MAURY USCG vessel records Sign in
← All vessels

ENCOUNTER

ENCOUNTER is a 1983 tank ship. The Coast Guard has recorded 23 inspections since 1985, most recently in March 1997, along with 24 deficiencies and 1 operational control.

Records from 1985 to 1997. Most recent: inspection, 9 March 1997.

Built
1983
Last inspected
9 March 1997
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8307959 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
228718
Flag
PANAMA
—
Maury page id
psix-228718

Inspections, by type

…with no type recorded17
Years with a record 9 calendar years (1985–1997)
The 23 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 29 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it12900 - Dead Weight, Ton
7195 - Regulatory (Subpart C or D), Gross Ton
4025 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 23

9 March 1997 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 401373
7 March 1997 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1100495
9 August 1996 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 393999
19 January 1996 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 650099
12 January 1996 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 386729
12 January 1996 Letter of Compliance (Initial/Renewal)
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1377591
16 April 1995 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 499755
19 February 1995 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 375417
16 February 1995 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 650098
3 February 1995 Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 374888
3 February 1995 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 833919
17 June 1994 Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1327598
13 June 1993 Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 841795
12 April 1990 Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 926861
12 January 1990 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1226354
9 January 1990 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1218656
7 April 1988 Certificate of Compliance
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1303149
23 February 1988 Type not recorded
No type recorded · THE UNKNOWN UNIT · Activity 1024191
25 August 1986 Deficiency Check
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1300514
22 August 1986 Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1295871
21 August 1986 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 447908
15 June 1985 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 525398
14 June 1985 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 475882

Deficiency record · 24

Lifesaving
Issued 9 March 1997 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 13 March 1997
Resolved 13 March 1997
Fire Fighting
Issued 12 January 1996 Resolved
Store fire extinguishers in brackets ready for immediate use. _x001C_ SOLAS II-2, Reg. 15
Condition: Unknown
Due 12 February 1996
Resolved 5 March 1996
Engineering
Issued 12 January 1996 Resolved
Repair damaged fuel oil and water head vents as needed. _x001C_ SOLAS II-2, Reg 2.8 & ICLL, Reg 20
Condition: Unknown
Due 12 February 1996
Resolved 5 March 1996
Lifesaving
Issued 12 January 1996 Resolved
Replace missing lifeboat equipment. (survival manuals, damaged oars and unsealed rations) _x001C_ SOLAS III, Reg. 11
Condition: Unknown
Due 18 January 1996
Resolved 18 January 1996
Fire Fighting
Issued 12 January 1996 Resolved
Repair hole in deck foam line, starboard side, forward of pumproom. _x001C_ SOLAS, II-2, Reg 15
Condition: Unknown
Due 12 February 1996
Resolved 5 March 1996
Unknown
Issued 12 January 1996 Resolved
Plastics may not be disposed overboard.
Condition: Unknown
Due 17 January 1996
Resolved 17 January 1996
Lifesaving
Issued 12 January 1996 Resolved
Repair wasted embarkation ladder. _x001C_ SOLAS III, Reg 19
Condition: Unknown
Due 12 February 1996
Resolved 5 March 1996
Fire Fighting
Issued 12 January 1996 Resolved
Provide required portable foam unit in engine room. _x001C_ SOLAS II-2, Reg 6.4
Condition: Unknown
Due 18 January 1996
Resolved 18 January 1996
Fire Fighting
Issued 12 January 1996 Resolved
Repair piping to general service fire pump. _x001C_ SOLAS II-2, Reg 15
Condition: Unknown
Due 18 January 1996
Resolved 18 January 1996
Engineering
Issued 12 January 1996 Resolved
Repair soft patched main engine salt water coolant line. _x001C_ SOLAS II-1, Reg 26.2
Condition: Unknown
Due 18 January 1996
Resolved 18 January 1996
Deck/Cargo
Issued 19 February 1995 Resolved
OUTSTANDING RECOMMENDATION FOR VAPOR CONTROL SYSTEM: BLANK FLANGES PLACED ON VCS PIPING MANIFOLD AND UPDATE OIL TRANSFER PROCEDURES FOR VCS.
Condition: Unknown
Due 24 April 1995
Resolved 24 April 1995
Deck/Cargo
Issued 3 February 1995 Resolved
PROVIDE MARINE CHEMIST AND MAKE CARGO PUMPROOM SAFE FOR ENTRY AT NEXT U.S. PORT.
Condition: Unknown
Due 3 March 1995
Resolved 3 March 1995
Deck/Cargo
Issued 3 February 1995 Resolved
PROVIDE MECHANICAL SCUPPER CLOSURES FOR ALL DECK SCUPPERS.
Condition: Unknown
Due 3 March 1995
Resolved 3 March 1995
Accommodation/Occupational Safety
Issued 3 February 1995 Resolved
REMOVE ALL HOLD BACK HOOKS ON FIRE DOORS IN CLASS "A" BOUNDARIES PER SOLAS 74 CH II-2, PART E, REG 57(b)(vii).
Condition: Unknown
Due 3 March 1995
Resolved 3 March 1995
Lifesaving
Issued 3 February 1995 Resolved
PROVIDE SOLAS APPROVED LIGHTS FOR PFD'S WHERE MISSING PER SOLAS 74.
Condition: Unknown
Due 3 March 1995
Resolved 3 March 1995
Documentation
Issued 3 February 1995 Resolved
PROVIDE ANNEX NO. A-OHO-141MII TO THE CERTIFICATE OF FITNESS PRIOR TO RETURN TO U.S. WATERS.
Condition: Unknown
Due 3 March 1995
Resolved 16 February 1995
Lifesaving
Issued 3 February 1995 Resolved
PROVIDE FIRE RESISTANT, WEATHERTIGHT COVER FOR STBD LIFEBOAT ENGINE PER SOLAS 74 CH III-3 REG 9(a)(ii).
Condition: Unknown
Due 24 April 1995
Resolved 24 April 1995
Navigation
Issued 13 June 1993 Resolved
PRIOR TO NEXT U.S. VOYAGE, INSTALL AN AUDIBLE AND VISUAL ALARM FOR LOSS OF POWER ON THE VESSSEL'S NAVIGATION BRIDGE.
Condition: Unknown
Due 13 June 1993
Resolved 13 June 1993
Navigation
Issued 13 June 1993 Resolved
PRIOR TO NEXT U.S. VOYAGE, INSTALL AN AUDIBLE AND VISUAL ALARM FOR LOW HYDRAULIC FLUID LEVEL IN STEERING GEAR HYDRAULIC FLUID RESERVOIR ON THE VESSEL'S NAVIGATION BRIDGE.
Condition: Unknown
Due 13 June 1993
Resolved 13 June 1993
Lifesaving
Issued 13 June 1993 Resolved
HAVE VESSEL'S SELF CONTAINED BREATHING APPARATI PROFESSIONALLY SERVICED PRIOR TO NEXT U.S. VOYAGE.
Condition: Unknown
Due 13 June 1993
Resolved 13 June 1993
Deck/Cargo
Issued 13 June 1993 Resolved
HYDROSTATICALLY TEST VESSEL'S CARGO PIPING TO 1.5 TIMES THE MAXIMUM ALLOWABLE WORKING PRESSURE PRIOR TO NEXT U.S. VOYAGE.
Condition: Unknown
Due 13 June 1993
Resolved 13 June 1993
Deck/Cargo
Issued 12 April 1990 Resolved
PROVIDE SPAN GAS FOR TOXIC GAS DETECTOR AND TEST AND CALIBRATE SYSTEM, NO TOXIC CHEMICALS TO BE CARRIED UNTIL TOXIC GAS DETECTOR TESTED TO SATISFAC- TION OF COGNIZANT OCMI.
Condition: Unknown
Due 12 April 1990
Resolved 12 April 1990
Fire Fighting
Issued 9 January 1990 Resolved
MAKE PERMANENT REPAIRS TO TEMPORARY REPAIR OF FIRE MAIN PIPING WHERE HOLED,LOCATED ON CARGO DECK BENEATH MONITOR, ABOVE #4 CENTER CARG0 TANK, PRIOR TOFIRST US PORT NEXT VOYAGE, NO LATER THAN 10FEB90.
Condition: Unknown
Due 9 January 1990
Resolved 9 January 1990
Fire Fighting
Issued 22 August 1986 Resolved
PRIOR TO ENTERING US WATERS AFTER 30SEP86, HAVE ALL SCBA'S SERVICED BY A PROFESSIONAL.
Condition: Unknown
Due 22 August 1986
Resolved 22 August 1986

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.