MAURY USCG vessel records
← All vessels

HER

HER is a 1983 passenger vessel (inspected). The Coast Guard has recorded 15 inspections since 2016, most recently in July 2025, along with 10 deficiencies.

Records from 2016 to 2025. Most recent: inspection, 29 July 2025.

Built
1983
Last inspected
29 July 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 29 July 2025
Operational controls None recorded without a removal date
Years with a record 8 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDD3001
228700
Flag
UNITED STATES
Maury page id
psix-228700

Documentation record

Registered dimensions (L × B × D)60.3 ft × 20.3 ft × 4.5 ft
Registered tonnagegross 38 / net 30
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderRANT CONTRACTING INC · PATCHOGUE, NY, UNITED STATES · built 1983
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portSAYVILLE, NY
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 24 April 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it30 - Simplified, Net Ton
38 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 15

29 July 2025 COI Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8197633
28 April 2025 Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8123412
2 December 2022 Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7603161
16 May 2022 DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7449885
16 April 2021 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7176345
19 January 2021 Plan Review "T" Boat · Examination of Repairs
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7131556
19 February 2020 Drydock Exam · Examination of Repairs · Deficiency Check · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6906308
5 February 2020 DAPI Audit · Re-Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6883152
14 March 2019 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6634166
7 December 2018 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6589097
27 March 2018 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6366080
15 February 2018 Internal Structural Exam · Hull Examination · Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6354983
7 April 2017 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6119200
2 February 2017 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6081418
20 April 2016 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5858570

Deficiency record · 10

03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 29 July 2025 Resolved
Railings not in accordance with 46 CFR 177.35-1.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 August 2025
Resolved 6 August 2025
Resolution: Railings installed.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 28 April 2025 Resolved
Descale vessel and make better available for further examination.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 28 April 2025
Resolved 6 June 2025
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 16 May 2022 Resolved
Vessel's DD/ISE expired on 31MAR2022 and needs to be completed and witnessed by USCG marine inspector prior to operations.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 June 2022
Resolved 2 December 2022
Resolution: Not resolved and must be verified at next COI issuance.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 16 May 2022 Resolved
First Aid Kit had expired aspirin and eye wash.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 June 2022
Resolved 2 December 2022
Resolution: Not resolved and must be verified at next COI issuance.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 May 2022 Resolved
O/O failed to provide proof of Drug and Alchol Program.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 June 2022
Resolved 2 December 2022
Resolution: Not resolved and must be verified at next COI issuance.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 5 February 2020 Resolved
Prior to getting underway complete proposed deck repairs with Marine Inspector oversight and complete credit dry dock.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 5 February 2020
Resolved 6 March 2020
Resolution: Planned hull/ deck plating was replaced with CG oversight during the repair process
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 February 2020 Resolved
Make the ring life buoy readily accessible. The ring life buoy was installed in a way which prevented the rapid deployment of the ring in an emergency. Vessel representative freed the life buoy and corrected the deficiency on the spot.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 5 February 2020
Resolved 5 February 2020
Resolution: Type IV PFD was reconfigured and stowed in a way that would allow for the rapid deployment in an emergency.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 5 February 2020 Resolved
Reconfigure navigation side lights, as discussed, to allow for the complete arc of visibility in accordance with 33 CFR 83.21 (b).
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 5 February 2020
Resolved 6 March 2020
Resolution: Navigation side lights moved to display full arc of visibility as prescribbed in the CG inland navigational rules of the road.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 February 2020 Resolved
Electrical equipment exposed to weather must be watertight. Stern navigation light case was identified damaged and not watertight. Replace Stern navigation light with a water tight enclosure and in accordance with 33 CFR 83.21 (c).
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 March 2020
Resolved 6 March 2020
Resolution: Stern light replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 February 2020 Resolved
Battery box for the starboard side main diesel engine must re built to prevent water splash and secured as high as practicable.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 March 2020
Resolved 6 March 2020
Resolution: Two battery boxes were replaced.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.