MAURY USCG vessel records
← All vessels

JAMES JOSEPH II

JAMES JOSEPH II is a 1978 passenger vessel (inspected). The Coast Guard has recorded 23 inspections since 2016, most recently in April 2026, along with 41 deficiencies and 1 casualty investigation in 1998.

Records from 1998 to 2026. Most recent: inspection, 13 April 2026.

Built
1978
Last inspected
13 April 2026
Documentation
Expired · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the tow units, the casualty record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 13 April 2026
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WCX6622
228705
Flag
UNITED STATES
Maury page id
psix-228705

Documentation record

Registered dimensions (L × B × D)60.9 ft × 21.8 ft × 6.4 ft
Registered tonnagegross 80 / net 60
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderYANK BOAT WORKS · TUCKAHOE NJ, UNITED STATES · built 1978
Hull materialWood
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW YORK, NY
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it60 - Regulatory (Subpart C or D), Net Ton
80 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

23 inspections, each with its date, unit and type; 41 deficiencies with the resolution recorded against each; 1 vessel inspected with it, by name and date; 1 casualty investigation, with date and classification; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

NY 7594MP Passenger (Uninspected) · MISLE 1667581 · 26 April 2021 · activity 7206688

Inspection history · 23

13 April 2026 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8347245
3 March 2026 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8319296
2 March 2026 Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8318427
20 March 2025 Annual Inspection · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8096687
1 April 2024 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7887925
28 February 2024 Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7869114
30 March 2023 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7659352
30 November 2022 Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7601840
16 March 2022 COI Inspection · DAPI Audit
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7411702
17 February 2022 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7398049
26 April 2021 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7206688
31 March 2021 DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7166068
25 February 2021 Deficiency Check · Drydock Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7146218
10 June 2020 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7004976
16 April 2019 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6648717
18 January 2019 Examination of Repairs · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6607403
2 August 2018 Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6489209
15 March 2018 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6361558
23 February 2017 DAPI Audit · Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6093185
1 February 2017 Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6082211
24 January 2017 Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6076289
1 April 2016 Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5856455
10 March 2016 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5830482

Deficiency record · 41

10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 13 April 2026 Resolved
Stern light inoperable. Repaired prior to departure.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 14 April 2026
Resolved 14 April 2026
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 13 April 2026 Resolved
securing device missing on lazarette hatch. Repaired prior to departure.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 14 April 2026
Resolved 14 April 2026
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 3 March 2026 Resolved
3 stanchions in rod room on Stbd side just forward of the aft bulkhead are wasted where they penetrate the main deck and are carriage bolted to the frames. These are the stanchions only to support the gunwale/ waist. Make repairs as discussed with the attending Marine Inspector and work directly with the Marine Inspector to follow up and witness approved repair, prior to operation in passenger service.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 April 2026
Resolved 25 March 2026
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 20 March 2025 Resolved
PROVIDE THE CORRECT AMOUT OF FLARES.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 March 2025
Resolved 25 March 2025
Resolution: Received proof (photo) of the correct amount of flares onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 April 2024 Resolved
Provide name on lifering.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 April 2024
Resolved 17 April 2024
Resolution: Corrected
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 1 April 2024 Resolved
Prove proper operation of stern light. Prior to operating at night.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 1 April 2024
Resolved 17 April 2024
Resolution: Corrected
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 1 April 2024 Resolved
Provide 6 new oars for the 3 onboard lifefloats.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 April 2024
Resolved 17 April 2024
Resolution: Corrected
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 1 April 2024 Resolved
Provide engine room ventilation covers.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 April 2024
Resolved 17 April 2024
Resolution: Corrected
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 30 March 2023 Resolved
Provide servicing report for fixed and portable CO2 bottles prior to the carriage of passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 April 2023
Resolved 19 April 2023
Resolution: USCG Inspector saw servicing report.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 30 March 2023 Resolved
Replace painter line on aft most life float prior to carriage of passengers
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 April 2023
Resolved 19 April 2023
Resolution: Painter repaired.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 30 March 2023 Resolved
Obtain aspirin in First Aid Kit
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 April 2023
Resolved 7 April 2023
Resolution: o/o purchased new aspirin.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 30 March 2023 Resolved
Renew FCC Radio Telephony Certificate
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2023
Resolved 20 April 2023
Resolution: Received new certificate
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 30 March 2023 Resolved
Vsl needs new hydrostatic release for EPIRB.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 April 2023
Resolved 7 April 2023
Resolution: o/o purchased new hydrostatic release.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 31 March 2021 Resolved
An adult life jacket must be provided for each person carried on board. COI permits the carriage of 124 total persons. On board were only 120 type I Adult PFDs. While on board a vessel representative ordered 6 additional PFDs and provided an order confirmation.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 April 2021
Resolved 8 April 2021
Resolution: RCVD photo and reciept invoice of new PFDs purchased
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 31 March 2021 Resolved
Identified cracked window on the starboard side amidships. Replace cracked window for passenger safety.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2021
Resolved 8 April 2021
Resolution: RCVD photo via email of the cracked window replaced/ renewed.
05 - Radio Communications › N/A - No Subsystem › Functional requirements
Issued 31 March 2021 Resolved
Program MMSI and provide NEMA cable for installed VHF radios as required by FCC requirements. NEMA cable must be connected to a position source to provide position data in case of an emergency.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2021
Resolved 8 April 2021
Resolution: Def. check completed/ O/O purchased two new VHF-fm marine radios and programed.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 31 March 2021 Resolved
A vessel that operates on limited coastwise routes are required is required six hand red flares and six hand orange flares or substitutions identified in 46 CFR 180.68 (c). vessel had only 8 hand red flares at the time of the inspection and requires 4 more hand red flares in accordance with the substitution prescribed.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 April 2021
Resolved 1 April 2021
Resolution: Recieved photo evidence of 4 new flares purchased.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 31 March 2021 Resolved
New life ring purchased and installed without retro-reflective tape installed.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 31 March 2021
Resolved 31 March 2021
Resolution: Installed retro reflective tape prior to the completion of the inspection.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 31 March 2021 Resolved
Logs for life saving records maintenance not kept for EPIRB and primary life saving and fire fighting equipment.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 31 March 2021
Resolved 31 March 2021
Resolution: Established records for lifesaving maintenance for primary life saving equipment, fire fighting and EPIRB. Worked with the mariner to create a workable format.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 31 March 2021 Resolved
Painter line for the life floats were taped closed, preventing the free flowing payout of the painter line as designed.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 31 March 2021
Resolved 31 March 2021
Resolution: The tape securing the line was removed allowing for the free paying out of the painter line.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 16 April 2019 Resolved
Provide a high level audible and visual indication for the engine room. 46CFR182.530(a)
Action required: 17 - Rectify deficiencies prior to departure
Due 16 April 2019
Resolved 10 July 2019
Resolution: O/O replaced high level alarm
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 16 April 2019 Resolved
Replace life jacket donning placard to reflect current PFD's on board. 46CFR185.516
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 May 2019
Resolved 10 July 2019
Resolution: O/O replaced placard
Engineering › Bilge Water Management System › Interface Detector
Issued 15 March 2018 Resolved
#4 bilge alarm light on the bridge is inoperative.
Action required: 705 - Other - as specified
Due 30 April 2018
Resolved 2 August 2018
Resolution: Demonstarted operational readiness
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 15 March 2018 Resolved
Conduct drills prior to taking passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 April 2018
Resolved 2 August 2018
Resolution: Conducted satisfactory drills
Lifesaving › Lifebuoys › Serviceable
Issued 15 March 2018 Resolved
Wrong batteries in lights.
Action required: 705 - Other - as specified
Due 30 April 2018
Resolved 2 August 2018
Resolution: O/O installled proper batteries
Engineering › Bilge Water Management System › Valve
Issued 20 March 2017 Resolved
Repair/Replace bilge suction valve in engine room (controlling Lazarette) and prove proper operation.
Action required: 705 - Other - as specified
Due 4 April 2017
Resolved 31 March 2017
Resolution: replaced and operated
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 20 March 2017 Resolved
Repair/Replace port nav light. no night ops
Action required: 705 - Other - as specified
Due 20 March 2017
Resolved 31 March 2017
Resolution: replaced
Documentation › Certificates/Documents › FCC SSL
Issued 20 March 2017 Resolved
Provide copy/proof of FCC Station License
Action required: 705 - Other - as specified
Due 4 April 2017
Resolved 31 March 2017
Resolution: provided
Communications › Radio Communications › VHF Radiotelephone
Issued 20 March 2017 Resolved
Program MMSI into VHF/DSC capable radio.
Action required: 705 - Other - as specified
Due 4 April 2017
Resolved 31 March 2017
Resolution: completed
Communications › Radio Communications › EPIRB
Issued 20 March 2017 Resolved
Provide proof of EPIRB registration. Vessel restricted to operation w/in 3nm of shore.
Action required: 705 - Other - as specified
Due 20 March 2017
Resolved 31 March 2017
Resolution: provided
Engineering › Fuel Oil Service System › Piping
Issued 20 March 2017 Resolved
Repair/Replace fill pipe on stbd fuel tank (rusted).
Action required: 705 - Other - as specified
Due 20 April 2017
Resolved 31 March 2017
Resolution: completed
Electrical › Electric Supply System (service) › Battery Installation
Issued 20 March 2017 Resolved
Clean corroded battery terminals on 2nd battery bank from aft on stbd side.
Action required: 705 - Other - as specified
Due 4 April 2017
Resolved 31 March 2017
Resolution: cleaned
Electrical › Electrical Distribution System (service) › Wiring
Issued 20 March 2017 Resolved
Place wire hangers along stbd engine room electrical runs
Action required: 705 - Other - as specified
Due 20 April 2017
Resolved 31 March 2017
Resolution: completed
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 20 March 2017 Resolved
Remove/replace forepeak outlet
Action required: 705 - Other - as specified
Due 4 April 2017
Resolved 31 March 2017
Resolution: completed
Engineering › Bilge Water Management System › Valve
Issued 20 March 2017 Resolved
Remove/repair plastic wire ties on remote valve in 2nd compartment.
Action required: 705 - Other - as specified
Due 20 April 2017
Resolved 31 March 2017
Resolution: completed
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 20 March 2017 Resolved
Place/add chafing material to line under stbd engine.
Action required: 705 - Other - as specified
Due 4 April 2017
Resolved 31 March 2017
Resolution: completed
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 20 March 2017 Resolved
Install engine room air tight hatch cover (to seal space for CO2 discharge)
Action required: 705 - Other - as specified
Due 20 April 2017
Resolved 31 March 2017
Resolution: completed
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 10 March 2016 Resolved
Replace unusable PFD's. 30 PFD were taken out of service. Passenger count reduced to 94pax and 3 crew for a total of 97.
Due 24 March 2016
Resolved 1 April 2016
Resolution: Replaced 30PFD's.
Engineering › Bilge Water Management System › Valve
Issued 10 March 2016 Resolved
Replace handle for screw down valve in 2nd compartment.
Due 24 March 2016
Resolved 1 April 2016
Resolution: Replaced handle for screw down valve in the 2nd compartment.
Engineering › Fuel Oil Service System › Valve
Issued 10 March 2016 Resolved
Label fuel shut off valves
Due 24 March 2016
Resolved 1 April 2016
Engineering › Fuel Oil Service System › Valve, Control
Issued 10 March 2016 Resolved
Replace handle to fuel shut off on port side.
Due 24 March 2016
Resolved 18 April 2016
Resolution: Replaced handle to the fuel shut off on the port side.

Casualty record · 1

7 September 1998Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 1690071
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.