YEOCOMICO II

YEOCOMICO II is a 1940 freight ship. The Coast Guard has recorded 52 inspections since 1984, most recently in February 2024, along with 182 deficiencies and 12 operational controls.

Records from 1984 to 2024. Most recent: inspection, 8 February 2024.

Built
1940
Last inspected
8 February 2024
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7647326 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
228781
Flag
BAHAMAS, THE
—
Maury page id
psix-228781

Inspections, by type

…with no type recorded47
Years with a record 18 calendar years (1984–2024)
The 52 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it194 - Convention (Subpart B), Net Ton
194 - Regulatory (Subpart C or D), Net Ton
359 - Convention (Subpart B), Gross Ton
359 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 52

8 February 2024 Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7862713
23 July 2003 Re-Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1854742
17 June 2003 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1819702
24 May 2003 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1801040
19 May 2003 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1796744
14 May 2003 Type not recorded
No type recorded · USCGC CORMORANT (WPB 87313) · USCG Southeast District (CGD-SE) · Activity 1895777
13 December 2002 Deficiency Check · Annual Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1717999
29 November 2002 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1712079
25 November 2002 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1710495
28 August 2002 Administrative Inspection
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1667961
12 August 2002 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1660369
8 August 2002 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1658306
27 February 2001 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 522251
7 October 2000 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 282769
14 February 2000 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 274864
3 September 1999 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 432348
16 August 1999 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 463329
21 April 1999 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 124146
1 March 1999 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 474797
1 March 1999 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 539271
19 January 1999 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 540780
13 July 1998 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 417969
4 June 1998 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 417150
26 August 1997 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 529928
19 August 1997 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 407591
22 July 1997 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 405601
22 July 1997 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 407182
24 April 1997 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 487034
31 March 1997 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 536102
11 March 1997 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 58039
8 September 1996 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 647273
27 August 1996 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 394807
28 June 1996 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 392552
1 April 1996 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 389594
20 August 1995 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 381887
14 June 1995 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 647274
9 May 1995 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 378246
6 September 1994 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 370483
6 September 1994 Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1176074
20 July 1994 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 368706
20 July 1994 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 647275
7 June 1994 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 647272
24 May 1994 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 367144
25 February 1991 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 342171
26 September 1989 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 332801
26 January 1988 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 320991
28 April 1987 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 315796
2 September 1986 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 311646
30 November 1985 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 519388
15 July 1985 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 303122
19 February 1985 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 300457
29 June 1984 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 457042

Deficiency record · 182

Electrical › Electrical Distribution System (service) › Wiring
Issued 23 July 2003 Resolved
Entrance to engine space - provide new alarm installation and wire improper, make permanent and proper repairs to the satisfaction of flag representative.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 August 2003
Resolution: Cleared on board, CHK
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 23 July 2003 Resolved
Numerous fire extinguishers missing throughout the vessel. replace fire extinguishers and prove proper servicing to the satisfaction of flag representative. LEGACY COMPONENT DESC: Number
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 September 2003
Resolved 28 August 2003
Resolution: Cleared on board, CHK
Electrical › Electrical Distribution System (service)
Issued 23 July 2003 Resolved
Holes in electrical panel on upper level of engine room. Make permanent and proper repairs to the satisfaction of the flag rep. LEGACY COMPONENT DESC: Circuit Breaker
Condition: Improper/Lack of Maintenance
Due 1 August 2003
Resolved 28 August 2003
Resolution: Cleared on board, CHK
Construction/Loadline › Penetrations
Issued 23 July 2003 Resolved
Holes in bulkhead for wiring from upper level engine, install proper stuffing tubes to seal and prevent chaffing. Make permanant and proper repairs to the satisfaction for flag representative.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 August 2003
Resolution: Cleared on board, CHK
Accommodation/Occupational Safety › Occupational Safety
Issued 23 July 2003 Resolved
Second bottle of C02 possibly missing actuator prove proper installation and servicing of system to satisfaction of attending USCG marine inspector. Bottles located near entrance to engine space. LEGACY COMPONENT DESC: Portable Electric Equipment/Appliances
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 August 2003
Resolution: Cleared on board, CHK
Engineering › Sea-water System (primary cooling)
Issued 23 July 2003 Resolved
Engine space - main salt water piping between the sea valves wasted and holed. Make permanant and proper repairs to the satisfaction of flag representatives. LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 August 2003
Resolution: Cleared on board, CHK
Electrical › Electric Generation Source (service)
Issued 23 July 2003 Resolved
Both generators inoperable prove proper operation same to the satisfaction of the flag representative. LEGACY COMPONENT DESC: Power Requirement
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 August 2003
Resolution: Cleared on board, CHK
Engineering › Compressed Air System (start air)
Issued 23 July 2003 Resolved
Turbo charger on both main diesel engines MDE's being serviced at the time of this inspection. Prove proper operation of both MDE's to the satisfaction of flag representative. LEGACY COMPONENT DESC: Compressor
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 August 2003
Resolution: Cleared on board, CHK
Engineering › Diesel Engine (propulsion-electric)
Issued 23 July 2003 Resolved
Starting switch and indication light improperly installed. Make permanant repairs and proper repairs to satisfaction of flag representative.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 August 2003
Resolution: Cleared on board, CHK
Electrical › Electric Generation Source (service)
Issued 23 July 2003 Resolved
Engine room. Improper wiring on the port MDE. Make permanent and proper repairs to the satisfaction of the flag representative.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 August 2003
Resolution: Cleared on board, CHK
Electrical › Electrical Distribution System (service) › Wiring
Issued 23 July 2003 Resolved
Engine space - dead end wires from bulkhead, throughout engine room (1) above port generator, (2) above fuel oil tank.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 August 2003
Resolution: Cleared on board, CHK
Fire Fighting › Means of Escape
Issued 23 July 2003 Resolved
Emergency escape hatch wasted and not weather tight. Make permanent and proper repairs to the satisfaction for Flag Representative.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 15 August 2003
Resolution: Cleared on board, CHK
Construction/Loadline › Structures
Issued 23 July 2003 Resolved
Holes wasted in overhead on the port forward side of the engine room. Make permanent and proper repairs to the satisfaction of the Flag Representative and provide gauging report of the entire overhead to the attending USCG Marine Inspector
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 August 2003
Resolution: Cleared on board, CHK
Construction/Loadline › Structures
Issued 23 July 2003 Resolved
Hole in over head in way of exhaust trunk and the stb fwd corner. Make permanent and proper repairs to the satisfaction of the Flag Representative and provide gauging report of the entire over head to the attending USCG Marine Inspector
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 August 2003
Resolution: Cleared on board, CHK
Construction/Loadline › Penetrations
Issued 23 July 2003 Resolved
Hole and dead-end pipe in the port forward corner of engine room leading into cargo holed. Make permanent and proper repairs to the satisfaction of the Flag Representative.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 August 2003
Resolution: Cleared on board, CHK
Engineering
Issued 23 July 2003 Resolved
Hole and dead-end pipe in the port forward corner of engine room leading into cargo holed. Make permanent and proper repairs to the satisfaction of the Flag Representative.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 August 2003
Resolution: Cleared on board, CHK
Fire Fighting › Fire Main
Issued 23 July 2003 Resolved
Crack in fire main under flange mounted above the ballast pump. Make permanent and proper repairs to the satisfaction of the Flag Representative. LEGACY COMPONENT DESC: Condition
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 August 2003
Resolution: Cleared on board, CHK
Accommodation/Occupational Safety › Occupational Safety
Issued 23 July 2003 Resolved
Remove propane tanks from cargo deck and install in accordance with the Code and the satisfaction of the Flag Representative. LEGACY COMPONENT DESC: Portable Electric Equipment/Appliances
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 August 2003
Resolution: Cleared on board, CHK
Engineering
Issued 23 July 2003 Resolved
Holes wasted in ballast piping under deck plate aft of ballast pump. Make permanent and proper repairs to the satisfaction of the Flag Representative.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 August 2003
Resolution: Cleared on board, CHK
Electrical › Electric Generation Source (service)
Issued 23 July 2003 Resolved
Open ports and holes in electrical panels. Make permanent and proper repairs to the satisfaction of the Flag Representative. LEGACY COMPONENT DESC: Circuit Breaker
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 August 2003
Resolution: Cleared on board, CHK
Engineering › Sea-water System (primary cooling)
Issued 23 July 2003 Resolved
Improper/leaking weld on new salt water piping. Make permanent and proper repairs to the satisfaction of the attending USCG Marine Inspector. LEGACY COMPONENT DESC: Piping
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 September 2003
Engineering › Sea-water System (primary cooling)
Issued 23 July 2003 Resolved
Saltwater return piping to both generators holes and wasted. Make permanent and proper repairs to the satisfaction of the attending USCG Marine Inspector. (02SEP03, piping repairs not correct, and brackets loose).
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 September 2003
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 23 July 2003 Resolved
Turbo on starboard main leaking oil and blowing exhaust from gaskets. Make permanent and proper repairs to the satisfaction of the attending USCG Marine Inspector (20SEP03 not leaking exhaust as bad, but oil still leaking) LEGACY COMPONENT DESC: Turbocharger
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 September 2003
Electrical › Electrical Distribution System (service) › Wiring
Issued 23 July 2003 Resolved
All plastic wire ties used for support in the overhead must be replaced with medal or plastic covered medal wire ties. Make permanent and proper repairs to the satisfaction of the attending USCG Marine Inspector
Action required: 15 - Rectify deficiencies by next port
Resolved 8 February 2024
Resolution: Vessel has not been back to the U.S no inspections since 2003. Suspected vessel has sunk no AIS updates since 2018. Changed vessel status to inactive.
Deck/Cargo › Ballast
Issued 23 July 2003 Resolved
Ballast pump piping improper. Remove plastic cap and make permanent and proper repairs to the satisfaction of the attending USCG Marine Inspector (02SEP03) Pipe repiared, pump leaking) LEGACY COMPONENT DESC: Piping
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 September 2003
Electrical › Electrical Distribution System (service)
Issued 23 July 2003 Resolved
Provide proper cover for disturbution box in galley. Make permanent and proper repairs to the satisfaction of the attending USCG Marine Inspector LEGACY COMPONENT DESC: Circuit Breaker
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 September 2003
Construction/Loadline › Structures › Superstructure
Issued 23 July 2003 Resolved
Support stanchion and knife edge to upper deck wasted, welds cracked, have Class survey and make permanent and proper repairs as needed.
Action required: 15 - Rectify deficiencies by next port
Resolved 8 February 2024
Resolution: Vessel has not been back to the U.S no inspections since 2003. Suspected vessel has sunk no AIS updates since 2018. Changed vessel status to inactive.
Electrical › Electrical Distribution System (service)
Issued 23 July 2003 Resolved
Improper wiring in steering gear compartment. Make permanent and proper repairs to the satisfaction of the attending USCG Marine Inspector LEGACY COMPONENT DESC: Wiring
Action required: 15 - Rectify deficiencies by next port
Resolved 12 September 2003
Electrical › Electrical Distribution System (service)
Issued 23 July 2003 Resolved
Improper cable run in cargo hold leading forward to fore peak. Make permanent and proper repairs to the satisfaction of the attending USCG Marine Inspector LEGACY COMPONENT DESC: Wiring
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 September 2003
Electrical › Electrical Distribution System (service)
Issued 23 July 2003 Resolved
Improper wiring in fore peak. Make permanent and proper repairs to the satisfaction of the attending USCG Marine Inspector LEGACY COMPONENT DESC: Wiring
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 September 2003
Fire Fighting › Miscellaneous Items
Issued 23 July 2003 Resolved
Improper stowage for flamable in forepeak. Forepeak not designed for flammable sotrage. lable forepeak "no flammable storage. Provide proper flammable storage for paints to satisfaction of Class. (02SEP03) locker empty but not labled, and new locker not on board. LEGACY COMPONENT DESC: Paint/Flammable Liquid Lockers
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 September 2003
Construction/Loadline › Structures
Issued 23 July 2003 Resolved
A/C on bridge not weather tight or properly mount. Make permanent and proper repairs to the satisfaction of the attending USCG Marine Inspector
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 September 2003
Construction/Loadline › Structures
Issued 23 July 2003 Resolved
Dead end wire and open holes in cabinet on bridge, open to backside of bridge Make permanent and proper repairs to the satisfaction of the attending USCG Marine Inspector LEGACY COMPONENT DESC: Superstructure
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 September 2003
Communications › Radio Communications
Issued 23 July 2003 Resolved
Hydro-static release and mount to EPIRB broken. Make permanent and proper repairs to the satisfaction of the attending USCG Marine Inspector LEGACY COMPONENT DESC: EPIRB
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 September 2003
Communications › Radio Communications
Issued 23 July 2003 Resolved
GMDSS HF/MF wired together, shut one of the other goes off. Make permanent and proper repairs to the satisfaction of the attending USCG Marine Inspector. LEGACY COMPONENT DESC: Radiotelephone Transceiver (2-27.5 MHz)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 September 2003
Construction/Loadline › Structures › Superstructure
Issued 23 July 2003 Resolved
Hard ware and cable to stay and shrouds wasted, Make permanent and proper repairs to the satisfaction of the attending USCG Marine Inspector
Action required: 15 - Rectify deficiencies by next port
Resolved 8 February 2024
Resolution: Vessel has not been back to the U.S no inspections since 2003. Suspected vessel has sunk no AIS updates since 2018. Changed vessel status to inactive.
Lifesaving › Lifebuoys
Issued 23 July 2003 Resolved
Bracket to life ring light, broke, Make permanent and proper repairs to the satisfaction of the attending USCG Marine Inspector
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 September 2003
Engineering › Bilge Water Management System
Issued 13 December 2002 Resolved
Properly repair the piping flange on the bilge piping manifold on the forward bulkhead of the engine room LEGACY COMPONENT DESC: Manifold
Action required: 17 - Rectify deficiencies prior to departure
Due 13 December 2002
Resolved 11 March 2003
Resolution: Corrected during AFE continuation on this date.
Construction/Loadline › Markings
Issued 13 December 2002 Resolved
Permanently mark the vessel's Loadline and Deck Line in accordance with the valid Loadline Certificate. LEGACY COMPONENT DESC: Load Line Mark
Action required: 17 - Rectify deficiencies prior to departure
Due 13 December 2002
Resolved 19 March 2003
Engineering › Pressure Vessel
Issued 13 December 2002 Resolved
Remove flex hose and properly repair all vital piping systems throughout engine room.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 December 2002
Resolved 19 March 2003
Engineering › Fuel Oil Service System
Issued 13 December 2002 Resolved
Properly hard pipe the fuel oil supply lines from the fuel filters on the aft engine room bulkhead to the main engines and generators (currently has flexible fuel hose running through the bilges with multiple fuel hose fittings). LEGACY COMPONENT DESC: Piping
Action required: 17 - Rectify deficiencies prior to departure
Due 13 December 2002
Resolved 11 March 2003
Resolution: Item corrected during AFE continuation.
Construction/Loadline › Structures
Issued 13 December 2002 Resolved
Properly repair the hole in the centerline bulkhead between the port and starboard aft ballast tanks. LEGACY COMPONENT DESC: Longitudinal Bulkhead
Action required: 17 - Rectify deficiencies prior to departure
Due 13 December 2002
Resolved 11 March 2003
Resolution: Item corrected during AFE continuation.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 13 December 2002 Resolved
Properly repair leaking fuel fittings on the port main engine in way of the flexible hose below the turbo charger.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 December 2002
Resolved 11 March 2003
Resolution: Item corrected during AFE continuation.
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 13 December 2002 Resolved
Replace or recharge the expended fire extinguisher on the aft engine room bulkhead. LEGACY COMPONENT DESC: Service
Action required: 17 - Rectify deficiencies prior to departure
Due 13 December 2002
Resolved 11 March 2003
Resolution: Item corrected during AFE continuation.
Engineering › Fuel Oil Storage/Transfer System
Issued 13 December 2002 Resolved
Install metallic bowls for the Racor fuel filters on the aft engine room bulkhead LEGACY COMPONENT DESC: Filter/Strainer
Action required: 17 - Rectify deficiencies prior to departure
Due 13 December 2002
Resolved 11 March 2003
Resolution: Item corrected during AFE continuation.
Construction/Loadline › Hull
Issued 13 December 2002 Resolved
Remove the doubler plate and properly repair the side shell plating on the starboard side of the engine room above the workbench. Provide flag report that repairs have been conducted to their satisfaction. LEGACY COMPONENT DESC: Hull Plating
Action required: 17 - Rectify deficiencies prior to departure
Due 13 December 2002
Resolved 19 March 2003
Electrical › Electrical Distribution System (service)
Issued 13 December 2002 Resolved
Properly dead end wires on the forward end of the starboard main engine. LEGACY COMPONENT DESC: Wiring
Action required: 17 - Rectify deficiencies prior to departure
Due 13 December 2002
Resolved 11 March 2003
Resolution: Item corrected during AEF continuation on this date.
Engineering › Fuel Oil Storage/Transfer System
Issued 13 December 2002 Resolved
Replace the rubber tubing used as sight glasses for the two oil tanks located on the starboard side of the engine room. Repair the leaks on the fill valves and remove the drip pans. Replace the section of flexible exhaust hose in the fill line for the inboard oil tank.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 December 2002
Resolved 11 March 2003
Resolution: Item corrected during AFE continuation on this date.
Electrical › Electric Supply System (service)
Issued 13 December 2002 Resolved
Properly install and cover all main engine and generator starting batteries throughout the engine room. All batteries must be in approved containers and covered. LEGACY COMPONENT DESC: Battery Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 13 December 2002
Resolved 11 March 2003
Resolution: Item corrected during AFE continuation on this date.
Engineering › Fuel Oil Service System
Issued 13 December 2002 Resolved
Properly repair the fuel oil piping (elbow) above the fuel oil day tank in the forward center of the engine room. LEGACY COMPONENT DESC: Piping
Action required: 17 - Rectify deficiencies prior to departure
Due 13 December 2002
Resolved 11 March 2003
Resolution: Item corrected during AFE continuation on this date.
Construction/Loadline › Structures
Issued 13 December 2002 Resolved
Properly repair/install handrails for the ladder leading from the main deck into the engine room.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 December 2002
Resolved 11 March 2003
Resolution: Item corrected during AFE continuation on this date.
Stability › Watertight Integrity
Issued 13 December 2002 Resolved
All wiring penetrations passing through the enclosure for the engine room access from the main deck shall be made watertight. Provide flag report that repairs have been conducted to their satisfaction.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 December 2002
Resolved 19 March 2003
Stability › Weathertight Integrity
Issued 13 December 2002 Resolved
Replace wasted cable penetration in the athwart ship passageway leading to the reefer spaces. Provide flag report that repairs have been conducted to their satisfaction.
Action required: 705 - Other - as specified
Due 13 January 2003
Resolved 19 March 2003
Electrical › Electrical Distribution System (service)
Issued 13 December 2002 Resolved
Properly install electrical output cables from the port generator to prevent a tripping hazard for the crew. LEGACY COMPONENT DESC: Wiring
Action required: 17 - Rectify deficiencies prior to departure
Due 13 December 2002
Resolved 11 March 2003
Resolution: Item corrected during AFE continuation on this date.
Electrical › Electrical Distribution System (service)
Issued 13 December 2002 Resolved
Provide blanks or properly enclose openings in all electrical panels on the forward bulkhead in the engine room. LEGACY COMPONENT DESC: Circuit Breaker
Action required: 17 - Rectify deficiencies prior to departure
Due 13 December 2002
Resolved 11 March 2003
Resolution: Item corrected during AFE continuation on this date.
Engineering › Sea-water System (primary cooling)
Issued 13 December 2002 Resolved
Properly pipe the raw water cooling line for the port generator. Provide caps for the heat exchanger tanks on all main engines and generators. LEGACY COMPONENT DESC: Piping
Action required: 17 - Rectify deficiencies prior to departure
Due 13 December 2002
Resolved 11 March 2003
Resolution: Item corrected during AFE continuation on this date.
Fire Fighting › Fixed CO2 Fire Extinguishing System
Issued 13 December 2002 Resolved
Replace the pull cable for the paint locker CO2 system. LEGACY COMPONENT DESC: Operating Controls
Action required: 17 - Rectify deficiencies prior to departure
Due 13 December 2002
Resolved 11 March 2003
Resolution: Item corrected during AFE continuation on this date.
Construction/Loadline › Structures
Issued 13 December 2002 Resolved
Remove all doubler plates and properly repair the main deck with inserts where old vent pipes had been removed in both cargo holds LEGACY COMPONENT DESC: Deck Plating
Action required: 705 - Other - as specified
Due 13 June 2003
Resolved 11 March 2003
Resolution: Item corrected during AFE continuation on this date.
Construction/Loadline › Hull
Issued 13 December 2002 Resolved
Provide flag state surveyor report addressing wastage in the aft cargo hold on the stbd side just above the cargo hold floor and the aft bulkhead - these areas appear significantly wasted and the stbd fwd area of the side shell appears to have a concrete patch along a side shell plate seams. LEGACY COMPONENT DESC: Hull Plating
Action required: 17 - Rectify deficiencies prior to departure
Due 13 December 2002
Resolved 11 March 2003
Resolution: Item corrected during AFE continuation on this date.
Construction/Loadline › Structures
Issued 13 December 2002 Resolved
Properly repair wastage in the starboard side overhead of the aft cargo hold. LEGACY COMPONENT DESC: Deck Plating
Action required: 17 - Rectify deficiencies prior to departure
Due 13 December 2002
Resolved 11 March 2003
Resolution: Item corrected during AFE continuation on this date.
Lifesaving › Lifebuoys
Issued 13 December 2002 Resolved
Replace all reflective tape on life rings throughout the vessel.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 December 2002
Resolved 11 March 2003
Resolution: Item corrected during AFE continuation on this date.
Documentation
Issued 13 December 2002 Resolved
Complete all outstanding deficiencies identified during the Coast Guard's anchorage boarding on 30 Nov 02.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 December 2002
Resolved 11 March 2003
Resolution: Item corrected during AFE continuation.
Documentation
Issued 13 December 2002 Resolved
Provide onboard vessel for USCG inspection and review ALL original certificates. The CCSSC certificate should be available onboard for examination at all times IAW CCSSC 1.15.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 December 2002
Resolved 8 April 2003
Navigation › Collision/Grounding Avoidance
Issued 13 December 2002 Resolved
Provide Code flags B, C, G, H, N and Q onboard vessel IAW CCSSC 6.3.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 December 2002
Resolved 11 March 2003
Resolution: Item corrected during AFE continuation.
Communications › Radio Communications
Issued 13 December 2002 Resolved
Provide properly operating NAVTEX IAW SOLAS (2001 Consolidated) IV/7.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 December 2002
Resolved 11 March 2003
Resolution: Item corrected during AFE continuation.
Personnel › Certificates/Documents/Licenses
Issued 13 December 2002 Resolved
Provide full crew with proper STCW 95 licenses and certificates.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 December 2002
Resolved 11 March 2003
Resolution: Item corrected during AFE continuation.
Documentation › Logs/Records
Issued 13 December 2002 Resolved
Provide the last two dry-dock reports onboard vessel.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 December 2002
Resolved 19 March 2003
Navigation › Piloting/Steering
Issued 13 December 2002 Resolved
Provide updated charts and current Notice to Mariners onboard vessel. LEGACY COMPONENT DESC: Marine Charts
Action required: 17 - Rectify deficiencies prior to departure
Due 13 December 2002
Resolved 11 March 2003
Resolution: Item corrected during AFE continuation.
Navigation › Piloting/Steering
Issued 13 December 2002 Resolved
Provide sailing directions onboard vessel for area transiting.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 December 2002
Resolved 11 March 2003
Resolution: Item corrected during AFE continuation.
Navigation › Piloting/Steering
Issued 13 December 2002 Resolved
Provide valid deviation table. LEGACY COMPONENT DESC: Magnetic Compass
Action required: 15 - Rectify deficiencies by next port
Resolved 28 August 2003
Communications › Visual Communication
Issued 13 December 2002 Resolved
Provide a properly operating daylight signaling lamp IAW SOLAS V/19.2.2.2 LEGACY COMPONENT DESC: Signalling Lamp
Action required: 17 - Rectify deficiencies prior to departure
Due 13 December 2002
Resolved 11 March 2003
Resolution: Item corrected during AFE continuation.
Communications › Radio Communications
Issued 13 December 2002 Resolved
Show proof to a Coast Guard Inspector the battery expiration date for the EPIRB and show expiration date of the hydrostatic release inside the EPIRB cabinet. LEGACY COMPONENT DESC: Emergency Source of Power
Action required: 17 - Rectify deficiencies prior to departure
Due 13 December 2002
Resolved 19 March 2003
Lifesaving › Inflatable Liferafts
Issued 13 December 2002 Resolved
Renew hydrostatic release on starboard liferaft. LEGACY COMPONENT DESC: Hydrostatic Release Unit
Action required: 17 - Rectify deficiencies prior to departure
Due 13 December 2002
Resolved 11 March 2003
Resolution: Item corrected during AFE continuation.
Lifesaving › Rescue Boat Equipment
Issued 13 December 2002 Resolved
Provide means to secure all rescue boat equipment IAW CCSSC 4.6
Action required: 17 - Rectify deficiencies prior to departure
Due 13 December 2002
Resolved 19 March 2003
Lifesaving › Lifebuoys
Issued 13 December 2002 Resolved
Provide battery or replacement bulb for port lifebuoy attached to pilothouse fwd. LEGACY COMPONENT DESC: Self-igniting Lights
Action required: 17 - Rectify deficiencies prior to departure
Due 13 December 2002
Resolved 11 March 2003
Resolution: Item corrected during AFE continuation.
Communications › Alarms/Indicators
Issued 13 December 2002 Resolved
Repair rudder angle indicator solenoid. LEGACY COMPONENT DESC: Rudder Angle Indicator
Action required: 17 - Rectify deficiencies prior to departure
Due 13 December 2002
Resolved 11 March 2003
Resolution: Item corrected during AFE continuation.
Communications
Issued 13 December 2002 Resolved
Post MMSI Number.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 December 2002
Resolved 11 March 2003
Resolution: Item corrected during AFE continuation.
Electrical › Electric Supply System (service)
Issued 13 December 2002 Resolved
Accumulator batteries on both the port and starboard side of bridge should be suitably housed and compartments used for their accommodation should be properly constructed and efficiently ventilated IAW CCSSC 2.27.9.1 LEGACY COMPONENT DESC: Battery Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 13 December 2002
Resolved 11 March 2003
Resolution: Item corrected during AFE continuation.
Accommodation/Occupational Safety › Cooking Systems
Issued 13 December 2002 Resolved
Provide report that the installed Propane gas system meets the standards of the Administration and that the system was inspected and serviced annually, by a person that is properly qualified in accordance with the requirements of the Administration. IAW CCSSC 3.21.3. LEGACY COMPONENT DESC: LPG System Requirements
Action required: 17 - Rectify deficiencies prior to departure
Due 13 December 2002
Resolved 11 March 2003
Resolution: Item corrected during AFE continuation.
Lifesaving › Hand Flares
Issued 13 December 2002 Resolved
Provide a total of six rocket parachute flares with their position plainly indicated IAW CCSSC 4.13. LEGACY COMPONENT DESC: Quantity
Action required: 17 - Rectify deficiencies prior to departure
Due 13 December 2002
Resolved 11 March 2003
Resolution: Item corrected during AFE continuation.
Documentation
Issued 13 December 2002 Resolved
Provide Flag Sate rpt attesting that all prior to dpt USCG requirements, from 30NOV02 and 13DEC02 boardings, were properly corrected and provide status rpt of # 16 and 21 found on this boarding rpt. In addition, provide Flag State report attesting that vsl is in compliance with CCSSC/ILLC.
Action required: 17 - Rectify deficiencies prior to departure
Due 13 December 2002
Resolved 11 March 2003
Resolution: Item corrected during AFE continuation.
Lifesaving › Hand Flares
Issued 13 December 2002 Resolved
Provide 6 hand flares and 4 parachute flares approved by IMO (i.e. LSA).
Action required: 17 - Rectify deficiencies prior to departure
Resolved 19 March 2003
Engineering › Fuel Oil Service System
Issued 30 November 2002 Resolved
Soft patches on salt water and fuel piping in engine room. Have flag state rep. address salt water and fuel piping in engine room. LEGACY COMPONENT DESC: Piping
Action required: 17 - Rectify deficiencies prior to departure
Due 11 March 2003
Resolved 11 March 2003
Resolution: Item corrected during AFE continuation.
Stability › Weathertight Integrity
Issued 30 November 2002 Resolved
Air condition wall units are not properly installed and are compromising water tight/weather tight integrity of vessel. Have flag state rep. address air conditioning units. LEGACY COMPONENT DESC: Air Conditioning Wall Units
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 August 2003
Construction/Loadline › Structures
Issued 30 November 2002 Resolved
Pilot house overhead deck is covered with fiberglass. Have flag state rep. address overhead pilothouse deck integrity. LEGACY COMPONENT DESC: Superstructure
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 March 2003
Resolution: Item corrected during AFE continuation.
Construction/Loadline › Structures
Issued 30 November 2002 Resolved
Bulkheads in pilothouse and throughout vessel have holes. Have flag state rep. address holes in bulkheads. LEGACY COMPONENT DESC: Longitudinal Bulkhead
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 August 2003
Documentation › Certificates/Documents
Issued 30 November 2002 Resolved
Vessel is missing CCSSC Certificate. Provide original certificate. LEGACY COMPONENT DESC: Caribbean Cargo Safety Code Certificate
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 August 2003
Construction/Loadline › Structures
Issued 30 November 2002 Resolved
Doors to accommodation spaces are wooden. Have flag state rep. address wood doors. LEGACY COMPONENT DESC: Door
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 August 2003
Construction/Loadline › Structures
Issued 29 November 2002 Resolved
Doubler plates on deck of vessel forward. Have flag state rep. address doubler plates on main deck. LEGACY COMPONENT DESC: Deck
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 August 2003
Documentation › Certificates/Documents
Issued 25 November 2002 Resolved
Provide valid COFR prior to entry to U.S. Waters LEGACY COMPONENT DESC: Certificate of Financial Responsibility
Action required: 705 - Other - as specified
Resolved 27 November 2002
Fire Fighting
Issued 7 October 2000 Resolved
Repair portable/emergency fire pump (unable to sustain continuous operationw/o handling the choke), prior to loading and departure.
Condition: Unknown
Due 25 October 2000
Resolved 25 October 2000
Engineering
Issued 7 October 2000 Resolved
Repair all torn and missing lagging for engine exhaust, prior to 20OCT00.
Condition: Unknown
Due 20 October 2000
Resolved 25 October 2000
Electrical
Issued 7 October 2000 Resolved
Replace missing covers for all circuit breaker boxes, prior to departure.
Condition: Unknown
Due 25 October 2000
Resolved 25 October 2000
Navigation
Issued 7 October 2000 Resolved
Repair leaking lube oil line supplying steering control in steering flat, prior to departure.
Condition: Unknown
Due 25 October 2000
Resolved 25 October 2000
Navigation
Issued 7 October 2000 Resolved
Remove all lube oil from steering flat on deck dur to leak, prior to departure.
Condition: Unknown
Due 25 October 2000
Resolved 25 October 2000
Fire Fighting
Issued 7 October 2000 Resolved
Update fire control plan to include "sybols legend", prior to 20OCT00.
Condition: Unknown
Due 20 October 2000
Resolved 25 October 2000
Fire Fighting
Issued 7 October 2000 Resolved
Label/identify remote pull station for engine room CO2, prior to departure.
Condition: Unknown
Due 25 October 2000
Resolved 25 October 2000
Navigation
Issued 7 October 2000 Resolved
Update all charts and light list, prior to departure.
Condition: Unknown
Due 25 October 2000
Resolved 25 October 2000
Navigation
Issued 7 October 2000 Resolved
Provide emergency steering instructions to be posted on the bridge, prior to departure.
Condition: Unknown
Due 25 October 2000
Resolved 25 October 2000
Navigation
Issued 7 October 2000 Resolved
Provide missing day shapes, Prior to departure.
Condition: Unknown
Due 25 October 2000
Resolved 25 October 2000
Fire Fighting
Issued 7 October 2000 Resolved
Provide current certification for testing e/r CO2 system, prior to loading and departure.
Condition: Unknown
Due 25 October 2000
Resolved 25 October 2000
Fire Fighting
Issued 7 October 2000 Resolved
Service fire extinguisher for rescue boat (overdue : last inspection in 1998), prior to loading and departure.
Condition: Unknown
Due 25 October 2000
Resolved 25 October 2000
Fire Fighting
Issued 7 October 2000 Resolved
Conduct fire and abandon ship drills in the presence of USCG Marine Inspector, prior to loading and departure.
Condition: Unknown
Due 25 October 2000
Resolved 25 October 2000
Unknown
Issued 7 October 2000 Resolved
Provide report resolving all deficiencies to the satisfaction of class, prior to departure.
Condition: Unknown
Due 25 October 2000
Resolved 25 October 2000
Documentation
Issued 7 October 2000 Resolved
Provide training manual for lifesaving and fire fighting, prior to departure.
Condition: Unknown
Due 25 October 2000
Resolved 25 October 2000
Documentation
Issued 7 October 2000 Resolved
Commence logging all drills & equipment maintenance for fire fighting & lifesaving.
Condition: Unknown
Due 1 December 2000
Resolved 1 December 2000
Fire Fighting
Issued 7 October 2000 Resolved
Renew all fire hoses o/b vsl, prior to loading and departure.
Condition: Unknown
Due 25 October 2000
Resolved 25 October 2000
Documentation
Issued 3 September 1999 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 3 September 1999
Resolved 3 September 1999
Documentation
Issued 3 September 1999 Resolved
Prior to 01OCT99, provide medical certificates for all crewmembers.
Condition: Unknown
Due 22 February 2000
Resolved 22 February 2000
Construction/Loadline
Issued 3 September 1999 Resolved
Prior to departure provide 2 dogs for paint locker hatch.
Condition: Unknown
Due 3 September 1999
Resolved 3 September 1999
Lifesaving
Issued 3 September 1999 Resolved
By 01OCT99, provide quick release hook for rescue boat to allow rescue boatto be released under tension(load) in accordance with LSA Code 6.1.2.2.
Condition: Unknown
Due 22 February 2000
Resolved 22 February 2000
Documentation
Issued 3 September 1999 Resolved
Prior to 01OCT99, provide stability manual that is flag state approved._x001C_ (Stability book onboard but not approved by flag).
Condition: Unknown
Due 1 October 1999
Resolved 3 September 1999
Lifesaving
Issued 3 September 1999 Resolved
Prior to 01OCT99, provide SOLAS training manual.
Condition: Unknown
Due 1 October 1999
Resolved 3 September 1999
Lifesaving
Issued 3 September 1999 Resolved
Prior to loading cargo and departure, conduct fire and abandon ship drills in the presence of the U.S. Coast Guard (with all crewmembers onboard).
Condition: Unknown
Due 3 September 1999
Resolved 3 September 1999
Navigation
Issued 3 September 1999 Resolved
Prior to arrival in next U.S. port, provide updated magnetic compass deviation table.
Condition: Unknown
Due 22 February 2000
Resolved 22 February 2000
Lifesaving
Issued 3 September 1999 Resolved
Prior to departure, re-service EPIRB battery and hydrostatic release unit.
Condition: Unknown
Due 3 September 1999
Resolved 3 September 1999
Fire Fighting
Issued 3 September 1999 Resolved
Prior to 01OCT99, provide instructions for the maintenance and operation offirefighting equipment.
Condition: Unknown
Due 22 February 2000
Resolved 22 February 2000
Deck/Cargo
Issued 3 September 1999 Resolved
Prior to departure make anchor brake operable.
Condition: Unknown
Due 3 September 1999
Resolved 3 September 1999
Lifesaving
Issued 3 September 1999 Resolved
By 01OCT99, provide powered winch motor to recover rescue boat in accordance with Lifesaving Appliance Code 6.1.1.9.
Condition: Unknown
Due 22 February 2000
Resolved 22 February 2000
Documentation
Issued 3 September 1999 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 3 September 1999
Resolved 3 September 1999
Documentation
Issued 3 September 1999 Resolved
Prior to departure provide 1 licensed GMDSS operator and prove proper operation of GMDSS equipment.
Condition: Unknown
Due 3 September 1999
Resolved 3 September 1999
Lifesaving
Issued 3 September 1999 Resolved
Prior to departure provide launching instructions for the rescue boat.
Condition: Unknown
Due 3 September 1999
Resolved 3 September 1999
Fire Fighting
Issued 3 September 1999 Resolved
Prior to loading cargo and departure, provide flag approved fire control plan.
Condition: Unknown
Due 3 September 1999
Resolved 3 September 1999
Fire Fighting
Issued 3 September 1999 Resolved
Prior to loading cargo and departure, provide annual fire extinguisher servicing report (portable and fixed systems)._x001C_ _x001C_
Condition: Unknown
Due 3 September 1999
Resolved 3 September 1999
Navigation
Issued 3 September 1999 Resolved
Prior to departure provide 1999 Tide and Current Tables (1998 currently onboard).
Condition: Unknown
Due 3 September 1999
Resolved 3 September 1999
Documentation
Issued 4 June 1998 Resolved
Prior to loading, provide Flag Administration approval of the use of the existing stability booklet while the new stability booklet is being prepared.
Condition: Unknown
Due 26 June 1998
Resolved 26 June 1998
Construction/Loadline
Issued 4 June 1998 Resolved
PRIOR TO DEPARTURE, REPLACE WASTED FORWARD HATCH COVER GASKET.
Condition: Unknown
Due 25 June 1998
Resolved 25 June 1998
Construction/Loadline
Issued 4 June 1998 Resolved
Prior to departure, make the quick acting watertight door in the galley on the main deck watertight.
Condition: Unknown
Due 26 June 1998
Resolved 26 June 1998
Electrical
Issued 4 June 1998 Resolved
Prior to departure, properly connect and secure all electrical wiring throughout the vessel. The vessel's renovations are 90% complete, with theremaining work to be done electrical. Also, a collection of dead end wiresremains in the steering lazarette and the masthead light is inoperable.
Condition: Unknown
Due 26 June 1998
Resolved 26 June 1998
Fire Fighting
Issued 4 June 1998 Resolved
Prior to loading, perform a satisfactory fire drill in the presence of a USCG Marine Inspector.
Condition: Unknown
Due 26 June 1998
Resolved 26 June 1998
Fire Fighting
Issued 4 June 1998 Resolved
PRIOR TO DEPARTURE, PROVIDE GASKET MATERIAL FOR ENGINE ROOM VENTILATION COVERS.
Condition: Unknown
Due 25 June 1998
Resolved 25 June 1998
Navigation
Issued 4 June 1998 Resolved
Prior to departure, provide an updated chart of Port Everglades, FL.
Condition: Unknown
Due 26 June 1998
Resolved 26 June 1998
Deck/Cargo
Issued 4 June 1998 Resolved
Prior to departure, repair the vessel's anchoring capstan/windlass. The capstan wedge became seperated from the capstan and key channel.
Condition: Unknown
Due 26 June 1998
Resolved 26 June 1998
Electrical
Issued 4 June 1998 Resolved
Prior to departure, replace missing machinery guards on electrical/mechanical equipment in the engine room.
Condition: Unknown
Due 26 June 1998
Resolved 26 June 1998
Lifesaving
Issued 4 June 1998 Resolved
Prior to departure, replace expired hydrostatic release on port liferaft.
Condition: Unknown
Due 26 June 1998
Resolved 26 June 1998
Construction/Loadline
Issued 4 June 1998 Resolved
Prior to loading, address and repair wasted longitudinal frames in the #2 cargo hold. Frames have been coated with epoxy and painted to hide severe holed and wasted steel.
Condition: Unknown
Due 26 June 1998
Resolved 26 June 1998
Construction/Loadline
Issued 4 June 1998 Resolved
Prior to loading, address and repair the bottom longitudinal frame on the port side of the #1 cargo hold.
Condition: Unknown
Due 26 June 1998
Resolved 26 June 1998
Fire Fighting
Issued 4 June 1998 Resolved
Prior to departure, make engine room and fiddley area above engines suitable for airtightness in event of CO2 release.
Condition: Unknown
Due 26 June 1998
Resolved 26 June 1998
Fire Fighting
Issued 4 June 1998 Resolved
Prior to loading, prove proper operation of the emergency firepump.
Condition: Unknown
Due 26 June 1998
Resolved 26 June 1998
Lifesaving
Issued 4 June 1998 Resolved
Prior to departure, provide waterlights and whistles for four additional life preservers used at watchstanding locations.
Condition: Unknown
Due 26 June 1998
Resolved 26 June 1998
Documentation
Issued 19 August 1997 Resolved
PROVIDE VALID CARIBBEAN CARGO SHIP CERTIFICATE ISSUED BY FLAG STATE.
Condition: Unknown
Due 14 July 1998
Resolved 14 July 1998
Construction/Loadline
Issued 22 July 1997 Resolved
HULL CONDITION IS THAT OF SEVERE DETERIORATION. PROVIDE CLASS CONDITION REPORT AND REPAIR PROPOSAL PRIOR TO COMPLETION OF DRY DOCK REPAIRS.
Condition: Unknown
Due 5 September 1997
Resolved 5 September 1997
Construction/Loadline
Issued 22 July 1997 Resolved
WEB FRAME FWD PEAK WASTED. REPAIR/RENEW BY 17JUL98.
Condition: Unknown
Due 5 September 1997
Resolved 5 September 1997
Navigation
Issued 22 July 1997 Resolved
NO UP TO DATE CHARTS FOR AREAS TO BE TRANSITTED ONBOARD. PROVIDE CORRECTIONS PRIOR TO ENTRY INTO NEXT U.S. PORT.
Condition: Unknown
Due 5 September 1997
Resolved 5 September 1997
Documentation
Issued 22 July 1997 Resolved
VESSEL'S ANNUAL FREIGHTSHIP EXAMINATION IS PAST DUE. SCHEDULE AND CONDUCT AN ANNUAL FREIGHTSHIP EXAMINATION WITH THE LOCAL U.S.C.G. MARINE SAFETY OFFICE PRIOR TO DEPARTURE FROM THE PORT OF JACKSONVILLE.
Condition: Unknown
Due 5 September 1997
Resolved 5 September 1997
Construction/Loadline
Issued 22 July 1997 Resolved
KNIFE EDGE ON #1 CARGO HOLD WASTED. WTD WASTED AROUND GASKETS. REPAIR/RENEW PRIOR TO 17AUG97.
Condition: Unknown
Due 5 September 1997
Resolved 5 September 1997
Navigation
Issued 22 July 1997 Resolved
NO DEVIATION TABLE ONBOARD FOR THE MAGNETIC COMPASS. PROVIDE DEVIATION TABLE PRIOR TO RETURN TO U.S. WATERS.
Condition: Unknown
Due 18 September 1997
Resolved 14 July 1998
Fire Fighting
Issued 22 July 1997 Resolved
NO FIRE CONTROL PLAN ONBOARD.
Condition: Unknown
Due 18 September 1997
Resolved 14 July 1998
Documentation
Issued 27 August 1996 Resolved
PROVIDE PROPER OFFICER LICENSES AS REQUIRED BY THE FLAG ADMINISTRATION AND THE SAFE MANNING CERTIFICATE.
Condition: Unknown
Due 28 August 1996
Resolved 19 September 1996
Unknown
Issued 27 August 1996 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 19 September 1996
Resolved 19 September 1996
Navigation
Issued 28 June 1996 Resolved
Charts 11490 & 11491 required for the safe navigation of the St. Johns River, were not corrected to date. Prior to departure provide corrected todate charts.
Condition: Unknown
Due 2 July 1996
Resolved 2 July 1996
Navigation
Issued 28 June 1996 Resolved
Vessel had no 1996 Tidal Current Table required for the safe navigation of the St. Johns River. Provide prior to departure.
Condition: Unknown
Due 2 July 1996
Resolved 2 July 1996
Documentation
Issued 28 June 1996 Resolved
Vessel did not have Minimum Manning Certificate on board, required Vessel to be manned IAW 46 U.S.C. 8301 for a vessel of her class. Vessel agent provide letter from BF Govt for minimal manning.
Condition: Unknown
Due 2 July 1996
Resolved 2 July 1996
Documentation
Issued 28 June 1996 Resolved
Vessel has no Oil Transfer Procedures, prior to next transfer in U.S. waters, provide complete OTP.
Condition: Unknown
Due 19 September 1996
Resolved 19 September 1996
Construction/Loadline
Issued 28 June 1996 Resolved
First & Second Web frames at Port side deck level and fourth Web frame at the main deck in the forward hold are wasted. Prior to departure renew/repair and provide letter from classification society on approval of repair. Class extended repair to JUL97.
Condition: Unknown
Due 19 September 1996
Resolved 19 September 1996
Lifesaving
Issued 1 April 1996 Resolved
Provide (2) additional water lights for ring life buoys.
Condition: Unknown
Due 1 April 1996
Resolved 11 April 1996
Lifesaving
Issued 1 April 1996 Resolved
Provide (2) additional ring life buoys.
Condition: Unknown
Due 1 April 1996
Resolved 11 April 1996
Lifesaving
Issued 1 April 1996 Resolved
Provide (6) orange and (6) red visual distress signals.
Condition: Unknown
Due 1 April 1996
Resolved 11 April 1996
Navigation
Issued 1 April 1996 Resolved
Provide current navigation chart for entry into Port Everglades, Fl.
Condition: Unknown
Due 1 April 1996
Resolved 11 April 1996
Fire Fighting
Issued 1 April 1996 Resolved
Prove proper operation of fire pump and hose station.
Condition: Unknown
Due 1 April 1996
Resolved 11 April 1996
Fire Fighting
Issued 1 April 1996 Resolved
Provide (5) additional size B-II fire extinguishers (1) for each stateroom.
Condition: Unknown
Due 1 April 1996
Resolved 11 April 1996
Fire Fighting
Issued 1 April 1996 Resolved
Have remaining fixed and portable fire extinguishing systems serviced.
Condition: Unknown
Due 1 April 1996
Resolved 11 April 1996
Documentation
Issued 9 May 1995 Resolved
Fax copies of medical certificates for all crew.
Condition: Unknown
Due 20 August 1995
Resolved 20 August 1995
Unknown
Issued 9 May 1995 Resolved
Correct all outstanding items required prior to departure, from boarding report dated 09MAY95.
Condition: Unknown
Due 10 May 1995
Resolved 10 May 1995
Documentation
Issued 9 May 1995 Resolved
No Shipboard Oil Pollution Emergency Plan Onboard
Condition: Unknown
Due 8 August 1995
Resolved 8 August 1995
Lifesaving
Issued 20 July 1994 Resolved
Vessel still not in compliance for personal floatation device lights and whistles as required by 46 C.F.R. 94.42-1 and -5. Must provide PFD lights and whistles for crew of seven (7).
Condition: Unknown
Due 21 July 1994
Resolved 21 July 1994
Documentation
Issued 20 July 1994 Resolved
International Oil Pollution Prevention certificate expired on 29 Jun 94.
Condition: Unknown
Due 21 July 1994
Resolved 21 July 1994
Lifesaving
Issued 24 May 1994 Resolved
WHILE ONBOARD M/V YEOCOMICO II I NOTED THAT THEIR LIFE JACKETS WERE MISSINGLIGHTS OR WHISTLES.
Condition: Unknown
Due 21 July 1994
Resolved 21 July 1994
Navigation
Issued 26 September 1989 Resolved
A VIOLATION OF 33 CFR 88.05 IN THAT VSL WAS OPERATING W/O A COPY OF THE INLAND NAVIGATION RULES ONBOARD.
Condition: Unknown
Due 26 September 1989
Resolved 26 September 1989
Documentation
Issued 26 September 1989 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 26 September 1989
Resolved 26 September 1989
Documentation
Issued 26 September 1989 Resolved
A VIOLATION OF 33 CFR 155.750 IN THAT VSL'S OIL TRANSFER PROCEDURES DID NOTCONTAIN LIST OF EACH PRODUCT TRANSFERED, PROCEDURES FOR COMMUNICATIONS, OR PROCEDURES TO ENSURE ALL VALVES ARE SECURED AFTER TRANSFER.
Condition: Unknown
Due 26 September 1989
Resolved 26 September 1989
Documentation
Issued 26 September 1989 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 24 May 1994
Resolved 25 May 1994
Documentation
Issued 28 April 1987 Resolved
VESSEL FAILED TO HAVE PROPER OIL TRANSFER PROCEDURES.
Condition: Unknown
Due 26 January 1988
Resolved 28 April 1987
Construction/Loadline
Issued 28 April 1987 Resolved
VESSEL FAILED TO HAVE A UPPER DECK MARK FOR THE LOADLINE.
Condition: Unknown
Due 26 January 1988
Resolved 28 April 1987
Documentation
Issued 28 April 1987 Resolved
VESSEL FAILED TO HAVE A VALID I.O.P.P. CERTIFICATE ONBOARD.
Condition: Unknown
Due 26 January 1988
Resolved 28 April 1987
Engineering
Issued 28 April 1987 Resolved
VESSEL FAILED TO HAVE AN OILY-WATER SEPERATOR ONBOARD.
Condition: Unknown
Due 26 January 1988
Resolved 28 April 1987
Documentation
Issued 2 September 1986 Resolved
INTERNATIONAL OIL POLLUTION PREVENTION CERTIFICATE ON BOARD WAS EXPIRED.
Condition: Unknown
Due 26 January 1988
Resolved 2 September 1986
Documentation
Issued 2 September 1986 Resolved
NO "DISCHARGE OF OIL PROHIBITED" PLACARD WAS DISPLAYED IN MACHINERY SPACES
Condition: Unknown
Due 2 September 1986
Resolved 2 September 1986
Documentation
Issued 2 September 1986 Resolved
VESSEL DID NOT HAVE A COPY OF INLAND NAVIGATION RULES ON BOARD.
Condition: Unknown
Due 2 September 1986
Resolved 2 September 1986
Documentation
Issued 19 February 1985 Resolved
VESSEL FAILED TO MAINTAIN AN OIL RECORD BOOK (33 CFR 151.25(A)).
Condition: Unknown
Due 15 July 1985
Resolved 19 February 1985
Documentation
Issued 19 February 1985 Resolved
VESSEL FAILED TO HAVE DOCUMENTATION SHOWING IT HAD BEEN SURVEYED IN ACCORDANCE WITH MARPOL 73/78 (33 CFR 151.21).
Condition: Unknown
Due 4 July 1985
Resolved 19 February 1985
Documentation
Issued 19 February 1985 Resolved
NO RADIOTELEPHONE CERTIFICATE ON BOARD.
Condition: Unknown
Due 6 March 1985
Resolved 19 February 1985

Ownership record