Records from 1985 to 1999. Most recent: inspection, 23 April 1999.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 24
23 April 1999
Type not recorded
No type recorded · Station Fort Pierce · USCG Southeast District (CGD-SE) · Activity 1532749
12 September 1996
Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1264385
17 November 1995
Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 877318
21 September 1995
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1184763
10 August 1995
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1184848
19 December 1994
Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1158469
2 November 1994
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1174604
16 August 1994
MARPOL Annex V Examination · Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 861201
29 December 1993
Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 850690
25 August 1993
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 847447
2 October 1992
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 931153
21 August 1992
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1256299
22 August 1991
Re-Inspection · Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 937101
22 October 1990
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 906312
20 September 1990
Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 913222
21 August 1990
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1222896
5 October 1989
COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1212241
29 August 1989
Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1311648
27 February 1989
Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1351210
31 August 1988
Hull Examination · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1347953
10 September 1987
Re-Inspection · Hull Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1004704
15 January 1987
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1007572
23 October 1986
Credit Drydock · COI Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1011485
16 September 1985
Credit Drydock · Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1301514
Lifesaving
Issued 2 November 1994
Resolved
PROVIDE A FLOAT LIGHT FOR THE RING BUOY, VESSEL RESTRICTED FROM OPERATING AT NIGHT UNTIL COMPLIANCE.
Condition: Unknown
Due 2 November 1994
Resolved 2 November 1994
Lifesaving
Issued 25 August 1993
Resolved
PROVIDE ONE ADDITIONAL ADULT LIFEJACKET. VESSEL RESTRICTED TO 25 PERSONS ONBOARD UNTIL COMPLIANCE.
Condition: Unknown
Due 25 August 1993
Resolved 25 August 1993
Documentation
Issued 25 August 1993
Resolved
SUBMIT WRITTEN PROOF OF A CHEMICAL TESTING PROGRAM WHICH COMPLIES WITH 46 CFR PART 16 TO COAST GUARD MSO MIAMI.
Condition: Unknown
Due 25 August 1993
Resolved 25 August 1993
Engineering
Issued 2 October 1992
Resolved
RENEW PORT FUEL TANK VENT SCREEN.
Condition: Unknown
Due 15 October 1992
Resolved 14 October 1992
Lifesaving
Issued 2 October 1992
Resolved
PROVIDE 3 ADDITIONAL ADULT LIFE JACKETS. VESSEL RESTRICTED TO 23 TOTAL PERSONS UNTIL COMPLIANCE.
Condition: Unknown
Due 15 October 1992
Resolved 14 October 1992
Navigation
Issued 2 October 1992
Resolved
PROVE PROPER OPERATION OF MARINE RADIO. VESSEL RESTRICTED TO 1000 FT ROUTEUNTIL COMPLIANCE.
Condition: Unknown
Due 15 October 1992
Resolved 14 October 1992
Lifesaving
Issued 20 September 1990
Resolved
MARK ADULT LIFEJACKET STOWAGE LOCATION AND NUMBER WITH LETTERS AND FIGURES AT LEAST ONE INCH IN HEIGHT.
Condition: Unknown
Due 20 September 1990
Resolved 20 September 1990
Documentation
Issued 20 September 1990
Resolved
POST GARBAGE POLLUTION PLACARD ONBOARD VESSEL
Condition: Unknown
Due 20 September 1990
Resolved 20 September 1990
Lifesaving
Issued 20 September 1990
Resolved
MARK RING LIFE BOUY WITH VESSEL'S NAME
Condition: Unknown
Due 20 September 1990
Resolved 20 September 1990
Lifesaving
Issued 10 September 1987
Resolved
PROVIDE ONE ADDITIONAL CHILD'S PFD.
Condition: Unknown
Due 10 September 1987
Resolved 10 September 1987
Engineering
Issued 10 September 1987
Resolved
TEST RUN ENGINES.
Condition: Unknown
Due 10 September 1987
Resolved 10 September 1987
Lifesaving
Issued 10 September 1987
Resolved
RE-NEW RING BUOY.
Condition: Unknown
Due 10 September 1987
Resolved 10 September 1987