SITEAM JUPITER

SITEAM JUPITER is a 2000 tank ship. The Coast Guard has recorded 37 inspections since 2000, most recently in May 2014, along with 4 deficiencies and 9 operational controls.

Records from 2000 to 2014. Most recent: inspection, 26 May 2014.

Built
2000
Last inspected
26 May 2014
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9185487 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
NORWAY
—
Maury page id
psix-2289

Inspections, by type

…with no type recorded17
Years with a record 11 calendar years (2000–2014)
The 37 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 12 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it48338 - Dead Weight, Ton
58183 - Displacement, Ton
27185 - Convention (Subpart B), Gross Ton
14085 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 37

26 May 2014 Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4869821
23 May 2014 Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4866263
20 May 2014 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 4864001
19 May 2014 COC-CHEM & TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4860157
19 May 2014 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4862011
1 November 2010 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3882211
26 October 2010 COC-CHEM Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3878313
4 April 2009 Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3446708
22 March 2009 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3437915
12 February 2009 Ballast Water Examination · COC-CHEM Annual · ISPS III Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3414699
29 December 2008 Type not recorded
No type recorded · Sector New York · USCG Northeast District (CGD-NE) · Activity 3385011
29 December 2008 ISPS I Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3385775
21 August 2008 PII Safety Exam · MARPOL Annex V Examination · MARPOL Annex I Examination · ISPS I Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3299176
20 August 2008 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3299179
20 August 2008 Type not recorded
No type recorded · USCGC STURGEON (WPB 87336) · USCG Northeast District (CGD-NE) · Activity 3424042
22 February 2008 ISPS III Exam · MARPOL Annex I Examination · MARPOL Annex V Examination · MARPOL Annex II Examination · Ballast Water Examination · COC-CHEM Renew
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3148035
30 July 2007 Damage Survey
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3012895
30 July 2007 Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3027530
14 July 2007 Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 2994931
22 May 2007 MARPOL Annex V Examination · ISPS II Exam · MARPOL Annex I Examination · MARPOL Annex II Examination · COC-CHEM Annual · Ballast Water Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2934204
2 October 2006 Random ISPS/MTSA/PSC
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2791817
24 September 2006 Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2785817
22 March 2006 Ballast Water Examination · COC-CHEM Renew · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2607728
21 March 2006 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2606692
29 October 2004 Random ISPS/MTSA/PSC
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2231078
24 October 2004 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2227106
12 October 2004 ISPS II Exam · COC-CHEM Annual
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2219037
4 February 2004 Annual Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2000581
3 October 2003 Certificate of Compliance · Ballast Water Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1920668
26 November 2002 Security Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1711021
1 July 2002 Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1639665
4 March 2002 Security Inspection · In-Service Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1490771
27 September 2001 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 294239
10 May 2001 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 290139
7 July 2000 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 279677
18 May 2000 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 277986
18 May 2000 Letter of Compliance (Initial/Renewal)
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1049605

Deficiency record · 4

Navigation › Collision/Grounding Avoidance › Radar
Issued 19 May 2014 Resolved
1530- Radar- Vessel's S-band radar is inoperable. LOD issued. - SOLAS 74(a) V/12
Action required: 17 - Rectify deficiencies prior to departure
Due 19 May 2014
Resolved 26 May 2014
Resolution: Received tech report from IMTECH satisfying requirement.
Deck/Cargo › Holds/Tanks › Fixed Gas Detection
Issued 19 May 2014 Resolved
1840- Instrumentation- The flow meter on the gas detection system for the ballast tanks is inoperable- SOLAS 74(a) II-2/59
Action required: 705 - Other - as specified
Due 19 May 2014
Resolved 19 May 2014
Resolution: Electrician renewed flow meter from spare parts onboard prior to PSCO departure.
Electrical › Electric Generation Source (emergency) › Power Requirement
Issued 22 March 2006 Resolved
Emergency generator secondary starting system (batteries) failed to start.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 March 2006
Resolution: Received satisfactory class report.
Deck/Cargo
Issued 18 May 2000 Resolved
Permanently affix 1.0" long, 0.5" diameter studs to vapor connection flanges IAW 46 CFR 39.20.
Condition: Unknown
Due 7 July 2000
Resolved 7 July 2000

Ownership record