Records from 1985 to 1995. Most recent: inspection, 7 December 1995.
Inspection history · 31
7 December 1995
Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 385667
23 August 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 382173
19 June 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 25912
10 May 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 378231
9 December 1994
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 373236
26 September 1994
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 861981
27 July 1994
Type not recorded
No type recorded · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 369314
21 June 1994
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 860577
31 May 1994
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 367124
31 May 1994
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1171812
18 February 1994
Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1164297
12 November 1993
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1466333
11 November 1993
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 85494
4 August 1993
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 359967
18 May 1992
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 480133
7 January 1992
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 496065
10 July 1991
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 486859
2 May 1991
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 343516
20 December 1990
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 513211
19 March 1990
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 335949
30 August 1989
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 530068
3 March 1989
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 328688
1 February 1989
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 328276
12 January 1989
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 473578
10 June 1988
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 323874
28 March 1988
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 322253
14 August 1987
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 449921
13 April 1987
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 315603
22 December 1986
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 523000
21 August 1986
Type not recorded
No type recorded · COTP NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 479821
13 February 1985
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 300397
Engineering
Issued 31 May 1994
Resolved
Make permanent repairs to hole in fuel tank in way of #4 D/B ballast tank
Condition: Unknown
Due 1 November 1994
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Engineering
Issued 31 May 1994
Resolved
Oily water separator was inoperable.
Condition: Unknown
Due 31 May 1994
Resolved 1 June 1994
Documentation
Issued 31 May 1994
Resolved
Vessel did not have a safe Manning Certificate. This is a violation of SOLAS 74.
Condition: Unknown
Due 1 September 1994
Resolved 1 September 1994
Deck/Cargo
Issued 12 November 1993
Resolved
Make permanent repairs to #4 double bottom fuel oil tank. Isolate #4 fuel oil tank clean and repair, by 10DEC93. Class to verify repairs. Captain to provide copy of Class report on #4 double bottom tank to [name withheld].
Condition: Unknown
Due 12 November 1993
Resolved 12 November 1993
Navigation
Issued 28 March 1988
Resolved
33CFR164.35(K) NO STEERING GEAR BLOCK DIAGRAM ON THE BRIDGE.
Condition: Unknown
Due 28 March 1988
Resolved 28 March 1988
Documentation
Issued 28 March 1988
Resolved
33CFR155.750 INCOMPLETE OIL TRANSFER PROCEDURES.
Condition: Unknown
Due 28 March 1988
Resolved 28 March 1988
Documentation
Issued 28 March 1988
Resolved
33CFR151.21(A) THE VSL DID NOT HAVE ON BOARD ANY VALID DOCUMENTATION SHOW-ING THAT IT HAD BEEN SURVEYED IAW MARPOL 73/78. THE VESSEL IS REGISTERED IN JAMAICA, A COUNTRY NOT SIGNATORY TO MARPOL 73/78.
Condition: Unknown
Due 28 March 1988
Resolved 28 March 1988
Documentation
Issued 28 March 1988
Resolved
33CFR151.25 OIL RECORD BOOK DID NOT HAVE ENTRIES FOR DISCHARGE OF OILY RESIDUE (SLUDGE).
Condition: Unknown
Due 28 March 1988
Resolved 28 March 1988
Accommodation/Occupational Safety
Issued 13 February 1985
Resolved
NO APPROVED MARINE SANITATION DEVICE ABOARD.
Condition: Unknown
Due 13 September 1985
Resolved 13 February 1985