Records from 2016 to 2026. Most recent: inspection, 2 June 2026.
Inspection history · 27
2 June 2026
Administrative Inspection · Annual Inspection · Vessel Attendance
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8372353
2 January 2026
Drydock Exam · Examination of Repairs · Administrative Inspection · Internal Structural Exam · Vessel Attendance
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8289279
6 June 2025
Administrative Inspection · In-Service Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8153699
24 April 2025
Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8118381
9 April 2024
Deficiency Check · Internal Structural Exam · Annual Inspection · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7892636
26 October 2023
Drydock Exam · Internal Structural Exam · Administrative Inspection · Examination of Repairs
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7815102
4 October 2023
Deficiency Check · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7803525
22 February 2023
Administrative Inspection · Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7640181
27 December 2022
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7613550
15 December 2022
In-Service Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7609766
10 June 2022
Examination of Repairs · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7473897
27 January 2022
Administrative Inspection · COI Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7386486
7 December 2021
Drydock Exam · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7364222
21 July 2021
Damage Survey
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7268488
15 July 2021
Damage Survey
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 7257043
14 July 2021
Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 7262526
14 April 2021
Damage Survey
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7175183
7 January 2021
Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7120908
9 March 2020
Internal Structural Exam · Administrative Inspection · Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6923476
16 December 2019
Internal Structural Exam · Drydock Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6882399
21 February 2019
Internal Structural Exam · Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6630002
24 January 2019
Drydock Exam · In-Service Inspection · Internal Structural Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6614758
16 April 2018
In-Service Inspection · Annual Inspection · Internal Structural Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6392767
22 February 2017
Annual Inspection · DAPI Audit
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6092683
18 January 2017
Internal Structural Exam · Hull Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6072653
26 January 2016
Internal Structural Exam · Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5803070
12 January 2016
Hull Examination · Examination of Repairs
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5796170
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 1 May 2025
Resolved
Rails or equivalent protection must be installed near the periphery of all decks of a vessel accessible to passengers or crew. The height of top rails required by paragraph (a) of this section must at least 36 inches high. The height of the railing on the top passenger deck is only 30 inches in certain segments toward the aft end on both starboard and port sides. Rectify prior to carrying passengers on the upper deck.
46 CFR 177.900(d)(3)
Condition: Design Flaw
Action required: 705 - Other - as specified
Resolved 7 May 2025
Resolution: Received photos of chain rail in place.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 1 May 2025
Resolved
Rail courses or the equivalent must be installed between a top rail required by paragraph (a) of this section, and the deck so that no open space exists that is more than 12 inches. On the top passenger deck, the aft end of the port side top railing had a removable top rail equivalent, but the starboard side did not. Additionally, there were no rail courses in those areas, leaving gaps greater than 12 inches. Install at least a 36 inch top rail equivalent on the starboard side, and rail courses on both sides ensuring no gaps greater than 12 inches. Rectify prior to carrying passengers on the upper deck.
46 CFR 177.900(g)
Condition: Design Flaw
Action required: 705 - Other - as specified
Resolved 7 May 2025
Resolution: Received photos of chain rail in place.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 1 May 2025
Resolved
Vessels operated solely within 20 nautical miles of land must be equipped with a VHF-DSC radiotelephone installation meeting the requirements of § 80.1101(c)(2). Neither of the two VHF radios on board were connected to the GPS nor programmed with MMSI number.
47 CFR 80.905(a)(1)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2025
Resolved 5 May 2025
Resolution: Operator satisfactoryily wired GPS into the VHF radio.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 1 May 2025
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected. Generator windings and armature were heavily coated with oil posing a fire hazard. Make clean and ready for inspection no later than 05MAY.
46 CFR 176.830(a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 5 May 2025
Resolution: Operator cleaned generator to the satisfaction of the MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 1 May 2025
Resolved
In systems and applications where flexible hoses are permitted to be clamped: Two clamps must be used on each end of the hose, or one hose clamp can be used if the pipe ends are expanded or beaded to provide a positive stop against hose slippage. Observed one hose clamp on uptake to raw water for generator before strainer. Recommend checking all hoses for double clamping where practicable.
46 CFR 182.410(d)(4)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2025
Resolved 7 May 2025
Resolution: Received photos of clamps in place.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of Lifeboats
Issued 1 May 2025
Resolved
The floating waterlight must be attached around the body of the life float or buoyant apparatus by a 10 mm (3/8 inch) lanyard, resistant to deterioration from ultraviolet light, and at least 5.5 meters (18 feet) in length. The waterlight line was only approx. 8 ft.
46 CFR 180.175(f)(4)
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2025
Resolved 5 May 2025
Resolution: Operator replaced line to the required 18' length.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 30 April 2024
Resolved
Openings through which conductors enter shall be adequately closed. The engine room electrical distribution panel had 01 unused stuffing tube on the side that was not sealed. Repair to the satisfaction of the attending Marine Inspector. 46 CFR 183.10-20(f)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2024
Resolved 3 May 2024
Resolution: Vessel properly sealed the side of the electrical distribution panel.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 30 April 2024
Resolved
Nothing in this subpart limits the marine inspector from conducting such tests or inspections he or she deems necessary to be assured of the vessel's seaworthiness. Found 03 small holes in forepeak on the overhead deck.
Repair to the satisfaction of the attending Marine Inspector.
46 CFR 176.500(1)(iv)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2024
Resolved 3 May 2024
Resolution: Vessel sealed the holes on the overhead deck.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 30 April 2024
Resolved
Suitable covers, guards, or rails shall be installed in way of all exposed and hazardous places such as gears, machinery, etc. Found the vessels both main propulsion engines was missing a guard on the engine pulleys. Repair to the satisfaction of the attending Marine Inspector. 46 CFR 177.35-15 (f)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2024
Resolved 3 May 2024
Resolution: Vessel placed guards around both engine pulleys.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 April 2024
Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. The vessel had cabling hanging down from bulkhead to bulkhead in the compartment located below the crew accommodation space. Repair to the satisfaction of the attending Marine Inspector.
46 CFR 183.01-15 (a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2024
Resolved 3 May 2024
Resolution: Vessel corrected hanging cabling in the compartment below the crew accomodation space.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 30 April 2024
Resolved
Each battery used in an item of lifesaving equipment must be replaced during the annual inspection if the expiration date of the battery has passed. Found 02 waterlight batteries that were expired. Repair to the satisfaction of the attending Marine Inspector.46 CFR 185.726 (d)
Action required: 10 - Deficiency Rectified
Resolved 30 April 2024
Resolution: Vessel replaced the expired batteries for the water lights prior to conclusion of the inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 6 March 2023
Resolved
EACH VESSEL CERTIFIED TO OPERATE ON OCEANS ROUTE IN WARM WATER BE PROVIDED WITH LIFE FLOATS THAT WILL ACCOMMODATE AT LEAST 100% OF THE TOTAL PERSONS ON BOARD. VESSEL IS MISSING ONE LIFEFLOAT. VESSEL RESTRICTED TO OPERATING WITHIN 3 NM OF SHORE.
46 CFR 180.202 (b)(2)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 4 October 2023
Resolution: Reduced route to Lakes, Bays, and Sounds
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 6 March 2023
Resolved
VESSEL MUST COMPLY WITH THE APPLICABLE REQUIREMKENTS FOR ANY RADIO ISSUED BY THE FEDERAL COMMUNICATIONS. VESSEL DOES NOT HAVE NAVTEX OR MH RADIO ON BOARD. VESSEL RESTRICTED TO 20 NM WHILE OPERATING WITHOUT REQUIRED EQUIPMENT.
46 CFR 184.502
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 4 October 2023
Resolution: Reduced route to Lakes, Bays, and Sounds. Vessel had a working MF radio on board. Captain did not know location of radio
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 27 December 2022
Resolved
Fire Detection - Vessels described by 46 CFR 175.110 (c) must have an interconnected fire detection system in compliance with 46 CFR 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces. Vessel has not installed the interconnected detection and alarm systems to meet the new regulations outlined in 181.450. Vessel will install and test to the satisfaction of the attending MI and the vessel will be limited to a route of limited coastwise. 46 CFR 181.405 (c)
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 4 October 2023
Resolution: Reduced route to Lakes, Bays, and Sounds
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 15 July 2021
Resolved
fracture to starboard rear quarter along wit hside shell inset and bumber on transome
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Resolved 13 August 2021
Resolution: Damaged area has been repaired and NDT satisfactory.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 14 April 2021
Resolved
The intent of this part is to insure that the scantlings, material, fastenings, workmanship and arrangement of each vessel are such as to provide for safe operations in accordance with the terms of its certificate of inspection. Vessel owner reported that vessel struck drift (log) and experienced cavitation's after. Owner drydocked vessel and discovered a broken strut on the port side. Owner will submit repair proposal IAW 46 CFR 176.20-1 and make repairs to the satisfaction of the attending Marine Inspector. 46 CFR 177.01-5
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Resolved 28 June 2021
Resolution: All new metal installed and passed NDT's, conducted sea trials all were sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 19 January 2021
Resolved
On vessels of at least 26 feet in length, a visual and audible alarm must be provided at the operating station. On or before March 11, 1999, an existing vessel must comply with the bilge high level alarm requirements in 182.530.Vessels visual alarm was inoperable for the forward compartment.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 19 January 2021
Resolved 19 January 2021
Resolution: Loose wiring was found at the operating station. Wiring was repaired and alarm was tested. All SAT.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 19 January 2021
Resolved
All vessels shall be provided with a hand operated portable fire pump having a capacity of at least 5 gallons a minute. Hand fire pump was inoperable and had no discharge hose. IAW Old "T" 46 CFR 181.10-5(a)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 19 January 2021
Resolved 19 January 2021
Resolution: Hand pump was replaced with an operational hand pump with discharge hose.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 19 January 2021
Resolved
Auxillary machinery shall be suitable in type and design for the purpose intended. When operated to full starboard the steering ram contacts hull.IAW Old "T" 46 CFR 182.10-1
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 19 January 2021
Resolved 19 January 2021
Resolution: A spacer was added to the starboard rudder stop. Steering ram is no longer contacting hull.
Fire Fighting › Ventilation Systems › Ducts
Issued 17 April 2018
Resolved
07116-Fire Safety: Provision shall be made by means of plugs, covers, etc., to prevent the admission of air into the space protected. During Annual Inspection, no covers were found to cut off ventilation into engine room.
46 Old CFR 181.20-35
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 May 2018
Resolved 19 April 2018
Resolution: Vessel rep produced vents that would cut off ventilation into engine room.
Construction/Loadline › Hull › Side Shell
Issued 17 April 2018
Resolved
02112-Structural Conditions: Marine Inspector must examine all accessible parts of the exterior and interior of the hull, the watertight bulkheads, and weather deck. During Annual Inspection, pitting was found on the starboard aft side shell in the engine room.
46 Old CFR 176.25-5 (a)(1)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 May 2018
Resolved 19 April 2018
Resolution: Vessel rep applied epoxy to affected area to arrest pitting.