OPUS

OPUS is a 1983 passenger vessel (inspected). The Coast Guard has recorded 110 inspections since 1985, most recently in July 2026, along with 185 deficiencies — 2 with no resolution recorded —, 1 operational control and 2 casualty investigations between 2016 and 2026.

Records from 1985 to 2026. Most recent: operational control imposed, 8 July 2026.

Built
1983
Last inspected
8 July 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDQ3672
228701
Flag
UNITED STATES
367175570, 368418950
Maury page id
psix-228701

Inspections, by type

…with no type recorded5
…past their stated due date1
Years with a record 41 calendar years (1985–2026)
The 110 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)93.5 ft × 28.0 ft × 5.0 ft
Registered tonnagegross 97 / net 66
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderPROSPECT BOAT WORKS INC · PROSPECT, KY, UNITED STATES · built 1983
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portMIAMI, FL
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationValid · issued 21 February 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it66 - Regulatory (Subpart C or D), Net Ton
0 - Dead Weight, Ton
97 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDQ3672MMSI 368418950 · active · compulsorily equipped · granted 13 May 2025, expires 13 May 2035
WDJ5564MMSI 367175570 · active · compulsorily equipped · granted 16 May 2017, expires 16 May 2027
WDD6635MMSI 367175570 · terminated · compulsorily equipped · granted 26 March 2007, cancelled 12 May 2017
WRE2497MMSI not assigned · expired · compulsorily equipped · granted 17 September 1998, cancelled 14 February 2009 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 110

8 July 2026 MTSA Verification · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8432995
24 May 2026 Damage Survey · Examination of Repairs · Annual Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8379417
19 May 2025 COI Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8123825
25 March 2025 Hull Examination · Deficiency Check · Internal Structural Exam · Construction Oversight · Administrative Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8099543
8 August 2024 Annual Inspection · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7963961
3 April 2024 Drydock Exam · Internal Structural Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7886888
11 August 2023 Annual Inspection · MTSA Verification
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7765825
31 May 2023 In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7703871
16 May 2022 Administrative Inspection · Deficiency Check · COI Inspection · MTSA Verification
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7452146
7 April 2022 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7426287
31 January 2022 Internal Structural Exam · Drydock Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7386136
10 August 2021 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7271529
25 August 2020 MTSA Verification · Annual Inspection · Administrative Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7036401
17 March 2020 Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6924433
24 July 2019 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6755485
16 August 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6514006
13 August 2018 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6510391
16 July 2018 Annual Inspection · MTSA Verification
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6477993
3 May 2018 Drydock Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6404455
13 July 2017 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6216346
20 June 2017 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6181413
12 June 2017 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 6169586
30 May 2017 Administrative Inspection · Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6166470
19 May 2017 COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6144830
7 September 2016 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5994345
18 August 2016 MTSA Verification · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5973313
11 July 2016 Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5937621
29 June 2016 Damage Survey
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5924146
29 June 2016 Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 5938514
13 August 2015 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5214749
12 August 2015 MTSA Verification · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5201818
14 October 2014 Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5004899
6 August 2014 Annual Inspection · Internal Structural Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4945788
21 May 2012 DAPI Audit · COI Inspection · Internal Structural Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4293342
24 August 2011 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4126084
16 August 2011 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4111600
28 October 2010 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3882427
21 July 2009 MTSA Verification · Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3540638
27 April 2009 Drydock Extension · Internal Structural Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3462258
15 October 2008 Administrative Inspection
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 3345233
2 September 2008 Deficiency Check
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3318838
13 August 2008 MTSA Verification · Annual Inspection · Internal Structural Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3285978
30 May 2008 Inclining Experiment
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3224959
1 May 2008 Excursion Permit
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 3196608
24 April 2008 Excursion Permit
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 3191080
18 September 2007 Excursion Permit
Administrative · Sector Virginia · USCG East District (CGD-E) · Activity 3060517
16 May 2007 COI Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2932236
12 February 2007 Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2870859
17 October 2006 Permit to Proceed · In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2802525
31 July 2006 Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 2787344
30 January 2006 Annual Inspection · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2353948
10 January 2005 Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2269328
17 November 2004 MTSA Verification
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2241411
21 September 2004 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2197400
29 June 2004 Administrative Inspection
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2114681
9 February 2004 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2003161
9 January 2004 Deficiency Check · Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1970913
4 December 2003 Administrative Inspection
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1670720
9 January 2003 Annual Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1724311
28 August 2002 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1661451
20 December 2001 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1477105
26 October 2001 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1379622
24 October 2001 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1069891
23 August 2001 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1076282
20 April 2001 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1063169
22 January 2001 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1393600
6 September 2000 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1415462
14 December 1999 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1410215
2 November 1998 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1465435
9 September 1998 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1465434
5 January 1998 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1109174
24 November 1997 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1368497
15 January 1997 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1100202
12 November 1996 Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1385839
4 September 1996 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1355939
1 February 1996 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1080208
13 November 1995 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 881174
7 September 1995 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1193200
4 May 1995 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1182524
10 January 1995 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1172670
15 November 1994 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 864632
24 May 1994 Excursion Permit
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 859843
29 November 1993 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1160726
8 September 1993 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1146588
29 December 1992 COI Inspection · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 832379
3 January 1992 COI Inspection · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1269090
16 September 1991 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 941132
4 September 1991 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1253709
26 February 1991 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 924147
4 January 1991 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 931265
3 December 1990 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 901720
27 November 1990 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 918176
23 June 1990 Deficiency Check · Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 932073
13 April 1990 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1240733
6 February 1990 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 903396
5 January 1990 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1220920
28 November 1989 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 921639
6 September 1989 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1328495
2 August 1989 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1039877
13 June 1989 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1032604
14 March 1989 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 895544
10 February 1989 Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1348177
5 January 1989 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1341602
19 July 1988 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1344754
5 January 1988 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1322859
13 May 1987 Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1330590
12 January 1987 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1005443
8 July 1986 Credit Drydock
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1299712
25 February 1986 COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1297135
28 February 1985 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1286494

Deficiency record · 185

99 - Other › N/A - No Subsystem › Other (SOLAS operational)
Issued 8 July 2026 Resolved
The security plan under ASP states the VSO is the Master [name withheld] stated that is not the case and they purposely didn't want the Master as the VSO. Provide a designation of an appropriate VSO.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 July 2026
Resolution: CSO designated VSO and added to security plan ASP.
99 - Other › N/A - No Subsystem › Other (SOLAS operational)
Issued 8 July 2026 Resolved
Vessel CSO or VSO could not provide a schematic of vessel showing designated restricted areas to make the ASP more vessel specific. Provide a schematic with designated restricted areas of vessel.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 July 2026
Resolution: CSO provided vessel schematic identifying restricted areas.
99 - Other › N/A - No Subsystem › Other (SOLAS operational)
Issued 8 July 2026 Resolved
Vessel security records show drills haven not been conducted once every three months. Conduct and log a security drill prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 July 2026
Resolution: VSO conducted security drill and provided security record.
99 - Other › N/A - No Subsystem › Other (SOLAS operational)
Issued 8 July 2026 Resolved
CSO/VSO failed to notify the National Response Center of a Breach of Security after vessel crew member was notified of a "shooting incident" onboard the vessel during the charter. CSO/VSO must review vessel ASP and notification requirements for Breach of Security.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 July 2026
Resolution: Met with CSO and VSO questioned about their ASP and security protocols. Observed positive feedback during interview of CSO and VSO.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 June 2026 Resolved
Each portable fire extinguisher on a vessel must be of a type approved by the Commandant. The minimum number of portable fire extinguishers required on a vessel must be acceptable to the cognizant OCMI, but must be not less than the minimum number required by table 1 to § 118.500(b) and other provisions of this section. Portable extinguishers have not been inspected monthly and logged as required.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2026
Resolved 30 June 2026
Resolution: Log created for monthly fire extinguisher checks.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 June 2026 Resolved
A vessel of more than 19.8 meters (65 feet) in length must carry a minimum of three life buoys of not less than 610 millimeters (24 inches) in diameter. Vessel is missing one of the required three life buoys.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2026
Resolved 30 June 2026
Resolution: Missing life ring obtained and labeled.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 24 May 2026 No resolution recorded
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI. Vessel owner made alterations to the stern of the vessel around swim platform that were never approved by the local OCMI. Vessel is restricted from carrying passengers until alterations are removed and properly approved.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 June 2026 — due date passed with no resolution recorded
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 24 May 2026 Resolved
For vessels other than those covered in paragraphs (b) and (c) of this section, the name of the vessel must be marked on some clearly visible exterior part of the port and starboard bow and the stern of the vessel. The hailing port of the vessel must be marked on some clearly visible exterior part of the stern of the vessel. Must be made in clearly legible letters of the Latin alphabet or Arabic or Roman numerals not less than four inches in height. Vessel is missing name on stern.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2026
Resolved 30 June 2026
Resolution: Vessel name properly labeled on bow and stern as required.
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 24 May 2026 Resolved
The master shall conduct sufficient fire drills to make sure that each crew member is familiar with his or her duties in case of a fire. A fire drill must be conducted at least once each month. Drills were not being conducted as required.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 10 June 2026
Resolved 10 June 2026
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 24 May 2026 Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station man overboard conditions. Man overboard instruction did not contain procedures for using rescue boat.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2026
Resolved 30 June 2026
Resolution: Man over board instructions updated to include rescue boat.
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - intoxication
Issued 24 May 2026 Resolved
Alcohol-testing devices must be used according to the procedures specified by the manufacturer of the testing device and by this part. Alcohol swabs onboard were expired.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 June 2026
Resolved 30 June 2026
Resolution: New alcohol swabs obtained.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 19 May 2025 Resolved
Each portable fire extinguisher on a vessel must be of a type approved by the Commandant. The minimum number of portable fire extinguishers required on a vessel must be acceptable to the cognizant [name withheld] witnessed three fire extingiushers with broken tamper seals. MI required new servicing report for those identified.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2025
Resolved 27 May 2025
Resolution: Servicing for equipment complete.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 19 May 2025 Resolved
This part is intended to provide a minimum standard of regulations for electrical installations and equipment that will results in a vessel that is reasonably safe from fire caused by and/or originating in electrical equipment and reasonably safe from electrical shock of person. MI identified missing cover on electrical outlet in mens head.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2025
Resolved 27 May 2025
Resolution: Electrical covers installed.
10 - Safety of Navigation › N/A - No Subsystem › Electronic charts (ECDIS)
Issued 19 May 2025 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: Charts of large enough scale to make safe navigation possible. Operator could not prove when electronic charts were last updated.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2025
Resolved 27 May 2025
Resolution: electronic charts updated.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 19 May 2025 Resolved
The following vessels must have on board a properly installed, operational Coast Guard type-approved AIS Class A device:A self-propelled vessel that is certificated to carry more than 150 passengers. MI identified AIS vessel information is not update.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2025
Resolved 27 May 2025
Resolution: AIS information updated.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 19 May 2025 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date:(2) U.S. Coast Pilot or similar publication;(3) Coast Guard Light List;(4) Tide tables; and(5) Current tables, or a river current publication issued by the U.S. Army Corps of Engineers or a river authority. Vessel does not have the required publications for prior operating AOR and not Miami AOR.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2025
Resolved 27 May 2025
Resolution: Correct pubs acquired.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 May 2025 Resolved
Each life jacket, immersion suit, and ring life buoy must be marked in clearly legible block capital letters with the vessel's name. MI identified 19 adult and 12 kid life jackets with improper vessel name marking.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2025
Resolved 27 May 2025
Resolution: Identified life jackets correctly labled.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 19 May 2025 Resolved
The owner, managing operator, or a qualified servicing facility as applicable shall conduct the following inspections and tests:For portable fire extinguishers, the inspections, maintenance procedures and hydrostatic pressure tests required by NFPA 10, (incorporated by reference, see § 114.600 of this chapter) with the frequency specified by NFPA 10. Vessel does not have a log for conducting monthly fire extinguisher checks.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2025
Resolved 27 May 2025
Resolution: Log book created.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 19 May 2025 Resolved
Vessels on rivers route must carry:Three hand orange smoke distress signals approved. Vessel currently has two orange smoke distress signals.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2025
Resolved 27 May 2025
Resolution: Flares acquired.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 19 May 2025 Resolved
The Bridge-to-Bridge Act and the regulations of this part apply to the following vessels in the navigable waters of the United States:vessel of 20 meters or over. Vessel does not have required Bridge-to-Bridge cert.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2025
Resolved 27 May 2025
Resolution: Certificate acquired.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 19 May 2025 Resolved
Portable watertight containers for distress flares and smoke signals shall be of a bright color, and containers shall be clearly marked in legible contrasting letters at least 12.7 millimeters (0.5 inches) high: “DISTRESS SIGNALS”. Flare container not properly labeled.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2025
Resolved 27 May 2025
Resolution: Container properly labled.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 May 2025 Resolved
When a marine employer determines that a casualty or incident is, or is likely to become, a serious marine incident, the marine employer shall take all practicable steps to have each individual engaged or employed on board the vessel who is directly involved in the incident chemically tested for evidence of drug and alcohol use as required in this part. Vessel operator does not have required kits to test for drug/alcohol.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2025
Resolved 27 May 2025
Resolution: DAPI equipment acquired.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 19 May 2025 Resolved
Rails must be permanently installed except that the following rails may be removable:Rails in way of embarkation stations and boarding locations. MI identified on the upper deck multiple rails/gates thats can be opened and allow passengers to fall directly overboard. Gates shall be locked to prevent this action.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2025
Resolved 27 May 2025
Resolution: Gates secured.
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 19 May 2025 Resolved
All persons requiring unescorted access to secure areas of vessels, facilities, and OCS facilities regulated by parts 104, 105 or 106 of this subchapter must possess a TWIC before such access is granted, except as otherwise noted in this section. A TWIC must be obtained via the procedures established by TSA in 49 CFR part 1572. CSO and deck hands do not have required TWIC.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2025
Resolved 30 June 2025
Resolution: Required personnel have obtained TWICs
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 25 March 2025 Resolved
Each vessel must meet the applicable requirements in subchapter S of this Chapter. Vessel removed its paddle wheel and added a stern deck, submit weight changes and any other requirements to the Marine Safety Center (MSC) to determine if the current stability letter is still valid. Prior to carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 May 2025
Resolution: MSC reviewed and approved the process for removing the paddel wheel. MSC has no issues with the minimal amount of weight changes identified. (uploaded MCS approval into docs)
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 25 March 2025 Resolved
A request for an amended Certificate of Inspection must be made to the cognizant OCMI by the owner or managing operator of the vessel at any time there is a change in the character of a vessel or in its route, ownership etc. Vessel has new owner, new name, and is operating in a new OCMI zone. Prior to carrying passengers schedule and receive a new to zone inspection by the local OCMI and provide any and all changes to the vessel that may affect the info on its COI.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 27 May 2025
Resolution: NTZ inspection complete by Sector Miami.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 25 March 2025 No resolution recorded
The owner or managing operator shall submit drawings, sketches, or written specifications describing the details of any proposed alterations to the cognizant [name withheld] and exterior profile drawings must be submitted to MSC for review.
Action required: 16 - Rectify deficiencies w/in 14 days
09 - Working and Living Conditions › 092 - Working Conditions › Steam pipes and pressure pipes
Issued 8 August 2024 Resolved
All piping, valves, and fittings shall be in accordance with good marine practice & suitable for the purpose intended. Support bracket for aft fire main pipe sheered. 46CFR181.15-5(c) Old T
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 August 2024
Resolved 19 August 2024
Resolution: Support Bracket re-welded.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 August 2024 Resolved
Suitable covers, guards or rails should be installed in way of all exposed and hazardous places such as gears, machinery, etc. Port MDE had exposed belt and pulley outside of installed guard. 46CFR177.35-15 Old T
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 August 2024
Resolved 19 August 2024
Resolution: Guard installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 August 2024 Resolved
All Electrical installations shall be to the satisfaction of the officer in charge of Marine Inspections. Dead end wires found in switchboard/electrical closet. 46CFR183.01-15(a) Old T
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 August 2024
Resolved 19 August 2024
Resolution: Wires pulled or dead ended in junction box.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 April 2024 Resolved
The general construction of the vessel must be such as to minimize fire hazards insofar as it is reasonable and practicable. Fuel tank sight glass leaking from lower connection. 46 CFR 116.405 (a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 April 2024
Resolved 9 May 2024
Resolution: CGMI inspected the new sight glass and associated valves installed on the diesel service tank; all sat, no observable leaks detected.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 3 April 2024 Resolved
At each vessel inspection, the marine inspector shall examine applicable spaces to determine that they are in a sanitary condition. Sewage line leaking in engine room. 46 CFR 176.25-45 (a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 April 2024
Resolved 9 May 2024
Resolution: O/O replaced damaged aluminum piping with new PVC piping. All sat; no observed leaks were found when equipment was being operated.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 May 2022 Resolved
Vessel must be fitted with a satisfactory arrangement for draining any watertight compartment. Vessels bilge suction piping for the FWD compartment had a pin hole leak.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2022
Resolved 2 June 2022
Resolution: Conducted def check of the bilge piping system for the foward compartment. Vessel showed proper operation of the bilge pump with no leak.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 31 January 2022 Resolved
A-Class bulkheads or decks must be composed of steel or equivalent material, suitably stiffened and made intact with the main structure of the vessel, such as the shell, structural bulkheads, and decks. They must be so constructed that, if subjected to the standard fire test, they are capable of preventing the passage of smoke and flame for 1 hour. In addition, they must be so insulated with approved structural insulation, bulkhead panels, or deck covering so that, if subjected to the standard fire test for the applicable time period listed below, the average temperature on the unexposed side does not rise more than 139 °C (250 °F) above the original temperature, nor does the temperature at any one point, including any joint, rise more than 181 °C (325 °F) above the original temperature. Engine room STBD side overhead and portside bulkhead had missing pieces of fire protection insulation.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 April 2022
Resolution: Fire protection insulation has been replaced. All sat.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 10 August 2021 Resolved
Found pitting in fore peak during inspection fwd of the collision bulkhead. Pitting measured at 1/4". Must meet ABS aluminum rules per ABS Survey After Construction. Crop and renew to the satisfaction of the Coast Guard at next dry dock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 August 2022
Resolved 28 April 2022
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 July 2019 Resolved
Found upper deck passenger capacity labeled incorrectly at 186 passengers as per stability letter, instead of 172 passengers as per COI.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 August 2019
Resolved 29 July 2019
Resolution: Correctly labeled upper deck passenger limit; 172 permitted as per COI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 July 2019 Resolved
Found broken guard on starboard main diesel engine.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 August 2019
Resolved 29 July 2019
Resolution: Replaced guard with new.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 16 August 2018 Resolved
The vessel is currently broadcasting (1) Improper Call Sign, (2) Zero Length and Beam, (3) Zero Draft.
Condition: Invalid
Action required: 705 - Other - as specified
Due 16 September 2018
Resolved 6 March 2019
Resolution: Owner reported AIS discrepancies corrected. Used NAVCEN to verify accuracy of vessel's AIS broadcast.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 16 July 2018 Resolved
Vessels call sign on FCC Radio Authorization and FCC Safety Radio Telephony Certificate do not match. Correct so call signs match on FCC Documentation.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 August 2018
Resolved 13 August 2018
Resolution: Operator verified vessels call sign to be WDJ5564. All FCC documentation matches.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 July 2018 Resolved
Vessel missing spanner wrenches at fire stations. Provide spanner wrenches at each fire station.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 August 2018
Resolved 13 August 2018
Resolution: Operator provided spanner wrenches at all fire stations.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 16 July 2018 Resolved
Vessel overdue for security audit. Provide proper proof of security audit.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 August 2018
Resolved 13 August 2018
Resolution: Operator provided proper proof of security audit.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 16 July 2018 Resolved
Vessel overdue for security exercise. Provide proper proof of security exercise.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 August 2018
Resolved 13 August 2018
Resolution: Operator provided proper proof of security exercise.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 16 July 2018 Resolved
Vessel's charts are out of date. Provide current charts for operating area.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 August 2018
Resolved 13 August 2018
Resolution: Operator provided current charts.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 16 July 2018 Resolved
Vessel missing light list for operating area. Provide light list for operating area.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 August 2018
Resolved 13 August 2018
Resolution: Operator provided light list for operating area.
Construction/Loadline › Structures › Superstructure
Issued 20 June 2017 Resolved
Complete approved permanent repairs to identified cracking of forward superstructure, port and starboard sides, to satisfaction of an attending Marine Inspector. 46CFR115.700.
Action required: 705 - Other - as specified
Due 26 September 2017
Resolved 21 July 2017
Resolution: Permanent repairs were inspected and approved.
Construction/Loadline › Structures › Superstructure
Issued 12 June 2017 Resolved
Marine inspectors identified cracking on forward superstructure on port and starboard sides. OCMI approved temporary repair method of drill stops to be inspected upon completion. 46CFR115.700.
Action required: 705 - Other - as specified
Due 26 June 2017
Resolved 20 June 2017
Resolution: Approved installed drill stops.
Construction/Loadline › Structures › Superstructure
Issued 12 June 2017 Resolved
Marine inspectors identified four cracks on forward superstructure on port and starboard sides. Upon completion of drill stops, record lengths of all four cracks in a weekly log. Immediately notify marine inspectors if lengths increase. 46CFR115.700(d)
Action required: 705 - Other - as specified
Due 26 September 2017
Resolved 21 July 2017
Resolution: All four cracks were sufficiently filled in and no longer require monitoring.
Construction/Loadline › Structures › Superstructure
Issued 19 May 2017 Resolved
Marine inspectors identified cracking on forward superstructure on port and starboard sides. Provide repair proposal to OCMI. 46CFR115.802(a)(1).
Action required: 705 - Other - as specified
Due 2 June 2017
Resolved 30 May 2017
Resolution: Operator emailed repair proposal for review.
Operations/Management › Drills/Instruction › Fire
Issued 19 May 2017 Resolved
Marine inspectors observed crew members were unable to align fire pump. Provide training and label fire pump alignment valves. 46CFR122.420(a).
Action required: 705 - Other - as specified
Due 2 June 2017
Resolved 30 May 2017
Resolution: Operator emailed updated deckhand formalization sheet, fire pump operating instructions, and painted and labeled the corresponding valve handles.
Engineering › Diesel Engine (propulsion-electric) › Piping (exhaust)
Issued 18 August 2016 Resolved
Starboard engine exhaust busted and lagging damaged. Repair exhaust and replace lagging to the satisfaction of the Coast Guard Marine Inspector. OLD T 46CFR182.20-15
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 September 2016
Resolved 7 September 2016
Resolution: Vessel Representative replaced exhaust and lagging.
Engineering › Bilge Water Management System › Strainer
Issued 18 August 2016 Resolved
Bilge suction not fitted with suitable strainer in the fuel tank compartment. Provide proper strainer to the satisfaction of the Coast Guard Marine Inspector. OLD T 46 CFR 182.25-5(b)
Condition: Invalid
Action required: 705 - Other - as specified
Due 18 September 2016
Resolved 7 September 2016
Resolution: Vessel representative attached proper strainer to bilge suction.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 18 August 2016 Resolved
Raw water Air Conditioning piping is damaged. Repair to the satisfaction of the Coast Guard Marine Inspector. OLD T 46 CFR 182.10-1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 September 2016
Resolved 7 September 2016
Resolution: Vessel representative replaced piping with flexible hose.
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 29 June 2016 Resolved
Vessel has experienced damage to one of her propellers and rudders, as observed by a CG Marine Inspector. The vessel must be drydocked and made available for inspection by CG MI prior to operating. Due Date: PRIOR TO SAILING. Cite: 46CFR115.600(d); 46CFR115.670; 46CFR2.01-10(b).
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 29 June 2016
Resolved 30 June 2016
Resolution: CID granted an allowance for the vessel to operate without having to complete credit drydock, pending the repair and reinstallation of the vessel's propeller and rudder and the completion of an operational test of the vessel; isssued a new no-sail 835.
Engineering › Steering Gear System › Rudder
Issued 29 June 2016 Resolved
Make any propulsion or steering gear that was removed available for inspection by a CG MI, including the damaged propeller and rudder. Due Date: PRIOR TO SAILING. Cite: 46CFR115.670; 46CFR2.01-10(b).
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 29 June 2016
Resolved 1 July 2016
Resolution: [name withheld] inspected repaired propeller and fabrication of new rudder for in-kind replacement; all sat.
Engineering › Steering Gear System › Rudder
Issued 29 June 2016 Resolved
Vessel has experienced damage to one of her propellers and rudders, as observed by a CG Marine Inspector. Complete repairs to propeller & replace rudder to the satisfaction of the attending CG MI, to include an underway operational test. Cites: 46CFR115.600(d); 46CFR115.670. Due date: PRIOR TO SAILING.
Action required: 705 - Other - as specified
Due 1 July 2016
Resolved 2 July 2016
Resolution: [name withheld] received Crofton Diving's report of rudder and propeller reinstallation; all sat. Attended vessel and witnessed operational test of propellers and rudders at pier and underway; all sat. Conducted ISE for damage and water ingress; all sat.
Construction/Loadline › Hull › Bottom Plating
Issued 29 June 2016 Resolved
Due to damage to vessel's running gear from underwater obstruction, vessel's crew must complete & log an internal structure exam of each watertight space on the vessel prior to each trip with passengers, to check for water intrusion. Cites: 46CFR115.670; 46CFR2.01-10(b). Due date: UNTIL NEXT DRYDOCK
Action required: 705 - Other - as specified
Due 30 November 2016
Resolved 14 July 2016
Resolution: Vessel has completed credit drydock.
Engineering › Bilge Water Management System › Piping
Issued 12 August 2015 Resolved
A pinhole was found in the bilge piping branch line in hold #2. Repair to the satisfaction of a marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 August 2015
Resolution: A two-foot section of piping was installed on the suction piping to repair the pin hole leak.
Fire Fighting › Ventilation Systems › Ducts
Issued 12 August 2015 Resolved
Ventilation to the engine room space cannot be properly secured. Ensure vents can be properly closed.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 August 2015
Resolution: Observed proper closure of vents over ducting that leads to the engine space.
Engineering › Bilge Water Management System › Piping
Issued 16 August 2011 Resolved
Prior to carrying passengers reweld bilge piping as marked in 3rd void.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 September 2011
Resolved 24 August 2011
Resolution: Vessel rewelded bilge piping and tested satisfactorily.
Engineering › Bilge Water Management System › Valve
Issued 16 August 2011 Resolved
Prior to carrying passengers replace/renew check values in Machinery and 3rd forward compartment.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 September 2011
Resolved 24 August 2011
Resolution: Vessel renewed check valves in machinery and 3rd forward compartment and tested satisfactorily.
Electrical › Electrical Distribution System (service) › Wiring
Issued 16 August 2011 Resolved
Remove/Correct dead end wires in 3rd void within 14 days.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 August 2011
Resolved 24 August 2011
Resolution: Vessel placed dead end wires in junction box.
Engineering › Bilge Water Management System › Pump
Issued 16 August 2011 Resolved
Prior to carrying passengers prove proper operation of engine driven bilge pump.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 September 2011
Resolved 24 August 2011
Resolution: Vessel proved proper operation of engine driven bilge pump.
Engineering › Steering Gear System › Rudder
Issued 16 August 2011 Resolved
Prior to carrying passengers reweld starboard rudder post support as marked.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 September 2011
Resolved 24 August 2011
Resolution: Vessel rewelded stbd rudder post support.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 21 July 2009 Resolved
Provide alcohol test devices onboard vessel. Current stock is expired.
Action required: 705 - Other - as specified
Due 28 July 2009
Resolved 5 August 2009
Resolution: Received invoice from Harbor Tours verifying the purchase of the alcohol test devices.
Operations/Management › Passenger Operations › Safety Orientation
Issued 13 August 2008 Resolved
Mark upper deck with maximum number of passengers per stability letter.
Action required: 705 - Other - as specified
Due 13 September 2008
Resolved 2 September 2008
Resolution: Maximum passengers on upper deck marked iaw vessel stability letter.
Engineering › Bilge Water Management System › Pump
Issued 13 August 2008 Resolved
Provide visual indication for automatic bilge pump.
Action required: 705 - Other - as specified
Due 13 September 2008
Resolved 2 September 2008
Resolution: Automatic bilge pump switch removed. Manual bilge pump capability only in engine room.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 13 August 2008 Resolved
Provide flame shield at emergency shut off valve.
Action required: 705 - Other - as specified
Due 13 September 2008
Resolved 2 September 2008
Resolution: Installed aluminum shield around emergency shut off valves.
Engineering › Steering Gear System › Fastener
Issued 18 October 2006 Resolved
Prior to a credit dry dock exam, replace all support brackets for paddle wheel shaft supports. All the sheaves are cracked.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 October 2006
Resolved 9 May 2007
Resolution: All shaft supports and brackets have been replaced with new.
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 18 October 2006 Resolved
Prior to a credit dry dock examination, paint draft marks contrasting colors from hull color.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 October 2006
Resolved 9 May 2007
Resolution: Draft marks painted on hull.
Construction/Loadline › Hull › Bottom Plating
Issued 18 October 2006 Resolved
Prior to a credit dry dock examination, crop and renew wasted aluminum in the forward section, bottom, of the fuel oil tank. When tank was open in FL, found several deep pits. Yard temporarily clad welded pits until vessel returns to a yard for work.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 October 2006
Resolved 9 May 2007
Resolution: Bottoms of all tanks replaced with new hull plating.
Stability › Watertight Integrity › General
Issued 18 October 2006 Resolved
Prior to a credit dry dock examination, make bow void deck hatch water tight. Hatch locking dogs were frozen in the open position.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 October 2006
Resolved 9 May 2007
Resolution: Hatch locking dogs freed up and captive chain installed.
Engineering › Sea-water System (primary cooling) › Sea Chest
Issued 18 October 2006 Resolved
Prior to a credit dry dock examination, repair or replace the STBD generator sea strainer. Strainer shows signs of savvier salt water leakage.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 October 2006
Resolved 9 May 2007
Resolution: Stbd generator sea strainer replaced with new.
Engineering › Sea-water System (primary cooling) › Piping
Issued 18 October 2006 Resolved
Prior to a credit dry dock examination, replace both raw water OVBD DISCH fittings on PORT and STBD generator to a metallic fitting. They have installed PVC through hull fittings.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 October 2006
Resolved 9 May 2007
Resolution: Metal thru hull fittings installed to the port and stbd overboard discharges.
Engineering › Bilge Water Management System › Piping
Issued 18 October 2006 Resolved
Prior to a credit dry dock examination, remove temporary soft pipe couplers and hard pipe as discussed, just FWD of the bilge piping manifold in engine room. Instead of replacing couplers with couplers, they slipped on a temp union that is not authorized.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 October 2006
Resolved 9 May 2007
Resolution: Temporary couplers and unions removed and replaced with new pipe.
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 18 October 2006 Resolved
Prior to a credit dry dock examination, repair sewage pipe leak on 4 inch "T" in engine room over fire pump.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 October 2006
Resolved 9 May 2007
Resolution: Sewage pipe cropped and renewed with new pipe.
Construction/Loadline › Hull › Bottom Plating
Issued 18 October 2006 Resolved
Prior to a credit dry dock examination, crop and renew all wasted aluminum, back to good aluminum in way of the FWD engine room bilges. Two holes were clad welded and a doubler placed underneath, along with the worst pits for transit to next dry dock. Pitted area is generally located in the FWD section of the engine room bilge along the FWD BLKHD. The center is the worst.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 October 2006
Resolved 9 May 2007
Resolution: Forward engine room hull plating replaced with new.
Construction/Loadline › Hull › Bottom Plating
Issued 18 October 2006 Resolved
Prior to a credit dry dock examination, crop and renew all wasted aluminum in the bottom of the sewage tank. Clad welded several pits for transit to next dry dock.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 October 2006
Resolved 9 May 2007
Resolution: Bottom of sewage tank replaced with new plating.
Construction/Loadline › Structures › Trunk
Issued 18 October 2006 Resolved
Prior to a credit dry dock examination, crop and renew back to good aluminum, FWD water tank wall. Wall has been clad welded several times to a point that the FWD tank wall looks like swiss cheese, and soon will rupture filling the void.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 October 2006
Resolved 9 May 2007
Resolution: Forward water tank bulkhead replaced from hull plate to 3'' mark.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 30 January 2006 Resolved
Provide chemical testing random program proof of annual contract for four expired employees per 46CFR230.
Condition: Improper/Lack of Maintenance
Due 8 February 2006
Resolved 16 February 2006
Resolution: POC PROVIDED PROOF.
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 30 January 2006 Resolved
Provide copy of 2004 chemical testing management information system (MIS) from consortium or consortium letter per 46CFR16.500.
Condition: Improper/Lack of Maintenance
Due 8 February 2006
Resolved 16 February 2006
Resolution: Provided letter.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 30 January 2006 Resolved
Provide documentation of required training per 46CFR16.401(b) for all crew and supervisory personnel.
Condition: Improper/Lack of Maintenance
Due 8 February 2006
Resolved 16 February 2006
Resolution: Provided training video and logged that they reviewed tape.
Fire Fighting › Portable CO2 Fire Extinguisher › Condition
Issued 30 January 2006 Resolved
Provide annual portable fire extinguisher servicing prior to the carriage of passengers for hire and provide this office proof of servicing per 46CFR115.810(b).
Condition: Improper/Lack of Maintenance
Due 31 January 2006
Resolved 16 February 2006
Resolution: Extinguisher inspection was being conducted while on board for deficiency follow-up.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 30 January 2006 Resolved
Provide log entry for "GENERAL DESCRIPTION" of all emergency drills as required by 46CFR122.520 & .524.
Condition: Improper/Lack of Maintenance
Due 28 February 2006
Resolved 16 February 2006
Resolution: Drills entered into log with more detail.
Engineering › Bilge Water Management System › Hose
Issued 30 January 2006 Resolved
Renew bilge pump discharge hose with accepted (SAE J-1942) hose from PORT engine Jabsco pump discharge where split per 46CFR56.59-25(b).
Condition: Improper/Lack of Maintenance
Due 30 January 2006
Resolved 16 February 2006
Resolution: Inspected new hose and tested system, SAT.
Operations/Management › Pollution › Control of Discharge of Oil
Issued 30 January 2006 Resolved
Provide an oil plooution discharge placard in a conspicuous place in the machinery space, or at the bilge pump control station per 33CFR155.450.
Condition: Improper/Lack of Maintenance
Due 30 January 2006
Resolved 16 February 2006
Resolution: Placards posted.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 30 January 2006 Resolved
Provide CG approved A-60 Structural Fire Protection insulation where missing or wrong type on overhead of the machinery space as specified by vessels CG approved SFP Plans and per 46CFR116.415.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 May 2007
Resolution: Missing and wrong type insulation replaced with CG approved insulation.
Electrical › Electric Supply System (service) › Battery Installation
Issued 30 January 2006 Resolved
Provide permanent type connectors on batteries per 46CFR122.350(d).
Condition: Improper/Lack of Maintenance
Due 28 February 2006
Resolved 16 February 2006
Resolution: Corrected
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 30 January 2006 Resolved
Clean machinery space hull at FWD BLKHD where corrosion and debris has collected and present to a CG inspector for further examination.
Condition: Improper/Lack of Maintenance
Due 28 February 2006
Resolved 16 February 2006
Resolution: Cleaned.
Electrical › Electric Generation Source (service) › Circuit Breaker
Issued 30 January 2006 Resolved
Label generator switches.
Condition: Improper/Lack of Maintenance
Due 28 February 2006
Resolved 16 February 2006
Resolution: labeled
Engineering › Sea-water System (primary cooling) › Piping
Issued 30 January 2006 Resolved
PRIOR TO NEXT CREDIT DRY DOCK, renew sea suction non-metallic hose located forward of the PORT MDE with CG accepted SAE J-1942 hose per 46CFR 56.59-25(b).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 9 May 2007
Resolution: Replaced non-metallic hose with approved hose.
Construction/Loadline › Penetrations › Weld
Issued 30 January 2006 Resolved
PRIOR TO NEXT CREDIT DRY DOCK, provide welded metallic pipe and deck penetrations from men's head PORT side OVHD of machinery space per guidance in NVIC 9-97 figure 3.6(f).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 9 May 2007
Resolution: PVC pipe removed and replaced with aluminum pipe per original drawings.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 30 January 2006 Resolved
Remove excess combustible (cardboard) STBD side FWD in enginroom.
Condition: Improper/Lack of Maintenance
Due 30 January 2006
Resolved 16 February 2006
Resolution: Cleared.
Fire Fighting › Structural - A Class Divisions › Accommodation Spaces
Issued 30 January 2006 Resolved
Provide CG approved A-Class SFP insulation per approved CG SFP Plan where missing or incorrect type in fuel tank void per 46CFR116.415.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 9 May 2007
Resolution: Installed missing insulation in fuel tank void.
Accommodation/Occupational Safety › Other Accommodation Spaces › Recreation Space
Issued 30 January 2006 Resolved
[name withheld] stairwell and FWD main deck doors on the interiors with signs per 46CFR122.606 "EMERGENCY EXIT, KEEP CLEAR".
Condition: Improper/Lack of Maintenance
Due 28 February 2006
Resolved 16 February 2006
Resolution: Signs posted
Fire Fighting › Fire Main › Condition
Issued 30 January 2006 Resolved
Make permanent repairs to fire main piping main deck PORT side midships where holed. Demonstrate repairs to the satisfaction of a CG Marine Inspector
Condition: Improper/Lack of Maintenance
Due 30 January 2006
Resolved 16 February 2006
Resolution: CLEARED, BUT FOUND NEW HOLES, SEE #27 & 28
Fire Fighting › Structural - A Class Divisions › Accommodation Spaces
Issued 30 January 2006 Resolved
Provide CG approved A-Class SFP insulation per approved CG SFP Plan replacing in kind (A-60) where missing or falling from OVHD in main deck per 46CFR116.415 and NVIC 9-97 figures 3.3.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 May 2007
Resolution: Installed missing insulation in overhead on main deck.
Electrical › Lighting (service) › Outlet Box
Issued 30 January 2006 Resolved
Mount electrical box in OVHD, provide pressure fittings on wires, and provide cover for box above pantry STBD side AFT area. Provide pressure fittings on wires in second box in OVHD AFT PORT side in OVHD.
Condition: Improper/Lack of Maintenance
Due 28 February 2006
Resolved 16 February 2006
Resolution: Corrected.
Electrical › Lighting (service) › Outlet Box
Issued 30 January 2006 Resolved
Provide GFI recepticale in series for wet area in bar PORT side AFT main deck.
Condition: Improper/Lack of Maintenance
Due 30 January 2006
Resolved 16 February 2006
Resolution: Corrected
Electrical › Electric Supply System (service) › Cable
Issued 30 January 2006 Resolved
Remove extension cord for power in bar area AFT of wheelhouse and in OVHD of main deck ceiling.
Condition: Improper Installation
Due 30 January 2006
Resolved 16 February 2006
Resolution: Removed.
Construction/Loadline › Penetrations › Pipe Flange
Issued 30 January 2006 Resolved
PRIOR TO NEXT CREDIT DRY DOCK, provide metallic piping for length of PVC pipe in main deck OVHD where A-Class insulation is identified by SFP approved plan per 46CFR116.415 and described in NVIC 9-97.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 9 May 2007
Resolution: PVC drain line in overhead replaced with metallic pipe.
Accommodation/Occupational Safety › Other Accommodation Spaces › Recreation Space
Issued 30 January 2006 Resolved
Remove excessive combustibles (wood) from the AFT end of main deck OVHDS.
Condition: Improper/Lack of Maintenance
Due 30 January 2006
Resolved 16 February 2006
Resolution: Wood removed.
Construction/Loadline › Structures › End Bulkhead
Issued 30 January 2006 Resolved
PRIOR TO NEXT CREDIT DRY DOCK, provide metal closure of space between both heads and passenger compartment in the main deck OVHD.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 9 May 2007
Resolution: Metal panel installed over bulkhead opening in heads.
Fire Fighting › Fire Main › Condition
Issued 30 January 2006 Resolved
Make temp repairs to the 3 plugged areas on fire main IWO main deck, as discussed. Prior to repair, provide information (spec sheet) for your aluminum or galvanized coupler used. While inspecting deficiency #19, noted three other areas in fire main that were plugged and sealed with improper repairs.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 February 2006
Resolved 9 May 2006
Resolution: Rcv''d info for temp patches to be used - sat.
Fire Fighting › Fire Main › Condition
Issued 30 January 2006 Resolved
PRIOR TO NEXT CREDIT DRY DOCK, crop and renew all wasted fire main piping throughout vessel IAW 46CFR119.710.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 9 May 2007
Resolution: Entire fire main piping system replaced with new per original drawings.
Electrical › Electrical Distribution System (service)
Issued 9 January 2004 Resolved
INSTALL WET LOCATION OUTLET COVERS IN WAY OF UPPER BAR SINK AND SNACK BAR SINK. LEGACY COMPONENT DESC: Outlet Box
Due 9 February 2004
Resolved 9 February 2004
Communications › Radio Communications
Issued 9 January 2004 Resolved
UPDATE FCC RADIOTELEPHONE SAFETY CERTIFICATE. LEGACY COMPONENT DESC: VFH Radiotelephone
Due 9 February 2004
Resolved 14 January 2004
Resolution: FAX DOCUMENTATION.
Engineering › Bilge Water Management System › Piping
Issued 9 January 2003 Resolved
MAKE PERMANENT REPAIR TO SPLICE IN BILGE PIPING IN FUEL TANKS SPACE PRIOR TO COMPLETION OF NEXT DRYDOCK. LEGACY COMPONENT DESC: Piping
Condition: Improper Installation
Due 1 September 2004
Resolved 26 October 2004
Engineering › Bilge Water Management System
Issued 20 August 2002 Resolved
PROPERLY LABEL BILGE MANIFOLD SYSTEM.
Condition: Unknown
Due 20 September 2002
Resolved 3 September 2002
Resolution: SAT. CLEARD BY [name withheld].
Engineering › Freshwater System (jacketwater cooling) › Fitting
Issued 20 August 2002 Resolved
REPAIR LEAKS IN KEEL COOLER FITTINGS IN ENGINE ROOM.
Condition: Unknown
Due 6 September 2002
Resolved 3 September 2002
Resolution: SAT. CLEARED BY [name withheld].
Lifesaving
Issued 26 October 2001 Resolved
INITIATE LIFESAVING EQUIPMENT MAINTENANCE RECORDS IAW MANUFACTURER INSTRUCTIONS.
Condition: Unknown
Due 20 January 2002
Resolved 9 January 2003
Resolution: ONBOARD AND MAINTAINED.
Fire Fighting
Issued 26 October 2001 Resolved
PROVIDE FIRE CONTROL PLAN AND POST IAW 46 CFR 116.530.
Condition: Unknown
Due 9 July 2003
Resolved 9 January 2004
Resolution: WITNESSED AND POSTED.
Lifesaving
Issued 26 October 2001 Resolved
PROVIDE EMERGENCY EVACUATION PLAN AND TRAINING PAMPHLET IAW 46 CFR 116.520.
Condition: Unknown
Due 9 July 2003
Resolved 9 January 2004
Resolution: ENCLOSED.
Fire Fighting
Issued 26 October 2001 Resolved
REPAIR ALL STRUCTURAL FIRE PROTECTION INSULATION IAW APPROVED PLANS.
Condition: Unknown
Due 20 December 2001
Resolved 20 December 2001
Resolution: REPAIRED AND INSPECTED.
Construction/Loadline
Issued 26 October 2001 Resolved
INSTALL POSITIVE CLOSURE DEVICE ON AFT SUBMERSIBLE PUMP THROUGH HULL. INSTALL METALLIC OR EQUIVALENT HULL STRENGTH THROUGH HULL ON THE SAME.
Condition: Unknown
Due 26 November 2001
Resolved 20 December 2001
Resolution: REPAIRED AND INSPECTED.
Engineering
Issued 26 October 2001 Resolved
INSTALL FLAME SCREENS ON SEWAGE VENT.
Condition: Unknown
Due 6 November 2001
Resolved 6 November 2001
Construction/Loadline
Issued 26 October 2001 Resolved
INSTALL BUG SCREENS ON POTABLE WATER VENT PIPING.
Condition: Unknown
Due 26 November 2001
Resolved 20 December 2001
Resolution: REPAIRED AND INSPECTED.
Electrical
Issued 26 October 2001 Resolved
REMOVE POWER STRIP FROM COMPARTMENT FROM BEHIND PILOT HOUSE OR INSTALL HARDWIRED RECEPTACLES IF NEEDED.
Condition: Unknown
Due 26 November 2001
Resolved 20 December 2001
Resolution: REPAIRED AND INSPECTED.
Construction/Loadline
Issued 26 October 2001 Resolved
REPAIR BILGE SUCTION LINE IN VOID AFT OF COLLISION BULKHEAD PRIOR TO CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 6 November 2001
Resolved 6 November 2001
Lifesaving
Issued 26 October 2001 Resolved
INSTALL RESCUE PLATFORM TO ASSIST IN RETRIEVAL OF HELPLESS PERSON FROM THE WATER.
Condition: Unknown
Due 26 November 2001
Resolved 20 December 2001
Resolution: WITNESSED USE OF PLATFORM.
Lifesaving
Issued 26 October 2001 Resolved
POST STATION BILL IAW 46CFR122.514.
Condition: Unknown
Due 26 November 2001
Resolved 20 December 2001
Resolution: WITNESSED.
Documentation
Issued 26 October 2001 Resolved
PROVIDE UPDATED CHEMICAL TESTING PROGRAM (CREW LIST AND MIS REPORT) FROM CONSORTIUM.
Condition: Unknown
Due 26 November 2001
Resolved 20 December 2001
Resolution: WITNESSED.
Fire Fighting
Issued 26 October 2001 Resolved
INSTALL FIRE RETARDENT TRASH RECEPTACLES.
Condition: Unknown
Due 26 November 2001
Resolved 20 December 2001
Resolution: WITNESSED.
Electrical
Issued 26 October 2001 Resolved
REPLACE ALL WIRE NUTS WITH COMPRESSION FITTINGS.
Condition: Unknown
Due 26 November 2001
Resolved 20 December 2001
Resolution: WITNESSED.
Lifesaving
Issued 22 January 2001 Resolved
UPDATE CREW EMERGENCY PROCEDURES TO MEET PROPER MAN-OVERBOARD OPERATIONS.
Condition: Unknown
Due 22 January 2001
Resolved 14 June 2001
Fire Fighting
Issued 22 January 2001 Resolved
PROVIDE FIRE INSTALLATION IN #4 HOLD WERE MISSING.
Condition: Unknown
Due 22 January 2001
Resolved 14 June 2001
Lifesaving
Issued 22 January 2001 Resolved
PROVIDE PROOF THAT CREW IS ENROLLED IN APPROVED DRUG PROGRAM.
Condition: Unknown
Due 14 July 2001
Resolved 25 October 2001
Construction/Loadline
Issued 6 September 2000 Resolved
INSTALL VALVES ON KEEL COOLER SUPPLY AND DISCHARGE LINES IN ACCORDANCE WITHSUBCHAPTER F OLD T REGS AND/OR SUBCHAPTER T NEW REGS 46CFR182.422
Condition: Unknown
Due 6 September 2000
Resolved 6 September 2000
Lifesaving
Issued 24 November 1997 Resolved
REPLACE EXISTING RETROREFLECTIVE TAPE ON ALL LIFEFLOATS INCLUDING REPLACE SEA PAINTER.
Condition: Unknown
Due 15 January 1998
Resolved 15 January 1998
Engineering
Issued 24 November 1997 Resolved
LABEL ALL FUEL SHUT-OFF LOCATIONS.
Condition: Unknown
Due 15 January 1998
Resolved 15 January 1998
Lifesaving
Issued 24 November 1997 Resolved
PROVIDE RESCUE BOAT OR PROVE THAT VSL IS CAPABLE OF RETRIEVING A MAN OVERBOARD IN PRESENCE OF USCG INSPECTORS.
Condition: Unknown
Due 15 January 1998
Resolved 15 January 1998
Documentation
Issued 24 November 1997 Resolved
PROVIDE EMERGENCY BROADCAST PLACARD FOR BRIDGE.
Condition: Unknown
Due 15 January 1998
Resolved 15 January 1998
Documentation
Issued 24 November 1997 Resolved
PROVIDING LOG FOR CREW TRAINING.
Condition: Unknown
Due 15 January 1998
Resolved 15 January 1998
Lifesaving
Issued 24 November 1997 Resolved
UPGRADE OR REPLACE EXISTING FIRST AID KIT.
Condition: Unknown
Due 15 January 1998
Resolved 15 January 1998
Lifesaving
Issued 24 November 1997 Resolved
REPLACE EXISTING FOUR (4) LIFEBUOYS WITH CG APPROVED LIFERINGS > 24" APPROVED FOR VSLS > 65 FEET IN LENGTH. ENSURE PROPER RETROREFLECTIVE TAPE IS ATTACHED TO THESE LIFEBUOYS.
Condition: Unknown
Due 15 January 1998
Resolved 15 January 1998
Lifesaving
Issued 12 November 1996 Resolved
REPAINT/RELABEL LIFEFLOATS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 November 1996
Resolved 12 November 1996
Lifesaving
Issued 12 November 1996 Resolved
RELABEL RING BUOYS WITH VESSEL NAME._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 12 November 1996
Resolved 12 November 1996
Electrical
Issued 12 November 1996 Resolved
REPAIR/RENEW EMERGENCY LIGHT 2ND DECK AFT OF WHEELHOUSE.
Condition: Unknown
Due 12 November 1996
Resolved 12 November 1996
Fire Fighting
Issued 13 November 1995 Resolved
INSTALL MISSING PIECE OF INSULATION IN FUEL TANK COMPARTMENT._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 November 1995
Resolved 13 November 1995
Navigation
Issued 13 November 1995 Resolved
PROVIDE CURRENT COPIES OF LIGHT LIST, COAST PILOT AND 46CFR PARTS 166 - 199.
Condition: Unknown
Due 13 November 1995
Resolved 13 November 1995
Electrical
Issued 13 November 1995 Resolved
INSTALL COVERS ON FOUR BATTERY BOXES.
Condition: Unknown
Due 13 November 1995
Resolved 13 November 1995
Fire Fighting
Issued 10 January 1995 Resolved
Replace missing insulation in fuel tank compartment.
Condition: Unknown
Due 10 January 1995
Resolved 10 January 1995
Fire Fighting
Issued 10 January 1995 Resolved
Replace missing insulation in engine room.
Condition: Unknown
Due 10 January 1995
Resolved 10 January 1995
Engineering
Issued 10 January 1995 Resolved
Provide and install guards in starbord generator and both main engines.
Condition: Unknown
Due 10 January 1995
Resolved 10 January 1995
Construction/Loadline
Issued 15 November 1994 Resolved
Free-up and prove operation of bilge line check valve to forepeak.
Condition: Unknown
Due 15 November 1994
Resolved 15 November 1994
Electrical
Issued 15 November 1994 Resolved
Provide/install rubber matting in front of generator switchboard.
Condition: Unknown
Due 15 November 1994
Resolved 15 November 1994
Navigation
Issued 29 December 1992 Resolved
Tighten leaking hydraulic fitting on stbd ram steering.
Condition: Unknown
Due 2 February 1993
Resolved 2 February 1993
Electrical
Issued 29 December 1992 Resolved
Repair emergency light main deck port side forward.
Condition: Unknown
Due 2 February 1993
Resolved 2 February 1993
Electrical
Issued 29 December 1992 Resolved
Provide wiring diagram for newly installed 50 KW generator.
Condition: Unknown
Due 2 February 1993
Resolved 2 February 1993
Electrical
Issued 29 December 1992 Resolved
Complete installation of voltmeter, ammeter and frequency meter for new 50 KW generator.
Condition: Unknown
Due 2 February 1993
Resolved 2 February 1993
Construction/Loadline
Issued 29 December 1992 Resolved
Rewire bilge alarm in engineroom using junction box and proper type cable.
Condition: Unknown
Due 2 February 1993
Resolved 2 February 1993
Electrical
Issued 4 September 1991 Resolved
PROVIDE BILGE STRAINER FOR BILGE LINE IN FUEL/HOLDING COMPARTMENT. MUST BECOMPLETED TO THE SATISFACTION OF ATTENDING USCG MARINE INSPECTOR.
Condition: Unknown
Due 4 September 1991
Resolved 4 September 1991
Construction/Loadline
Issued 4 September 1991 Resolved
LABEL 3 ELECTRICAL BOXES IN ENGINE ROOM TO SHOW WHAT EACH SERVICES. MUST BE COMPLETED TO THE SATISFACTION OF ATTENDING USCG MARINE INSPECTOR.
Condition: Unknown
Due 4 September 1991
Resolved 4 September 1991
Deck/Cargo
Issued 4 January 1991 Resolved
REPLACE MAIN PAINTER MIN 3000 PSI BREAK STRENGTH.
Condition: Unknown
Due 4 January 1991
Resolved 4 January 1991
Deck/Cargo
Issued 4 January 1991 Resolved
REPAIR FOREPEAK BILGE SUCTION.
Condition: Unknown
Due 4 January 1991
Resolved 4 January 1991
Lifesaving
Issued 4 January 1991 Resolved
RENEW ALL 3 R/B GRAB LINES.
Condition: Unknown
Due 4 January 1991
Resolved 4 January 1991
Electrical
Issued 4 January 1991 Resolved
REWIRE AFT MAIN DECK EMERGENCY LT.
Condition: Unknown
Due 4 January 1991
Resolved 4 January 1991
Electrical
Issued 4 January 1991 Resolved
PROPERLY SPLICE WIRING AND HANG PIPING FOR NEW A/C UNIT IN ER.
Condition: Unknown
Due 4 January 1991
Resolved 4 January 1991
Navigation
Issued 23 June 1990 Resolved
RENEW P & S RUDDER RAM END LINKS
Condition: Unknown
Due 23 June 1990
Resolved 23 June 1990
Construction/Loadline
Issued 23 June 1990 Resolved
CREDIT DRYDOCK DUE 23DEC91. CONTACT USCG PRIOR TO THIS DATE TO SCHEDULE THIS INSPECTION.
Condition: Unknown
Due 23 June 1990
Resolved 23 June 1990
Electrical
Issued 6 February 1990 Resolved
PROVIDE GENERATOR AMP METER WHICH CAN MONITOR MAIN GENERATOR.
Condition: Unknown
Due 6 February 1990
Resolved 6 February 1990
Electrical
Issued 5 January 1990 Resolved
REMOVE EXTENSION CORDS, BAR LTS, AND 6 STRIP PLUG IN PORT BAR. HARDWIRE OUTLETS IAW 46 CFR 183.
Condition: Unknown
Due 5 January 1990
Resolved 5 January 1990
Lifesaving
Issued 5 January 1990 Resolved
SEPARATE LIFEFLOATS, WHICH ARE STACKED WITH SPACERS IAW 180.20-1(A)(F). TO BE COMPLETED PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 5 January 1990
Resolved 5 January 1990
Lifesaving
Issued 5 January 1990 Resolved
REPLACE THE LINES TO THE LIFEFLOAT WATERLIGHTS WITH 18' LINES. TO BE COMPLETED PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 5 January 1990
Resolved 5 January 1990
Construction/Loadline
Issued 5 January 1990 Resolved
SUPPLY AND INSTALL A CAPTIVE CHAIN FOR THE FWD HATCH.
Condition: Unknown
Due 5 January 1990
Resolved 5 January 1990
Electrical
Issued 5 January 1990 Resolved
HARDWIRE IAW 46 CFR 183 RECEPTACLES FOR COFFEE MAKER IN STBD BAR. REMOVE EXTENSION CORDS.
Condition: Unknown
Due 5 January 1990
Resolved 5 January 1990
Engineering
Issued 5 January 1990 Resolved
MAKE AIR RECEIVER READY FOR INTERNAL INSPECTION.
Condition: Unknown
Due 5 January 1990
Resolved 5 January 1990
Engineering
Issued 5 January 1990 Resolved
MAKE THE REMOTE FUEL SHUTOFFS OPERABLE FROM OUTSIDE THE TANK COMPARTMENT IAW 46 CFR 182.20-40(B)(3) BY NEXT DRYDOCK BUT NO LATER THAN 13DEC90.
Condition: Unknown
Due 5 January 1990
Resolved 5 January 1990
Construction/Loadline
Issued 5 January 1990 Resolved
REWELD FRACTURED WELD IN 2ND FRAME AFTER COLLISION BULKHEAD ON SIDE LONG (PORT SIDE) PRIOR TO NEXT DRYDOCK BUT NO LATER THAN 13DEC90.
Condition: Unknown
Due 5 January 1990
Resolved 5 January 1990
Electrical
Issued 5 January 1990 Resolved
REMOVE EXTENSION CORD AND HARDWIRE RECEPTACLE FOR BLENDER IN UPPER BAR. REMOVE BAR LTS, AND REPLACE WITH UL LISTED LIGHTS.
Condition: Unknown
Due 5 January 1990
Resolved 5 January 1990
Electrical
Issued 5 January 1990 Resolved
REMOVE EXTENSION CORDS FOR DECORATIVE LIGHTS AND HARDWIRE IAW 46 CFR 183.
Condition: Unknown
Due 5 January 1990
Resolved 5 January 1990
Electrical
Issued 5 January 1990 Resolved
REMOVE 6 TERMINAL LIGHTS AND FLOOD LIGHTS IN ER AND IF DESIRED, HARDWIRE INUL APPROVED LIGHTS.
Condition: Unknown
Due 5 January 1990
Resolved 5 January 1990
Engineering
Issued 5 January 1990 Resolved
REMOVE PORTABLE AIR COMPRESSOR OR PERMANENTLY INSTALL (MOUNTED AND HARDPIPED).
Condition: Unknown
Due 5 January 1990
Resolved 5 January 1990
Fire Fighting
Issued 5 January 1990 Resolved
PROVIDE APPROVED MARINE BRACKETS FOR ALL FIRE EXTINGUISHERS.
Condition: Unknown
Due 5 January 1990
Resolved 5 January 1990
Navigation
Issued 5 January 1990 Resolved
PROVIDE AN ALL AROUND WHITE LIGHT TO MEET INLAND RULE 30 OF THE NAVIGATION RULES.
Condition: Unknown
Due 5 January 1990
Resolved 5 January 1990
Lifesaving
Issued 5 January 1990 Resolved
RE-TIE LIFEFLOATS TO THE PAINTER IAW 46 CFR 180.20-1(A)(5). COIL PAINTER SO THAT IT WILL RUN OUT FREELY. TO BE COMPLETED PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 5 January 1990
Resolved 5 January 1990
Deck/Cargo
Issued 2 August 1989 Resolved
FWD MASTHEAD IS TO BE MADE TO COMPLY WITH COLREGS 19.7' ABOVE HULL OR NOT LESS THAN BREATH OF VESSEL.
Condition: Unknown
Due 2 August 1989
Resolved 2 August 1989
Fire Fighting
Issued 2 August 1989 Resolved
REPLACE ALL FIRE HOSE WITH ALUMINUM COUPLINGS.
Condition: Unknown
Due 2 August 1989
Resolved 2 August 1989
Fire Fighting
Issued 2 August 1989 Resolved
PROVIDE A SUPPORT FOR FIRE MAIN PORT SIDE MAIN DECK.
Condition: Unknown
Due 2 August 1989
Resolved 2 August 1989
Electrical
Issued 13 June 1989 Resolved
WELD GENERATOR SEA SUCTION FITTING TO HULL AND REMOVE BOLTED WOOD BLOCK AT NEXT SCHEDULED DRYDOCK.
Condition: Unknown
Due 13 June 1989
Resolved 13 June 1989
Documentation
Issued 13 June 1989 Resolved
DRYDOCK DUE 13DEC90. CONTACT USCG PRIOR TO THIS DATE TO SCHEDULE THIS INSPECTION.
Condition: Unknown
Due 13 June 1989
Resolved 13 June 1989
Fire Fighting
Issued 5 January 1989 Resolved
MAKE PERMANENT REPAIRS TO HOLED PIPE IN WAY OF PORT FWD FIRE STATION PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 5 January 1989
Resolved 5 January 1989
Electrical
Issued 5 January 1989 Resolved
INSTALL GUARDS ON BOTH GENERATORS IN WAY OF FLYWHEELS.
Condition: Unknown
Due 5 January 1989
Resolved 5 January 1989
Deck/Cargo
Issued 5 January 1989 Resolved
INSTALL FLAME SCREEN OF 30X30 MESH PER INCH OF CORROSION RESISTANT METAL FOR FUEL OIL TANK VENT.
Condition: Unknown
Due 5 January 1989
Resolved 5 January 1989
Documentation
Issued 5 January 1989 Resolved
PROVIDE COPY OF FCC SAFETY CERTIFICATE.
Condition: Unknown
Due 5 January 1989
Resolved 5 January 1989
Fire Fighting
Issued 5 January 1989 Resolved
REMOVE PVC PIPE & REPLACE WITH METAL FOR FIRE STATION OUTSIDE ENGINE ROOM.
Condition: Unknown
Due 5 January 1989
Resolved 5 January 1989

Casualty record · 2

29 June 2016Routine · role: Involved in a Marine Casualty · activity 5938514
23 May 2026Routine · role: Involved in a Marine Casualty · activity 8379630
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

CARRIE B (2016). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.