VOLSUNGA IV

VOLSUNGA IV is a 1983 passenger vessel (inspected). The Coast Guard has recorded 13 inspections since 2016, most recently in April 2026, along with 40 deficiencies and 1 casualty investigation in 2017.

Records from 2016 to 2026. Most recent: inspection, 17 April 2026.

Built
1983
Last inspected
17 April 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record, the casualty record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 17 April 2026
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 8 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WCY4353
228907
Flag
UNITED STATES
Maury page id
psix-228907

Documentation record

Registered dimensions (L × B × D)38.2 ft × 13.6 ft × 6.8 ft
Registered tonnagegross 19 / net 18
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBURPEE'S COMMERCIAL WK BT · MEDLEY, FL, UNITED STATES · built 1983
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSTONY CREEK, CT
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 18 July 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it19 - Regulatory (Subpart C or D), Gross Ton
18 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

13 inspections, each with its date, unit and type; 40 deficiencies with the resolution recorded against each; 1 casualty investigation, with date and classification; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 13

17 April 2026 Annual Inspection · Hull Examination · Internal Structural Exam · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8351391
13 June 2024 COI Inspection · Hull Examination · Deficiency Check · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7916955
23 August 2023 COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7762521
19 April 2022 Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7422159
30 May 2020 Hull Examination · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6964039
24 February 2020 Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6914271
24 September 2018 Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6547337
25 April 2018 Internal Structural Exam · Hull Examination · Examination of Repairs
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6400021
21 August 2017 Damage Survey · Examination of Repairs
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6247543
20 August 2017 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6318447
22 June 2017 Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6186999
24 June 2016 COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5917744
29 March 2016 Hull Examination · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5842914

Deficiency record · 40

11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 May 2026 Resolved
Label all lifejacket storage containers with adult/child and # of life jackets
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 May 2026
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 May 2026 Resolved
Missing 02 adult and 01 child life jackets
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 May 2026
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 15 May 2026 Resolved
Provide 6 flares
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 May 2026
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 15 May 2026 Resolved
Missing securing device for all deck hatches
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 May 2026
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 May 2026 Resolved
Provide line for fire bucket
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 May 2026
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 15 May 2026 Resolved
E/R & mid void bilge high water alarm inop
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 May 2026
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 15 May 2026 Resolved
Provide 2nd flash light
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 May 2026
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 15 May 2026 Resolved
Provide proof of drug testing enrollment
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 May 2026
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 13 June 2024 Resolved
Provide valid COD
Action required: 17 - Rectify deficiencies prior to departure
Resolved 1 July 2024
Resolution: Cleared.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 13 June 2024 Resolved
Provide shutoff valve for lazeret bilge discharge line.
Action required: 705 - Other - as specified
Resolved 8 July 2024
Resolution: Shutoff installed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 13 June 2024 Resolved
Remove check valve for bilge discharge line in E/R.
Action required: 705 - Other - as specified
Resolved 8 July 2024
Resolution: check valve removed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 13 June 2024 Resolved
Provide closing device for E/R air intake.
Action required: 705 - Other - as specified
Resolved 8 July 2024
Resolution: Air intake covers provided.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 13 June 2024 Resolved
Provide 30X30 flame screen for fuel vent.
Action required: 705 - Other - as specified
Resolved 10 July 2024
Resolution: Flame screen provided.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 23 August 2023 Resolved
Conduct man overboard and fire drill with designated crew in the presence of a USCG Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 June 2024
Resolution: Witnessed drills.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 23 August 2023 Resolved
Provide FCC safety radio certificate and FCC Station license.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 June 2024
Resolution: Vessel will be limited to 1000 feet from shore.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 August 2023 Resolved
Provide first aid kit.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 July 2024
Resolution: First aid kit provided.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 23 August 2023 Resolved
Provide 2 portable lights (operating station and E/R.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 June 2024
Resolution: Lights provided.
99 - Other › N/A - No Subsystem › Other (SOLAS operational)
Issued 23 August 2023 Resolved
Provide evidence of a drug and alcohol program.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 June 2024
Resolution: DAPI evaluated.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 23 August 2023 Resolved
Provide current tide tables, currents and coast pilot (Eldridge)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 June 2024
Resolution: Pubs provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 August 2023 Resolved
Provide 03 adult life jackets and life jacket donning placard.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 July 2024
Resolution: Life jackets provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 August 2023 Resolved
Provide and attach floating water light for life ring. Water light must have a 3' line with corrosion resistant clip.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 July 2024
Resolution: Water light provided.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 August 2023 Resolved
Provide lanyards and label fire buckets.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 June 2024
Resolution: Fire buckets sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 August 2023 Resolved
Renew fuel tank vent.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 June 2024
Resolution: New vent installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 June 2020 Resolved
Tailshaft bearing shall have more than 50% water groove. Wear for the water groove is barely visible with less than 50%.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 11 July 2020
Resolved 16 July 2020
Resolution: New bearing installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 June 2020 Resolved
Propeller shall be free major corrosion and pitting. Excessive corrosion on 1/3 critical area and around ends.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 11 July 2020
Resolved 16 July 2020
Resolution: New propeller installed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 September 2018 Resolved
Provide drug testing documentation for owner/operator of the vessel.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 October 2018
Resolved 13 June 2024
Resolution: Verified on 2024 COI.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 24 September 2018 Resolved
Provide radio safety certificate.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 October 2018
Resolved 15 October 2018
Resolution: Radio certificate received.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 24 September 2018 Resolved
Secure all bilge pump high water switches.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 October 2018
Resolved 13 June 2024
Resolution: Switches mounted.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 September 2018 Resolved
Install 8 life jackets. Vessel is restricted to 42 persons on board.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 October 2018
Resolved 6 October 2018
Resolution: 8 life jackets installed.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 24 September 2018 Resolved
Provide light list and notice to mariners.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 October 2018
Resolved 17 October 2018
Resolution: Light list provided.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 24 September 2018 Resolved
Secure Nav Lights
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 October 2018
Resolved 13 June 2024
Resolution: Nav lights secured.
Construction/Loadline › Hull › Bottom Plating
Issued 21 August 2017 Resolved
Repair keel/hull damage. Submit repair proposal.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 September 2017
Resolution: Keel repaired and FRP was layered to one (1) inch thick.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 22 June 2017 Resolved
Provide a copy of the Coast Pilot and Light List.
Condition: Improper/Lack of Maintenance
Due 22 July 2017
Resolved 4 August 2017
Resolution: Printed.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 22 June 2017 Resolved
Provide COD
Due 22 July 2017
Resolved 6 August 2017
Resolution: COD Provided.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 22 June 2017 Resolved
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 19 September 2017
Resolution: Drug paper work provided.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Remote Pulls
Issued 22 June 2017 Resolved
Install tamper seal on Fireboy manual pull handle.
Condition: Improper/Lack of Maintenance
Due 29 June 2017
Resolved 4 August 2017
Resolution: Seal installed.
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 22 June 2017 Resolved
Replace P/S cooling hose on MDE.
Condition: Improper/Lack of Maintenance
Due 22 July 2017
Resolved 4 August 2017
Resolution: hose replaced
Engineering › Diesel Engine (propulsion-direct drive) › Exhaust Manifold
Issued 22 June 2017 Resolved
Repair exhaust leak cooling hose clamp on MDE
Condition: Improper/Lack of Maintenance
Due 22 July 2017
Resolved 4 August 2017
Resolution: clamp replaced.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Remote Pulls
Issued 22 June 2017 Resolved
Install fire bottle cable pin.
Condition: Improper/Lack of Maintenance
Due 29 June 2017
Resolved 4 August 2017
Resolution: pin installed
Engineering › Steering Gear System › Hydraulic Hose
Issued 29 March 2016 Resolved
Repair leaks in the steering system.
Condition: Improper/Lack of Maintenance
Due 22 July 2016
Resolved 29 June 2016
Resolution: Hose replaced.

Casualty record · 1

20 August 2017Routine · role: Involved in a Marine Casualty · activity 6318447