
Resolved
Prove bunk lights in accommodation spaces.
Action required: 705 - Other - as specified
Due 13 February 2006
Resolved 15 January 2006
Resolution: Replaced covers on all lights.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 13 January 2006
Resolved
Stair tower doors must shut automatically.
Action required: 705 - Other - as specified
Due 13 February 2006
Resolved 16 January 2006
Resolution: Adjusted doors.
Construction/Loadline › Structures › Ventilators
Issued 13 January 2006
Resolved
04 deck ventilation shutdowns all frozen handles or rusted hinges. Replace/repair all.
Condition: Improper/Lack of Maintenance
Due 13 February 2006
Resolved 15 January 2006
Resolution: Repaired all defective components.
Electrical › Lighting (service) › Lighting Fixture
Issued 13 January 2006
Resolved
Crane systems do not have panel illumination. Install red lights for night operations.
Action required: 705 - Other - as specified
Due 13 February 2006
Resolved 13 February 2006
Resolution: Extended date due to transit.
Electrical › Electrical Distribution System (service) › Switch
Issued 13 January 2006
Resolved
Inspect and prove proper operation of all lifeboat limit switches.
Due 13 February 2006
Resolved 13 January 2006
Resolution: Opened all switches and cleaned/repaired all.
Documentation › Safety/Response Plans/Programs › Fire Control Plans
Issued 13 January 2006
Resolved
Update fire control plan and provide revision for marine inspector.
Due 13 February 2006
Resolved 20 January 2006
Resolution: provided updated plans to reflect vessel arrangements.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 13 January 2006
Resolved
Replace 2 ea 30lb co2's at stations #38 and 40 and one 50lb co2 semi portable #72 on the heliport iaw the third party servicing report of firefighting equipment.
Due 13 February 2006
Resolved 14 January 2006
Resolution: Replaced all three extinguishers.
Personnel › Training › Fire Fighting Basic
Issued 13 January 2006
Resolved
Conduct fire, boat and abandon ship drills.
Due 13 February 2006
Resolved 20 January 2006
Resolution: Conducted satisfactory drills and training.
Communications › Radio Communications › EPIRB
Issued 9 January 2006
Resolved
Prove battery and registration iaw regulations.
Action required: 705 - Other - as specified
Due 15 March 2006
Resolved 20 March 2006
Resolution: inspected the EPIRD, Sat.
Deck/Cargo › Cargo Stowage › General
Issued 9 January 2006
Resolved
Provide illumination for crane houses for control panels iaw regulations.
Action required: 705 - Other - as specified
Due 15 March 2006
Resolved 20 March 2006
Resolution: Sat.
Construction/Loadline › Hull
Issued 21 March 2003
Resolved
Complete phase II portion of SEILOD at next rig move to include NDT of leg to can connections. LEGACY COMPONENT DESC: Hull Plating
Condition: Unknown
Due 25 April 2003
Resolved 7 July 2003
Lifesaving › Lifeboat › Embarkation/Disembarkation Capabilities
Issued 21 March 2003
Resolved
Prove proper operation of releasing gear on both lifeboats.
Condition: Improper/Lack of Maintenance
Due 20 April 2003
Resolved 31 March 2003
Lifesaving › Lifeboat › Fire Protection (water spray system)
Issued 21 March 2003
Resolved
Prove proper operation of sprinkler on #1 lifeboat.
Condition: Improper/Lack of Maintenance
Due 25 April 2003
Resolved 31 March 2003
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 21 March 2003
Resolved
Prove synchronization of obstruction lights.
Condition: Improper/Lack of Maintenance
Due 30 March 2003
Resolved 31 March 2003
Construction/Loadline
Issued 16 March 2001
Resolved
CONDUCT PHASE II SEIODD.
Condition: Unknown
Due 16 March 2001
Resolved 16 March 2001
Lifesaving
Issued 2 June 2000
Resolved
Repair brake release electric conduit for #4 life raft as per 46 CFR 111.70.
Condition: Unknown
Due 30 June 2000
Resolved 3 July 2000
Electrical
Issued 2 June 2000
Resolved
Prove proper operation of emergency generator room intake air damper.
Condition: Unknown
Due 2 June 2000
Resolved 2 June 2000
Fire Fighting
Issued 2 June 2000
Resolved
Replace fire main gauge on starboard manifold located on forward bulkhead.
Condition: Unknown
Due 30 June 2000
Resolved 3 July 2000
Electrical
Issued 2 June 2000
Resolved
Permanently correct overheating SCR's and close all electrical panel's as per 46 CFR 111.40-5.
Condition: Unknown
Due 2 June 2000
Resolved 2 June 2000
Electrical
Issued 2 June 2000
Resolved
Remove dead end electrical cable on upper drill floor wire tray as per 46 CFR 111.30-25(4).
Condition: Unknown
Due 30 June 2000
Resolved 3 July 2000
Lifesaving
Issued 2 June 2000
Resolved
Conduct operational test of lifeboat releasing gear in the presence of Coast Guard Inspector as per 46 CFR 109.301(i)(5).
Condition: Unknown
Due 30 June 2000
Resolved 3 July 2000
Electrical
Issued 2 June 2000
Resolved
Replace broken ammeter on raw water pump controller as per 46 CFR 111.30- 25(4).
Condition: Unknown
Due 30 June 2000
Resolved 3 July 2000
Electrical
Issued 2 June 2000
Resolved
Install protective exhaust lagging on all generator engines as per 46 CFR 56.50-10(k).
Condition: Unknown
Due 30 June 2000
Resolved 3 July 2000
Electrical
Issued 2 June 2000
Resolved
Prove operation of the following items on generators: overspeed protection,low lube oil pressure shutdowns, and reverse power relays.
Condition: Unknown
Due 30 June 2000
Resolved 3 July 2000
Electrical
Issued 2 June 2000
Resolved
Replace wiring for bow jib boom with permanent and properly mounted cab- missling as per 46 CFR 111.60.
Condition: Unknown
Due 2 June 2000
Resolved 2 June 2000
Engineering
Issued 2 June 2000
Resolved
Stencil fuel oil transfer hose as per 33 CFR 155.800 with 1.5 MAWP.
Condition: Unknown
Due 30 June 2000
Resolved 3 July 2000
Accommodation/Occupational Safety
Issued 2 June 2000
Resolved
Prove operation of relief valves for all pressure vessels as per 46 CFR 15-10.
Condition: Unknown
Due 30 June 2000
Resolved 3 July 2000
Electrical
Issued 28 March 1999
Resolved
Repair and test "TOTAL RIG SHUTDOWN". Notify USCG MIO Europe via fax upon completion of the above requirement.
Condition: Unknown
Due 12 April 1999
Resolved 12 April 1999
Documentation
Issued 8 June 1998
Resolved
Bring vessel into full compliance with the new revisions to Subchapter I-A in 46 CFR, specifically 108.901 (MUSTER LIST AND EMERGENCY INSTRUCTIONS).
Condition: Unknown
Due 8 June 1998
Resolved 8 June 1998
Construction/Loadline
Issued 11 March 1998
Resolved
Provide all preload dump valves for inspection or documentation that a selfinspection and maintenance has been initiated.
Condition: Unknown
Due 13 May 1998
Resolved 13 May 1998
Construction/Loadline
Issued 11 March 1998
Resolved
Provide hull bottom for inspection.
Condition: Unknown
Due 13 May 1998
Resolved 13 May 1998
Documentation
Issued 17 October 1997
Resolved
Conduct USCG witnessed deadweight survey IAW letter H1-9700990 dtd 08 April1997.
Condition: Unknown
Due 17 October 1997
Resolved 17 October 1997
Lifesaving
Issued 23 September 1997
Resolved
Bring vessel into full compliance with the new revisions to Subchapter I-A in 46 CFR, specifically: 108.901 and 109.213.
Condition: Unknown
Due 23 September 1997
Resolved 23 September 1997
Construction/Loadline
Issued 27 May 1997
Resolved
PROVIDE SAT. DOCUMENTATION OF NDE OF FOLLOWING AREAS; GUSSETS IN WAY OF LEGTO PORT CAN, CHORD "K" AND "L". PROVIDE COPY OF NDT REPORT BY ABS CERTIFIED TECHNICIAN.
Condition: Unknown
Due 27 May 1997
Resolved 27 May 1997
Unknown
Issued 21 April 1997
Resolved
Conduct USCG witnessed deadweight survey IAW letter H1-9700990 dtd 08 April1997. Survey to be conducted NLT 22 May 97.
Condition: Unknown
Due 21 April 1997
Resolved 21 April 1997
Unknown
Issued 3 April 1997
Resolved
Bring vessel into full compliance with the new revisions to Subchapter I-A in 46 CFR, specifically: 107.305, 108.575, 108.580, 108.645, 108.646, 108.647, 108.649(b)(d)(f)&(g), 108.655, 108.901 and 109.213. See enclosure(1) of EURMI letter 16711/ROWAN CALIFORNIA, 09APR97, for details.
Condition: Unknown
Due 3 April 1997
Resolved 3 April 1997
Documentation
Issued 1 June 1996
Resolved
SUBMIT PLANS TO G-MSC NLT 31JUL96 FOR MODIFICATIONS AS PER MIO EUROPE LTR DATED 31JAN96: RELOCATION OF RIG AIR TANKS, INSTALLATION OF FIFTH GENERATOR, NEW WATER MAKER INSTALLATION, AND INSTALLATION OF LIFEBOAT NUMBER 3.
Condition: Unknown
Due 1 June 1996
Resolved 1 June 1996
Construction/Loadline
Issued 9 January 1996
Resolved
PROVIDE COPY OF ABS SURVEY REPORT DOCUMENTING REPAIRS TO BOW, PORT AND STBDSPUD CANS AND ASSOCIATED STRUCTURES.
Condition: Unknown
Due 4 April 1996
Resolved 4 April 1996
Construction/Loadline
Issued 9 January 1996
Resolved
PROVIDE ACCESS TO USCG UNDERNEATH RIG STRUCTURE FOR EXTERNAL HULL EXAMINATION; ALTERNATIVELY ABS SURVEYOR'S REPORT NOTING SAT. CONDITION WILLSUFFICE.
Condition: Unknown
Due 3 April 1996
Resolved 12 March 1996
Construction/Loadline
Issued 9 January 1996
Resolved
PROVIDE SAT. DOCUMENTATION OF NDE OF FOLLOWING AREAS; GUSSETS IN WAY OF LEGTO PORT CAN, CHORD "K" AND "L". PROVIDE COPY OF NDT REPORT BY ABS CERTIFIED TECHNICIAN.
Condition: Unknown
Due 9 January 1996
Resolved 9 January 1996
Unknown
Issued 6 April 1995
Resolved
MAKE ALL DRY BULK TANKS GAS FREE AND AVAILABLE FOR INSPECTION AT NEXT DRY DOCK.
Condition: Unknown
Due 6 April 1995
Resolved 6 April 1995
Lifesaving
Issued 6 April 1995
Resolved
PROVIDE ALL REQUIRED EQUIPMENT FOR NUMBER 3 LIFE BOAT.
Condition: Unknown
Due 6 April 1995
Resolved 6 April 1995
Electrical
Issued 11 April 1992
Resolved
PROVIDE UL/FM APPROVED CLASS I DIVISION 2 ELECTRICAL FIXTURE FOR THE GENERAL ALARM WARNING LIGHT MUD PITS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 6 August 1992
Resolved 6 August 1992
Electrical
Issued 11 April 1992
Resolved
PROVIDE LIGHTS FROM AN EMERGENCY POWER SOURCE TO ILLUMINATE THE LIFERAFT LAUNCHING AREAS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 6 August 1992
Resolved 6 August 1992
Accommodation/Occupational Safety
Issued 11 April 1992
Resolved
SEND STATEMENT TO OCMINY FROM THE OIM THAT THE 2 BULK TANKS IN THE CEMENT ROOM AND THEIR RELIEF VALVES ARE OPERATING PROPERLY.
Condition: Unknown
Due 11 April 1992
Resolved 11 April 1992
Lifesaving
Issued 11 April 1992
Resolved
CONDUCT WEIGHT TESTS OF LIFERAFT FALLS IN PRESENCE AND TO THE SATISFACTION OF THE ATTENDING USCG MARINE INSPECTOR._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 April 1992
Resolved 11 April 1992
Fire Fighting
Issued 14 April 1991
Resolved
REMOVE EXISTING 50LB CO2 FIRE EXTINGUISHER FROM PAINT LOCKER AND REPLACE D.O.T. APPROVED BOTTLE. UPON PROPER INSTALLATION OF 50LB F/E, YOU ARE DIRECTED TO FAC CG [name withheld] [phone withheld] WITH CORRECTIVE ACTION TAKE.
Condition: Unknown
Due 14 April 1991
Resolved 14 April 1991
Fire Fighting
Issued 20 March 1990
Resolved
PROVIDE [name withheld] WITH APPROVED PLANS FOR INTENDED SECONDARY LEG WATER TOWER INSTALLATION.
Condition: Unknown
Due 20 March 1990
Resolved 20 March 1990
Fire Fighting
Issued 27 May 1989
Resolved
PROVIDE ONE HALON BOTTLE FOR THE FIXED HALON SYSTEM FOR THE ENGINE ROOM.
Condition: Unknown
Due 27 May 1989
Resolved 27 May 1989
Fire Fighting
Issued 27 May 1989
Resolved
CONDUCT 5 YR HYDRO TEST ON ALL PORTABLE FIRE EXTINGUSHERS.
Condition: Unknown
Due 27 May 1989
Resolved 27 May 1989
Fire Fighting
Issued 9 June 1987
Resolved
PROVIDE CLOSURES FOR VENTILATION OPENINGS IN EMERGENCY GENERATOR HOUSE.
Condition: Unknown
Due 9 June 1987
Resolved 9 June 1987
Lifesaving
Issued 27 May 1987
Resolved
CALIB AND PROVE PROPER OPERATION OF H2S AND METHANE DETECTION SYTEMS.
Condition: Unknown
Due 27 May 1987
Resolved 27 May 1987
Fire Fighting
Issued 27 May 1987
Resolved
INSTALL HOSE REELS AT HELO DECK ACCESS AS REQUIRED BY 46 CFR 108.487(D).
Condition: Unknown
Due 27 May 1987
Resolved 27 May 1987
Lifesaving
Issued 27 May 1987
Resolved
PROVIDE OIL LANTERNS AND FULL FOR BOTH CAPSULES.
Condition: Unknown
Due 27 May 1987
Resolved 27 May 1987
Lifesaving
Issued 27 May 1987
Resolved
REPLACE EXPIRES PROJECTILES AND PRIMERS FOR LINE THROWING GUN.
Condition: Unknown
Due 27 May 1987
Resolved 27 May 1987
Lifesaving
Issued 27 May 1987
Resolved
REPAIR BROKEN SPRINKLER HEAR ON STBD CAPSULES WATER SPRAY SYSTEM.
Condition: Unknown
Due 27 May 1987
Resolved 27 May 1987
Lifesaving
Issued 27 May 1987
Resolved
REPLACE PROVISIONS, WATER AND MILK IN BOTH CAPSULES THAT HAS EXPIRES AS PERCAPSULES MANUFACTURERS RECOMMENDATIONS.
Condition: Unknown
Due 27 May 1987
Resolved 27 May 1987
Lifesaving
Issued 27 May 1987
Resolved
PROVIDE 12 PARACHUTE FLARES FOR THE STARBOARD CAPSULE.
Condition: Unknown
Due 27 May 1987
Resolved 27 May 1987
Fire Fighting
Issued 27 May 1987
Resolved
SUBMIT REVISED PLANS FOR HELO DECK FOAM SYSTEM (THAT REFLECTS ACTUAL INSTALLATION) FOR APPROVAL TO THIS OFFICE.
Condition: Unknown
Due 27 May 1987
Resolved 27 May 1987
Lifesaving
Issued 27 May 1987
Resolved
PROVIDE COAST GUARD APPROVED SMOKE SIGNALS (2 EACH) FOR LIFE CAPSULES.
Condition: Unknown
Due 27 May 1987
Resolved 27 May 1987
Fire Fighting
Issued 27 May 1987
Resolved
INSTALL A CLASS 1 DIVISION 1 UL APPROVED GENERAL ALARM OR LIGHT IN THE MUD PIT ROOM.
Condition: Unknown
Due 27 May 1987
Resolved 27 May 1987
Fire Fighting
Issued 27 May 1987
Resolved
PROVIDE CALIBRATION GAS AND PROVE PROPER OPERATION OF EXPLOSIVE METER.
Condition: Unknown
Due 27 May 1987
Resolved 27 May 1987
Deck/Cargo
Issued 6 June 1985
Resolved
PROVE OPERATION OF RELIEF VALVES ON ALL AIR RECEIVERS, SURGE TANK, AND BARITE TANK "D".
Condition: Unknown
Due 6 June 1985
Resolved 6 June 1985
Unknown
Issued 6 June 1985
Resolved
PROVE OPERATION OF EMERGENCY SHUTDOWN SWITCHES FOR MOTOR ROOM VENTILATION, QUARTERS VENTILATION, FUEL OIL TRANSFER PUMPS AND MAIN GENERATOR.
Condition: Unknown
Due 6 June 1985
Resolved 6 June 1985
Lifesaving
Issued 6 June 1985
Resolved
PROVIDE FULL COMPLEMENT OF 12 PARACHUTE FLARES FOR EACH SURVIVAL CAPSULE.
Condition: Unknown
Due 6 June 1985
Resolved 6 June 1985
Fire Fighting
Issued 6 June 1985
Resolved
PROVE THAT ALL 2 1/2 GALLON FOAM FIRE EXTINGUISHERS ARE APPROVED FOR MARINEUSE OR REMOVE FROM SERVICE.
Condition: Unknown
Due 6 June 1985
Resolved 6 June 1985
Unknown
Issued 6 June 1985
Resolved
PROVE OPERATION OF LOSS OF VENTILATION ALARM AND OPEN DOOR ALARM FOR MUD PIT ROOM.
Condition: Unknown
Due 6 June 1985
Resolved 6 June 1985
Lifesaving
Issued 6 June 1985
Resolved
PROVIDE FOOLDLIGHT ILLUMINATION ON EMERGENCY CIRCUITS FOR ALL LIFERAFTS ANDSURVIVAL CAPSULES AT BOTH STOWAGE POSITIONS AND EMBARKATION POSITIONS IN WATER.
Condition: Unknown
Due 6 June 1985
Resolved 6 June 1985