TOP TRADER is a 2001 freight ship. The Coast Guard has recorded 17 inspections since 2001, most recently in September 2016, along with 7 deficiencies and 4 operational controls.
Records from 2001 to 2016. Most recent: inspection, 12 September 2016.
- Built
- 2001
- Last inspected
- 12 September 2016
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 7 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9216963 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
V7MX4
22884
Flag
MARSHALL ISLANDS
—
Maury page id
psix-22884
Inspections, by type
…with no type recorded5
Years with a record
8 calendar years (2001–2016)
The 17 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it30053 - Convention (Subpart B), Gross Ton
18207 - Convention (Subpart B), Net Ton
52403 - Dead Weight, Ton
60772 - Displacement, Ton
18207 - Convention (Subpart B), Net Ton
52403 - Dead Weight, Ton
60772 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 17
12 September 2016
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5999059
1 September 2016
COE-Offshore
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5989919
1 September 2016
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5989922
31 August 2016
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5988639
14 November 2015
ISPS II Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5759073
16 February 2011
NPV Safety Exam · Ballast Water Examination · ISPS I Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3946251
14 February 2011
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3942140
23 July 2008
Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3277036
21 July 2008
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3273482
20 March 2008
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3168003
20 March 2008
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3170203
12 March 2008
MARPOL Annex I Examination · ISPS II Exam · PII Safety Exam · Ballast Water Examination · MARPOL Annex V Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3158591
8 August 2006
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2740297
11 February 2003
Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1743089
3 June 2002
Annual Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1625359
22 May 2002
Security Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1619708
30 May 2001
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 290441
Deficiency record · 7
Engineering › Steam System (main) › Piping
Issued 16 February 2011
Resolved
1499 - Other (Prop. & Aux. Machinery) - PSCO observed that the engineering crew had installed a flex hose to route waste water from the boiler wash down tank directly to the sludge tank. Request clarification as to the acceptance of the temporary installation. - SOLAS 74am II/1-26 & MSC 647
Documentation › Certificates/Documents › Safety Management Certificate (ISM)
Issued 16 February 2011
Resolved
2555 - Documentation - PSCO observed that the 2nd verification endorsement on the SMC certificate was missing. Update to reflect proper endorsements. - SOLAS 74am 9/4
Documentation › Certificates/Documents › International Air Pollution Prevention Certificate
Issued 16 February 2011
Resolved
2199 - Other (MARPOL operational Def.) - PSCO observed that the Section 1.3 endorsement for the IAPP was incorrect. It was endorsed with the vessel's call sign. - MARPOL 73/78 Annex VI
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 20 March 2008
Resolved
Vessel experienced a power loss while in the COTP zone of New Orleans. See narative attached to activity #3170203 for details.
Documentation › Logs/Records › Garbage Recordkeeping
Issued 12 March 2008
Resolved
Vessel does not have a Garbage Management Plan onboard in accordance with MARPOL 2006 ANNEX V REG. 9.2 due to recent change in Owner, Operator, and Flag State. Provide documentary proof of approved Garbage Management Plan on board vessel.
Documentation
Issued 30 May 2001
Resolved
Provide International Code of Signals prior to departure.
Documentation
Issued 30 May 2001
Resolved
Have agent fax copies of missing documents.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.