HER is a 1983 passenger vessel (inspected). The Coast Guard has recorded 53 inspections since 1987, most recently in July 2025, along with 93 deficiencies.

Records from 1987 to 2025. Most recent: inspection, 29 July 2025.

Built
1983
Last inspected
29 July 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDD3001
228700
Flag
UNITED STATES
367122570
Maury page id
psix-228700

Inspections, by type

…with no type recorded4
Years with a record 29 calendar years (1987–2025)
The 53 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)60.3 ft × 20.3 ft × 4.5 ft
Registered tonnagegross 38 / net 30
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderRANT CONTRACTING INC · PATCHOGUE, NY, UNITED STATES · built 1983
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portSAYVILLE, NY
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 24 April 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it30 - Simplified, Net Ton
38 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDR4156MMSI 367122570 · active · compulsorily equipped · granted 4 September 2026, expires 4 September 2036
WDD3001MMSI 367122570 · expired · voluntarily equipped · granted 21 April 2016, cancelled 25 July 2026
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 53

29 July 2025 COI Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8197633
28 April 2025 Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8123412
2 December 2022 Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7603161
16 May 2022 DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7449885
16 April 2021 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7176345
19 January 2021 Plan Review "T" Boat · Examination of Repairs
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7131556
19 February 2020 Drydock Exam · Examination of Repairs · Deficiency Check · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6906308
5 February 2020 DAPI Audit · Re-Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6883152
14 March 2019 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6634166
7 December 2018 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6589097
27 March 2018 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6366080
15 February 2018 Internal Structural Exam · Hull Examination · Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6354983
7 April 2017 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6119200
2 February 2017 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6081418
20 April 2016 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5858570
22 February 2011 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3947316
3 March 2010 COI Inspection · DAPI Audit
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3687637
8 April 2009 Deficiency Check · Drydock Extension · Internal Structural Exam · Annual Inspection · Hull Examination
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3448839
13 May 2008 Deficiency Check · Re-Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3206131
30 January 2008 Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3138994
15 May 2007 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2931004
19 January 2007 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2858512
16 May 2006 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2653521
2 February 2005 COI Inspection · Examination of Repairs
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 2282529
9 June 2004 Annual Inspection · MARPOL Annex V Examination
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 2078163
29 June 2003 Deficiency Check
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1829638
18 June 2003 MARPOL Annex V Examination · Annual Inspection
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1816622
25 October 2002 Hull Examination · Internal Structural Exam
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1695395
25 June 2002 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1635532
30 October 2001 Hull Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1444635
4 May 2001 Deficiency Check · Re-Inspection · MARPOL Annex V Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1470030
26 April 2000 Hull Examination · Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1379042
14 April 2000 Deficiency Check · MARPOL Annex V Examination · COI Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1361392
10 March 2000 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1410236
14 April 1999 Deficiency Check · Re-Inspection · MARPOL Annex V Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1416909
13 May 1998 Hull Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 795193
29 April 1998 MARPOL Annex V Examination · Re-Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1129820
4 April 1997 COI Inspection · MARPOL Annex V Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1107222
6 February 1997 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 773329
23 October 1996 Hull Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 857446
22 July 1996 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1084768
28 June 1996 Drydock Extension
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1245619
20 May 1996 Re-Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1084705
5 May 1995 COI Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 877985
27 April 1994 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1159740
13 April 1994 Re-Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 849570
6 October 1993 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1135005
11 June 1993 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 846125
7 June 1993 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 213850
3 February 1993 Plan Review "T" Boat · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1156499
31 December 1992 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1132883
10 December 1992 Plan Review "T" Boat
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1137994
15 September 1987 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1313860

Deficiency record · 93

03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 29 July 2025 Resolved
Railings not in accordance with 46 CFR 177.35-1.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 August 2025
Resolved 6 August 2025
Resolution: Railings installed.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 28 April 2025 Resolved
Descale vessel and make better available for further examination.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 28 April 2025
Resolved 6 June 2025
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 16 May 2022 Resolved
Vessel's DD/ISE expired on 31MAR2022 and needs to be completed and witnessed by USCG marine inspector prior to operations.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 June 2022
Resolved 2 December 2022
Resolution: Not resolved and must be verified at next COI issuance.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 16 May 2022 Resolved
First Aid Kit had expired aspirin and eye wash.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 June 2022
Resolved 2 December 2022
Resolution: Not resolved and must be verified at next COI issuance.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 May 2022 Resolved
O/O failed to provide proof of Drug and Alchol Program.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 June 2022
Resolved 2 December 2022
Resolution: Not resolved and must be verified at next COI issuance.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 5 February 2020 Resolved
Prior to getting underway complete proposed deck repairs with Marine Inspector oversight and complete credit dry dock.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 5 February 2020
Resolved 6 March 2020
Resolution: Planned hull/ deck plating was replaced with CG oversight during the repair process
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 February 2020 Resolved
Make the ring life buoy readily accessible. The ring life buoy was installed in a way which prevented the rapid deployment of the ring in an emergency. Vessel representative freed the life buoy and corrected the deficiency on the spot.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 5 February 2020
Resolved 5 February 2020
Resolution: Type IV PFD was reconfigured and stowed in a way that would allow for the rapid deployment in an emergency.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 5 February 2020 Resolved
Reconfigure navigation side lights, as discussed, to allow for the complete arc of visibility in accordance with 33 CFR 83.21 (b).
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 5 February 2020
Resolved 6 March 2020
Resolution: Navigation side lights moved to display full arc of visibility as prescribbed in the CG inland navigational rules of the road.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 February 2020 Resolved
Electrical equipment exposed to weather must be watertight. Stern navigation light case was identified damaged and not watertight. Replace Stern navigation light with a water tight enclosure and in accordance with 33 CFR 83.21 (c).
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 March 2020
Resolved 6 March 2020
Resolution: Stern light replaced.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 February 2020 Resolved
Battery box for the starboard side main diesel engine must re built to prevent water splash and secured as high as practicable.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 March 2020
Resolved 6 March 2020
Resolution: Two battery boxes were replaced.
Construction/Loadline › Hull › Hull Plating
Issued 22 February 2011 Resolved
Crop to good metal & renew wasted plate IWO Fx on port side shell just above chine intersection at approximately 25' from bow.
Action required: 705 - Other - as specified
Resolved 7 March 2011
Resolution: Plate inserted 3'''' X 2.5'''' X 1/4" hose tested satisfactory. (Master''s list.)
Construction/Loadline › Hull › Hull Plating
Issued 22 February 2011 Resolved
Crop to good metal & renew bow & side shell at port bow.
Action required: 705 - Other - as specified
Resolved 7 March 2011
Resolution: Plate inserted 10'' X 4.0'' X 1/4" & 2'' X 1.5'' X1/4" hose tested satisfactory.
Construction/Loadline › Hull › Hull Plating
Issued 22 February 2011 Resolved
Crop to good metal & renew bow & side shell plate at the stbd bow. (Master's list.)
Action required: 705 - Other - as specified
Resolved 7 March 2011
Resolution: Plate inserted 3'''' X 2'''' X 1/4" hose tested satisfactory.
Construction/Loadline › Hull › Sheerstrake
Issued 22 February 2011 Resolved
Renew rubrails port. stbd, aft & fwd. Current split pipe rubrail is wasted, bent, fx's and holed. 3.2.11 Owner called; he has 5" sch 40 pipe available to replace worn rubrail.
Action required: 705 - Other - as specified
Resolved 7 March 2011
Resolution: Rub rail renewed in its entirety.
Construction/Loadline › Hull › Strut/Cross Tie
Issued 22 February 2011 Resolved
Reweld one stanchion and one diagonal chord that have Fx welds as marked in fwd end of main compartment. One is on fourth transverse bottom fr from the collision bhd on the stbd side and the other is on the diagonal inboard from the side shell Fx on the port side. (Master's list.)
Action required: 705 - Other - as specified
Resolved 7 March 2011
Resolution: Completed sat.
Engineering › Shafting/Propeller Arrangements › Strut Bearing
Issued 22 February 2011 Resolved
Replace worn shaft bearing tube and associated bearing for stbd prop shaft. (Master's list.)
Action required: 705 - Other - as specified
Resolved 7 March 2011
Resolution: Completed sat.
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 22 February 2011 Resolved
Replace worn shaft bearings for port & stbd shafts.
Action required: 705 - Other - as specified
Resolved 7 March 2011
Resolution: Renewed.
Engineering › Steering Gear System › Rudder
Issued 22 February 2011 Resolved
Repack rudder shaft seals. (Master's list.)
Action required: 705 - Other - as specified
Resolved 7 March 2011
Resolution: Replaced.
Engineering › Steering Gear System › Rudder Stock
Issued 22 February 2011 Resolved
Repair or replace rudder stock. Pins at connection to quadrants are worn beyond repair. Quadrants need to be fitted w/ keys & keyways or other means to remove play with lock bolts after machining to a snug fit. Have yard machinist present repair proposal to the inspector prior to starting repair.
Action required: 705 - Other - as specified
Resolved 7 March 2011
Resolution: Bell crank / quadrant arms replaced and new bushings fitted. lock bolts fitted & cranks welded to shafts. New tie rod machined & fitted. Steering gear is tight & sound. Tested sat.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 3 March 2010 Resolved
Worn deck rail had been temporarily replaced by loose fitting chains usually utilized for securing loads. Life lines require dedicated properly fitting components.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 March 2010
Resolved 9 March 2010
Resolution: New chains fitted w/ pelican hooks to permit quick removal and erection during cargo operations. fixed components of rail system repaired w/ new purchases to connect lifelines to.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 3 March 2010 Resolved
Seven adult PFDs need to be replaced due to recent welding spatter damage IWO storage area. One PFD needs new retro-reflective tape.
Action required: 705 - Other - as specified
Due 31 March 2010
Resolved 3 March 2010
Resolution: Corrected during exam.
Construction/Loadline › Hull › Bottom Plating
Issued 8 April 2009 Resolved
Obtain credit for hull exam, or extension, prior to operating.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 May 2009
Resolved 15 April 2009
Operations/Management › Drills/Instruction › Making Voice Radio Distress Call
Issued 8 April 2009 Resolved
Fill out and post emergency radio distress instructions prior to operating
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 May 2009
Resolved 15 April 2009
Documentation › Markings/Placards › Lifejacket Placard
Issued 8 April 2009 Resolved
Post ledgible lifejacket donning instructions prior to operating.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 May 2009
Resolved 15 April 2009
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 8 April 2009 Resolved
Provide CG approved waterlight for life ring prior to operating.
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 May 2009
Resolved 15 April 2009
Operations/Management › Navigation Safety › Proper Use of Navigation/Anchor Lights
Issued 8 April 2009 Resolved
Repair nav lights prior to operating at night.
Due 9 May 2009
Resolved 15 April 2009
Lifesaving › Buoyant Apparatus › Lifeline
Issued 14 May 2008 Resolved
Replace worn pendants, lifeline and properly rig sea painter.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 May 2008
Resolved 16 May 2008
Resolution: Corrected
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 13 May 2008 Resolved
Mount R/B & waterlight.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 May 2008
Resolved 16 May 2008
Resolution: Completed.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 13 May 2008 Resolved
Replace 60' line.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 May 2008
Resolved 16 May 2008
Resolution: Replaced.
Communications › Alarms/Indicators › Bilge Alarm
Issued 13 May 2008 Resolved
Repair bilgr alarm.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 16 May 2008
Resolved 16 May 2008
Resolution: Repaired.
Engineering › Diesel Engine (propulsion-reduction gear) › Block
Issued 13 May 2008 Resolved
MDE renewed by owner during winter lay-up.
Action required: 705 - Other - as specified
Due 13 May 2008
Resolved 13 May 2008
Resolution: Examined installation. All exhausts, fuel piping, wiring renewed. Installation tested and examined. Found sat. Machinery materials & installation per mfg installation guide & IAW CG regulations for subchapter T vessels.
Fire Fighting › Fire Pumps › Capacity
Issued 13 May 2008 Resolved
Combination fire & bilge pump renewed. Jabsco ITT 1.5" bronze self priming pump fitted in place of previous 1" pump.
Action required: 705 - Other - as specified
Due 13 May 2008
Resolved 13 May 2008
Resolution: Tested and found sat. MISLE data under pump capacity updated.
Lifesaving › Hand Flares › Expired
Issued 13 May 2008 Resolved
Hand distress signals replaced by O/O prior to inspection.
Action required: 705 - Other - as specified
Due 13 May 2008
Resolved 13 May 2008
Resolution: Corrected prior to inspection.
Stability › Incline Test › General
Issued 30 January 2008 Resolved
Conduct stability test
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 31 March 2009
Resolved 13 May 2008
Resolution: Stability and loading data are already included on COI per 46 CFR 170.120(b) of OLD "T".
Construction/Loadline › Hull › Hull Plating
Issued 19 January 2007 Resolved
First strake inboard of the chine C&R from bow to approx 40' aft of collision BHD. Bottom/bow plate IWO fwd rake C&R.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 March 2007
Resolved 21 March 2007
Resolution: Examined & hose tested.
Construction/Loadline › Hull › Transverse Frame
Issued 19 January 2007 Resolved
Reweld as marked and C&R to good metal wasted transverse frames fwd.
Condition: Improper/Lack of Maintenance
Due 31 March 2007
Resolved 21 March 2007
Engineering › Fuel Oil Service System › Piping
Issued 19 January 2007 Resolved
Repair damaged fill pipe on maindeck.
Condition: Design Flaw
Due 31 March 2007
Resolved 21 March 2007
Resolution: Pipe replaced in kind but moved 1'' towards port side of vessel from original location to prevent damage from vehicle wheels on deck.
Construction/Loadline › Structures › Deck Plating
Issued 19 January 2007 Resolved
Maindeck C&R in an irregular shape to approximately 25' aft of bow. (N.B. on stbd side of deck C&R to approximately 3' aft of E/R escape hatch. New deck plate reinforced to resist damage from vehicles operating on deck.
Condition: Design Flaw
Due 31 March 2007
Resolved 21 March 2007
Resolution: Examined & hose tested.
Fire Fighting › Nozzles › Condition
Issued 16 May 2006 Resolved
Provide new fire nozzle.
Due 23 May 2006
Resolved 26 May 2006
Resolution: Per fax ltr fm O/O, letter scanned into documents for this activity.
Documentation › Certificates/Documents › FCC SSL
Issued 16 May 2006 Resolved
Provide FCC radio license.
Due 30 May 2006
Resolved 26 May 2006
Resolution: Per fax ltr fm O/O, letter scanned into documents for this activity.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 2 February 2005 Resolved
Replace leaking exhaust piping on the starboard main engine.
Due 8 April 2005
Resolved 31 March 2005
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 2 February 2005 Resolved
Repair anchor light, vessel limited to daylight operations.
Due 8 April 2005
Resolved 7 April 2005
Engineering › Fuel Oil Service System
Issued 9 June 2004 Resolved
Provide proper flame screen for fuel vent. LEGACY COMPONENT DESC: Flame screen
Due 16 June 2004
Resolved 17 June 2004
Electrical › Electric Supply System (service)
Issued 9 June 2004 Resolved
Provide covers for battery boxes. LEGACY COMPONENT DESC: Battery Installation
Due 16 June 2004
Resolved 17 June 2004
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 9 June 2004 Resolved
Mount an additional fire extinguisher bracket. LEGACY COMPONENT DESC: Mounting Bracket
Due 16 June 2004
Resolved 17 June 2004
Navigation › Piloting/Steering
Issued 9 June 2004 Resolved
Repair compass light. LEGACY COMPONENT DESC: Compass
Due 16 June 2004
Resolved 17 June 2004
Fire Fighting
Issued 18 June 2003 Resolved
Service fire fighting systems.
Due 30 June 2003
Resolved 27 June 2003
Construction/Loadline › Structures
Issued 25 October 2002 Resolved
Renew Aft port hatch IWO eingine space in its entirety (temporary plastic patch permitted until 15Nov02). LEGACY COMPONENT DESC: Machinery Space Opening
Condition: Improper/Lack of Maintenance
Due 16 December 2002
Resolved 18 June 2003
Construction/Loadline › Structures
Issued 25 October 2002 Resolved
Renew wasted door sill IWO engine room access (must be at least 3" high). LEGACY COMPONENT DESC: Door
Condition: Improper/Lack of Maintenance
Due 16 December 2002
Resolved 18 June 2003
Construction/Loadline › Structures
Issued 25 October 2002 Resolved
Crop out & renew wheelhouse deck & outside shell plate of wheelhouse. (Reweld fractured stiffeners & insure radius corners or stress relieving is used. No inserts less than 1' X 2'.). LEGACY COMPONENT DESC: Superstructure
Condition: Improper/Lack of Maintenance
Due 16 December 2002
Resolved 18 June 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 25 October 2002 Resolved
Renew wasted hand rail near bridge lader. LEGACY COMPONENT DESC: Deck Rail
Condition: Improper/Lack of Maintenance
Due 16 December 2002
Resolved 18 June 2003
Accommodation/Occupational Safety › Ventilation
Issued 25 October 2002 Resolved
Repair holed vent on stbd side of main deck near engine room access.
Condition: Improper/Lack of Maintenance
Due 16 December 2002
Resolved 18 June 2003
Lifesaving › Buoyant Apparatus
Issued 25 June 2002 Resolved
Provide sea painter for life floats.
Condition: Improper Installation
Due 14 July 2002
Resolved 27 June 2002
Resolution: 100 foot sea painter added.
Lifesaving › Buoyant Apparatus
Issued 25 June 2002 Resolved
Replace wasted tag lines for life floats.
Due 14 July 2002
Resolved 27 June 2002
Resolution: Tag lines replaced.
Lifesaving › Buoyant Apparatus
Issued 25 June 2002 Resolved
Repair small rip in aft life float.
Due 14 July 2002
Resolved 27 June 2002
Resolution: Repaired with clear silicon.
Lifesaving › Buoyant Apparatus
Issued 25 June 2002 Resolved
Mark paddles with vessel name and stow with life floats.
Condition: Improper Installation
Due 14 July 2002
Resolved 27 June 2002
Resolution: Marked and stowed in vicinity.
Lifesaving › Buoyant Apparatus
Issued 25 June 2002 Resolved
Provide and attach waterlights to life floats.
Condition: Improper Installation
Due 14 July 2002
Resolved 27 June 2002
Resolution: New waterlights purchased and attached.
Communications › Radio Communications
Issued 25 June 2002 Resolved
Provide and post emergency broadcast placard.
Condition: Improper Installation
Due 14 July 2002
Resolved 27 June 2002
Resolution: Provided and posted.
Fire Fighting › Fire Pumps
Issued 25 June 2002 Resolved
Repair leak from fire pump.
Condition: Improper/Lack of Maintenance
Due 14 July 2002
Resolved 27 June 2002
Resolution: Leak repaired by replacing worn gasket with new one.
Engineering
Issued 25 June 2002 Resolved
Remove oil/water mixture from under engine beds.
Condition: Improper/Lack of Maintenance
Due 14 July 2002
Resolved 27 June 2002
Resolution: Removed.
Engineering › Shafting/Propeller Arrangements
Issued 25 June 2002 Resolved
Reduce water flow from port and stbd shaft packing. LEGACY COMPONENT DESC: Propeller Shaft
Condition: Improper/Lack of Maintenance
Due 14 July 2002
Resolved 27 June 2002
Resolution: Repacked.
Documentation › Certificates/Documents
Issued 25 June 2002 Resolved
Provide radiotelephony safety certificate.
Condition: Unknown
Due 14 July 2002
Resolved 27 June 2002
Resolution: FCC certificate supplied.
Navigation
Issued 4 May 2001 Resolved
PROVIDE UP-TO-DATE CHARTS.
Condition: Unknown
Due 11 May 2001
Resolved 20 June 2001
Lifesaving
Issued 4 May 2001 Resolved
PROVIDE AN ACCEPTABLE SYSTEM FOR STOWAGE OF L/FS.
Condition: Unknown
Due 11 May 2001
Resolved 20 June 2001
Engineering
Issued 26 April 2000 Resolved
RENEW CUTLESS BEARINGS, PORT AND STBD SIDES.
Condition: Unknown
Due 12 May 2000
Resolved 9 May 2000
Construction/Loadline
Issued 26 April 2000 Resolved
RENEW WASTED METAL IWO HOUSE/DECK JUNCTION, PORTSIDE.
Condition: Unknown
Due 12 May 2000
Resolved 9 May 2000
Navigation
Issued 26 April 2000 Resolved
REBUSH STEERING CONNECTIONS TO ELIMINATE SLOP.
Condition: Unknown
Due 12 May 2000
Resolved 9 May 2000
Engineering
Issued 14 April 2000 Resolved
PROVIDE AND INSTALL MEANS OF SHUTTING DOWN MDE WHICH IS INDEPENDENT OF THE ENGINE SPEED CONTROL.
Condition: Unknown
Due 30 April 2000
Resolved 26 April 2000
Lifesaving
Issued 14 April 2000 Resolved
PROVIDE AND INSTALL 1 FLOATING WATER LIGHT. NO NIGHT OPS UNTIL CLEARED.
Condition: Unknown
Due 30 April 2000
Resolved 26 April 2000
Lifesaving
Issued 14 April 1999 Resolved
REPAIR LIFE FLOATS. NO PASSENGERS FOR HIRE UNTIL CLEARED.
Condition: Unknown
Due 28 April 1999
Resolved 17 June 1999
Electrical
Issued 14 April 1999 Resolved
PROVE PROPER OPERATION OF HORN.
Condition: Unknown
Due 25 June 1999
Resolved 29 June 1999
Navigation
Issued 14 April 1999 Resolved
SHOW PROPER OPERATION OF STERN LIGHT. NO NIGHT OPERATION UNTIL CLEARED.
Condition: Unknown
Due 25 June 1999
Resolved 17 June 1999
Lifesaving
Issued 14 April 1999 Resolved
PROVE OPERATION OF THE 1 INOPERATIVE FLOATING WATER LIGHT. NO NIGHT OPERATION UNTIL CLEARED.
Condition: Unknown
Due 28 April 1999
Resolved 17 June 1999
Lifesaving
Issued 14 April 1999 Resolved
PROVIDE 1 RING BUOY. NO PASSENGERS FOR HIRE UNTIL CLEARED.
Condition: Unknown
Due 28 April 1999
Resolved 17 June 1999
Lifesaving
Issued 14 April 1999 Resolved
PROVIDE 2 WORKING FLASH LIGHTS.
Condition: Unknown
Due 28 April 1999
Resolved 17 June 1999
Lifesaving
Issued 14 April 1999 Resolved
PROVIDE AND POST EMERGENCY BROADCAST PLACARD NEXT TO R/T EQUIPMENT.
Condition: Unknown
Due 28 April 1999
Resolved 17 June 1999
Lifesaving
Issued 14 April 1999 Resolved
PROVIDE AND POST PFD DONNING PLACARD FOR BOTH TYPES OF PFDS.
Condition: Unknown
Due 28 April 1999
Resolved 17 June 1999
Unknown
Issued 14 April 1999 Resolved
MAKE VESSEL READY FOR INSPECTION.
Condition: Unknown
Due 28 April 1999
Resolved 17 June 1999
Navigation
Issued 14 April 1999 Resolved
PROPERLY SECURE/RENEW PORT AND STBD RUNNING LIGHTS. NO NIGHT OPERATION UNTIL CLEARED.
Condition: Unknown
Due 25 June 1999
Resolved 29 June 1999
Accommodation/Occupational Safety
Issued 20 May 1996 Resolved
INSTALL RAILS / LIFELINES ABOUT THE PERIMETER OF THE MAIN DECK.
Condition: Unknown
Due 24 July 1996
Resolved 24 July 1996
Fire Fighting
Issued 20 May 1996 Resolved
PROVIDE A FIRE AXE.
Condition: Unknown
Due 24 July 1996
Resolved 24 July 1996
Navigation
Issued 20 May 1996 Resolved
PROVIDE A VHF-FM MARINE RADIO W/ A CURRENT STATION LICENSE.
Condition: Unknown
Due 24 July 1996
Resolved 24 July 1996
Construction/Loadline
Issued 20 May 1996 Resolved
PROVIDE DRAFT MARKS.
Condition: Unknown
Due 24 July 1996
Resolved 24 July 1996
Accommodation/Occupational Safety
Issued 20 May 1996 Resolved
INSTALL SAFETY RAILS ABOUT ALL ELEVATED WORK AREAS.
Condition: Unknown
Due 24 July 1996
Resolved 24 July 1996
Navigation
Issued 20 May 1996 Resolved
PROVIDE A BELL & PROVE OPERATION OF HORN.
Condition: Unknown
Due 24 July 1996
Resolved 24 July 1996
Lifesaving
Issued 20 May 1996 Resolved
REMARK RING BUOY W/ VESSEL'S NAME.
Condition: Unknown
Due 24 July 1996
Resolved 24 July 1996
Lifesaving
Issued 20 May 1996 Resolved
REBUILD OR REPLACE THE BUOYANT APPARATUS.
Condition: Unknown
Due 24 July 1996
Resolved 24 July 1996
Fire Fighting
Issued 20 May 1996 Resolved
PROVIDE A NOZZEL FOR THE FIRE HOSE.
Condition: Unknown
Due 24 July 1996
Resolved 24 July 1996
Lifesaving
Issued 13 April 1994 Resolved
PROVIDE SEA PAINTER AND WATERLIGHT FOR BUOYANT APPARATUS.
Condition: Unknown
Due 24 February 1995
Resolved 24 February 1995
Documentation
Issued 13 April 1994 Resolved
PROVIDE COPIES OF EPA SHORE PROTECTION ACT ENDORSEMENT AND LTR REFERENCING NIGHT OPERATIONS.
Condition: Unknown
Due 24 February 1995
Resolved 24 February 1995
Lifesaving
Issued 13 April 1994 Resolved
PROVIDE A WATERTIGHT BOX FOR DISTRESS SIGNALS.
Condition: Unknown
Due 24 February 1995
Resolved 24 February 1995
Documentation
Issued 13 April 1994 Resolved
MARK NAME OF VSL ON STERN
Condition: Unknown
Due 24 February 1995
Resolved 24 February 1995
Construction/Loadline
Issued 3 February 1993 Resolved
PRESENT VESSEL FOR COMPLETE DRYDOCK EXAM NO LATER THAN 31 MAY 1993. SUBMIT LETTER STATING VESSEL'S SUITABILITY FOR CONTINUED SAFE OPERATION THROUGHOUTTHIS PERIOD NO LATER THAN 8 FEBRUARY 1993.
Condition: Unknown
Due 30 June 1993
Resolved 30 June 1993

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.