Records from 1984 to 1993. Most recent: inspection, 23 June 1993.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 22
23 June 1993
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 843293
13 September 1991
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 936099
31 August 1991
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 937012
19 June 1991
COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1213941
29 November 1990
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 913885
3 October 1990
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1243456
30 August 1990
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1230207
7 June 1990
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 902361
31 May 1990
Re-Inspection · Drydock Extension
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1213994
16 November 1989
Deficiency Check · Drydock Extension
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 913173
15 June 1989
Deficiency Check · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1226925
19 October 1988
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1197724
21 July 1988
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1044102
15 April 1988
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1348420
8 December 1987
Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1313087
26 October 1987
Drydock Extension
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1329339
17 June 1987
COI Inspection · Hull Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1333166
10 October 1986
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1322514
22 July 1986
Damage Survey
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1307327
13 January 1986
Deficiency Check · Examination of Repairs
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 997843
18 October 1985
Credit Drydock · COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 993705
4 December 1984
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1285966
Unknown
Issued 19 June 1991
Resolved
REPLACE HIGH JACKET WATER TEMP SENSOR ON EMERGENCY GENERATOR.
Condition: Unknown
Due 20 August 1991
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 19 June 1991
Resolved
REFILL HALON BOTTLE FOR EMERGENCY GENERATOR SPACE._x001C_ NOTE: GENERATOR IS TO BE CONSTANTLY ATTENDED DURING ROUTINE OPERATION AND TESTING UNTIL THIS REQUIREMENT IS SATISFIED.
Condition: Unknown
Due 20 August 1991
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 19 June 1991
Resolved
CONDUCT AND RECORD RESULTS OF TESTING ON ALL RELIEF VALVES FOR TENSIONER BOTTLES, PRIOR TO COMPLETION OF NEXT RIG MOVE.
Condition: Unknown
Due 30 November 1991
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 19 June 1991
Resolved
PROVIDE BUILDERS DRAWINGS AND EVIDENCE THAT THE "BACK UP AIR COMPRESSOR" PRESSURE VESSEL HAS BEEN BUILT TO ASME SECT. VIII (ESP. UG-46) REQUIREMENTSAND SHOP INSPECTED BY A U.S.C.G. MARINE INSPECTOR AS REQUIRED BY 46 CFR 54.10-3. UNIT IS TO BE REMOVED FROM SERVICE UNTIL THIS REQ. IS SATISFIED.
Condition: Unknown
Due 30 November 1991
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 19 June 1991
Resolved
CONDUCT THICKNESS GAUGING AT BOTTOMS OF ALL BULK TANKS AND PORT COLUMN, VALVE OPERATING, AIR RECEIVER. _x001C_ NOTE: A MINIMUM OF 3 GAUGINGS ARE TO BE TAKEN AT APPROX 120 DEGREE INTERVALS.
Condition: Unknown
Due 19 June 1991
Resolved 19 June 1991
Unknown
Issued 19 June 1991
Resolved
RENEW 'MARKLOAD' BOOM LOAD INDICATOR IN PORT AND STBD CRANES.
Condition: Unknown
Due 19 June 1991
Resolved 19 June 1991
Unknown
Issued 19 June 1991
Resolved
REFILL HELI-DECK FOAM TANK WITH NEW CHEMICAL FOAM SOLUTION._x001C_ NOTE: RIG IS PROHIBITED FROM CONDUCTING HELICOPTER REFUELING OPERATIONS UNTIL THIS REQUIREMENT IS SATISFIED._x001C_ _x001C_
Condition: Unknown
Due 19 June 1991
Resolved 19 June 1991
Unknown
Issued 19 June 1991
Resolved
PROVIDE ONE ADDITIONAL U.L. APPROVED 1.5" x 5O' FIREHOSE.
Condition: Unknown
Due 19 June 1991
Resolved 19 June 1991
Unknown
Issued 19 June 1991
Resolved
PROVIDE NEW BATTERY FOR EPIRB LOCATED ON HELI-DECK.
Condition: Unknown
Due 30 November 1991
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Unknown
Issued 19 June 1991
Resolved
PROVIDE EVIDENCE OF ANNUAL COASTAL STATE RADIO STATION SURVEY AS REQUIRED BY I.M.O. MODU CODE SECTION 11.10.1
Condition: Unknown
Due 30 November 1991
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Fire Fighting
Issued 31 May 1990
Resolved
COMPLETE ANNUAL SERVICING OF HALON SYSTEM PULL CABLES, PRESSURE TRIPS, ALARMS AND TIME DELAYS.
Condition: Unknown
Due 31 May 1990
Resolved 31 May 1990
Fire Fighting
Issued 31 May 1990
Resolved
COMPLETE HYDROSTATIC TESTING OF ALL PORTABLE CO2 CYLINDERS WHICH HAVE NOT BEEN SO TESTED SINCE MAY 85 (IDENTIFIED ON 19 MAY 90 SERVICING RECORD). CYLINDARS SHALL NOT BE REMOVED UNTIL SUITABLE REPLACEMENTS ARE PLACED ON BOARD.
Condition: Unknown
Due 31 May 1990
Resolved 31 May 1990
Accommodation/Occupational Safety
Issued 31 May 1990
Resolved
PROVIDE DOCUMENTATION CONCERNING THE FLAME SPREAD/SMOKE DEVELOPED RATINGS, OR CRITICAL RADIANT FLUX/OPTICAL DENSITY CHARACTERISTICS OF THE HUEGA 581 CARPETING INSTALLED IN THE UPPER DECK ACCOMMODATION AREAS.
Condition: Unknown
Due 31 May 1990
Resolved 31 May 1990
Accommodation/Occupational Safety
Issued 31 May 1990
Resolved
PROVIDE BREATHALYZER UNIT PER 46 CFR 4.06-20 AND PROVIDE EVIDENCE THAT URINE SPECIMEN KIT CAN BE MADE AVAILABLE WITHIN TIME PERIOD SPECIFIED IN 46 CFR 4.06-20(B).
Condition: Unknown
Due 31 May 1990
Resolved 31 May 1990
Electrical
Issued 31 May 1990
Resolved
PROVIDE NON CONDUCTIVE MAT ADJACENT TO EMERGENCY GENERATOR SWITCHBOARD, AND MOTOR CONTROLLER PANEL.
Condition: Unknown
Due 31 May 1990
Resolved 31 May 1990
Accommodation/Occupational Safety
Issued 31 May 1990
Resolved
REPLACE EXISTING ENGINE START AIR RECEIVER RELIEF VALVES WITH APPROVED TYPESET AT OR BELOW 125PSI.
Condition: Unknown
Due 31 May 1990
Resolved 31 May 1990
Accommodation/Occupational Safety
Issued 31 May 1990
Resolved
PROVIDE APPROVE TYPE RELIEF VALVE SET AT OR BELOW 200PSI FOR STBD CRANE STARTING AIR RECEIVER.
Condition: Unknown
Due 31 May 1990
Resolved 31 May 1990
Electrical
Issued 31 May 1990
Resolved
PROVIDE SUITABLE CLASSIFIED LOCATION LIGHTING FIXTURES FOR #3 BOAT STATION EMERGENCY LIGHTING, OR REPOSITION EXISTING FIXTURES OUT OF CLASSIFIED LOCATION.
Condition: Unknown
Due 31 May 1990
Resolved 31 May 1990
Fire Fighting
Issued 31 May 1990
Resolved
CALIBRATE SCOTT AND GASTECH PORTABLE O2/%LEL METERS.
Condition: Unknown
Due 31 May 1990
Resolved 31 May 1990
Lifesaving
Issued 16 November 1989
Resolved
PROVIDE AND INSTALL ONE ADDITIONAL (5 TOTAL) USCG APPROVED DAVIT LAUNCHED LIFERAFT FOR A MINIMUM OF 6 PERSONS. INSTALLATION SHALL INCLUDE APPROVED LAUNCHING EQUIPMENT. UNTIL THIS RAFT IS INSTALLED, THE TOTAL PERSONS ALLOWED ON BOARD IS RESTRICTED TO 100 (46 CFR 108.505/108.506/108.508).
Condition: Unknown
Due 16 November 1989
Resolved 16 November 1989
Construction/Loadline
Issued 16 November 1989
Resolved
REPAIR AND PROVE OPERATION OF REMOTE ACTIVATORS TO STBD COLUMN HIGH BALLASTSUCTION SEA VALVES (ONE PER COLUMN).
Condition: Unknown
Due 16 November 1989
Resolved 16 November 1989
Accommodation/Occupational Safety
Issued 15 June 1989
Resolved
REPAIR AND PROVE OPERATION OF THE GENERAL ALARM BELL AND LIGHT IN THE GENERATOR ROOM.
Condition: Unknown
Due 15 June 1989
Resolved 15 June 1989
Lifesaving
Issued 21 July 1988
Resolved
PROVIDE A 1800' AUXILIARY LINE FOR THE UNITS LINE THROWING GUN.
Condition: Unknown
Due 21 July 1988
Resolved 21 July 1988
Fire Fighting
Issued 21 July 1988
Resolved
TEST, RECHARGE AND REINSTALL THE HALON BOTTLE FOR THE EMERGENCY GENERATOR ROOM.
Condition: Unknown
Due 21 July 1988
Resolved 21 July 1988
Fire Fighting
Issued 21 July 1988
Resolved
DEMONSTRATE THE OPERATION OF THE EMERGENCY GENERATOR HALON SYSTEM PRESSURE SWITCH SHUTDOWN.
Condition: Unknown
Due 21 July 1988
Resolved 21 July 1988
Documentation
Issued 21 July 1988
Resolved
PROVIDE EVIDENCE OF COMPLETION OF ANNUAL SURVEY OF VMW CRANE.
Condition: Unknown
Due 21 July 1988
Resolved 21 July 1988
Electrical
Issued 21 July 1988
Resolved
RENEW THE SELF CLOSING GAS TIGHT DOOR BETWEEN THE MUD PIT AND MUD PUMP ROOMS.
Condition: Unknown
Due 21 July 1988
Resolved 21 July 1988
Fire Fighting
Issued 21 July 1988
Resolved
WEIGH ALL HALON BOTTLES AND PROVIDE REPORT WHICH INCLUDES BOTH FULL AND ACTUAL WEIGHTS.
Condition: Unknown
Due 21 July 1988
Resolved 21 July 1988
Fire Fighting
Issued 21 July 1988
Resolved
INSTALL THE ELECTRICALLY OPERATED STOP VALVE (2") IN THE HELO DECK FOAM SYSTEM AS RECOMMENDED BY HILLER (MANUFACTURER), TO PREVENT MIGRATION OF SALT WATER INTO THE FOAM BLADDER.
Condition: Unknown
Due 21 July 1988
Resolved 21 July 1988
Documentation
Issued 21 July 1988
Resolved
PROVIDE EVIDENCE OF COMPLETION OF ANNUAL LOAD LINE SURVEY.
Condition: Unknown
Due 21 July 1988
Resolved 21 July 1988
Construction/Loadline
Issued 8 December 1987
Resolved
SUBMIT A DIVERS REPORT AND VIDEO TAPE OF THE PORT AND STARBOARD PONTOONS TO THE [name withheld] THE RESIDENT COAST GUARD INSPECTOR IN SINGAPORE.
Condition: Unknown
Due 8 December 1987
Resolved 8 December 1987
Lifesaving
Issued 8 December 1987
Resolved
REMOVE FROM THE VESSEL ALL NON-USCG APPROVED IMMERSION SUITS.
Condition: Unknown
Due 8 December 1987
Resolved 8 December 1987
Lifesaving
Issued 8 December 1987
Resolved
SERVICE THE AFT DAVIT LAUNCHED LIFE RAFT LOCATED ON THE PORT SIDE.
Condition: Unknown
Due 8 December 1987
Resolved 8 December 1987
Fire Fighting
Issued 10 October 1986
Resolved
FOAM SAMPLES FROM THE STARBOARD PUMPROOM AND HELO DECK FOAM STATIONS ARE TOBE TESTED AND THE RESULTS FORWARDED TO MSO HONOLULU FOR REVIEW.
Condition: Unknown
Due 10 October 1986
Resolved 10 October 1986
Lifesaving
Issued 10 October 1986
Resolved
CONDUCT ALTERATIONS TO THREE LIFEBOATS FOR INSTALLATION OF CANOPY ANTENNA FOR INSTALLATION OF PORTABLE ITT TRANSCEIVER. SUBMIT ASSOCIATED DRAWINGS TO MARINE SAFETY OFFICE HONOLULU FOR APPROVAL OF THE INSTALLATION.
Condition: Unknown
Due 10 October 1986
Resolved 10 October 1986
Unknown
Issued 10 October 1986
Resolved
THE REQUIREMENTS OF NFPA 496 REQUIRE THE DRILL FLOOR PUMP STROKE INDICATOR TO BE PURGED AND THE INDICATOR ATTACHED TO SHOW POSITIVE PRESSURE. DRILLERCONSOLE G.E. CABINET IS TO BE SEALED AND THE PURGE INDICATOR IS TO OPERATE OFF OF CABINET PRESSURE AND NOT OFF OF SUPPLIED AIR SYSTEM.
Condition: Unknown
Due 10 October 1986
Resolved 10 October 1986
Unknown
Issued 13 January 1986
Resolved
CONDUCT FOLLOW-ON NON-DESTRUCTIVE TESTING ON THE STARBOARD COLUMN AFTER BALLAST SEACHEST SHELL AND STRUCTURAL CONNECTION WELDS. MPI AND UT TESTS WILL BE MADE AND COMPARED WITH TESTS MADE 11 AND 12 JANUARY 1986.
Condition: Unknown
Due 13 January 1986
Resolved 13 January 1986
Deck/Cargo
Issued 13 January 1986
Resolved
THE VICTORIA MACHINE WORKERS CRANE MODEL CH-10 SHALL BE INSPECTED AND TEST-ED IN ACCORDANCE WITH API STANDARDS. POSTING MAXIMUM SAFE WORKING LOADS AND BE CERTIFICATED BY AN APPROVED ORGAINZATION. THIS REQUIREMENT WAS ISSUED 15NOV84 IS 15 MONTHS OVER-DUE AND SHALL BE COMPLETED IMMEDIATELY.
Condition: Unknown
Due 13 January 1986
Resolved 13 January 1986
Unknown
Issued 18 October 1985
Resolved
PROVIDE ONE (1) ADDITIONAL LIFE RING BUOY FOR A TOTAL OF 8.
Condition: Unknown
Due 18 October 1985
Resolved 18 October 1985
Unknown
Issued 18 October 1985
Resolved
REPAIR AND PROVIDE A SATISFACTORY FULL PENETRATION WELD TO THE PREVIOUSLY FRACTURED AREA OF #6 ANCHOR FAIRLEAD.
Condition: Unknown
Due 18 October 1985
Resolved 18 October 1985
Unknown
Issued 18 October 1985
Resolved
PROVIDE NOZZLE TIPS OR NEW NOZZLES AT FIRE STATIONS #1 AND #2.
Condition: Unknown
Due 18 October 1985
Resolved 18 October 1985
Unknown
Issued 18 October 1985
Resolved
FOAM SAMPLES FROM THE STBD PUMP ROOM AND HELO DECK FOAM EXTINGUISHING SYSTEMS SHALL BE TESTED IN ACCORDANCE WITH 46 CFR 107.235(B)(2)(III) AND (3) AND RESULTS REPORTED TO MSO HONOLULU.
Condition: Unknown
Due 18 October 1985
Resolved 18 October 1985
Unknown
Issued 18 October 1985
Resolved
REPAIR PORTABLE LIFEBOAT RADIO TO RESTORE RECEIVING CAPABILITY.
Condition: Unknown
Due 18 October 1985
Resolved 18 October 1985
Unknown
Issued 18 October 1985
Resolved
MAKE PERMANENT REPAIRS LIKE ORIGINAL TO THE STBD AFT LOWER BALLAST AND S.W.SERVICE SEACHESTS.
Condition: Unknown
Due 18 October 1985
Resolved 18 October 1985
Unknown
Issued 18 October 1985
Resolved
RENEW LIFE BOAT #1 FALL ON THE FORWARD DRUM AND PROVIDE WIRE/RING CERTIFICATES.
Condition: Unknown
Due 18 October 1985
Resolved 18 October 1985
Unknown
Issued 18 October 1985
Resolved
PROVIDE VISUAL OR AUDIBLE ALARMS WHERE READILY SEEN OR HEARD UPON PURGE FAILURE IAW NFPA 496 FOR THE FOLLOWING PURGED ENCLOSURES: DRILLERS CONSOLE,FOOT THROTTLE, GENERAL ALARM CONTACT MAKER, AND N.L. SHAFFER MOTION COMPENSATOR CONTROLLER JUNCTION BOXES.
Condition: Unknown
Due 18 October 1985
Resolved 18 October 1985
Unknown
Issued 18 October 1985
Resolved
PROVIDE THE FOLLOWING LIFEBOAT GEAR: L/B #1 - 70 QUARTS OF WATER, 30 LBS PROVISIONS; L/B #2 - 100 QUARTS OF WATER, 88 LBS PROVISIONS; L/B #3 - 26 LBS PROVISIONS.
Condition: Unknown
Due 18 October 1985
Resolved 18 October 1985