WAYNE MCBRIDE is a 1974 towing vessel. The Coast Guard has recorded 18 inspections since 1993, most recently in January 2026, along with 14 deficiencies.

Records from 1993 to 2026. Most recent: inspection, 14 January 2026.

Built
1974
Last inspected
14 January 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 14 January 2026
…with no type recorded8
Operational controls None recorded without a removal date
Years with a record 13 calendar years (1993–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDH9907
228854
Flag
UNITED STATES
Maury page id
psix-228854

Documentation record

Registered dimensions (L × B × D)56.2 ft × 22.0 ft × 6.9 ft
Registered tonnagegross 74 / net 50
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSERODINO INC · GUILD, TN, UNITED STATES · built 1974
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portLOUISVILLE, KY
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 10 February 2026 · expires 28 February 2027
Service, as the file records itTowing Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it74 - Regulatory (Subpart C or D), Gross Ton
50 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1980 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 18

14 January 2026 Vessel Attendance · Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 8293782
18 September 2025 Deficiency Check
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 8236546
27 November 2024 Deficiency Check · Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 8033597
9 November 2023 Annual Inspection
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7822445
2 December 2022 Annual Inspection · Deficiency Check
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7587484
25 October 2021 Initial Certification · Deficiency Check
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 7318664
30 March 2016 Type not recorded
No type recorded · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 5844231
26 April 2013 Administration · Deficiency Check · DAPI Audit · Industry Initiated Exam · MTSA Verification
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4579247
28 March 2013 Spot Check (Safety)
Physical examination · Sector Ohio Valley · USCG Heartland District (CGD-H) · Activity 4566754
23 November 2004 MTSA Verification
Physical examination · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 2247613
17 May 2004 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 2073868
15 April 2004 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 2044722
8 February 2000 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 659198
7 December 1999 Type not recorded
No type recorded · Marine Safety Detachment Cincinnati · USCG Heartland District (CGD-H) · Activity 51395
7 December 1999 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 75875
18 January 1995 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 130190
29 September 1993 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 659197
8 September 1993 Type not recorded
No type recorded · MSO LOUISVILLE · USCG Heartland District (CGD-H) · Activity 117388

Deficiency record · 14

02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 27 November 2024 Resolved
A towing vessel must be maintained and operated so the watertight integrity and stability of the vessel are not compromised. Hull penitration at MSD overboard wasted away.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 December 2024
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 27 November 2024 Resolved
Closure devices must be provided for deckhouse or hull penetrations, which open to the exterior of the vessel and which may allow water to enter the vessel. These devices must be suitable for the expected route. No VLV at MSD overboard.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 10 December 2024
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 27 November 2024 Resolved
The master must ensure that all hatches, doors, and other openings designed to be watertight or weather-tight function properly. forward, stern port, and STBD voids holding water.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 September 2025
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 25 October 2021 Resolved
Each integral fuel tank must have a vent that connects to the highest point of the tank, discharges on a weather deck through a bend of 180 degrees, and is fitted with a 30-by-30-mesh corrosion- resistant flame screen. The fuel vents on the bow had mesh that was too large.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 December 2021
Resolved 30 December 2021
Resolution: Has been fitted with a 30-by-30-mesh corrosion- resistant flame screen.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 25 October 2021 Resolved
Each towing vessel must have a fire pump that is capable of delivering water simultaneously from the two highest hydrants, or from both branches of the fitting if the highest hydrant has a Siamese fitting, at a pitot-tube pressure of at least 344 kilopascals (kPa) (50 pounds per square inch (psi)), and a flow rate of at least 300 liters per minute(lpm) (80 gallons per minute (gpm)). The pressure coming out of one single station was not sufficient pressure.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 December 2021
Resolved 30 December 2021
Resolution: The pressure coming out of the fire stations was has sufficient pressure.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 25 October 2021 Resolved
Both the port and starboard fire stations leaked when energized. Repair/correct to stop leak.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 December 2021
Resolved 30 December 2021
Resolution: The Fire stations have been repaired/corrected NO leaks.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 25 October 2021 Resolved
Each towing vessel must be equipped with an industrial type first aid cabinet or kit, appropriate to the size of the crew and operating conditions. The first aid box in the pilot house and 2nd deck contained expired items.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 December 2021
Resolved 30 December 2021
Resolution: The first aid box in the pilot house and 2nd deck has been replaced.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 October 2021 Resolved
Pressure vessels over 5 cubic feet in volume and over 15 pounds per square inch maximum allowable working pressure (MAWP) must be equipped with one or more spring-loaded relief valves. The total relieving capacity of such relief valves must prevent pressure from exceeding the MAWP, as established by the manufacturer, by more than 10 percent. Your relief valve is within 10% of posted MAWP but we cannot confirm this is the actual manufacture MAWP. Clear off data plate to determine manufacturer MAWP.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 December 2021
Resolved 30 December 2021
Resolution: Cleared off data plate and determined manufacturer MAWP.Good to go
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Other (MARPOL Annex IV)
Issued 25 October 2021 Resolved
Each MSD must have a placard suitable for posting on which is printed the operating instructions, safety precautions, and warning pertinent to the device. The size of the letters printed on the placard much be 1/8 inch or larger. No placard was posted.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 December 2021
Resolved 30 December 2021
Resolution: MSD has a posted placard on the operating instructions, safety precautions, and warning pertinent to the device.
09 - Working and Living Conditions › 092 - Working Conditions › Obstruction/slipping, etc.
Issued 25 October 2021 Resolved
Multiple deck plates in the engine room are not properly secured and when stepped on wrong can flip up. Correct so deck plates are more secure.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 December 2021
Resolved 30 December 2021
Resolution: Multiple deck plates in the engine room have been properly secured.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 25 October 2021 Resolved
Vessel is required to carry 3 day and 3 night, or 3 combonation day/night flares. Vessel did not have any flares on board.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 December 2021
Resolved 30 December 2021
Resolution: Vessel has 3 combination day/night flares.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 October 2021 Resolved
Breaker boxes in pilothouse were missing covers. Repair/replace breaker box covers.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 December 2021
Resolved 30 December 2021
Resolution: Repaired/replaced breaker box covers.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 25 October 2021 Resolved
Captain did not have a Marine Operators Permit.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 December 2021
Resolved 30 December 2021
Resolution: Captain has a Marine Operators Permit.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 25 October 2021 Resolved
Vessel has cloth coverings for ventilation covers around the funnels. Replace covers with adequate fire-retardant materials (not cloth) on funnels as well as ventilation opening between stacks.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 January 2022
Resolved 25 January 2022
Resolution: Covers with adequate fire-retardant materials on funnels as well as ventilation opening between stacks have been installed.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.