← All vessels
ROWAN LOUISIANA
ROWAN LOUISIANA is a mobile offshore drilling unit. The Coast Guard has recorded 84 inspections since 1983, most recently in May 2014, along with 107 deficiencies and 3 casualty investigations between 2000 and 2003.
Records from 1983 to 2014. Most recent: inspection, 12 May 2014.
- Built
- Not recorded
- Last inspected
- 12 May 2014
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 107 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 3 investigations · 2000–2003
Identity
565105
8754619 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WYU8968
228795
Flag
MARSHALL ISLANDS
338176000 (licence lapsed)
Maury page id
psix-228795
Inspections, by type
…with no type recorded27
Years with a record
29 calendar years (1983–2014)
The 84 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 12 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.
Documentation record
Tonnage as PSIX records it7106 - Regulatory (Subpart C or D), Net Ton
7222 - Regulatory (Subpart C or D), Gross Ton
7222 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
WYU8968MMSI 338176000 · expired · compulsorily equipped · granted 28 October 2004, cancelled 24 January 2015 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 84
12 May 2014
COC-MODU Renew
Type not classified · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4841890
9 May 2012
Administrative Inspection · COC-MODU Renew
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4307075
27 January 2010
Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3659041
16 March 2009
Hull Examination · MARPOL Annex VI Survey
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3434460
24 January 2009
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3399374
22 January 2009
Annual Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3432855
13 November 2008
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 3362502
26 November 2007
Annual Inspection
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3105202
11 April 2005
Internal Structural Exam
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2331458
8 December 2004
Annual Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2255631
17 September 2004
Administrative Inspection
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2198005
16 September 2004
Administrative Inspection
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2197277
9 January 2004
Administrative Inspection · Annual Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1963520
8 September 2003
Administrative Inspection
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1903389
11 May 2003
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1799240
16 March 2003
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1773993
16 January 2003
Annual Inspection · Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1727432
2 December 2002
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1718551
24 November 2002
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1726402
25 August 2002
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1688510
17 April 2002
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1629380
26 March 2002
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1597628
29 October 2001
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1401591
5 August 2001
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 24554
14 April 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1061602
31 October 2000
Damage Survey
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 823046
27 October 2000
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 72886
4 April 2000
Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1436358
21 January 2000
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 815474
16 January 2000
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1491545
4 November 1999
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1448040
30 November 1998
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 806958
26 October 1998
Deficiency Check · Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1378495
23 June 1998
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 42775
9 June 1998
Damage Survey
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1128758
13 April 1998
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1446633
31 March 1998
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1419907
5 November 1997
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1416578
20 May 1997
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1096284
28 December 1996
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 94647
9 October 1996
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1460031
16 April 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 764620
11 April 1996
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 192747
24 January 1996
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 878462
7 November 1995
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1400239
28 August 1995
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 881872
14 August 1995
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 871415
3 June 1995
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 875942
10 April 1995
Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1357162
5 January 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 683854
26 December 1994
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 5714
10 December 1994
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 149171
8 November 1994
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1469781
7 April 1994
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 857539
1 February 1994
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1162092
15 December 1993
Damage Survey · Examination of Repairs · Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1444780
7 October 1993
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1451898
5 October 1993
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 847420
13 August 1993
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 847441
5 May 1993
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1459809
8 March 1993
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1145257
9 November 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 91062
28 October 1992
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1472654
28 March 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 87156
2 February 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 129034
18 October 1991
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 942866
11 October 1991
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1248577
10 May 1991
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1212897
11 October 1990
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1235744
21 September 1990
Deficiency Check · Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1243295
12 April 1990
Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 924576
10 April 1990
Administrative
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 959773
2 November 1989
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 907743
18 October 1988
Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 887838
10 April 1988
Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1352710
16 October 1987
COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1323951
3 March 1987
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1010980
7 January 1987
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1003835
3 November 1986
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1004050
23 October 1985
COI Inspection · Credit Drydock
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1295519
15 January 1985
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 976141
27 November 1984
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1285326
12 June 1984
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1281841
11 October 1983
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1279602
Deficiency record · 107
Deck/Cargo › Cargo Transfer (solid) › General
Issued 12 May 2014
Resolved
Each crane must meet the following rated load test at both maximum and minimum boom angles usually employed in material transfers over the side of the unit. Rig could only show proof that the 5-year crane load test was conducted with only one boom angle during the test. All four cranes must be tested from 2 pulls at the required angles. 46 CFR 107.260(a) & NVIC 03-88.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 12 May 2014
Resolved
The local CO2 instructions for the generator room are incorrect which would cause confusion if need to be followed for activation. Rewrite and label the instructions properly as to avoid confusion.
Stability › Watertight Integrity › General
Issued 12 May 2014
Resolved
Numerous watertight doors were found to need adjusting to ensure proper closure. Adjust watertight doors to ensure watertight integrity prior to rig movement.
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 12 May 2014
Resolved
During the testing of the auxiliary generator's over speed device, the air cut-off flaps were not seating properly, causing the generator to not shut down. Prove proper operation of the generator air cut-off flaps on the auxiliary generator.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 12 May 2014
Resolved
The auxiliary geerator muffler was found to be holed casuing a chance of a fire/explosion hazard. Repair/replace the auxiliary generator muffler.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 12 May 2014
Resolved
The fuel oil day tank has suspect areas of wastage. Have non-destructive testing carried out to ensure the metal is a thickness that is acceptable.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 12 May 2014
Resolved
For the CO2 fixed extinguishing system, the engine shutdowns were not tested during the annual third party test. Prove proper operation of the CO2 engine shutdowns.
Engineering › Pressure Vessel › Weld
Issued 9 May 2012
Resolved
No proof of internal inspection for the pressure vessels. Have internal inspection completed by ABS or USCG MI
Lifesaving › Visual Distress Signals (General) › Storage
Issued 9 May 2012
Resolved
All lifeboat distress signals are not stored in a waterproof container. Store distress signals in a waterproof container and mark the container with distress signals or flares.
Lifesaving › Lifeboat › Self-contained Air Support System
Issued 9 May 2012
Resolved
LB #2 has an air leak within the system. Repair air leak
Lifesaving › Launching Appliances › Release Mechanism
Issued 9 May 2012
Resolved
Release gear load test on 36 man L/B has not been conducted. Complete load test
Lifesaving › Lifeboat › Self-contained Air Support System
Issued 27 November 2007
Resolved
Prove proper opetation of breathing air pressure gauge in port life boat.
Lifesaving › Buoyant Smoke Signals › General
Issued 27 November 2007
Resolved
Attach both self activating buoyant smoke signals to their respective ring buoys
Engineering › Freshwater System (intermediary cooling) › Piping
Issued 27 November 2007
Resolved
Renew S/W cooling pipes from main cooling loop to the #2 & #3 generator engine water coolers.
Communications › Alarms/Indicators › General Alarm
Issued 8 December 2004
Resolved
Provide proof of adequate audible and visual general alarm for engine room. (worklist)
Lifesaving › Inflatable Liferafts
Issued 16 January 2003
Resolved
Complete Annual servicing for #2 and #4 Liferafts.
Construction/Loadline › Hull
Issued 16 January 2003
Resolved
Issued 835 to complete the Phase II SEILOD.
Construction/Loadline
Issued 29 October 2001
Resolved
CROP AND RENEW AS NEEDED WASTED OVERHEAD LONGITUDINALS IN MUD PIT ROOM._x001C_ _x001C_ _x001C_ _x001C_
Electrical
Issued 29 October 2001
Resolved
REPLACE HOLED GENERAL ALARM BATTERY BOX.
Construction/Loadline
Issued 4 April 2000
Resolved
IN THE MOTOR ROOM PORT SIDE WHERE THE OLD WATER MAKER WAS REMOVED CROP AND RENEW WASTED DECK AREA APPROXIMATELY 24 BY 36 INCHES.
Lifesaving
Issued 4 November 1999
Resolved
Prove proper operation of the port lifeboat motor controller and limit switch. Limit switch failed to operate.
Electrical
Issued 4 November 1999
Resolved
Prove proper operation of ventilation and total rig shutdown.
Unknown
Issued 4 November 1999
Resolved
Conduct NDT of pedestal port side crane at base of brackets. A one inch crack was noted on one toe of one bracket.
Fire Fighting
Issued 26 October 1998
Resolved
HYDRO-TEST PAINT LOCKER CO2 BOTTLE.
Lifesaving
Issued 26 October 1998
Resolved
REMOUNT RING BUOY WATERLIGHT LOCATED AT #2 L/B STATION
Electrical
Issued 26 October 1998
Resolved
REMOVE TWO WIRES IN ONE THRU HOLE AND REWIRE SEPARATELY USING PROPER THRU HOLE FITTING IN MUD PIT ROOM BETWEEN WTDS
Lifesaving
Issued 26 October 1998
Resolved
INSTALL 100 PSI SAFETIES ON WATER HTR
Lifesaving
Issued 26 October 1998
Resolved
REPLACE QUICK DISCONNECTS WITH SCHRADER VALVES ON PORTABLE & SANITARY TANKS.
Electrical
Issued 26 October 1998
Resolved
REPAIR SHUTDOWN ON STANDBY GENERATOR SO SHUTDOWN CAN BE SMOOTHLY OPERATIONAL.
Lifesaving
Issued 26 October 1998
Resolved
WATERLIGHT ON LIFERING AT STBD L/R STATION NOT WORKING
Documentation
Issued 26 October 1998
Resolved
PROVIDE 3RD PARTY DOCUMENTATION ATTESTING TO RELEASE GEAR TEST ON 50 L/B, PORT & STBD LIFERAFT DAVITS.
Lifesaving
Issued 26 October 1998
Resolved
WATERLIGHT AT L/B STATION 2 NEEDS TO BE REMOUNTED
Fire Fighting
Issued 26 October 1998
Resolved
APPLICATOR AT FIRE STATION NEAR HELODECK HAS HOLE IN IT AND LEAKS EXCESSIVELY.
Electrical
Issued 26 October 1998
Resolved
EMERGENCY LIGHTING JUST OUTSIDE 3RD DECK NEAR EMERGENCY GENERATOR NOT OPERABLE.
Electrical
Issued 26 October 1998
Resolved
ENSURE THAT EMERGENCY VENTILATION SHUTDOWN OPERATES CORRECTLY.
Documentation
Issued 26 October 1998
Resolved
CONDUCT ANNUAL SURVEYS OF PORT AFT & PORT CRANES AND PROVIDE COPY OF REPORTTO [name withheld], TX
Construction/Loadline
Issued 31 March 1998
Resolved
Complete repairs to deficiences issued by ABS class surveyor, dated 31MAR98. Provide statement of fact and copy of survey report to [name withheld] when completed.
Engineering
Issued 31 March 1998
Resolved
Crop and renew as original, fuel transfer line in No.9 void tank, where pad-welded.
Construction/Loadline
Issued 31 March 1998
Resolved
Crop and renew as original, shaker pump foundation framing members and vertical frame supports on shaker tank.
Construction/Loadline
Issued 31 March 1998
Resolved
Crop and renew as original, engine room bilge eductor line where pad-welds and doubler plates are fastened.
Construction/Loadline
Issued 31 March 1998
Resolved
Conduct NDE of leg-to-can critical connections to the satisfaction of the attending marine inspector. Provide report to [name withheld].
Construction/Loadline
Issued 31 March 1998
Resolved
Make ready for inspection, master dump valve and daowell dump valve to the satisfaction of the attending marine inspector or class surveyor.
Construction/Loadline
Issued 31 March 1998
Resolved
In void No.10, on the starboard aft-bulkhead, crop and renew vertical frames 1, 2, and 4 approximately 12" up from the bottom shell plate. Gauge starboard aft bulkhead approximately 6" up from the bottom plate between vertical frames 2-3 and 4-5. Submit report to [name withheld].
Construction/Loadline
Issued 31 March 1998
Resolved
Replace missing dogs on preload tank hatches and vent closures throughout rig, as necessary.
Construction/Loadline
Issued 31 March 1998
Resolved
Grind and reweld snipe wrap around welds on stiffening bracket along main deck to jacking house truss supports G and H. Make repairs in accordance with construction portfolio.
Electrical
Issued 5 November 1997
Resolved
Conduct operational test of standby generator under load.
Lifesaving
Issued 5 November 1997
Resolved
Implement revisions to lifesaving regulations per 46 CFR 109.213(d),(e), (g), (h), and 109.301(i).
Fire Fighting
Issued 5 November 1997
Resolved
Update fire control plan to include revisions to capacity and location of lifesaving equipment. Submit to cognizant OCMI for approval.
Deck/Cargo
Issued 5 November 1997
Resolved
Repair, as original, rig cranes per ABS report/inspection, dtd 28OCT97.
Lifesaving
Issued 9 October 1996
Resolved
REPAIR GUAGES ON SELF CONTAINED BREATHING APPARATUS.
Lifesaving
Issued 9 October 1996
Resolved
TRAIN ALL PERSONNEL ON LINE THROWING APPLIANCE AND MAKE REQUIRED LOG ENTRIES.
Lifesaving
Issued 9 October 1996
Resolved
REPAIR AND CALIBRATE O2/EXPLOSIVE METERS.
Construction/Loadline
Issued 9 October 1996
Resolved
MAKE MUD PIT ROOM DOORS SEAL PROPERLY, PLUG ALL STUFFING TUBES AND REPAIR EYS/CABLE INSTALLATIONS ON MUD PUMPS.
Lifesaving
Issued 9 October 1996
Resolved
OPERATE LIFEBOATS IN THE WATER. TRAIN ALL PERSONNEL ON PROPER ABANDONMENT PROCEDURES AND LIFEBOAT OPERATIONS. LOG ACCORDINGLY.
Deck/Cargo
Issued 7 November 1995
Resolved
MAKE READY FOR INTERNAL EXAM HALLIBURTON ROOM BULK AIR TANK.
Lifesaving
Issued 7 November 1995
Resolved
REPLACE THROW-OVER TYPE LIFERAFTS WITH DAVIT LAUNCHED LIFERAFTS.
Construction/Loadline
Issued 7 November 1995
Resolved
CLEAN PAINT OFF DOGS TO WATERTIGHT HATCH BETWEEN HEAVY EQUIPMENT ROOM & HALLIBURTON ROOM.
Electrical
Issued 7 November 1995
Resolved
PROVE PROPER OPERATIONS OF LOW LUBE OIL TRIPS FOR GENERATOR UNITS #1-4.
Construction/Loadline
Issued 7 November 1995
Resolved
REPAIR & ADJUST WATERTIGHT DOOR PORTSIDE HINGES BETWEEN MUD PUMP ROOM & AIRCOMPRESSOR BULK AIR TANKS.
Lifesaving
Issued 7 November 1995
Resolved
PERFORM ANNUAL PROOF LOAD TEST ON BOTH LIFERAFT DAVIT HOOKS & FAX RESULTS TO MSO PORT ARTHUR, TEXAS.
Fire Fighting
Issued 7 November 1995
Resolved
MAKE PERMANENT REPAIRS TO LEAKING PIPING ON SALT WATER SYSTEM BY FIRE PUMPS.
Electrical
Issued 7 November 1995
Resolved
AFTER COMPLETION OF CURRENT DRILLING OPERATIONS, PROVE PROPER OPERATIONS OFTOTAL RIG SHUTDOWN.
Construction/Loadline
Issued 7 November 1995
Resolved
REPAIR & ADJUST WATERTIGHT DOOR STBDSIDE HINGES BETWEEN MUD PUMP ROOM & HEAVY EQUIPMENT ROOM.
Construction/Loadline
Issued 10 April 1995
Resolved
PERFORM GAUGING OF PRELOAD TANK NUMBER 5 IN AREA OF BOTTOM SHELL AREA AND LONGITUDINAL STIFFNERS. SUBMIT REPORT TO PATMS TO REVIEW FINDINGS.
Construction/Loadline
Issued 10 April 1995
Resolved
PERFORM HOSE TEST OF REPAIRED WELDS ON DECK IN AREA OF OIL STORAGE HATCH ONPORT SIDE.
Construction/Loadline
Issued 10 April 1995
Resolved
COMPLETE PHASE II PORTION OF SEILOD AT NEXT RIG MOVE AND PRIOR TO NEW DRILLING OPERATIONS.
Construction/Loadline
Issued 10 April 1995
Resolved
DISASSEMBLE AND MAKE READY FOR INSPECTION MUD DUMP VALVE.
Construction/Loadline
Issued 10 April 1995
Resolved
REPAIR WASTED WELDS IN WAY OF RED HAND FOUND BY PORTSIDE OIL STORAGE HATCH.
Engineering
Issued 8 November 1994
Resolved
HYDROSTATICALLY TEST FUEL TRANSFER HOSE.
Lifesaving
Issued 8 November 1994
Resolved
PROVIDE LIGHTING FOR STARBOARD LIFERAFT EMBARKATION AREA.
Electrical
Issued 7 October 1993
Resolved
INSTALL EMERGENCY LIGHTING AS PER OLD "J" 46CFR112.05-10 AND 46CFR112.15-1 AND 5.
Accommodation/Occupational Safety
Issued 7 October 1993
Resolved
MAKE AIR RECEIVER AND RELIEF VALVE ON DRILL FLOOR AVAILABLE FOR INSPECTION
Construction/Loadline
Issued 5 May 1993
Resolved
MAKE AVAILABLE VESSELS SPUD CANS FOR EXTERNAL INSPECTION OF HIGH STRESS CONNECTIONS TO LEG PRIOR TO NEXT RIG MOVE.
Electrical
Issued 28 October 1992
Resolved
REPAIR BRACKET AND REWIRE SPEAKER BY DRILLERS CONSOLE.
Deck/Cargo
Issued 28 October 1992
Resolved
CONDUCT LOAD TEST ON ALL CRANES.
Electrical
Issued 28 October 1992
Resolved
REMOVE ALL DEAD END CABLES, PROPERLY INSTALL CABLES IN COMPRESSOR ROOM.
Electrical
Issued 28 October 1992
Resolved
INSTALL EXPLOSION PROOF E-LIGHT IN MUD PIT ROOM.
Electrical
Issued 28 October 1992
Resolved
INSTALL APPROVED EXPLOSION PROOF CONNECTOR TO DOGHOUSE LIGHT SWITCH.
Electrical
Issued 28 October 1992
Resolved
REPLACE ALL BICC FITTINGS ON ARMORED CABLE WITH FITTING APPROVED FOR ARMORED CABLE.
Electrical
Issued 28 October 1992
Resolved
REPLACE ALL NON-APPROVED CABLE WITH APPROVED CABLE IN SHALE SHAKER AREA.
Electrical
Issued 28 October 1992
Resolved
REPLACE NON-APPROVED PLASTIC WIRE TIES WITH APPROVED TIES.
Documentation
Issued 11 October 1991
Resolved
SUBMIT FOR APPROVAL A REVISED FIRE CONTROL AND LIFESAVING PLAN
Documentation
Issued 21 September 1990
Resolved
IN THE PRESENCE OF A COAST GUARD INSPECTOR CONDUCT A FIRE AND ABANDON DRILL.
Electrical
Issued 21 September 1990
Resolved
PROVE PROPER OPERATION OF #2 GENERATOR REVERSE POWER RELAY.
Electrical
Issued 21 September 1990
Resolved
PRESENT FOR INSPECTION THE DRILL FLOOR AND SHALE SHAKER AREAS.
Electrical
Issued 21 September 1990
Resolved
PROVE PROPER OPERATION OF #1, 2 & 3 GENERATOR OVERSPEED TRIPS AND LOW L/O PRESSURE TRIPS.
Construction/Loadline
Issued 12 April 1990
Resolved
RENEW VERTICAL DIAGONAL TUBULAR MEMBER LOCATED IN WAY OF THE BOW LEG, CHORDB LEFTSIDE LOWEST MEMBER DUE TO 9 INCH CIRCUMFENCIAL CRACK IN BASE METAL. REPORT OF CONDITION OF MATERIAL REMOVED SHALL BE SENT TO THIS OFFICE WHEN REPAIRS COMPLETED. THIS REPAIR IS TO BE COMPLETED PRIOR TO 15OCT90.
Electrical
Issued 18 October 1988
Resolved
PROPERLY SEAL EYS FITTINGS ON MARTIN DECKER SYSTEM IN DOG HOUSE AND DRILL FLOOR MAIN POWER DISTRIBUTION PANEL NLT 18NOV88.
Electrical
Issued 7 January 1987
Resolved
DEMONSTRATE THE PROPER OPERATION OF THE OVERSPEED, LOW LUBE OIL AND REVERSECURRENT SHUTDOWNS ON ALL FOUR MAIN GENERATORS.
Electrical
Issued 7 January 1987
Resolved
DEMONSTRATE THE PROPER OPERATION OF THE LOW LUBE OIL SHUTDOWNS ON THE EMERGENCY GENERATOR.
Accommodation/Occupational Safety
Issued 7 January 1987
Resolved
DEMONSTRATE THE PROPER OPERATION OF ALL RIG AND EMERGENCY AND VENTILATION SHUTDOWNS.
Lifesaving
Issued 7 January 1987
Resolved
REPLACE DAMAGED CUTLASS BEARING AND TIGHTEN PACKING NUT ON THE RUDDER POST ON #1 CAPSULE.
Lifesaving
Issued 7 January 1987
Resolved
PROVIDE EMERGENCY LIGHTING FOR #2 CAPSULE.
Lifesaving
Issued 7 January 1987
Resolved
REPLACE THE CRACKED PORT WINDOWS ON #2 CAPSULE.
Lifesaving
Issued 7 January 1987
Resolved
MARK LIFERAFT STATIONS WITH LIFERAFT NUMBER AND CAPACITY.
Lifesaving
Issued 7 January 1987
Resolved
PROVIDE THE RIG WITH DAVIT LAUNCHED INFLATABLE LIFERAFTS OR REINSTALL THE ORIGINAL RAFTS.
Engineering
Issued 27 November 1984
Resolved
RENEW BROKEN SIGHT GLASS AND PROVIDE SUITABLE PROTECTION FOR THE SIGHT GLASS ON THE GENERATOR ROOM FUEL TANK.
Fire Fighting
Issued 27 November 1984
Resolved
PROVIDE ON BOARD THE MODU TWO OPERATIONAL OXYGEN/COMBUSTIBLE GAS INDICATORS
Documentation
Issued 27 November 1984
Resolved
PROVIDE ON BOARD THE MODU A CONSTRUCTION PORTFOLIO.
Lifesaving
Issued 27 November 1984
Resolved
PROVIDE ON BOARD THE VESSEL IN THE VICINITY OF THE CONTROL HOUSE AN AUXIL- LARY LINE FOR THE LINE THROWING APPARATUS.
Fire Fighting
Issued 27 November 1984
Resolved
PROVIDE OPERATING INSTRUCTIONS FOR THE PAINT LOCKER FIRE EXTINGUISHING SYSTEM.
Electrical
Issued 27 November 1984
Resolved
PROVIDE PROPER EYS SEALS FOR ELECTRICAL CONNECTIONS ON RENTAL EQUIPMENT IN THE MUD PIT ROOM.
Electrical
Issued 27 November 1984
Resolved
RENEW MISSING BOLTS IN THE ELECTRICAL FIXTURE PANEL IN THE MUD PIT ROOM.
Lifesaving
Issued 27 November 1984
Resolved
PROVIDE TWO SMOKE SIGNALS FOR THE 50 MAN SURVIVAL CAPSULE.
Deck/Cargo
Issued 27 November 1984
Resolved
PROVIDE EVIDENCE ANNUAL CRANE INSPECTIONS HAVE BEEN CONDUCTED.
Electrical
Issued 27 November 1984
Resolved
PROVIDE PROPER SUPPORTS FOR THE ELECTRICAL CABLE IN THE SACK ROOM.
Unknown
Issued 11 October 1983
Resolved
PROVIDE AND INSTALL LOAD CHARTS FOR ALL RIG CRANES IN THE CONTROL BOXES.
Casualty record · 3
16 January 2000Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 1491545
17 April 2002Routine · role: Involved in a Marine Casualty · 1 injured · activity 1629380
11 May 2003Routine · role: Involved in a Marine Casualty · 1 injured · activity 1799240
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.