Records from 1985 to 1996. Most recent: inspection, 27 June 1996.
Inspection history · 52
27 June 1996
Type not recorded
No type recorded · MSFO BUCKSPORT · USCG Northeast District (CGD-NE) · Activity 529208
22 March 1996
Type not recorded
No type recorded · MSFO BUCKSPORT · USCG Northeast District (CGD-NE) · Activity 389342
31 January 1996
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 516130
31 January 1996
Tank Vessel Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1186673
31 January 1996
Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1193138
14 December 1995
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 516928
23 April 1995
Type not recorded
No type recorded · MSFO Portsmouth · USCG Northeast District (CGD-NE) · Activity 449733
24 March 1995
Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 827132
15 March 1995
Type not recorded
No type recorded · MSFO BUCKSPORT · USCG Northeast District (CGD-NE) · Activity 376231
15 December 1994
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 647481
14 December 1994
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 444079
11 November 1994
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 132032
20 October 1994
Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1180765
4 September 1994
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1172666
4 September 1994
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1450894
6 July 1994
Deficiency Check
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 862324
5 June 1994
Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1018305
18 May 1994
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 532314
18 May 1994
Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1170323
18 May 1994
Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1170326
6 May 1994
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 858859
5 May 1994
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1014140
2 December 1993
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 488519
10 September 1993
Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 832410
13 July 1993
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 847037
5 April 1993
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 492843
17 June 1992
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 470561
12 June 1992
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 539561
21 May 1992
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 944229
8 May 1992
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 350661
10 December 1991
Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 485232
6 June 1991
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1240347
21 March 1991
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1242477
12 March 1991
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 342391
2 February 1991
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 477678
23 May 1990
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1211552
16 February 1990
Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1230477
24 October 1989
Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1202182
20 September 1989
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 332681
11 September 1989
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 457330
4 April 1989
Re-Inspection · Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1347200
5 October 1988
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 463009
27 September 1988
Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1044903
11 June 1988
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1194588
28 January 1988
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 516526
25 October 1987
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 319298
3 July 1987
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 475966
3 June 1987
Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1334866
17 December 1986
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 455705
11 June 1986
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1299277
9 April 1986
Credit Drydock
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 998461
17 November 1985
Deficiency Check · Re-Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1305210
Deck/Cargo
Issued 5 June 1994
Resolved
PROVE PROPER OPERATION OF #3 CARGO PUMP OVERSPEED TRIP PRIOR TO DISCHARGE OF CARGO THROUGH #3 PUMP.
Condition: Unknown
Due 5 June 1994
Resolved 5 June 1994
Deck/Cargo
Issued 6 May 1994
Resolved
REPLACE VENT SCREEN OVER #1 CARGO PUMP NOT LATER THAN 31 MAY 1994.
Condition: Unknown
Due 6 May 1994
Resolved 6 May 1994
Deck/Cargo
Issued 6 May 1994
Resolved
SHOW PROPER OPERATION OF #1 CARGO PUMP ENGINE OVERSPEED TRIP PRIOR TO DISCHARGING CARGO AT NEXT U. S. PORT BUT NOT LATER THAN 31 MAY 1994.
Condition: Unknown
Due 6 May 1994
Resolved 6 May 1994
Construction/Loadline
Issued 6 May 1994
Resolved
MAKE CARGO PUMP ROOM BILGES AVAILABLE FOR INSPECTION BY AN ATTENDING U. S. COAST GUARD MARINE INSPECTOR PRIOR TO DISCHARGING CARGO AT NEXT U. S. PORT BUT NOT LATER THAN 31 MAY 1994.
Condition: Unknown
Due 6 May 1994
Resolved 6 May 1994
Deck/Cargo
Issued 6 May 1994
Resolved
SHOW PROPER OPERATION OF #3 CARGO PUMP OVERSPEED TRIP PRIOR TO CARGO DISCHARGE AT NEXT U.S. PORT.
Condition: Unknown
Due 6 May 1994
Resolved 6 May 1994
Electrical
Issued 6 May 1994
Resolved
SHOW PROPER OPERATION OF #1 GENERATOR OVERSPEED TO THE SATISFACTION OF AN ATTENDING U. S. COAST GUARD MARINE INSPECTOR NOT LATER THAN 31 MAY 1994.
Condition: Unknown
Due 6 May 1994
Resolved 6 May 1994
Construction/Loadline
Issued 5 May 1994
Resolved
MAKE CARGO TANK INTERNALS AVAILABLE FOR INSPECTION BY AN ATTENDING U. S. COAST GUARD MARINE INSPECTOR DURING DOCKSIDE MAINTENANCE PERIOD JANUARY TO MARCH 1995, BUT NOT LATER THAN 15 MARCH 1995, PRIOR TO MAKING INTERNAL REPAIRS.
Condition: Unknown
Due 5 May 1994
Resolved 5 May 1994
Accommodation/Occupational Safety
Issued 13 July 1993
Resolved
PROVIDE MANUFACTURERS TEST PROCEDURES FOR INSTALLED THERMAL FLUID HEATERS.
Condition: Unknown
Due 13 July 1993
Resolved 13 July 1993
Engineering
Issued 6 June 1991
Resolved
EMERGENCY GENERATOR CRANKSHAFT EXPOSED. PROVIDE GUARD FOR GENERATOR CRANK SHAFT.
Condition: Unknown
Due 6 June 1991
Resolved 6 June 1991
Electrical
Issued 4 April 1989
Resolved
PROVIDE & INSTALL ELECTRIC SHUTDOWN FOR #3 GENERATOR.
Condition: Unknown
Due 4 April 1989
Resolved 4 April 1989
Fire Fighting
Issued 3 June 1987
Resolved
OUTBOARD S/S GEN DOES NOT HAVE AUTOMATIC HALON SHUTDOWN. PROVIDE AUTOMATIC HALON SHUTDOWN FOR OUTBOARD S/S GEN.
Condition: Unknown
Due 3 June 1987
Resolved 3 June 1987
Fire Fighting
Issued 3 June 1987
Resolved
PROVIDE INSTRUCTIONS FOR LOCAL DISCHARGE OF HALON IN HALON ROOM. INSTRUCTIONS TO BE PROVIDED AT CYLINDERS FOR BOTH ENGINE ROOM AND PUMP ROOMCYLINDERS. NAVIC 6-72 AND 6-72 CHANGE 1 TO BE USED AS A GUIDE.
Condition: Unknown
Due 3 June 1987
Resolved 3 June 1987
Electrical
Issued 17 November 1985
Resolved
INSTALL AND TEST #2 SHIPS SERVICE GENERATOR. TEST IN PRESENCE OF U.S. COAST GUARD MARINE INSPECTOR BY 17 JAN. 1985
Condition: Unknown
Due 17 November 1985
Resolved 17 November 1985