Records from 1984 to 1992. Most recent: inspection, 24 November 1992.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 45
24 November 1992
Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1138470
6 March 1992
Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 948601
29 November 1991
Deficiency Check · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1248480
5 September 1991
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 942687
12 April 1991
Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 903548
4 April 1991
COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 905020
4 April 1991
Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 929030
2 April 1991
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 921847
19 March 1991
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 998443
23 November 1990
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 908119
5 November 1990
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1216279
17 October 1990
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1212815
10 October 1990
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 901453
14 August 1990
Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1220432
24 January 1990
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1216041
14 December 1989
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1242538
21 July 1989
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 971143
20 June 1989
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1351857
15 June 1989
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1031269
5 January 1989
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1042322
5 January 1989
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1205785
16 December 1988
Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1036130
26 October 1988
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1201546
24 August 1988
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1346497
6 July 1988
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 896687
12 May 1988
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1348422
26 April 1988
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1342767
12 April 1988
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1039082
2 October 1987
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1319709
27 August 1987
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1031840
28 July 1987
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1340758
13 July 1987
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1018480
15 May 1987
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1025240
12 May 1987
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1334305
30 April 1987
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1015852
6 January 1987
Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1310614
15 December 1986
Deficiency Check · Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1022335
12 December 1986
Administrative
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1336087
27 August 1986
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 990066
25 July 1986
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1310192
21 July 1986
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 996631
8 August 1985
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1297306
3 January 1985
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1284904
29 December 1984
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 976463
5 November 1984
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 976350
Engineering
Issued 4 April 1991
Resolved
PROVE ALL SAFETY DEVICES INCLUDING OVERSPEED, LOW LUBE OIL, HIGH TEMPERATURE, ETC., FOR FOR GAS TURBINE AUXILIARY ENGINE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 April 1991
Resolved 4 April 1991
Accommodation/Occupational Safety
Issued 4 April 1991
Resolved
PROVIDE PLACARD FOR TYPE II MARINE SANITATION DEVICE FROM MANUFACTURER._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 April 1991
Resolved 4 April 1991
Construction/Loadline
Issued 2 April 1991
Resolved
REPAIR TRIPPED STRENGTH MEMBER WHERE STEM IS OFF SET FRM CENTERLINE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 2 April 1991
Resolved 2 April 1991
Navigation
Issued 2 April 1991
Resolved
REPAIR PROPULSIVE RUDDER SYSTEM._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 2 April 1991
Resolved 2 April 1991
Lifesaving
Issued 2 April 1991
Resolved
"END FOR END FALLS" AT DDX.
Condition: Unknown
Due 2 April 1991
Resolved 2 April 1991
Lifesaving
Issued 2 April 1991
Resolved
CONDUCT WEIGHT TEST OF L/B AT DDX
Condition: Unknown
Due 2 April 1991
Resolved 2 April 1991
Navigation
Issued 17 October 1990
Resolved
HYDROTEST, UNDER THE OBSERVATION OF A CG INSPECTOR, BOTH BOILER CONTROL AIRP/V, POTABLE WATER TANK, AND 75 PSI SHIP SERV AIR P/V, AS PER 46CFR SUBCHAPTER F. REQUIREMENT TO BE COMPLETED DURING OR BEFORE VSL'S NEXT YARDAVAILABILITY, NLT 30MAR91, TO SATISFACTION OF COGNIZANT OCMI.
Condition: Unknown
Due 17 October 1990
Resolved 17 October 1990
Fire Fighting
Issued 10 October 1990
Resolved
REPAIR #1 FIRE PUMP.
Condition: Unknown
Due 10 October 1990
Resolved 10 October 1990
Engineering
Issued 10 October 1990
Resolved
REPAIRED SHAFT TACHOMETER.
Condition: Unknown
Due 10 October 1990
Resolved 10 October 1990
Engineering
Issued 10 October 1990
Resolved
REPAIR O.W.S. OIL CONTENT METER. SAMPLING SHAFT NOT MOVING.
Condition: Unknown
Due 10 October 1990
Resolved 10 October 1990
Engineering
Issued 10 October 1990
Resolved
REPAIR PROPULSIVE RUDDER.
Condition: Unknown
Due 10 October 1990
Resolved 10 October 1990
Engineering
Issued 10 October 1990
Resolved
REPAIR #1 AUX BOILER AND TEST FOR CG INSPECTOR. SHOW THAT SAFETY RELIEF VALVES OPERATE AT PROPER PRESSURE.
Condition: Unknown
Due 10 October 1990
Resolved 10 October 1990
Engineering
Issued 10 October 1990
Resolved
REPAIR PORT AUXILIARY BOILER LOW WATER ALARM.
Condition: Unknown
Due 10 October 1990
Resolved 10 October 1990
Engineering
Issued 10 October 1990
Resolved
REPAIR PORT AUXILIARY BOILER CONTROL AIR LOW PRESSURE ALARM.
Condition: Unknown
Due 10 October 1990
Resolved 10 October 1990
Engineering
Issued 10 October 1990
Resolved
OPEN ALL PRESSURE VESSELS FOR INTERNAL INSPECTION OR HYDRO TEST.
Condition: Unknown
Due 10 October 1990
Resolved 10 October 1990
Engineering
Issued 10 October 1990
Resolved
REPAIR RELIEF VALVE ON INBOARD MAIN DIESEL PROPULSION GENERATOR STARTING AIR RECIEVER, VALVE CHATTERS.
Condition: Unknown
Due 10 October 1990
Resolved 10 October 1990
Engineering
Issued 10 October 1990
Resolved
REPAIR ISOLATION VALVES ON MAIN D.E GENERATOR STARTING AIR RECIEVERS SO THAT THEY MAY BE ISOLATED AND THE RELIEF VALVES TESTED.
Condition: Unknown
Due 10 October 1990
Resolved 10 October 1990
Engineering
Issued 10 October 1990
Resolved
TEST MDE AIR RECIEVER RELIEF VALVES.
Condition: Unknown
Due 10 October 1990
Resolved 10 October 1990
Engineering
Issued 10 October 1990
Resolved
TEST RELIEF VALVE ON GENERATOR STARTING AIR RECIEVER.
Condition: Unknown
Due 10 October 1990
Resolved 10 October 1990
Documentation
Issued 10 October 1990
Resolved
SUBMIT LETTER TO [name withheld] AS "OCEANOGRAPHIC RESEARCH VESSEL".
Condition: Unknown
Due 10 October 1990
Resolved 10 October 1990
Fire Fighting
Issued 10 October 1990
Resolved
DEMONSTRATE OPERATION OF #1 FIRE PUMP.
Condition: Unknown
Due 10 October 1990
Resolved 10 October 1990
Lifesaving
Issued 10 October 1990
Resolved
HAVE 50 PFD'S IN SERVICEABLE CONDITION WITH LIGHTS AND WHISTLES.
Condition: Unknown
Due 10 October 1990
Resolved 10 October 1990
Lifesaving
Issued 10 October 1990
Resolved
REPLACE NYLON LIFELINES AT LIFEBOAT STATION WITH CABLE OR CHAIN.
Condition: Unknown
Due 10 October 1990
Resolved 10 October 1990
Engineering
Issued 10 October 1990
Resolved
REPAIR EOT POWER FAILURE ALARM CIRCUITS (ON BRIDGE.)
Condition: Unknown
Due 10 October 1990
Resolved 10 October 1990
Lifesaving
Issued 10 October 1990
Resolved
CONDUCT WEIGHT TEST OF LIFEBOAT.
Condition: Unknown
Due 10 October 1990
Resolved 10 October 1990
Construction/Loadline
Issued 10 October 1990
Resolved
REPAIR TRIPPED STRENGTH MEMBERS WHERE STEM IS OFFSET FROM CENTERLINE.
Condition: Unknown
Due 10 October 1990
Resolved 10 October 1990
Engineering
Issued 10 October 1990
Resolved
REPAIR PROPULSIVE RUDDER SYSTEM.
Condition: Unknown
Due 10 October 1990
Resolved 10 October 1990
Engineering
Issued 10 October 1990
Resolved
REPAIR 75 PSI SHIPS SERVICE AIR RECIEVER RELIEF VALVE. VALVE LIFTS A 62PSI VALVE RATING IS 82 PSI. VALVE SETTING MUST BE WITHIN 10% OF RATED PRESSURE.
Condition: Unknown
Due 10 October 1990
Resolved 10 October 1990
Lifesaving
Issued 10 October 1990
Resolved
REPLACE LIFEBOAT FIRST AID KIT.
Condition: Unknown
Due 10 October 1990
Resolved 10 October 1990
Lifesaving
Issued 10 October 1990
Resolved
REPLACE LIFEBOAT PROVISIONS.
Condition: Unknown
Due 10 October 1990
Resolved 10 October 1990
Lifesaving
Issued 10 October 1990
Resolved
DEMONSTRATE OPERATION OF LIFEBOAT ENGINE.
Condition: Unknown
Due 10 October 1990
Resolved 10 October 1990
Lifesaving
Issued 10 October 1990
Resolved
REPLACE WATERLIGHT-, SMOKE FLOAT-, TAG-, AND LIFE-LINES ON RING BUOYS.
Condition: Unknown
Due 10 October 1990
Resolved 10 October 1990
Accommodation/Occupational Safety
Issued 21 July 1989
Resolved
SECURE MSD OVERBOARD DISCHARGE VALVE AND STENCIL.
Condition: Unknown
Due 21 July 1989
Resolved 21 July 1989
Electrical
Issued 21 July 1989
Resolved
REPAIR AND TEST FOUR INOPERATIVE GENERAL ALARMS.
Condition: Unknown
Due 21 July 1989
Resolved 21 July 1989
Electrical
Issued 21 July 1989
Resolved
REPAIR AND TEST 6 INOPERATIVE OR WEAK BATTLE LANTERNS.
Condition: Unknown
Due 21 July 1989
Resolved 21 July 1989
Electrical
Issued 16 December 1988
Resolved
PROVIDE USCG APPROVED PLANS FOR THE NEWLY INSTALLED INTRUSION ALARM AND SECURITY LIGHTING SYSTEMS.
Condition: Unknown
Due 16 December 1988
Resolved 16 December 1988
Electrical
Issued 26 October 1988
Resolved
DEMONSTRATE LIFERAFT/LIFEBOAT EMBARKATION LIGHTS; AND EMERGENCY LIGHTS IN #2 S/S GENERATOR ROOM AND ENGINE ROOM ESCAPE TRUNK TO ENSURE THE INSTALLA- TION IS IN ACCORDANCE WITH USCG APPROVED PLANS.
Condition: Unknown
Due 26 October 1988
Resolved 26 October 1988
Electrical
Issued 26 October 1988
Resolved
SUBMIT PLANS FOR APPROVAL TO USCG MARINE SAFETY CENTER, WICH COMPLY WITH "OLD" SUBCHAPTER "J" FOR LIFERAFT & LIFEBOAT EMBARKATION LIGHTS; AND EMER- GENCY LIGHTS IN #2 S/S GENERATOR ROOM AND ENGINE ROOM ESCAPE TRUNK.
Condition: Unknown
Due 26 October 1988
Resolved 26 October 1988
Lifesaving
Issued 24 August 1988
Resolved
MAKE PREM. REPAIRS TO PORT LIFEBOAT OR REPLACE PRIOR TO VESSEL DEPARTURE THE PORT OF SEATTLE WA
Condition: Unknown
Due 24 August 1988
Resolved 24 August 1988
Electrical
Issued 24 August 1988
Resolved
INSTALL EMBARKATION LIGHTING (AT LIFEBOAT STA #1 AND LIFERAFT STA#1,3) LIGHTS MUST BE EMEGENCY LIGHTS
Condition: Unknown
Due 24 August 1988
Resolved 24 August 1988
Electrical
Issued 24 August 1988
Resolved
PROVIDE ADEQUATE AND EFFECTIVE EMERGENCY LIGHTING IN #2 S/S GEN. ROOM AND ESCAPE TRUNK EXITING ENGINE CONTROL ROOM.
Condition: Unknown
Due 24 August 1988
Resolved 24 August 1988
Lifesaving
Issued 24 August 1988
Resolved
CONDUCT FIRE AND LIFEBOAT HANDLING DRILLS PRIOR TO VESSELS DEPARTURE THE PORT OF SEATTLE
Condition: Unknown
Due 24 August 1988
Resolved 24 August 1988
Lifesaving
Issued 13 July 1987
Resolved
PROVIDE A USCG APPROVED EMBARKATION LADDER TO SERVICE LIFERAFT STATIONS #1 AND #3.
Condition: Unknown
Due 13 July 1987
Resolved 13 July 1987
Electrical
Issued 13 July 1987
Resolved
PRIOR TO USE, DEMONSTRATE TO ATTENDING MARINE INSPECTOR OPERATION OF ALL SAFETY CUT OUTS AND ALARMS ON GAS TURBINE GENERATOR.
Condition: Unknown
Due 13 July 1987
Resolved 13 July 1987
Navigation
Issued 13 July 1987
Resolved
REPLACE SPLIT RING HYDRAULIC FITTINGS ON THE STEERING GEAR UNIT WITH APPROVED FITTINGS.
Condition: Unknown
Due 13 July 1987
Resolved 13 July 1987
Construction/Loadline
Issued 13 July 1987
Resolved
INSTALL PROPER REDUCING JOINTS PER 46CFR56 ON ALL LINES COMING OFF SEACHESTS.
Condition: Unknown
Due 13 July 1987
Resolved 13 July 1987
Electrical
Issued 13 July 1987
Resolved
PROVIDE EMERGENCY LIGHTING TO LIFEBOAT EMBARKATION STATION ON PORT SIDE ANDLIFERAFT #1 AND #3 EMBARKATION STATIONS.
Condition: Unknown
Due 13 July 1987
Resolved 13 July 1987
Lifesaving
Issued 30 April 1987
Resolved
1. REPAIR PORT LIFE BOAT, FAIR STARBOARD SIDE INDENTATION NEAR NAND RAIL. STRAIGHTEN HAND RAIL AND ATTACH AS ORIGINAL.
Condition: Unknown
Due 30 April 1987
Resolved 30 April 1987
Unknown
Issued 27 August 1986
Resolved
INSTALL A PROPER SCHRODER VALVE TO THE DOMESIC FRESH WATER TANK OR OPEN AND TEST AS A PRESSURE VESSEL.
Condition: Unknown
Due 27 August 1986
Resolved 27 August 1986
Construction/Loadline
Issued 27 August 1986
Resolved
MAKE REPAIRS TO THE REMOTE INDICATING DEVICE FOR THE WATERTIGHT DOOR.
Condition: Unknown
Due 27 August 1986
Resolved 27 August 1986
Construction/Loadline
Issued 3 January 1985
Resolved
RENEW/REPAIR REMOTE INDICATOR,ON MAIN DECK, FOR HYDRAULIC WATER TIGHT DOOR.
Condition: Unknown
Due 3 January 1985
Resolved 3 January 1985
Lifesaving
Issued 29 December 1984
Resolved
STENCIL SURVIVAL/EXPOSURE SUITS WITH VESSEL NAME.
Condition: Unknown
Due 29 December 1984
Resolved 29 December 1984
Accommodation/Occupational Safety
Issued 29 December 1984
Resolved
REPAIR/REPLACE CHLORINATOR FOR MSD AND PROVIDE PROPER CHEMICALS.
Condition: Unknown
Due 29 December 1984
Resolved 29 December 1984
Construction/Loadline
Issued 29 December 1984
Resolved
REPAIR HYDRAULIC PIPING AND PROVE PROPER OPERATION OF REMOTE WATER TIGHT DOOR HAND ACTUATING PUMP.
Condition: Unknown
Due 29 December 1984
Resolved 29 December 1984
Unknown
Issued 29 December 1984
Resolved
CONDUCT FIRE AND BOAT DRILL IN COAST GUARD PRESENCE.
Condition: Unknown
Due 29 December 1984
Resolved 29 December 1984
Lifesaving
Issued 29 December 1984
Resolved
RENEW TILLER FOR LIFEBOAT.
Condition: Unknown
Due 29 December 1984
Resolved 29 December 1984
Engineering
Issued 29 December 1984
Resolved
REPAIR/REPLACE RELIEF VALVE ON POTABLE WATER CUSHION TANK.
Condition: Unknown
Due 29 December 1984
Resolved 29 December 1984
Engineering
Issued 29 December 1984
Resolved
REPAIR/REPLACE TACHOMETER FOR #2 SS/DG.
Condition: Unknown
Due 29 December 1984
Resolved 29 December 1984