Records from 1985 to 2012. Most recent: inspection, 23 July 2012.
Inspection history · 61
23 July 2012
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4388161
10 July 2012
DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4374286
9 January 2012
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4221572
2 July 2009
Administrative Inspection · Hull Examination · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3521156
1 July 2008
Annual Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3254547
24 April 2007
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2944559
19 April 2006
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2597032
26 April 2005
Periodic Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2347549
4 May 2004
Periodic Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2058706
8 March 2004
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2020379
18 September 2003
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2269917
14 July 2003
Damage Survey
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1846988
13 July 2003
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1852628
29 April 2003
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1782534
6 March 2002
Hull Examination · Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1491804
12 April 2001
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1423544
26 April 2000
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1461296
16 August 1999
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 777691
25 March 1999
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1120241
8 February 1999
Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 794480
12 May 1998
Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1125035
15 April 1998
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1383859
2 March 1998
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 782215
12 September 1997
Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 787130
3 July 1996
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 761021
1 July 1996
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 12939
1 July 1996
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 206976
7 March 1996
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 885405
10 January 1996
Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 885751
18 October 1995
Re-Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1190310
18 November 1994
Damage Survey
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 835159
13 November 1994
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 82141
13 November 1994
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 116220
18 October 1994
COI Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1143871
6 September 1994
Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 836809
12 July 1994
Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1356725
11 July 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 4929
11 July 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 866222
23 August 1993
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 849062
15 July 1993
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1152808
29 May 1992
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1269487
6 August 1990
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 914355
16 July 1990
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1215671
15 June 1990
Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1227174
6 June 1990
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1226186
4 April 1990
Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1212128
21 July 1989
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1279462
12 June 1989
Hull Examination
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1339941
6 June 1989
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1205140
18 April 1989
Drydock Extension
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1033460
14 July 1988
Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 897989
19 May 1988
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1194902
14 September 1987
Administrative
Administrative · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1313188
4 August 1987
Re-Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1028026
7 August 1986
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 998200
5 June 1986
COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 988632
18 November 1985
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 997990
18 October 1985
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 989886
2 August 1985
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1290575
23 July 1985
Deficiency Check
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 981005
18 April 1985
Type not recorded
No type recorded · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 980064
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 10 July 2012
Resolved
Life ring buoys (03) need new retro-reflective tape (SOLAS).
Action required: 705 - Other - as specified
Due 24 July 2012
Resolved 23 July 2012
Resolution: Received e-mail with receipt and pictures verifying above deficiency''s correction.
Electrical › Electric Supply System (service) › Battery Conductor
Issued 10 July 2012
Resolved
Remove wing nut from main engine start battery and replace welding cable running off terminal.
Action required: 705 - Other - as specified
Due 24 July 2012
Resolved 23 July 2012
Resolution: Received e-mail with receipt and pictures verifying above deficiency''s correction.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 10 July 2012
Resolved
Replace alcohol test kits 06 total which expired last month.
Action required: 705 - Other - as specified
Due 24 July 2012
Resolved 23 July 2012
Resolution: Received e-mail with receipt and pictures verifying above deficiency''s correction.
Communications › Radio Communications › VHF Radiotelephone
Issued 2 July 2009
Resolved
Obtain FCC Saftey Certificate for radio.
Condition: Improper/Lack of Maintenance
Due 15 August 2009
Resolved 24 August 2009
Resolution: FCC Safety inspection conducted and certificate placed onboard.
Lifesaving › Hand Flares › Quantity
Issued 2 July 2009
Resolved
Procure and place onboard 2 red or orange flares.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 July 2009
Resolution: 2 red flares placed onboard.
Communications › Radio Communications › VHF Radiotelephone
Issued 2 July 2009
Resolved
Obtain emergency broadcast placard.
Condition: Improper Installation
Due 15 August 2009
Resolved 24 August 2009
Resolution: Placard obtained and mounted in a conspicuous location.
Engineering › Steering Gear System › Hydraulic Hose
Issued 2 July 2009
Resolved
Replace hydraulic lines for steering gears.
Condition: Improper/Lack of Maintenance
Due 15 August 2009
Resolved 14 August 2009
Resolution: Hydraulic lines replaced with the approved J1942 hoses.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 2 July 2009
Resolved
Procure 6 Type 1 lifejackets and lable with name of the vessel.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 July 2009
Resolution: 6 Type 1 lifejackets placed onboard and labled.
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 2 July 2009
Resolved
Provide method to secure ventilation during an engine room fire.
Condition: Placed in Improper Service
Due 15 August 2009
Resolved 14 August 2009
Resolution: Closure installed to secure ventilation in the event of a engine room fire.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 2 July 2009
Resolved
Replace emergency lighting fixture (forward).
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 July 2009
Resolution: Lighting fixture replaced.
Lifesaving › Line-Throwing Appliances › Lines
Issued 1 July 2008
Resolved
Vessel does not currently have UV resistent line attached to the life ring. Replace w/ CG approved 60' line on each ring buoy.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 July 2008
Resolved 1 July 2008
Resolution: Vessel owner placed CG approved UV floatable line on each ring buoy.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 24 April 2007
Resolved
Eyewash and aspirin were expired. Discard expired items and replace with up to date ones.
Action required: 705 - Other - as specified
Due 24 May 2007
Resolved 7 May 2007
Resolution: Rcvd picture of eyewash and aspirin along with receipt from Walgreens of purchase.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 24 April 2007
Resolved
Required to have onboard drug/alcohol test kit.
Action required: 705 - Other - as specified
Due 24 May 2007
Resolved 7 May 2007
Resolution: Rcvd in the mail, picture of alcohol screen test kit and receipt for 2 kits.
Accommodation/Occupational Safety › Cooking Systems › Cooking Fuel
Issued 24 April 2007
Resolved
Stove is no longer in use. All gas lines have been removed. Remove propane tanks from vessel.
Action required: 705 - Other - as specified
Due 24 May 2007
Resolved 7 May 2007
Resolution: Rcvd in the mail picture of empty propane tank closet showing removal of tanks.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 24 April 2007
Resolved
Light on ring buoy not working, repair.
Action required: 705 - Other - as specified
Due 19 May 2007
Resolved 7 May 2007
Resolution: Rcvd in mail receipt from Ace hardware for purchase of 6v battery for floatlite for life ring.
Communications › Radio Communications › VHF Radiotelephone
Issued 19 April 2006
Resolved
Provide proof of valid FCC safety certificate.
Due 19 May 2006
Resolved 12 May 2006
Resolution: recieved fax copy of saftey cert.
Communications › Radio Communications › VHF Radiotelephone
Issued 19 April 2006
Resolved
Provide proof of valid radio operator's permit.
Due 19 May 2006
Resolved 5 May 2006
Resolution: New permit, faxed
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 19 April 2006
Resolved
Provide current US Coast Pilot.
Due 19 May 2006
Resolved 5 May 2006
Resolution: new coast pilot
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 19 April 2006
Resolved
Show proof of enrollment to CG approved drug program.
Action required: 701 - Prior to carriage of passengers/cargo
Due 19 April 2006
Resolved 12 May 2006
Resolution: faxed proof
Electrical › Electric Generation Source (service) › Power Requirement
Issued 19 April 2006
Resolved
Secure batter box for the generator.
Due 19 May 2006
Resolved 5 May 2006
Resolution: Secured
Construction/Loadline › Hull › Bottom Plating
Issued 14 July 2003
Resolved
Affect temporary repair to damage in collision bulkhead and cracked longitudinal stiffener w/ steel box constructed of at least 3/16 in plate as described by marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 March 2004
Construction/Loadline › Hull › Bottom Plating
Issued 14 July 2003
Resolved
Haul out vsl to affect repairs itemized in 835 worklist; please note that the items listed are not all inclusive and are subject to further inspection of hull after vsl is hauled out.
Due 31 December 2003
Resolved 8 March 2004
Engineering › Bilge Water Management System
Issued 29 April 2003
Resolved
RENEW STRAINER ON BILGE SUCTION IN AFT COMPARTMENT.
Action required: 705 - Other - as specified
Due 31 May 2003
Resolved 7 May 2003
Lifesaving › Hand Flares
Issued 6 March 2002
Resolved
PROVIDE THREE FLARES. ITEM TO BE COMPLETED PRIOR TO CARRYING PASSENGERS AND 03 MAY 02.
Due 2 May 2002
Resolved 3 May 2002
Operations/Management › Drug and Alcohol Testing
Issued 6 March 2002
Resolved
PROVIDE PROOF OF ENROLLMENT IN A DRUG TESTING PROGRAM. ITEM TO BE COMPLETED PRIOR TO CARRYING PASSENGERS AND 03 MAY 02. LEGACY COMPONENT DESC: Proof of Enrollment
Due 3 May 2002
Resolved 3 May 2002
Lifesaving › Line-Throwing Appliances
Issued 6 March 2002
Resolved
PROVIDE 60' OF LINE FOR RING BUOY AND ATTACH LIGHT TO BUOY. ITEM TO BE COMPLETED PRIOR TO CARRYING PASSENGERS AND 03 MAY 02. LEGACY COMPONENT DESC: Lines
Due 3 May 2002
Resolved 3 May 2002
Construction/Loadline
Issued 12 April 2001
Resolved
PROVIDE HIGH WATER BILGE ALARM IN ENGINE ROOM.
Condition: Unknown
Due 12 May 2001
Resolved 23 April 2001
Lifesaving
Issued 12 April 2001
Resolved
REPAIR OR REPLACE RING BUOYS PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 12 May 2001
Resolved 23 April 2001
Engineering
Issued 26 April 2000
Resolved
PROVIDE FLAME SHIELD ON RACOR FUEL FILTER.
Condition: Unknown
Due 26 April 2000
Resolved 26 April 2000
Accommodation/Occupational Safety
Issued 26 April 2000
Resolved
REPAIR STAIR CENTER HAND RAIL AT WELD.
Condition: Unknown
Due 26 April 2000
Resolved 26 April 2000
Lifesaving
Issued 26 April 2000
Resolved
POST SIGN AT STAIRS FOR MAX PERSONS ON 2ND DK.
Condition: Unknown
Due 26 April 2000
Resolved 26 April 2000
Electrical
Issued 26 April 2000
Resolved
REPAIR TOP OF GEN BATTERY BOX.
Condition: Unknown
Due 26 April 2000
Resolved 26 April 2000
Documentation
Issued 26 April 2000
Resolved
PROVIDE PROOF OF DRUG TESTING PROGRAM.
Condition: Unknown
Due 26 May 2000
Resolved 22 June 2000
Fire Fighting
Issued 26 April 2000
Resolved
SERVICE B-1 FIRE EXT ON BRIDGE.
Condition: Unknown
Due 26 May 2000
Resolved 22 June 2000
Lifesaving
Issued 26 April 2000
Resolved
LABLE LIFE PRESERVER STORAGE.
Condition: Unknown
Due 24 May 2000
Resolved 22 June 2000
Lifesaving
Issued 26 April 2000
Resolved
PROVIDE REFLECTIVE TAPE ON BOTH SIDES OF EXTRA RING BUOYS.
Condition: Unknown
Due 24 May 2000
Resolved 22 June 2000
Documentation
Issued 16 August 1999
Resolved
OBTAIN FCC OPERATORS LIC AND RADIO SAFETY CERTIFICATE.
Condition: Unknown
Due 16 August 1999
Resolved 16 August 1999
Lifesaving
Issued 25 March 1999
Resolved
PROVIDE 13 TYPE 1 ADULT LIFE PRESERVERS.
Condition: Unknown
Due 25 March 1999
Resolved 25 March 1999
Lifesaving
Issued 25 March 1999
Resolved
PROVIDE BUOYANT LINE ON RING BUOY.
Condition: Unknown
Due 25 March 1999
Resolved 25 March 1999
Lifesaving
Issued 25 March 1999
Resolved
PROVIDE NON-SHARP BOAT HOOK FOR MAN OVER BOARD RETRIVAL.
Condition: Unknown
Due 25 March 1999
Resolved 25 March 1999
Electrical
Issued 25 March 1999
Resolved
LINE GENERATOR BATTERY BOX WITH ACID RESISTANT MATERIAL.
Condition: Unknown
Due 25 March 1999
Resolved 25 March 1999
Unknown
Issued 25 March 1999
Resolved
INSTALL GUARD ON BELT PULLY ON MAIN ENG.
Condition: Unknown
Due 25 March 1999
Resolved 25 March 1999
Fire Fighting
Issued 25 March 1999
Resolved
PROVIDE MARKING ON FIXED FIRE EXTUISHER PULL STATION.
Condition: Unknown
Due 25 March 1999
Resolved 25 March 1999
Documentation
Issued 25 March 1999
Resolved
OBTAIN FCC OPERSTORS LIC AND RADIO SAFETY CERTIFICATE.
Condition: Unknown
Due 25 March 1999
Resolved 25 March 1999
Documentation
Issued 18 October 1995
Resolved
LABEL FREEBOARD MARKS, PORT AND STARBOARD AS STATED IN VESSELS STABILITY LETTER.
Condition: Unknown
Due 29 February 1996
Resolved 29 February 1996
Lifesaving
Issued 18 October 1995
Resolved
LABEL UPPER DECK WITH 30 PERSONS MAXIMUM.
Condition: Unknown
Due 29 February 1996
Resolved 29 February 1996
Construction/Loadline
Issued 18 October 1994
Resolved
Label for peak hatch.
Condition: Unknown
Due 12 December 1994
Resolved 12 December 1994
Construction/Loadline
Issued 18 October 1994
Resolved
Label vsls name and home port on stern.
Condition: Unknown
Due 12 December 1994
Resolved 12 December 1994
Fire Fighting
Issued 18 October 1994
Resolved
Prove operation of fire pump, install metallic nozzle and label fire station.
Condition: Unknown
Due 12 December 1994
Resolved 12 December 1994
Fire Fighting
Issued 18 October 1994
Resolved
Mount 1 fire extinguisher in engine room.
Condition: Unknown
Due 12 December 1994
Resolved 12 December 1994
Navigation
Issued 18 October 1994
Resolved
Secure air compressor.
Condition: Unknown
Due 12 December 1994
Resolved 12 December 1994
Engineering
Issued 18 October 1994
Resolved
Label emergency fuel shutoff.
Condition: Unknown
Due 13 December 1994
Resolved 13 December 1994
Accommodation/Occupational Safety
Issued 18 October 1994
Resolved
Label propane on propane box and install vave to shutoff flow from near galley area. Valve must be located outside space.
Condition: Unknown
Due 12 December 1994
Resolved 12 December 1994
Construction/Loadline
Issued 6 September 1994
Resolved
Install check valves on all bilge suction branch lines.
Condition: Unknown
Due 12 December 1994
Resolved 12 December 1994
Electrical
Issued 6 September 1994
Resolved
Label all E-lights in grand lounge.
Condition: Unknown
Due 6 September 1994
Resolved 6 September 1994
Construction/Loadline
Issued 6 September 1994
Resolved
Crop and insert approximately 24" x 18" section of hull plate port starboard forward as marked.
Condition: Unknown
Due 12 December 1994
Resolved 12 December 1994
Electrical
Issued 6 September 1994
Resolved
Replace burned out emergency light bulb aft Grande lounge port exit.
Condition: Unknown
Due 6 September 1994
Resolved 6 September 1994
Electrical
Issued 6 September 1994
Resolved
Remove all wire nuts and solid core wire in galley area. Mechanically connect all splices.
Condition: Unknown
Due 12 December 1994
Resolved 12 December 1994
Construction/Loadline
Issued 12 July 1994
Resolved
MAKE PERMANENT REPAIRS TO UPPER PASSENGER DECK. DAMAGE IS LOCALIZED AT TWOSEPARATE AREAS ON THE PORT SIDE. ALL DAMAGE IS OUTSIDE PASSENGER SAFETY GAURD RAILS.
Condition: Unknown
Due 12 July 1994
Resolved 12 July 1994
Documentation
Issued 15 July 1993
Resolved
Mark hull with minimum freeboard marks per the vessel stability letter not later than the compliance date.
Condition: Unknown
Due 15 July 1993
Resolved 15 July 1993
Documentation
Issued 15 July 1993
Resolved
Provide letters for senior deckhands not later than the compliance date.
Condition: Unknown
Due 15 July 1993
Resolved 15 July 1993
Accommodation/Occupational Safety
Issued 15 July 1993
Resolved
Replace cracked glass in the forward starboard side entrance door not laterthan the compliance date.
Condition: Unknown
Due 15 July 1993
Resolved 15 July 1993
Lifesaving
Issued 15 July 1993
Resolved
Provide three visual distress signal flares for day time use not later thanthe compliance date.
Condition: Unknown
Due 15 July 1993
Resolved 15 July 1993
Electrical
Issued 15 July 1993
Resolved
Install properly wired generator starting switch not later than the compliance date.
Condition: Unknown
Due 15 July 1993
Resolved 15 July 1993
Unknown
Issued 15 July 1993
Resolved
Provide evidence of compliance with D.O.T. drug testing regulations per_x001C_ 46 CFR, Part 16 not later than the compliance date.
Condition: Unknown
Due 15 July 1993
Resolved 15 July 1993
Engineering
Issued 15 July 1993
Resolved
Provide engine exhaust lagging as necessary not later than the compliance date.
Condition: Unknown
Due 15 July 1993
Resolved 15 July 1993
Electrical
Issued 15 July 1993
Resolved
Provide light globe for the port bow overhead light not later than the compliance date
Condition: Unknown
Due 15 July 1993
Resolved 15 July 1993
Lifesaving
Issued 15 July 1993
Resolved
Provide separate stowage for children and adult life preservers not later than the compliance date.
Condition: Unknown
Due 15 July 1993
Resolved 15 July 1993
Unknown
Issued 15 July 1993
Resolved
Bolt down or secure small air compressor located under the pilothouse not later than the compliance date.
Condition: Unknown
Due 15 July 1993
Resolved 15 July 1993
Documentation
Issued 15 July 1993
Resolved
Provide evidence of vessel documentation not later than the compliance date.
Condition: Unknown
Due 15 July 1993
Resolved 15 July 1993
Deck/Cargo
Issued 15 July 1993
Resolved
Replace deteriorated anchor line with line of suitable length and size not later than the compliance date.
Condition: Unknown
Due 15 July 1993
Resolved 15 July 1993
Engineering
Issued 15 July 1993
Resolved
Provide belt guards for the main engine and generator not later than the compliance date.
Condition: Unknown
Due 15 July 1993
Resolved 15 July 1993
Engineering
Issued 29 May 1992
Resolved
Provide valves at keel cooler shell connections or raise piping above waterline prior to use of fexible hose, but not later than the compliance date.
Condition: Unknown
Due 29 May 1992
Resolved 29 May 1992
Unknown
Issued 6 June 1990
Resolved
PUT THE VESSEL'S NAME AND HAIL PORT ON THE STERN OF THE VESSEL ( 4 INCH LETTERS MIN.)
Condition: Unknown
Due 6 June 1990
Resolved 6 June 1990
Lifesaving
Issued 6 June 1990
Resolved
RELOCATE A TOTAL OF 80 ADULT PFD'S TO THE UPPER DECK AND STORE IN AN AREA THAT WILL ALLOW THE PFD'S TO FLOAT FREE.
Condition: Unknown
Due 6 June 1990
Resolved 6 June 1990
Lifesaving
Issued 6 June 1990
Resolved
PROVIDE FOUR(4) ADDITIONAL ADULT PFD'S.
Condition: Unknown
Due 6 June 1990
Resolved 6 June 1990
Lifesaving
Issued 6 June 1990
Resolved
PROVIDE 2 ADDITIONAL RED FLARES.
Condition: Unknown
Due 6 June 1990
Resolved 6 June 1990
Fire Fighting
Issued 6 June 1990
Resolved
PROVIDE AND INSTALL APPROVED FIRE EXTINGUISHER HOLDERS FOR ALL PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 6 June 1990
Resolved 6 June 1990
Documentation
Issued 6 June 1989
Resolved
PLACE CERTFICATE OF DOCUMENTATION ON BOARD VESSSEL.
Condition: Unknown
Due 6 June 1989
Resolved 6 June 1989
Lifesaving
Issued 6 June 1989
Resolved
PROVIDE 3 ORANGE SMOKE FLARES.
Condition: Unknown
Due 6 June 1989
Resolved 6 June 1989
Lifesaving
Issued 6 June 1989
Resolved
PROVIDE WATERIGHT CONTAINER FOR CG APPROVED FLARES.
Condition: Unknown
Due 6 June 1989
Resolved 6 June 1989
Accommodation/Occupational Safety
Issued 6 June 1989
Resolved
ENGINE COMPARTMENT VENTILATION DUCT SHALL EXTEND TO NEAR BOTTOM.
Condition: Unknown
Due 6 June 1989
Resolved 6 June 1989
Lifesaving
Issued 6 June 1989
Resolved
PLACE NAME OF VESSEL ON SIX CHILD PFDS.
Condition: Unknown
Due 6 June 1989
Resolved 6 June 1989
Lifesaving
Issued 6 June 1989
Resolved
PLACE VESSELS NAME ON RING BOUY.
Condition: Unknown
Due 6 June 1989
Resolved 6 June 1989
Lifesaving
Issued 6 June 1989
Resolved
PROVIDE TWO RED FLARES.
Condition: Unknown
Due 6 June 1989
Resolved 6 June 1989
Engineering
Issued 19 May 1988
Resolved
PROVIDE PERMANENT SUPPORT BRACKET FOR REMOTE FUEL SHUT-OFFS AND DIRECTIONS ON LABEL INDICATING METHOD TO SHUT-OFF NOT LATER THAN 01JUN88.
Condition: Unknown
Due 19 May 1988
Resolved 19 May 1988
Lifesaving
Issued 19 May 1988
Resolved
PROVIDE 60 FOOT OF LINE FOR ATTACHMENT TO THE LIFE RING BOUY.
Condition: Unknown
Due 19 May 1988
Resolved 19 May 1988
Navigation
Issued 19 May 1988
Resolved
PROVIDE SUPPORT FOR HYDRAULIC HOSE BLACK VALUE ON PORT SIDE IN STERN COMPARTMENT (DO NOT USE PVC PIPE).
Condition: Unknown
Due 19 May 1988
Resolved 19 May 1988
Electrical
Issued 19 May 1988
Resolved
PACK STUFFING TUBES FOR ELECTRICAL CABLE PENETRATIONS THROUGH WATERTIGHT BULKHEADS THROUGHOUT VESSEL.
Condition: Unknown
Due 19 May 1988
Resolved 19 May 1988
Construction/Loadline
Issued 19 May 1988
Resolved
EFFECT PERMANENT REPAIRS TO A 3/4 INCH HOLE DRILLED IN AFTER ENGINE ROOM BULKHEAD (LOCATION 6 INCHES BELOW OVERHEAD APPROXIMATELY 6 FOOT INBOARD OF PORT SIDE SHELL.
Condition: Unknown
Due 19 May 1988
Resolved 19 May 1988
Navigation
Issued 19 May 1988
Resolved
RENEW INLET HYDRAULIC SUPPLY HOSE TO STARBOARD PADDLE WHEEL.
Condition: Unknown
Due 19 May 1988
Resolved 19 May 1988
Deck/Cargo
Issued 19 May 1988
Resolved
PROVIDE SAFETY HOOK IN LIEU OF OPEN HOOK ON FORWARD ACCOMODATION RAMP.
Condition: Unknown
Due 19 May 1988
Resolved 19 May 1988
Electrical
Issued 19 May 1988
Resolved
RESECURE COVER TO GENERATOR CONTROL CONSOLE NOT LATER THAN 01JUN88.
Condition: Unknown
Due 19 May 1988
Resolved 19 May 1988
Navigation
Issued 19 May 1988
Resolved
PROVIDE SIDE LIGHTS SCREENS AS PER NAVIGATION RULES.
Condition: Unknown
Due 19 May 1988
Resolved 19 May 1988
Accommodation/Occupational Safety
Issued 19 May 1988
Resolved
PROVIDE PERMANENT RIGID SUPPORT FOR HYDROPNEUMATIC TANK (AIR CUSHION) MOUNTED ON POTABLE WATER TANK.
Condition: Unknown
Due 19 May 1988
Resolved 19 May 1988
Lifesaving
Issued 19 May 1988
Resolved
PROVIDE HAND-HELD PYROTECHNIC DISTRESS SIGNALS AS REQUIRED BY 46CFR180.35; ALSO PROVIDE SUITABLE WATER TIGHT CONTAINER FOR SIGNALS.
Condition: Unknown
Due 19 May 1988
Resolved 19 May 1988
Lifesaving
Issued 19 May 1988
Resolved
PROVIDE MARKINGS TO INDICATE STOWAGE LOCATION FOR THE CHILD LIFE JACKETS ONUPPER PASSENGER DECK.
Condition: Unknown
Due 19 May 1988
Resolved 19 May 1988
Navigation
Issued 19 May 1988
Resolved
PROVIDE EFFECTIVE FASTENINGS FOR THE FLEXIBLE HYDRAULIC HOSES AT THE FOLLOWING LOCATIONS: ENGINE ROOM-PORT SIDE AFT/NO. 3 COMPT. STB SIDE FWD.
Condition: Unknown
Due 19 May 1988
Resolved 19 May 1988
Fire Fighting
Issued 4 August 1987
Resolved
PROVIDE TWO ADDITIONAL B-II FIRE EXTINGUISHERS.
Condition: Unknown
Due 4 August 1987
Resolved 4 August 1987
Construction/Loadline
Issued 4 August 1987
Resolved
REISTALL HATCH COVER IN WATERTIGHT BULKHEAD BETWEEN THE THIRD AND FOURTH COMPARTMENT.
Condition: Unknown
Due 4 August 1987
Resolved 4 August 1987
Lifesaving
Issued 4 August 1987
Resolved
PROVIDE ONE RING BUOY.
Condition: Unknown
Due 4 August 1987
Resolved 4 August 1987
Engineering
Issued 4 August 1987
Resolved
PROVIDE VENTILATION DUCTING FOR ENGINE COMPARTMENT AS PER 46CFR182.20-45.
Condition: Unknown
Due 4 August 1987
Resolved 4 August 1987
Navigation
Issued 4 August 1987
Resolved
MOVE SIDE RUNNING LIGHTS SO THEY ARE NOT BLOCKED.
Condition: Unknown
Due 4 August 1987
Resolved 4 August 1987
Navigation
Issued 4 August 1987
Resolved
REPAIR MASTHEAD LIGHT.
Condition: Unknown
Due 4 August 1987
Resolved 4 August 1987
Engineering
Issued 4 August 1987
Resolved
LABEL BILGE MANIFOLD.
Condition: Unknown
Due 4 August 1987
Resolved 4 August 1987
Electrical
Issued 4 August 1987
Resolved
INSTALL BATTERY COVERS.
Condition: Unknown
Due 4 August 1987
Resolved 4 August 1987
Electrical
Issued 4 August 1987
Resolved
REPAIR BARE WIRES UNDER CONSOLE IN PILOT HOUSE.
Condition: Unknown
Due 4 August 1987
Resolved 4 August 1987
Lifesaving
Issued 4 August 1987
Resolved
PROVIDE ONE ADDITIONAL CHILD SIZE PFD.
Condition: Unknown
Due 4 August 1987
Resolved 4 August 1987
Engineering
Issued 4 August 1987
Resolved
LABEL FUEL SHUT OFF (1 INCH LETTERS)
Condition: Unknown
Due 4 August 1987
Resolved 4 August 1987
Construction/Loadline
Issued 5 June 1986
Resolved
CLEAN ENGINEROOM BILGES AND REMOVE WATER FROM FORPEAK COMPARTMENT.
Condition: Unknown
Due 5 June 1986
Resolved 5 June 1986
Construction/Loadline
Issued 18 November 1985
Resolved
INSTALL 57 CUBIC FEET OF FOAM FLOTATION MATERIAL IN THE LAZARETTE IN ACCORDANCE WITH 46 CFR 170.245. PLANS FOR INSTALLATION TO BE SUBMITTED TO [name withheld].
Condition: Unknown
Due 18 November 1985
Resolved 18 November 1985
Lifesaving
Issued 18 April 1985
Resolved
REPAIR OR REPLACE WATER LIGHT.
Condition: Unknown
Due 18 April 1985
Resolved 18 April 1985
Lifesaving
Issued 18 April 1985
Resolved
REMOVE LOCK FROM COMPARTMENT CONTAING LIFE PRESERVERS ON THE UPPER DECK.
Condition: Unknown
Due 18 April 1985
Resolved 18 April 1985
Navigation
Issued 18 April 1985
Resolved
RECONNECT RUDDER ANGLE INDICATOR FOR STEERING RUDDERS.
Condition: Unknown
Due 18 April 1985
Resolved 18 April 1985
Accommodation/Occupational Safety
Issued 18 April 1985
Resolved
INSTALL HANDRAIL ALONG PORT SIDE OF SUPERSTRUCTURE.
Condition: Unknown
Due 18 April 1985
Resolved 18 April 1985
Engineering
Issued 18 April 1985
Resolved
INSTALL FLAME SCREEN ON VENT FOR FUEL TANK.
Condition: Unknown
Due 18 April 1985
Resolved 18 April 1985
Navigation
Issued 18 April 1985
Resolved
INSTALL SIDE SCREENS FOR RUNNING LIGHTS.
Condition: Unknown
Due 18 April 1985
Resolved 18 April 1985