OCEAN EPOCH

OCEAN EPOCH is a 1977 mobile offshore drilling unit. The Coast Guard has recorded 30 inspections since 1984, most recently in May 1995, along with 157 deficiencies.

Records from 1984 to 1995. Most recent: inspection, 5 May 1995.

Built
1977
Last inspected
5 May 1995
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WCE8423
228693
Flag
PANAMA
—
Maury page id
psix-228693

Inspections, by type

…with no type recorded4
Years with a record 12 calendar years (1984–1995)
The 30 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 31 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it5829 - Regulatory (Subpart C or D), Gross Ton
3643 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WCE8423MMSI not assigned · expired · voluntarily equipped · granted 29 March 1994, cancelled 30 May 2004
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 30

5 May 1995 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1034671
17 August 1994 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 868222
14 June 1994 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1324935
28 February 1994 MARPOL Annex V Examination · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1166733
29 April 1993 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 827664
20 March 1992 Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1258698
3 March 1992 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 959439
29 October 1991 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1251928
9 September 1991 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1308399
7 August 1991 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1253808
7 March 1991 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1250882
29 June 1990 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 923561
13 April 1990 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 907604
13 April 1990 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1226212
7 March 1990 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1209392
20 November 1989 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 906128
1 September 1989 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1307199
14 June 1989 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1345846
28 October 1988 Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1040216
6 October 1988 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1197786
18 July 1988 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1034398
7 July 1988 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1209650
16 May 1988 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1196514
12 January 1988 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1323965
16 June 1987 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1313072
21 May 1987 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1028190
16 May 1986 Credit Drydock · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 988076
23 January 1986 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1295712
30 November 1985 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1297704
29 September 1984 Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1285505

Deficiency record · 157

Lifesaving
Issued 28 February 1994 Resolved
PROVIDE RETRO REFLECTIVE TAPE FOR LIFEBOAT NO. 2 AND ALL RING BUOYS.
Condition: Unknown
Due 28 February 1994
Resolved 28 February 1994
Deck/Cargo
Issued 28 February 1994 Resolved
PROVIDE REPAIR PROPOSAL FOR BULK TANK NO 6 FOR USCG APPROVAL (INCLUDING ASME APPROVED REPAIR FACILITY, WELDING PROCEDURE, MATERIAL SPECS, WELDER QUALIFICATIONS, AND NDT TEST PROCEDURE). USCG APPROVAL/INSPECTION REQUIREDPRIOR TO PLACING BULK TANK NO 6 BACK IN SERVICE.
Condition: Unknown
Due 28 February 1994
Resolved 28 February 1994
Documentation
Issued 28 February 1994 Resolved
CONDUCT ANNUAL ABS CRANE INSPECTION AND LOADLINE SURVEY (DUE NLT 30 APR 94)AND FAX [name withheld] OF ANNUAL ABS CRANE INSPECTION REPORT AND ENDORSED ABS LOADLINE CERTIFICATE.
Condition: Unknown
Due 27 May 1994
Resolved 27 May 1994
Lifesaving
Issued 28 February 1994 Resolved
PROVIDE "SMOKE" FOR QUICK RELEASE RING BUOY LOCATED NEAR LIFEBOAT STATION NO. 1.
Condition: Unknown
Due 28 February 1994
Resolved 28 February 1994
Lifesaving
Issued 28 February 1994 Resolved
RENEW WASTED VENT DUCTING IN CEMENT ROOM.
Condition: Unknown
Due 28 February 1994
Resolved 28 February 1994
Lifesaving
Issued 28 February 1994 Resolved
RENEW ELECTRICAL CONTROLLER BOX FOR LIFEBOAT NO. 1 WINCH.
Condition: Unknown
Due 28 February 1994
Resolved 28 February 1994
Fire Fighting
Issued 28 February 1994 Resolved
PROVIDE A ROTATING BEACON IN ADDITION TO ALARM SIREN FOR CO2 DISCHARGE WARNING IN ENGINE ROOM. (BEACON MUST BE CONNECTED TO EMERGENCY POWER SOURCE.)
Condition: Unknown
Due 28 February 1994
Resolved 28 February 1994
Electrical
Issued 28 February 1994 Resolved
PROVE PROPER OPERATION OF THE SHUTDOWN FOR THE GENERATOR PRIME MOVERS (NO. 1, 2 & 3) INCONJUNCTION WITH TESTING OF EMERGENCY RIG SHUTDOWN.
Condition: Unknown
Due 28 February 1994
Resolved 28 February 1994
Engineering
Issued 28 February 1994 Resolved
DEMONSTRATE REMOTE SHUTDOWN OF FUEL CENTRIFUGE.
Condition: Unknown
Due 28 February 1994
Resolved 28 February 1994
Lifesaving
Issued 28 February 1994 Resolved
DEMONSTRATE OPERATION OF "TEXAS ANALYTICAL CONTROL" COMBUSTIBLE GAS DETECTION SYSTEM.
Condition: Unknown
Due 28 February 1994
Resolved 28 February 1994
Lifesaving
Issued 28 February 1994 Resolved
PROVIDE ADDITIONAL ROTATING BEACON FOR GENERAL ALARM SYSTEM IN ENGINE ROOM.(RECOMMEND BEACON BE LOCATED IN CENTER OF ENGINE ROOM.)
Condition: Unknown
Due 28 February 1994
Resolved 28 February 1994
Fire Fighting
Issued 28 February 1994 Resolved
REPLACE OR HYDRO TEST/SERVICE PORTABLE FIRE EXTINGUISHERS IN ACCORDANCE WITH WORMALD FIRE SYSTEMS INSPECTION REPORT OF 28FEB94. (ALL HYDRO TESTINGOF CYLINDERS MUST BE DONE AT A D.O.T. APPROVED FACILITY.)
Condition: Unknown
Due 28 February 1994
Resolved 28 February 1994
Fire Fighting
Issued 28 February 1994 Resolved
REPLACE OR HYDRO TEST THE FIVE (5) NITROGEN CYLINDERS FOR THE HELIPORT FIREBOSS B-V SEMI PORTABLE FIRE EXTINGUISHER. (HYDRO TESTING OF CYLINDERS MUSTBE DONE AT A D.O.T. APPROVED FACILITY.)
Condition: Unknown
Due 28 February 1994
Resolved 28 February 1994
Electrical
Issued 28 February 1994 Resolved
PROPERLY SECURE ELECTRICAL WIRES FOR WELDING LEAD AND DEHUMIDIFIER LOCATED IN STBD LOWER PUMP ROOM.
Condition: Unknown
Due 28 February 1994
Resolved 28 February 1994
Electrical
Issued 28 February 1994 Resolved
RENEW NO.1 SHIP SERVICE GENERATOR SALT WATER COOLING LINE.
Condition: Unknown
Due 28 February 1994
Resolved 28 February 1994
Lifesaving
Issued 28 February 1994 Resolved
DEMONSTRATE OPERATION OF THE WATER SPRAY SYSTEM FOR LIFEBOAT NO. 1.
Condition: Unknown
Due 28 February 1994
Resolved 28 February 1994
Engineering
Issued 28 February 1994 Resolved
RENEW FLAME SCREENS FOR ALL FUEL OIL TANK VENTS.
Condition: Unknown
Due 28 February 1994
Resolved 28 February 1994
Lifesaving
Issued 28 February 1994 Resolved
RELOCATE RING BUOY LOCATED OUTSIDE GENERATOR ROOM (HEAT DAMAGE).
Condition: Unknown
Due 28 February 1994
Resolved 28 February 1994
Lifesaving
Issued 28 February 1994 Resolved
DEMONSTRATE OPERATION OF GENERAL ALARM BELLS AT STBD BOW (1) AND ENGINE ROOM (2). RENEW RED GLOBE FOR AFT ENGINE ROOM GENERAL ALARM ROTATING BEACON.
Condition: Unknown
Due 28 February 1994
Resolved 28 February 1994
Fire Fighting
Issued 29 April 1993 Resolved
RENEW THE FOUNDATION STAND FOR THE FIXED CO2 BOTTLES LOCATED IN THE CO2 CONTROL ROOM IAW 46 CFR 95.15-20.
Condition: Unknown
Due 29 April 1993
Resolved 29 April 1993
Electrical
Issued 3 March 1992 Resolved
PROVE SATISFACTORY OPERATION OF TRIPS AND ALARMS FOR EMERGENCY DIESEL GENERATOR.
Condition: Unknown
Due 3 March 1992
Resolved 3 March 1992
Lifesaving
Issued 3 March 1992 Resolved
RENEW ALL PROVISIONS AND CONDENSED MILK IN LIFEBOAT #1 AND #2.
Condition: Unknown
Due 3 March 1992
Resolved 3 March 1992
Accommodation/Occupational Safety
Issued 7 August 1991 Resolved
PROVIDE [name withheld] PLANS AND MANUFACTURERS' DATA REPORT FOR NEWLY INSTALLED BULK AIR DRYING TANK, AS PER 46CFR PARTS 54.01-5(d) & (e) AND 54.10-3(c).
Condition: Unknown
Due 7 August 1991
Resolved 7 August 1991
Electrical
Issued 7 August 1991 Resolved
PROVE PROPER OPERATION OF LOW LUBE OIL SHUTDOWN ALARM ON #3 E.M.D.
Condition: Unknown
Due 30 September 1991
Resolved 30 September 1991
Lifesaving
Issued 7 March 1991 Resolved
PROVIDE 70 QUARTS DRINKING WATER FOR LIFEBOAT #1; 10 QUARTS DRINKING WATER FOR LIFEBOAT #2.
Condition: Unknown
Due 7 March 1991
Resolved 7 March 1991
Electrical
Issued 7 March 1991 Resolved
MAKE OPERABLE FOLLOWING EMERGENCY SHUTDOWN SWITCHES; SCR ROOM VENT SHUTDOWN, PORT PUMP ROOM VENT SHUTDOWN, ENGINE ROOM VENT SHUTDOWN, EMERG GENERATOR ROOM VENT SHUT DOWN, FUEL OIL SERVICE PUMPS #1&#2 SHUTDOWNS, CEMENT ROOM VENT SHUTDOWN, RIG MASTER VENT SHUTDOWN FROM DRILL FLOOR.
Condition: Unknown
Due 7 March 1991
Resolved 7 March 1991
Electrical
Issued 7 March 1991 Resolved
REPAIR/REPLACE ALL INOPERATIVE BATTERY POWERED EMERGENCY LIGHTS THROUGHTOUTRIG (12 LOCATIONS CITED).
Condition: Unknown
Due 7 March 1991
Resolved 7 March 1991
Fire Fighting
Issued 7 March 1991 Resolved
CONDUCT TEST OF ALL FIRE ALARM PULL BOXES THROUGHOUT RIG. REPAIR/REPLACE THOSE FOUND INOPERABLE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 March 1991
Resolved 7 March 1991
Lifesaving
Issued 7 March 1991 Resolved
CLEAN OR REPLACE FOGGED UP COXWAIN VIEWPOINTS ON #1 AND #2 MOTOR LIFEBOAT TO PERMIT UNIMPAIRED VISIBILITY.
Condition: Unknown
Due 7 March 1991
Resolved 7 March 1991
Fire Fighting
Issued 7 March 1991 Resolved
REMOVE AND PLUG ALL EXTRANEOUS TAPS AND OFFSTICKER PIPING FROM FIREMAIN.
Condition: Unknown
Due 7 March 1991
Resolved 7 March 1991
Accommodation/Occupational Safety
Issued 7 March 1991 Resolved
REPLACE MISSING ACCESS LADDERS FOR PORT SIDE AUXILIARY MACHINERY SPACE VENTCLOSURES.
Condition: Unknown
Due 7 March 1991
Resolved 7 March 1991
Accommodation/Occupational Safety
Issued 7 March 1991 Resolved
RENEW DETERONATED SELF CLOSING GAS TIGHT DOOR AND FRAME ASSEMBLY AT MUD PUMP ROOM ACCESS TO MUD PITS.
Condition: Unknown
Due 7 March 1991
Resolved 7 March 1991
Navigation
Issued 7 March 1991 Resolved
PROVIDE PRESSURE GAUGE AND RELIEF VALVE SET AT OR BELOW MAWP FOR NEWLY INSTALLED AIR DRYING TANK.
Condition: Unknown
Due 7 March 1991
Resolved 7 March 1991
Lifesaving
Issued 7 March 1991 Resolved
OBTAIN CALIBRATION GAS AND CONDUCT TEST OF ALL COMBUSTIBLE GAS SENSORS.
Condition: Unknown
Due 7 March 1991
Resolved 7 March 1991
Electrical
Issued 7 March 1991 Resolved
REPLACE MISSING GENERAL ALARM LIGHT IN CEMENT ROOM.
Condition: Unknown
Due 7 March 1991
Resolved 7 March 1991
Lifesaving
Issued 7 March 1991 Resolved
VESSEL TOTAL PERSONS ON BOARD CAPACITY TO BE REDUCED TO 76 BY 15MAR91 UNLESS ADDITIONAL IN DATE LIFERAFTS ARE PROVIDED. TOTAL PERSONS ON BOARD CAPACITY TO BE REDUCED TO 64 ON 31MAR91 UNLESS MINIMUM 48 PERSON CAPACITY IN DAVIT LAUNCHED RAFTS IS PROVIDED.
Condition: Unknown
Due 7 March 1991
Resolved 7 March 1991
Electrical
Issued 7 March 1991 Resolved
MAKE OPERABLE #2 GENERATOR REVERSE POWER RELAY.
Condition: Unknown
Due 7 March 1991
Resolved 7 March 1991
Electrical
Issued 7 March 1991 Resolved
TEST OVERSPEED TRIP, LOW OIL PRESSURE TEMP, AND REVERSE POWER RELAY UPON COMPLETION OF #3 GENERATOR PRIME MOVER OVERHAUL.
Condition: Unknown
Due 7 March 1991
Resolved 7 March 1991
Electrical
Issued 7 March 1991 Resolved
REPAIR OR REPLACE TWO DAMAGED HAZARDOUS LOCATION TYPE LIGHTS OVER MUD PITS.
Condition: Unknown
Due 7 March 1991
Resolved 7 March 1991
Deck/Cargo
Issued 7 March 1991 Resolved
REPLACE DETRIONATED FUEL REFILLING HOSE FOR STBD PEDESTAL CRANES.
Condition: Unknown
Due 7 March 1991
Resolved 7 March 1991
Deck/Cargo
Issued 7 March 1991 Resolved
REPLACE DETENORATED FUEL LINES ON COLD SHIP STARTING AIR COMPRESSION PRIME MOVER.
Condition: Unknown
Due 7 March 1991
Resolved 7 March 1991
Fire Fighting
Issued 7 March 1991 Resolved
PROVIDE FLASHLIGHTS FOR FIREMAN OUTFITS.
Condition: Unknown
Due 7 March 1991
Resolved 7 March 1991
Electrical
Issued 7 March 1991 Resolved
PROVIDE OPERABLE REMOTE SHUTDOWN SWITCHES FOR NEWLY INSTALLED MACHINERY SPACE, MUD PUMP ROOM, AND TRANSFORMER ROOM VENTILATION FANS.
Condition: Unknown
Due 7 March 1991
Resolved 7 March 1991
Fire Fighting
Issued 7 March 1991 Resolved
TEST TO CONFIRM OPERATION OF FIXED ASSOCIATED VESTICATION (MACHINERY SHUTDOWN).
Condition: Unknown
Due 7 March 1991
Resolved 7 March 1991
Fire Fighting
Issued 7 March 1991 Resolved
INSTALL MACHINERY SPACE FIRE DETECTION SYSTEM PER IMO MODU CODE 8.2.2., STEEL WINDOW COVERS FOR DRILL FLOOR SIDES IMO 9.2.13., ACCOMMODATIONS & SERVICE SPACE FIRE DETECTION SYSTEM IMO 9.7., AND PORTABLE RADIO IMO 10.7, OR SURENDER IMO MODU CODE CERTIFICATE ISSUED 7MAR90.
Condition: Unknown
Due 7 March 1991
Resolved 7 March 1991
Fire Fighting
Issued 7 March 1991 Resolved
REPLACE MISSING HELICOPTER DECK FOAM HOSE.
Condition: Unknown
Due 7 March 1991
Resolved 7 March 1991
Unknown
Issued 14 June 1989 Resolved
PROVIDE SAFETY BELTS AND RIDING BELTS THAT COMPLY WITH ANSI 10.14 33CFR 142.27.
Condition: Unknown
Due 14 June 1989
Resolved 14 June 1989
Fire Fighting
Issued 14 June 1989 Resolved
REPAIR DRY CHEMICAL SYSTEM ON HELO DECK.
Condition: Unknown
Due 14 June 1989
Resolved 14 June 1989
Fire Fighting
Issued 14 June 1989 Resolved
PROVIDE FOAM ANALYSIS REPORT REQUIRED BY 46 CFR.
Condition: Unknown
Due 14 June 1989
Resolved 14 June 1989
Fire Fighting
Issued 14 June 1989 Resolved
EVALUATE THE FIRE PUMP SYSTEMS, PUMPS FOR WEAR. PITO PRESSURE VARIES FROM 12 PSI ONE PUMP TO 10 PSI-30 PSI PITO WITH TO HOSES RUNNING AND TWO PUMPS RUNNING. VOLUME IS SUFFICIENT FOR FIRE FIGHTING.
Condition: Unknown
Due 14 June 1989
Resolved 14 June 1989
Electrical
Issued 14 June 1989 Resolved
POUR ALL EYS FITTINGS ON SWACO GEOLOGRAPH UNDER DRILL FLOOR, SWACO CENTRI- FUGE ON FWD MUD PIT/SHALE SHAKER AREA AND THE JUNCTION BOX SERVING THE SWACO CENTRIFUGE.
Condition: Unknown
Due 14 June 1989
Resolved 14 June 1989
Unknown
Issued 14 June 1989 Resolved
REPAIR THE MOON POOL DECK LIGHT UNDER THE PORT SIDE OF THE DRILL FLOOR. MAKE PROPER APPROVED WIRE SPLICES(IE. NO WIRE NUTS)
Condition: Unknown
Due 14 June 1989
Resolved 14 June 1989
Electrical
Issued 14 June 1989 Resolved
POUR EYS FITTINGS ON THE MUD PIT LEVEL INDICATORS IN THE MUD PIT AREA AND BELOW THE AFT V DOOR.
Condition: Unknown
Due 14 June 1989
Resolved 14 June 1989
Electrical
Issued 14 June 1989 Resolved
INSTALL A PURGE FAILURE ALARM ON THE GSL MUD MONITOR ON TOP OF THE DRILLERSCONSOLE AND REPAIR THE ELECTRICAL CABLE CONNECTION. (NFPA 496).
Condition: Unknown
Due 14 June 1989
Resolved 14 June 1989
Electrical
Issued 14 June 1989 Resolved
INSTALL A PURGE FAILURE ALARM AND A CLEAN AIR SUPPLY IN THE DRILLERS LOGGING UNIT CONSOLE IAW 476.
Condition: Unknown
Due 14 June 1989
Resolved 14 June 1989
Unknown
Issued 14 June 1989 Resolved
INSTALL A PURGE FAILURE ALARM ON THE DRILLERS PIT FLOW METER (NFPA 476)
Condition: Unknown
Due 14 June 1989
Resolved 14 June 1989
Unknown
Issued 14 June 1989 Resolved
PURGE AND OVERPRESSURE THE DRILLERS CONSOLE AND INSTALL A PURGE FAILURE ALARM (NFPA 496)
Condition: Unknown
Due 14 June 1989
Resolved 14 June 1989
Unknown
Issued 14 June 1989 Resolved
POST CO2 FLOODING CONTROL LABELS FOR THE REMOTE STATION IN THE MUD/PIT SHALE SHAKER AREA SERVICING THE SCR CONTROL ROOM.
Condition: Unknown
Due 14 June 1989
Resolved 14 June 1989
Electrical
Issued 14 June 1989 Resolved
PURGE AND OVERPRESSURE THE TELEOD TOOL FACE METER ON TOP OF THE DRILLERS CONSOLE AND INSTALL A PURGE FAILURE ALARM. (NFPA)
Condition: Unknown
Due 14 June 1989
Resolved 14 June 1989
Unknown
Issued 14 June 1989 Resolved
REPAIR THE TELEPHONE WIRING ON THE PHONE ON THE STARBOARD PIPE DECK.
Condition: Unknown
Due 14 June 1989
Resolved 14 June 1989
Electrical
Issued 14 June 1989 Resolved
REPAIR THE TEMPORARAY EMERGENCY LIGHTS FOR THE STARBOARD PUMPROOM AND STARBOARD LIFT LEVEL STOREROOM.
Condition: Unknown
Due 14 June 1989
Resolved 14 June 1989
Unknown
Issued 14 June 1989 Resolved
INSTALL GENERAL CARTRIDGES IN ALL GENERAL DRY CHEMICAL EXTINGUISHERS AND RECHARGE FIRE EXTINGUISHER #48 ON YHE DRILL FLOOR.
Condition: Unknown
Due 14 June 1989
Resolved 14 June 1989
Unknown
Issued 14 June 1989 Resolved
REMOVE ALL DOOR HOLDBACKS ON THE SELF CLOSING, GAS TIGHT DOORS FROM THE MUDPIT/ SHALE SHAKER AREA SERVICING THE SCR CONTROL ROOM.
Condition: Unknown
Due 14 June 1989
Resolved 14 June 1989
Electrical
Issued 14 June 1989 Resolved
CORRECT GENERAL ALARM BELLS AS NECESSARY.
Condition: Unknown
Due 14 June 1989
Resolved 14 June 1989
Fire Fighting
Issued 14 June 1989 Resolved
REPAIR EMERGENCY FIRE PUMP BEARING.
Condition: Unknown
Due 14 June 1989
Resolved 14 June 1989
Fire Fighting
Issued 14 June 1989 Resolved
REPAIR THE LEAKING FLANGE (REPLACE) ON THE SALT WATER PUMP IN THE SNAKE PIT.
Condition: Unknown
Due 14 June 1989
Resolved 14 June 1989
Fire Fighting
Issued 14 June 1989 Resolved
REMOVE THE DOUBLERS FROM THE FIREMAIN SYSTEM IN THE SNAKE PIT.
Condition: Unknown
Due 14 June 1989
Resolved 14 June 1989
Unknown
Issued 14 June 1989 Resolved
REPAIR THE #2 MAIN DIESEL GENERATOR.
Condition: Unknown
Due 14 June 1989
Resolved 14 June 1989
Accommodation/Occupational Safety
Issued 14 June 1989 Resolved
REPAIR THE AIR VENT LOUVERS ON THE AIR VENT ON THE PORT SIDE BEHIND THE #1 AND #4 TANKS.
Condition: Unknown
Due 14 June 1989
Resolved 14 June 1989
Electrical
Issued 14 June 1989 Resolved
REPAIR ALL OF THE MAIN DECK ELECTRICAL KICK PIPES.
Condition: Unknown
Due 14 June 1989
Resolved 14 June 1989
Engineering
Issued 14 June 1989 Resolved
REPAIR THE LOW LUBE OIL SHUTDOWN ON THE EMERGENCY DIESEL GENERATOR.
Condition: Unknown
Due 14 June 1989
Resolved 14 June 1989
Unknown
Issued 14 June 1989 Resolved
RAISE ARTIFICIAL ISLAND LTS SO BOTTOM IS AT TOP OF HANDRAIL CHANGE CHARACT-ERISTICS TO QUICK FLASH IAW 33CFR PART 67.
Condition: Unknown
Due 14 June 1989
Resolved 14 June 1989
Unknown
Issued 14 June 1989 Resolved
LOG ITEMS AND CONDUCT TESTS REQUIRED BY 46CFR 109.211
Condition: Unknown
Due 14 June 1989
Resolved 14 June 1989
Fire Fighting
Issued 18 July 1988 Resolved
PROVIDE STANDARD FIRE FIGHTING GEAR ON BOARD (2 SETS) ARE REQUIRED BY 46CFR108.497. THIS IS A FOLLOW UP OF ITEM 11 ISSUED 16MAY88. WRONG SUIT SENT TO VESSEL.
Condition: Unknown
Due 18 July 1988
Resolved 18 July 1988
Fire Fighting
Issued 18 July 1988 Resolved
PROVIDE EVIDENCE THAT THE 100# CO2 BOTTLES AND FLEXIBLE LOOPS IN TYHE OIL/PAINT LOCKER HAVE BEEN SERVICED 46CFR107.235. LETTER PROVIDED TODAY DOES NOT SATISFY ITEM 22 ISSUED 16 MAY 88.
Condition: Unknown
Due 18 July 1988
Resolved 18 July 1988
Unknown
Issued 18 July 1988 Resolved
POST OPERATING INSTRUCTIONS FOR THE FIXED CO2 SYSTEM ON BOTH EXTERIOR PAINTLOCKERS. SEE 46 CFR 108.631 "IA"
Condition: Unknown
Due 18 July 1988
Resolved 18 July 1988
Electrical
Issued 18 July 1988 Resolved
REPAIR LOOSE JUCTION BOX TO "EYS" CONDUIT ON DRILL FLOOR IN AREA OF MAIN WINCH. 46CFR111.105
Condition: Unknown
Due 18 July 1988
Resolved 18 July 1988
Fire Fighting
Issued 18 July 1988 Resolved
COMPLETE HYDROSTATIC TESTING OF THE S.C.B.A. BOTTLES IN STOWAGE AREA #3 (2 BOTTLES) AS PER 46 CFR 108.497- (ITEM 12 OF 16 MAY 88)
Condition: Unknown
Due 18 July 1988
Resolved 18 July 1988
Unknown
Issued 18 July 1988 Resolved
HELO DECK PERIMETER LIGHTS (ITEM 14 OF 16 MAY 88) REMAIN OUTSTANDING. ORDERED 18MAY88 NOT RECEIVED TO DATE.
Condition: Unknown
Due 18 July 1988
Resolved 18 July 1988
Documentation
Issued 16 May 1988 Resolved
PROVIDE ON BOARD A COMPLETE APPROVED OPERATIONS MANUAL. PRESENT COPY IS MISSING PERTINENTS INFORMATION. (46 CFR 109.121)
Condition: Unknown
Due 16 May 1988
Resolved 16 May 1988
Documentation
Issued 16 May 1988 Resolved
INSTITUTE AND MAINTAIN A LOG ON BOARD WHICH ADDRESSES ALL TEST DRILL AND INSPECTIONS REQUIRED BY 46 CFR 109.201 THRU 109.433.
Condition: Unknown
Due 16 May 1988
Resolved 16 May 1988
Fire Fighting
Issued 16 May 1988 Resolved
PROVIDE A CLOSURE DEVECE FOR THE VENT ON THE PORTABLE PAINT LOCKER. (46 CFR 108.455)
Condition: Unknown
Due 16 May 1988
Resolved 16 May 1988
Electrical
Issued 16 May 1988 Resolved
PROVIDE GUARDS FOR PERIMETER LIGHTS ON HELIDECK. (46 CFR 111.75-20)
Condition: Unknown
Due 16 May 1988
Resolved 16 May 1988
Electrical
Issued 16 May 1988 Resolved
REPAIR HANGERS FOR OVERHEAD WIRES IN BALLAST CONTROL ROOM. (46 CFR 111.60)
Condition: Unknown
Due 16 May 1988
Resolved 16 May 1988
Lifesaving
Issued 16 May 1988 Resolved
APPROPRIATELY SUPPORT WIRING TO LIMIT SWITCHES AT #1 LIFEBOAT. (46 CFR 111.60)
Condition: Unknown
Due 16 May 1988
Resolved 16 May 1988
Fire Fighting
Issued 16 May 1988 Resolved
PROVIDE EVIDENCE THAT FIXED FOAM SYSTEM INSTALLED ON HELIDECK HAS BEEN APPROVED BY COMMANDANT,USCG,(G-MTH). IF NOT SUBMIT SAME IN ACCORDANCE WITH46 CFR 56.01-10)
Condition: Unknown
Due 16 May 1988
Resolved 16 May 1988
Lifesaving
Issued 16 May 1988 Resolved
PROVIDE EVIDENCE OF DATE LIFEBOAT FALLS WERE INSTALLED ON BOTH BOATS. AS PER MANUFACTURERS INSTRUCTIONS.
Condition: Unknown
Due 16 May 1988
Resolved 16 May 1988
Navigation
Issued 16 May 1988 Resolved
PROVIDE ON BOARD ONE (01) APPROVED FOGHORN THAT COMPLIES WITH 33 CFR 67 TIMING OF SAME IS TO BE SET AS THAT FOR AN ARTIFICIAL ISLAND THAT IS 2 SECONDS BLAST, 18 SECOND PAUSE.
Condition: Unknown
Due 16 May 1988
Resolved 16 May 1988
Fire Fighting
Issued 16 May 1988 Resolved
PROVIDE TWO NEW 2 AND (1/2) HALF HOSES FOR THOSE WHICH FAILED DURING INSPECTION. (46 CFR 108.425)
Condition: Unknown
Due 16 May 1988
Resolved 16 May 1988
Fire Fighting
Issued 16 May 1988 Resolved
PROVIDE EVIDENCE THAT THE 100# CO2 BOTTLES AND FLEXIBLE LOOP IN THE OIL/ PAINT LOCKER HAS BEEN SERVICED. (46 CFR 107.235)
Condition: Unknown
Due 16 May 1988
Resolved 16 May 1988
Engineering
Issued 16 May 1988 Resolved
PROVIDE 4 EACH PRESSURE RELIEFS VALVES WITH HAND RELIEVING DEVICES, NOT TO EXCEED THE MAXIMUM ALOWABLE WORKING PRESSURE OF THE TANK IT PROTECTS. (46 CFR 61.10-5-VESSEL AIR RECEIVERS.)
Condition: Unknown
Due 16 May 1988
Resolved 16 May 1988
Engineering
Issued 16 May 1988 Resolved
MAKE AVAILABLE ALL T.O.K. TENSIONER BOTTLES FOR INTERNAL INSPECTION AND TEST OF THEIR RELIEF VALVES. (46 CFR 61.10-5)
Condition: Unknown
Due 16 May 1988
Resolved 16 May 1988
Electrical
Issued 16 May 1988 Resolved
PROVIDE A COVER FOR MOTOR CONTROL CENTER. (46 CFR 111.30)
Condition: Unknown
Due 16 May 1988
Resolved 16 May 1988
Electrical
Issued 16 May 1988 Resolved
PROVIDE ADDITIONAL GENERAL ALARMS AND/OR LIGHTS IN TGO THE FOLLOWING LOCATIONS: EMERGENCY GENERATOR ROOM, SCR ROOM. (46 CFR 113.25)
Condition: Unknown
Due 16 May 1988
Resolved 16 May 1988
Electrical
Issued 16 May 1988 Resolved
PROPERLY SUPPORT ALL WIRING INSTALLED FOR THE SERVICING EQUIPMENT. (46 CFR 111.105)
Condition: Unknown
Due 16 May 1988
Resolved 16 May 1988
Documentation
Issued 16 May 1988 Resolved
SUBMIT THREE COPIES OF THE VESSELS FIRE AND SAFETY PLANS TGO SHOWING THE NEW HELO DECK FIRE FIGHTING EQUIPMENT AND HELO FUELING SYSTEM FOR APPROVAL BY COAST GUARD MARINE INSPECTION OFFICE. ALSO INCLUDE ANY OTHER NEW EQUIPMENT INSTALLED.
Condition: Unknown
Due 16 May 1988
Resolved 16 May 1988
Electrical
Issued 16 May 1988 Resolved
APPROPRIATELY FILL, WITH THE APPROPRIATE COMPOUND, THE EYS FITTINGS IN THE PORTABLE PAINT LOCKER AT THE LIGHT SWITCH. (46 CFR 111.105)
Condition: Unknown
Due 16 May 1988
Resolved 16 May 1988
Accommodation/Occupational Safety
Issued 16 May 1988 Resolved
PROVIDE APPROPRIATE HARDWARE FOR ALL WEATHER TIGHT/WATER TIGHT CLOSURES AND APPROPRIATE DOG FOR DOOR ON PAINT LOCKER. (46 CFR 108.181)
Condition: Unknown
Due 16 May 1988
Resolved 16 May 1988
Lifesaving
Issued 16 May 1988 Resolved
REMOVE OR SUBMIT FOR APPROVAL, ALL SECONDARY MEANS OF ABANDONMENT (I,E. MONKEY LINES, SCRAMBLE NETS AND JACOBS LADDERS.) (46 CFR 108.527)
Condition: Unknown
Due 16 May 1988
Resolved 16 May 1988
Fire Fighting
Issued 16 May 1988 Resolved
PROVIDE STANDARD FIREFIGHTING GEAR (TURNOUT GEAR) AND NON CONDUCTIVE GLOVESFOR FIREFIGHTING GEAR LOCKERS. (46 CFR 108.497)
Condition: Unknown
Due 16 May 1988
Resolved 16 May 1988
Fire Fighting
Issued 16 May 1988 Resolved
HAVE ALL SCBA BOTTLES HYDROTESTED. PRESENTLY EQUIPPED BOTTLES REQUIRE A 5 YEAR HYDRO. (46 CFR 108.497)
Condition: Unknown
Due 16 May 1988
Resolved 16 May 1988
Lifesaving
Issued 16 May 1988 Resolved
PROVIDE A B-I FIRE EXTINGUISHER FOR #2 LIFEBOAT. (46 CFR 108.503)
Condition: Unknown
Due 16 May 1988
Resolved 16 May 1988
Deck/Cargo
Issued 16 June 1987 Resolved
INSTALL A PRESSURE RELIEF VALVE ON THE REPLACEMENT PRESSURE VESSEL IN THE MOON POOL AREA.
Condition: Unknown
Due 16 June 1987
Resolved 16 June 1987
Electrical
Issued 16 June 1987 Resolved
REPLACE THE FAULTY RELAY FOR THE AUTO-START UPON MAIN POWER FAILURE, FEATURE OF THE EMERGENCY GENERATOR.
Condition: Unknown
Due 16 June 1987
Resolved 16 June 1987
Lifesaving
Issued 16 June 1987 Resolved
REPLACE TWO OUT OF DATE ORANGE SMOKE SIGNALS FOR N0. 1 LIFEBOAT.
Condition: Unknown
Due 16 June 1987
Resolved 16 June 1987
Unknown
Issued 16 May 1986 Resolved
MARK ALL EMERGENCY LIGHTS WITH THE LETTER "E".
Condition: Unknown
Due 16 May 1986
Resolved 16 May 1986
Unknown
Issued 16 May 1986 Resolved
REMOVE UNSUPPORTED ELECTRICAL CABLE FROM SC4 COLUMN.
Condition: Unknown
Due 16 May 1986
Resolved 16 May 1986
Unknown
Issued 16 May 1986 Resolved
REPAIR HANDLE TO CO2 CONTROL BOX IN THE ENGINE ROOM.
Condition: Unknown
Due 16 May 1986
Resolved 16 May 1986
Unknown
Issued 16 May 1986 Resolved
LABEL NUMBER 1 FUEL OIL SERVICE PUMP EMERGENCY SHUTOFF.
Condition: Unknown
Due 16 May 1986
Resolved 16 May 1986
Unknown
Issued 16 May 1986 Resolved
REPLACE TWELVE OUTDATED HAND HELD PARACHUTE FLARES FOR EACH LIFEBOAT.
Condition: Unknown
Due 16 May 1986
Resolved 16 May 1986
Unknown
Issued 16 May 1986 Resolved
PROVIDE 7 COAST GUARD APPROVED EXPOSURE SUITS. TOTAL PERSONS ALLOWED IS LIMITED TO 73 PERSONS UNTIL THIS ITEM IS COMPLETED.
Condition: Unknown
Due 16 May 1986
Resolved 16 May 1986
Unknown
Issued 16 May 1986 Resolved
SECURE ELECTRICAL WIRE IN WIREWAYS IN MUD PIT AREA.
Condition: Unknown
Due 16 May 1986
Resolved 16 May 1986
Unknown
Issued 16 May 1986 Resolved
REPLACE WIRING TO STORES WINCH IN PCI COLUMN.
Condition: Unknown
Due 16 May 1986
Resolved 16 May 1986
Unknown
Issued 16 May 1986 Resolved
REMOVE UNUSED ELECTRICAL WIRING FROM WIREWAY IN THE CEMENT ROOM.
Condition: Unknown
Due 16 May 1986
Resolved 16 May 1986
Unknown
Issued 16 May 1986 Resolved
REPAIR THE INOPERABLE COMBUSTABLE GAS INDICATOR.
Condition: Unknown
Due 16 May 1986
Resolved 16 May 1986
Unknown
Issued 16 May 1986 Resolved
PROVIDE CORRECT BRACKETS FOR PORTABLE CO2 EXTINGUISHERS AS NECESSARY.
Condition: Unknown
Due 16 May 1986
Resolved 16 May 1986
Unknown
Issued 16 May 1986 Resolved
PROVIDE ONE QUART OF ILLUMINATING OIL FOR EACH LIFEBOAT.
Condition: Unknown
Due 16 May 1986
Resolved 16 May 1986
Unknown
Issued 16 May 1986 Resolved
RECHARGE AIR SUPPLY BOTTLES FOR NUMBER 1 AND NUMBER 2 LIFEBOATS.
Condition: Unknown
Due 16 May 1986
Resolved 16 May 1986
Unknown
Issued 16 May 1986 Resolved
REPAIR OR REPLACE THE STEERING CABLE FOR THE NUMBER 1 LIFEBOAT.
Condition: Unknown
Due 16 May 1986
Resolved 16 May 1986
Unknown
Issued 30 November 1985 Resolved
PROVIDE AN AUDIBLE WARNING DEVICE FOR THE FORKLIFT IAW 46CFR108.613(D)(1).
Condition: Unknown
Due 30 November 1985
Resolved 30 November 1985
Unknown
Issued 30 November 1985 Resolved
PROVIDE 1 QUART OF ILLUMINATING OIL FOR EACH LIFEBOAT.
Condition: Unknown
Due 30 November 1985
Resolved 30 November 1985
Unknown
Issued 30 November 1985 Resolved
PROVIDE 100 POUNDS OF PROVISIONS FOR EACH LIFEBOAT.
Condition: Unknown
Due 30 November 1985
Resolved 30 November 1985
Unknown
Issued 30 November 1985 Resolved
PROVIDE 5 - 100 LB CO2 CYLINDERS THAT HAVE BEEN REMOVED FROM THE MAIN BANK OF THE CO2 FIRE EXTINGUISHING SYSTEM.
Condition: Unknown
Due 30 November 1985
Resolved 30 November 1985
Unknown
Issued 30 November 1985 Resolved
PROVIDE 2 OPERABLE BATTERY PACKS FOR THE O2/EXPLOSIVE METERS FOR THE FIREMEN OUTFITS.
Condition: Unknown
Due 30 November 1985
Resolved 30 November 1985
Unknown
Issued 30 November 1985 Resolved
PROVIDE CORRECT MOUNTING BRACKETS FOR PORTABLE FIRE EXTINGUISHERS WHERE NECESSARY.
Condition: Unknown
Due 30 November 1985
Resolved 30 November 1985
Unknown
Issued 30 November 1985 Resolved
PROVIDE 4 - 2 1/2 INCH FIRE NOZZLES FOR FIRE STATIONS 5, 6, 8 AND 21.
Condition: Unknown
Due 30 November 1985
Resolved 30 November 1985
Unknown
Issued 30 November 1985 Resolved
PROVIDE 83 PERSONAL FLOTATION LIGHTS FOR EXPOSURE SUITS MISSING THEM IAW 46CFR180.513(E).
Condition: Unknown
Due 30 November 1985
Resolved 30 November 1985
Unknown
Issued 30 November 1985 Resolved
PROVIDE CORRECT ZIPPER TYPE FLOTATION BELTS FOR 7 EXPOSURE SUITS.
Condition: Unknown
Due 30 November 1985
Resolved 30 November 1985
Unknown
Issued 30 November 1985 Resolved
AS NOTED IN CCGD8 MMT LETTER M-1270 OF 6 SEP 85, PROVIDE DOCUMENTATION THAT VMW DRAWINGS 1932-400 THROUGH 1932-403 ARE COAST GUARD APPROVED.
Condition: Unknown
Due 30 November 1985
Resolved 30 November 1985
Unknown
Issued 30 November 1985 Resolved
AS NOTED IN CCGD8 MMT LETTER M-1270 OF 6 SEP 85, PROVIDE COAST GUARD APPROVAL FOR DRAWING 1932-202, REV B, AUTOMATIC WATER DRAIN, THAT WAS RETURNED FOR REVIEW.
Condition: Unknown
Due 30 November 1985
Resolved 30 November 1985
Unknown
Issued 30 November 1985 Resolved
PROVIDE 110 QUARTS OF WATER FOR LIFEBOAT NUMBER 1.
Condition: Unknown
Due 30 November 1985
Resolved 30 November 1985
Unknown
Issued 30 November 1985 Resolved
PROVIDE 134 QUARTS OF WATER FOR LIFEBOAT NUMBER 2.
Condition: Unknown
Due 30 November 1985
Resolved 30 November 1985
Unknown
Issued 30 November 1985 Resolved
PROVIDE SERVICED 25 MAN B. F. GOODRICH LIFERAFT, S/N 25MMUS19, AND FORWARD A COPY OF THE SERVICING CERTIFICATE TO MSO HONOLULU. IF THIS LIFERAFT IS UNSERVICABLE, DAVIT LAUNCHED LIFEFAFTS MUST BE PROVIDED.
Condition: Unknown
Due 30 November 1985
Resolved 30 November 1985
Unknown
Issued 30 November 1985 Resolved
RENEW THE WASTED CABLE STUFFING TUBES THROUGH THE MAIN DECK AT THE PORT FORWARD COLUMN.
Condition: Unknown
Due 30 November 1985
Resolved 30 November 1985
Unknown
Issued 30 November 1985 Resolved
RENEW OR REPAIR AND PROVE WATERTIGHT ALL THE DEAD COVERS FOR THE PORT LIGHTS IN THE BALLAST CONTROL ROOM.
Condition: Unknown
Due 30 November 1985
Resolved 30 November 1985
Unknown
Issued 30 November 1985 Resolved
RENEW VAPOR TIGHT DOORS AROUND THE MUD PIT/MOON POOL AREA AS FOLLOWS: MUD PUMP ROOM (1), SACK ROOM (1), EMERGENCY GENERATOR ROOM (1), ENGINE ROOM (2), AND SCR ROOM (1).
Condition: Unknown
Due 30 November 1985
Resolved 30 November 1985
Unknown
Issued 30 November 1985 Resolved
PRIOR TO PLACING EITHER HEATING BOILER IN OPERATION, CONDUCT HYDROSTATIC TESTS AND OPERATIONAL TESTS ON BOTH BOILERS IN THE PRESENCE OF A CG MARINE INSPECTOR.
Condition: Unknown
Due 30 November 1985
Resolved 30 November 1985
Unknown
Issued 30 November 1985 Resolved
AS NOTED IN CCGD8 MMT LETTER M-1270 OF 6 SEP 85, REPLACE ALL ASBESTOS GASKETS IN THE HELICOPTER REFULING SYSTEM, OR PROVIDE DOCUMENTATION THAT OTHER TYPE GASKETS WERE ORIGINALLY INSTALLED.
Condition: Unknown
Due 30 November 1985
Resolved 30 November 1985
Unknown
Issued 29 September 1984 Resolved
PROVIDE AN OPERATION MANUAL FOR THE NO. 1 LIFEBOAT PER 46 CFR 108.503(G).
Condition: Unknown
Due 29 September 1984
Resolved 29 September 1984
Unknown
Issued 29 September 1984 Resolved
HYDROSTATICALLY TEST AT 1 1/4 TIMES THE MAWP (MAWP=2903 PSI) THE FOUR AIR CYLINDERS IN NO. 1 AND NO. 2 LIFEBOATS AND PROVIDE A COPY OF THE INSPECTIONREPORT TO [name withheld] PER 46 CFR 61.10-5(D).
Condition: Unknown
Due 29 September 1984
Resolved 29 September 1984
Unknown
Issued 29 September 1984 Resolved
ITEM E-3 ISSUED 3 OCTOBER 1983 IS OVERDUE. IT REQUIRED REPLACEMENT OF ALL BRASS VALVES USED ON THE FUEL SYSTEMS AND DRAINS. REPLACEMENT MUST COMPLY WITH 46 CFR 56.50-60(D)(2).
Condition: Unknown
Due 29 September 1984
Resolved 29 September 1984
Unknown
Issued 29 September 1984 Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 29 September 1984
Resolved 29 September 1984
Unknown
Issued 29 September 1984 Resolved
SUBMIT A FOAM SAMPLE FOR ANALYSIS AND PROVIDE RESULTS TO [name withheld] AS PER 46 CFR 107.235.
Condition: Unknown
Due 29 September 1984
Resolved 29 September 1984
Unknown
Issued 29 September 1984 Resolved
REPLACE THE SMALL PASS-THRU DOOR BETWEEN THE MESSROOM AND THE CORRIDOR TO RESTORE B-CLASS BULKHEAD AS ORIGINAL.
Condition: Unknown
Due 29 September 1984
Resolved 29 September 1984
Unknown
Issued 29 September 1984 Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 29 September 1984
Resolved 29 September 1984
Unknown
Issued 29 September 1984 Resolved
PROVIDE AN A-CLASS DOOR BETWEEN THE LAUNDRY AND THE STAIRWAY PER NVC 4-78 TO REPLACE THE ORIGINAL MISSING DOOR
Condition: Unknown
Due 29 September 1984
Resolved 29 September 1984
Unknown
Issued 29 September 1984 Resolved
RENEW ONE SET OF PROTECTIVE CLOTHING FOR THE FIREMAN OUTFIT PER 46 CFR 108.497(G).
Condition: Unknown
Due 29 September 1984
Resolved 29 September 1984
Unknown
Issued 29 September 1984 Resolved
PROVIDE ONE MESA OR MSHA APPROVED FIRST AID KIT SUITABLE FOR 80 PERSONS AS PER 46 CFR 108.707
Condition: Unknown
Due 29 September 1984
Resolved 29 September 1984
Unknown
Issued 29 September 1984 Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 29 September 1984
Resolved 29 September 1984
Unknown
Issued 29 September 1984 Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 29 September 1984
Resolved 29 September 1984
Unknown
Issued 29 September 1984 Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 29 September 1984
Resolved 29 September 1984
Unknown
Issued 29 September 1984 Resolved
PROVIDE SUPPORTS AND BANDING FOR ELECTRICAL CABLE THROUGHOUT THE RIG WHERE MISSING PER 46 CFR 111.60-25.
Condition: Unknown
Due 29 September 1984
Resolved 29 September 1984
Unknown
Issued 29 September 1984 Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 29 September 1984
Resolved 29 September 1984
Unknown
Issued 29 September 1984 Resolved
90 EXPOSURE SUITS ARE REQUIRED TO BE PLACED ONBOARD.
Condition: Unknown
Due 29 September 1984
Resolved 29 September 1984
Unknown
Issued 29 September 1984 Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 29 September 1984
Resolved 29 September 1984
Unknown
Issued 29 September 1984 Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 29 September 1984
Resolved 29 September 1984
Unknown
Issued 29 September 1984 Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 29 September 1984
Resolved 29 September 1984

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.