Records from 1985 to 2021. Most recent: inspection, 4 January 2021.
Inspection history · 123
4 January 2021
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7132019
18 May 2020
Drydock Extension
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6961094
3 April 2020
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6937197
4 April 2019
Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6653974
30 August 2018
Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6527278
13 March 2018
Annual Inspection · Examination of Repairs · Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6371333
8 March 2017
Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6101076
22 March 2016
Drydock Exam · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5838115
19 January 2016
COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5799515
18 March 2014
Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4815805
4 March 2014
Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4809765
7 May 2012
Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4368222
1 February 2012
DAPI Audit
Administrative · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 4239300
14 January 2011
COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3926659
8 March 2010
Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3691756
30 March 2009
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3437143
30 January 2009
DAPI Audit
Administrative · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 3402912
25 March 2008
Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3166084
5 March 2008
Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3159079
15 January 2008
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3114522
28 February 2007
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2878079
3 July 2006
Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2700084
28 March 2006
Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2609018
28 November 2005
COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2541728
17 June 2005
Administrative Inspection
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2393551
8 April 2005
Type not recorded
No type recorded · Station San Francisco · USCG Southwest District (CGD-SW) · Activity 2329410
8 April 2005
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2334203
7 April 2005
Damage Survey
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2342483
28 January 2005
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2282349
21 January 2005
Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2260510
29 July 2004
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2127426
19 March 2004
Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2027546
30 January 2004
Drydock Extension · Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1983685
16 January 2003
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1731304
2 January 2003
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1724381
20 December 2002
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1721773
12 November 2002
Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1704110
16 April 2002
Administrative Inspection
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1605321
20 March 2002
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1495568
14 February 2002
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1483437
23 January 2002
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1480900
10 November 2001
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1487959
23 October 2001
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1376775
9 October 2001
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 77844
9 October 2001
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1073701
17 January 2001
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1369971
30 April 2000
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 126781
23 February 2000
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1397353
29 November 1999
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 812707
4 July 1999
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 143447
5 May 1999
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 793496
20 April 1999
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 790064
5 November 1998
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 808946
6 March 1998
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1120610
10 February 1998
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1113685
26 January 1998
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 781913
14 January 1998
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 62212
13 January 1998
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1122225
12 December 1997
Examination of Repairs
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1115433
11 December 1997
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 101085
13 March 1997
Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1093386
13 March 1997
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1123651
9 January 1997
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1098005
4 December 1996
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1441145
11 August 1996
Damage Survey
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1089342
10 August 1996
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 69829
7 July 1996
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 137929
26 April 1996
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1080174
1 March 1996
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 884553
8 February 1996
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1182503
14 November 1995
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1184517
28 June 1995
Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1383109
11 April 1995
Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1155562
27 March 1995
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1139417
3 February 1995
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 833710
27 January 1995
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1392157
1 December 1994
Re-Inspection · Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1370960
1 November 1994
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 862590
1 October 1994
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 27869
1 October 1994
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 63255
1 October 1994
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 175352
1 October 1994
Damage Survey
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1377281
28 September 1994
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 28027
22 September 1994
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 171442
11 January 1994
Deficiency Check · Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1443432
21 December 1993
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1160027
14 December 1993
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 848935
25 October 1993
Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 963201
8 October 1993
Examination of Repairs
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1387403
7 October 1993
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 658402
2 October 1993
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 54002
2 October 1993
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 95512
5 February 1993
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1136686
21 December 1992
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1136297
17 November 1992
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1132531
28 January 1992
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 961916
29 August 1991
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1309388
16 February 1991
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 915532
2 January 1991
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1236464
28 November 1990
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 907346
29 May 1990
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 914411
2 January 1990
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1212275
1 December 1989
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1219764
9 November 1989
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1221997
25 September 1989
Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1203938
19 July 1989
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1323523
15 April 1989
Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1036789
17 March 1989
Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1035135
15 February 1989
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1343173
31 January 1989
Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1339577
19 January 1989
Hull Examination · Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1209576
31 December 1988
Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1043972
28 October 1988
Drydock Extension
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 890791
1 August 1988
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1342237
8 July 1988
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1207485
18 May 1988
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1350826
3 May 1988
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1343313
4 February 1988
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1018090
28 January 1988
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1039813
6 November 1987
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1330486
20 April 1987
Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1311198
13 November 1986
Hull Examination · COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1016413
28 March 1985
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1292213
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 3 April 2020
Resolved
Vessel hatches on the weather deck shall be weathertight on protected waters. The 03 forward hatches are only set in place, which does not meet the watertight requirement. OLD-T 46 CFR 178.35(a).
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 May 2020
Resolution: Vessel gasketed and bolted down hatch covers renewing their watertight integrity.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 3 April 2020
Resolved
The bulkhead deck shall be watertight. The deck in way of the stbd engine room was found holed and taped over.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 May 2020
Resolution: Vessel completed weld repairs to deteriorated areas.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 3 April 2020
Resolved
Marine Inspector may check the condition of the superstructure to satifsy himself of the condition of the hull structure. Pilot house structure framing found significantly deteriorated long the port side and lower sections; framing to be renewed to ensure structure is properly supported at the next dry-dock. OLD T 46CFR 176.25-5
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 30 April 2020
Resolution: Pilothouse structure was rebuilt in kind.
Construction/Loadline › Hull › Transverse Frame
Issued 9 March 2010
Resolved
Crop and renew forward frame in port forward void to like new metal. Prior to credit dry dock.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 March 2010
Resolution: Repair complete and verified.
Construction/Loadline › Hull › Bottom Plating
Issued 9 March 2010
Resolved
Properly clad weld pit approximately 18" aft of frame in requirement #1.
Action required: 705 - Other - as specified
Resolved 12 March 2010
Resolution: Repair completed and verified.
Fire Fighting › Portable CO2 Fire Extinguisher › Pressure Gauge
Issued 30 March 2009
Resolved
1 B-II in bar area on main deck looked like it had a leak as reflected by indicator.
Due 30 April 2009
Resolved 30 March 2009
Resolution: Corrected on the spot.
Navigation › Piloting/Steering › US Coast Pilot
Issued 30 March 2009
Resolved
Provide current Coast Pilot.
Due 30 April 2009
Resolved 30 March 2009
Resolution: Corrected on the spot.
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 30 March 2009
Resolved
Provided updated version of Nav Rules.
Due 30 April 2009
Resolved 30 March 2009
Resolution: Corrected on the spot.
Fire Fighting › Fire Hoses › Condition
Issued 30 March 2009
Resolved
Repair slow leak on end of fire hose.
Due 30 April 2009
Resolved 30 March 2009
Resolution: Corrected on the spot.
Construction/Loadline › Hull › Hull Plating
Issued 25 March 2008
Resolved
Submit repair proposal to repair hole in the stbd hull, fwd bow and approx frame 4 or 5.
Due 25 March 2008
Resolved 25 March 2008
Construction/Loadline › Hull › Hull Plating
Issued 25 March 2008
Resolved
Make repairs to the stbd hull, fwd bow in accordance with approved plans.
Action required: 705 - Other - as specified
Resolved 26 March 2008
Construction/Loadline › Hull › Hull Plating
Issued 25 March 2008
Resolved
In accordance with approved plans make repairs to all identified areas of the hull. 3 inserts and clad welding spots on all three hulls.
Action required: 705 - Other - as specified
Resolved 31 March 2008
Electrical › Electrical Distribution System (service) › Wiring
Issued 12 December 2007
Resolved
Replace electrical "extension cords" providing power to Christmas lights on upper deck in accordance with 46 CFR 183.340.
Action required: 705 - Other - as specified
Due 15 February 2008
Resolved 5 March 2008
Resolution: Electrical wiring replaced.
Engineering › Pressure Vessel › Relief Valve
Issued 12 December 2007
Resolved
Install 100 psi/250 degree temperature pressure relief valve on water heater I.A.W. 46 CFR 182.320(b).
Action required: 705 - Other - as specified
Due 15 February 2008
Resolved 5 March 2008
Resolution: Improper requirement issued, removed requirement.
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 18 January 2006
Resolved
Properly label high level alarms at operating station.
Action required: 705 - Other - as specified
Due 31 March 2006
Resolved 28 March 2006
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 18 January 2006
Resolved
Prove proper operation of bilge high level alarm in way of fwd, center void or prove bow thrust penetrations have been properly plated off.
Action required: 705 - Other - as specified
Due 31 March 2006
Resolved 28 March 2006
Resolution: Bow thruster penetrations have been properly plated off.
Electrical › Lighting (service) › Lighting Fixture
Issued 18 January 2006
Resolved
Properly connect electrical wires in way of stbd engine room bilge pump and upper deck dining lights IAW 46CFR183.340(i)(2) (remove wire nuts).
Action required: 705 - Other - as specified
Due 31 March 2006
Resolved 28 March 2006
Engineering › Electric Propulsion System › Overcurrent Device Circuitry
Issued 18 January 2006
Resolved
Install overcurrent protection to all batteries in both port to stbd engine rooms IAW 46CFR183.350(g).
Action required: 705 - Other - as specified
Due 31 March 2006
Resolved 6 July 2006
Engineering › Sea-water System (primary cooling) › Piping
Issued 18 January 2006
Resolved
Properly support raw water flex hose and flow switch in stbd engine room outboard.
Action required: 705 - Other - as specified
Due 31 March 2006
Resolved 28 March 2006
Engineering › Steering Gear System › Hydraulic Hose
Issued 18 January 2006
Resolved
Install metallic thru bulkhead fittings and replace hydraulic hoses with J-1942 standard hoses to steering gear in way of port engine room/lazarette IAW 46CFR182.720.
Action required: 705 - Other - as specified
Due 31 March 2006
Resolved 6 July 2006
Stability › Weathertight Integrity › General
Issued 18 January 2006
Resolved
Renew cracked plexiglass in way of fwd main deck port side corner at gangway.
Action required: 705 - Other - as specified
Due 31 March 2006
Resolved 28 March 2006
Construction/Loadline › Structures › Deck Plating
Issued 18 January 2006
Resolved
Renew frame and deck, port and stbd side outboard of fwd engine room scuttles outboard.
Action required: 705 - Other - as specified
Due 31 March 2006
Resolved 31 March 2006
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 18 January 2006
Resolved
Properly stow all child PFD's.
Action required: 705 - Other - as specified
Due 18 January 2006
Resolved 18 January 2006
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 18 January 2006
Resolved
Aspirin, eye wash and burn treatment cream were expired.
Action required: 705 - Other - as specified
Due 18 January 2006
Resolved 18 January 2006
Navigation › Piloting/Steering › Magnetic Compass
Issued 21 January 2005
Resolved
Properly wire the magnetic compass light IAW 46 CFR 121.402
Due 21 February 2005
Resolved 28 January 2005
Stability › Watertight Integrity › General
Issued 21 January 2005
Resolved
Prove proper watertight integrity of the port aft window in the galley
Due 21 February 2005
Resolved 28 January 2005
Electrical › Electric Supply System (service) › Cable
Issued 21 January 2005
Resolved
Properly deadend electrical wire under the bar
Due 21 February 2005
Resolved 28 January 2005
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 21 January 2005
Resolved
Install outlet cover STBD side main deck behind the television.
Due 21 February 2005
Resolved 28 January 2005
Electrical › Lighting (service) › Conductor
Issued 21 January 2005
Resolved
Properly connect both stairwell lights wiring IAW 46CFR120.340(g)
Due 21 February 2005
Resolved 28 January 2005
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 21 January 2005
Resolved
Replace port side stairwell light fixture lens.
Due 21 February 2005
Resolved 28 January 2005
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 21 January 2005
Resolved
Tighten port shaft packing gland.
Due 21 February 2005
Resolved 28 January 2005
Engineering › Diesel Engine (propulsion-direct drive) › Pump, High Pressure (fuel injection)
Issued 21 January 2005
Resolved
Repair port main diesel engine fuel oil leak.
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 February 2005
Resolved 28 January 2005
Engineering › Bilge Water Management System › Pump
Issued 21 January 2005
Resolved
Prove proper operation of the bilge pumps.
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 February 2005
Resolved 28 January 2005
Documentation › Markings/Placards › Warning Signs
Issued 21 January 2005
Resolved
Properly post emergency broadcast placard.
Due 21 February 2005
Resolved 21 January 2005
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 21 January 2005
Resolved
Replace waterlight battery IAW 46CFR122.726
Due 21 February 2005
Resolved 21 January 2005
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 21 January 2005
Resolved
Properly label child PFD or remove it from the vessel.
Due 21 February 2005
Resolved 21 January 2005
Resolution: Master remove the extra child PFD from the vessel.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 29 July 2004
Resolved
Make through deck fittings for all exhaust lines watertight in way of port/starboard engines and generator.
Due 16 October 2004
Resolved 19 November 2004
Construction/Loadline › Hull › Bottom Plating
Issued 19 March 2004
Resolved
Submit repair pland for approval to repair holes in starboard hull bottom in eay of @2 void and engine space in way of shaft alley.
Due 24 March 2004
Resolved 8 April 2004
Resolution: Repaired sat.
Construction/Loadline › Hull › Bottom Plating
Issued 19 March 2004
Resolved
Provide ultra sonic testing of the entire hull bottom in way of all three hulls.
Due 24 March 2004
Resolved 8 April 2004
Resolution: Tested.
Construction/Loadline › Structures › Deck Plating
Issued 19 March 2004
Resolved
Submit repair proposal to repair holes in way of starboard aft deck (40Sq ft area aft of engine room hatch to aft fulkhead).
Due 1 April 2004
Resolved 8 April 2004
Resolution: Repaired sat.
Construction/Loadline › Structures › Scuttle
Issued 19 March 2004
Resolved
Make all watertight scuttles/hatches watertight (both enginer room hatch covers and genertor hatch cover, both port and stbd laxarette scuttles, and the aft compartment of the center hull.).
Due 24 March 2004
Resolved 16 September 2004
Engineering › Freshwater Generation System › Piping
Issued 19 March 2004
Resolved
Repair potable water leak in way of the center hull , center void.
Due 1 April 2004
Resolved 8 April 2004
Resolution: Repaired sat.
Engineering › Bilge Water Management System › Not Operational
Issued 19 March 2004
Resolved
Remove all water from all bilges.
Due 1 April 2004
Resolved 8 April 2004
Resolution: Removed sat.
Electrical › Electrical Distribution System (service) › Conductor
Issued 30 January 2004
Resolved
Provide plans to replace welding cable used in starting battery system, with Marine Grade battery cable.
Action required: 705 - Other - as specified
Due 29 February 2004
Resolved 31 August 2004
Resolution: Operator faxed one page description into this office. Forwarded to plan review officer for approval.
Engineering › Diesel Engine (propulsion-reduction gear)
Issued 30 January 2004
Resolved
Replace lagging on port and starboard exhaust pipes in way of bend above main deck.
Action required: 705 - Other - as specified
Due 30 January 2004
Resolved 30 January 2004
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 30 January 2004
Resolved
Make bend in exhaust above main deck available for inspection, with lagging removed at next dry dock.
Action required: 705 - Other - as specified
Due 29 February 2004
Resolved 16 September 2004
Resolution: Inspected exhaust piping, found that through deck penetration of the exhaust line was not vapor/watertight. Issued deficiency to make through deck fitting for all exhaust lines watertight in way of port/starboard engines and generator.
Construction/Loadline › Penetrations › Pipe Flange
Issued 30 January 2004
Resolved
make wire penetration watertight in stbd lazarette.
Action required: 705 - Other - as specified
Due 29 February 2004
Resolved 16 September 2004
Electrical › Electric Supply System (service) › Cable
Issued 30 January 2004
Resolved
Re-attach spray shield over bus bar in forward part of starboard engine room.
Action required: 705 - Other - as specified
Due 29 February 2004
Resolved 16 September 2004
Accommodation/Occupational Safety › Cooking Systems
Issued 2 January 2003
Resolved
Provide proposal to MSO San Francisco to eliminate open flame used for cooking/heating trays. LEGACY COMPONENT DESC: Warming trays
Action required: 705 - Other - as specified
Due 3 February 2003
Resolved 16 January 2003
Resolution: Rcvd letter dated 3 Jan 2003 from vessel owner requesting to keep warming trays on board with the addition of several safety factors to their use. Proposal being evaluated.
Electrical › Electric Generation Source (service)
Issued 2 January 2003
Resolved
Provide and install junction boxes for port and starboard shore tie receptacles located above both engine room access hatches. LEGACY COMPONENT DESC: Conductor
Due 16 January 2003
Resolved 15 January 2003
Accommodation/Occupational Safety › Cooking Systems
Issued 16 December 2002
Resolved
Remove all open-flame heating systems (open-flame steam tray warmers) from vessel.
Due 23 December 2002
Resolved 2 January 2003
Resolution: Deficiency closed and re-issued on CG-835 form. See deficiency report for new requirement.
Engineering › Fuel Oil Service System › Valve
Issued 12 November 2002
Resolved
Mark direction of turn for fuel-oil shut-off valve.
Due 12 November 2002
Resolved 12 November 2002
Lifesaving › Visual Distress Signals (General) › Marking
Issued 12 November 2002
Resolved
Mark "distress signals" on distress signals container.
Due 12 November 2002
Resolved 12 November 2002
Construction/Loadline › Structures
Issued 7 November 2002
Resolved
Replace cracked windows, port fwd & central port, in pilot house.
Action required: 705 - Other - as specified
Due 16 January 2003
Resolved 16 January 2003
Lifesaving › Lifebuoys
Issued 7 November 2002
Resolved
Provide corrosion resistant clip & minimum 3' lanyard for lifebuoy and attach lifeline via independent means to lifering.
Due 14 November 2002
Resolved 20 December 2002
Resolution: Provided as required in details.
Lifesaving › Lifejacket/PFD (General)
Issued 7 November 2002
Resolved
Provide method to separate child life jackets in stbd cover box holding 20 adults and 6 child lifejackets. LEGACY COMPONENT DESC: Storage
Due 14 November 2002
Resolved 20 December 2002
Resolution: Provided as required in details.
Engineering › Diesel Engine (propulsion/auxiliary-electric)
Issued 7 November 2002
Resolved
Provide and properly mount overflow expansion tanks for port and stbd engine room and generator rooms.
Due 7 November 2002
Resolved 20 December 2002
Resolution: Provided and mounted expansion tanks.
Engineering › Sea-water System (primary cooling)
Issued 7 November 2002
Resolved
Repair leak to port engine raw water pump. LEGACY COMPONENT DESC: Pump
Due 7 December 2002
Resolved 2 January 2003
Resolution: Vessel has installed new raw water pump.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 7 November 2002
Resolved
Repair loose bolt to port exhaust piping flange. LEGACY COMPONENT DESC: Piping (exhaust)
Due 14 November 2002
Resolved 20 December 2002
Resolution: Repaired as required.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 7 November 2002
Resolved
Repair wasted exhaust lagging in stbd engineroom. LEGACY COMPONENT DESC: Piping (exhaust)
Due 7 December 2002
Resolved 20 December 2002
Resolution: Repaired as required.
Engineering › Bilge Water Management System
Issued 7 November 2002
Resolved
Prove proper operation of bilge suction in bilge below ladies restroom. LEGACY COMPONENT DESC: Piping
Due 16 January 2003
Resolved 16 January 2003
Electrical › Electrical Distribution System (service)
Issued 7 November 2002
Resolved
Properly repair wiring to stbd junction box upper deck fwd. LEGACY COMPONENT DESC: Junction Box
Due 7 December 2002
Resolved 20 December 2002
Resolution: Repaired as required.
Electrical › Electric Supply System (service)
Issued 7 November 2002
Resolved
Remove dead-end wiring stbd lazerette/center fwd pontoon.
Action required: 705 - Other - as specified
Due 7 December 2002
Resolved 2 January 2003
Resolution: Wire has been properly dead-ended into new junction box.
Electrical › Electrical Distribution System (service)
Issued 7 November 2002
Resolved
Properly install and mount junction boxes for 2 exposed connection blocks in each engineroom, 1 block in the bar area, and 1 block in the galley (stbd inboard). LEGACY COMPONENT DESC: Junction Box
Action required: 705 - Other - as specified
Due 7 December 2002
Resolved 2 January 2003
Electrical › Electrical Distribution System (service)
Issued 7 November 2002
Resolved
Remove wiring from exhaust in stbd vent aft, wire runs through fan. LEGACY COMPONENT DESC: Wiring
Due 14 November 2002
Resolved 20 December 2002
Resolution: Removed wiring.
Electrical › Electric Supply System (service)
Issued 7 November 2002
Resolved
Repair/replace shore power cable. LEGACY COMPONENT DESC: Cable
Due 14 November 2002
Resolved 2 January 2003
Resolution: New shore tie connection plug properly installed on shore tie cable.
Electrical › Electric Supply System (service)
Issued 7 November 2002
Resolved
Replace metal wire supports in engineroom.
Due 16 January 2003
Resolved 16 January 2003
Engineering
Issued 14 February 2002
Resolved
make proper repairs to the main steering system actuator support bracket port side. LEGACY COMPONENT DESC: Actuator
Condition: Improper Installation
Due 14 March 2002
Resolved 20 March 2002
Resolution: Repairs completed by welding 2" heavy walled square tubing from steering suport bracket to overhead. Tested steering system, test satisfactory. Cleared requirement.
Construction/Loadline › Hull
Issued 23 January 2002
Resolved
Submit a proposal for maximum wind and sea conditions for this vessels present route. OCMI will review and, within reason, modify Routes and Conditions on COI. In lieu of this option, vessel restricted to 129 passengers until MSC recieves / approves stability calcs for Partially Protected route.
Action required: 705 - Other - as specified
Due 26 March 2002
Resolved 16 April 2002
Engineering › Steering Gear System
Issued 23 January 2002
Resolved
MOVE STARBOARD SIDE CLEVIS PIN HOLE AFT (APPROX .25 INCHES) TO ALLOW FREE MOVEMENT OF RUDDER ARM. COMPLETE AN U/W OPTEST UPON REPAIR TO THE SATISFACTION OF AN ATTENDING MARINE INSPECTOR NLT 22FEB02. LEGACY COMPONENT DESC: Linkage
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 22 February 2002
Resolved 14 February 2002
Resolution: Clevis turned upside down.
Electrical
Issued 23 October 2001
Resolved
REMOVE DEAD END WIRES FROM PORT AND STARBOARD ENGINEROOMS. COMPLETE TO THE SATISFACTION OF AN ATTENDING MARINE INSPECTOR NO LATER THAN 30NOV01.
Condition: Unknown
Due 30 November 2001
Resolved 23 October 2001
Resolution: Dead end wires removed.
Construction/Loadline
Issued 9 October 2001
Resolved
REPAIR DAMAGE TO PORT SIDE AFT WEATHERTIGHT DOOR.
Condition: Unknown
Due 10 November 2001
Resolved 10 November 2001
Resolution: Westhertight door repaired as new.
Electrical
Issued 13 January 1998
Resolved
BRIDGE POWER PANEL - INSTALL BREAKER BLANK TO COVER OPEN SLOT
Condition: Unknown
Due 14 February 2002
Resolved 14 February 2002
Electrical
Issued 13 January 1998
Resolved
REMOVE DEADEND CABLES - PORT AND STBD ENG ROOMS
Condition: Unknown
Due 14 February 2002
Resolved 14 February 2002
Navigation
Issued 13 January 1998
Resolved
MOUNT EMERGENCY RADIO BROADCAST INFORMATION
Condition: Unknown
Due 14 February 2002
Resolved 14 February 2002
Lifesaving
Issued 13 January 1998
Resolved
LABEL LIFEJACKET BAGS - UPPER DECK
Condition: Unknown
Due 14 February 2002
Resolved 14 February 2002
Electrical
Issued 4 December 1996
Resolved
REMOVE DEAD WIRES IN PORT (FORWARD, OUTBOARD SIDE) AND STARBOARD (FWD, INBOARD SIDE) ENGINEROOMS.
Condition: Unknown
Due 14 February 2002
Resolved 14 February 2002
Construction/Loadline
Issued 4 December 1996
Resolved
REPLACE CHECK VALVE ON AFT PICKUP WITHIN THE PORT FORWARD MIDBODY COMPARTMENT.
Condition: Unknown
Due 14 February 2002
Resolved 14 February 2002
Engineering
Issued 4 December 1996
Resolved
PROVIDE FLAME SCREEN FOR FUEL TANK VENT.
Condition: Unknown
Due 4 December 1996
Resolved 4 December 1996
Navigation
Issued 4 December 1996
Resolved
PROVIDE DEVIATION CARD.
Condition: Unknown
Due 14 February 2002
Resolved 14 February 2002
Fire Fighting
Issued 4 December 1996
Resolved
INSTALL PRESSURE GAUGE ON DISCHARGE SIDE OF FIRE PUMP.
Condition: Unknown
Due 14 February 2002
Resolved 14 February 2002
Navigation
Issued 4 December 1996
Resolved
REPAIR ANCHOR LIGHT.
Condition: Unknown
Due 14 February 2002
Resolved 14 February 2002
Lifesaving
Issued 4 December 1996
Resolved
PROVIDE PERMANENT STOWAGE PLACARD FOR 22 ADULT PFD'S STOWED ABOVE THE PILOTHOUSE. ADD "5 CHILDREN" TO TWO COVERS ON AFT UPPER DECK.
Condition: Unknown
Due 14 February 2002
Resolved 14 February 2002
Lifesaving
Issued 26 April 1996
Resolved
ADD REFLECTIVE TAPE TO RING BUOYS
Condition: Unknown
Due 14 February 2002
Resolved 14 February 2002
Engineering
Issued 26 April 1996
Resolved
PORT TACHOMETER BOUNCING - REWIRE WIRING ONTO PROPER TERMINALS
Condition: Unknown
Due 26 April 1996
Resolved 26 April 1996
Lifesaving
Issued 26 April 1996
Resolved
VERIFY AMOUNT OF LIFEJACKETS IN STOWAGE CONTAINERS AND RESTENCIL AS REQUIRED.
Condition: Unknown
Due 14 February 2002
Resolved 14 February 2002
Engineering
Issued 1 March 1996
Resolved
REQUIRE A SET OF PLANS THAT SHOW TRANSMISSION CHANGES AND WEIGHT CHANGES FOR STABILITY PURPOSES
Condition: Unknown
Due 1 March 1996
Resolved 1 March 1996
Engineering
Issued 8 February 1996
Resolved
REPLACE PORT STRUT CUTLASS BEARING.
Condition: Unknown
Due 8 February 1996
Resolved 8 February 1996
Lifesaving
Issued 14 November 1995
Resolved
PLACE GUARDS OVER BOTH ENGINE FLYWHEELS.
Condition: Unknown
Due 5 February 1996
Resolved 5 February 1996
Navigation
Issued 27 January 1995
Resolved
REPAIR HOLE MADE IN PORT RUDDER. CHECK FOR PROPER WELD, MUST BE INSPECTED BEFORE VESSEL RE-ENTERS WATER.
Condition: Unknown
Due 30 January 1995
Resolved 30 January 1995
Construction/Loadline
Issued 27 January 1995
Resolved
MAKE PERMANENT TAGS OR MARK BULKHEAD TO IDENTIFY VALVES FOR BILGE MANIFOLDSFOR BOTH ENGINE ROOMS.
Condition: Unknown
Due 14 February 2002
Resolved 14 February 2002
Engineering
Issued 27 January 1995
Resolved
SERVICE BOTH SCREWS AND PORT SHAFT AND RE-INSTALL. SHALL BE INSPECTED PRIORTO RE-ENTERING THE WATER.
Condition: Unknown
Due 30 January 1995
Resolved 30 January 1995
Construction/Loadline
Issued 27 January 1995
Resolved
SAND BLAST HULL & RENEW BOTTOM PAINT. SHALL BE INSPECTED PRIOR TO LAUNCH.
Condition: Unknown
Due 30 January 1995
Resolved 30 January 1995
Engineering
Issued 27 January 1995
Resolved
REPLACE PORT & STBD CUTLASS BEARINGS. SHALL BE INSPECTED PRIOR TO RE- ENTERING THE WATER.
Condition: Unknown
Due 30 January 1995
Resolved 30 January 1995
Electrical
Issued 1 December 1994
Resolved
PROVIDE DRIP SHIELD FOR LIGHTING PANEL ON BRIDGE.
Condition: Unknown
Due 3 January 1995
Resolved 9 December 1994
Electrical
Issued 1 December 1994
Resolved
CHOCK BATTERY BANKS IN PORT ENGINE ROOM.
Condition: Unknown
Due 9 December 1994
Resolved 9 December 1994
Construction/Loadline
Issued 1 December 1994
Resolved
PROVE PROPER OPERATION OF BILGE ALARMS IN BOTH ENGINE ROOMS.
Condition: Unknown
Due 3 January 1995
Resolved 9 December 1994
Accommodation/Occupational Safety
Issued 1 December 1994
Resolved
PROVIDE PLANS FOR PERMANENT INSTALLATION OF TEMPORARY HEATING SYSTEM ON 2NDDECK. PLANS MUST BE SUBMITTED WITHIN 30 DAYS.
Condition: Unknown
Due 14 February 2002
Resolved 14 February 2002
Electrical
Issued 1 December 1994
Resolved
INSTALL VOLTMETER, AMPMETER, AND HERTZ GAUGES FOR SHIP SERVICE GENERATOR.
Condition: Unknown
Due 3 January 1995
Resolved 3 January 1995
Electrical
Issued 1 December 1994
Resolved
SUBMIT PLANS FOR NEW GENERATOR SET INSTALLATION.
Condition: Unknown
Due 14 February 2002
Resolved 14 February 2002
Fire Fighting
Issued 1 December 1994
Resolved
RECHAREGE ONE SPARE BII DRY CHEM FIRE EXTINGUISHER. VESSEL IS REQUIRED TO CARRY 7 BII AND THIS EXTINGUISHER IS ONE ABOVE THE REQUIRED NUMBER.
Condition: Unknown
Due 3 January 1995
Resolved 3 January 1995
Construction/Loadline
Issued 1 December 1994
Resolved
MAKE MSD DISCHARGE HOSE FROM DECK TO ENGINE ROOM IN WAY OF PORT SIDE VAPOR TIGHT.
Condition: Unknown
Due 14 February 2002
Resolved 14 February 2002
Accommodation/Occupational Safety
Issued 1 December 1994
Resolved
PROVIDE DOCUMENTATION ALLOWING SANX TYPE I MSD TO BE INSTALLED AS PER COASTGUARD. IF NO DOCUMENTATION RETURN SYSTEM AS PER ORIGINAL CG PLAN APPROVAL TO TYPE III OR SUBMIT PLANS TO MODIFY TO TYPE II MSD.
Condition: Unknown
Due 3 January 1995
Resolved 22 December 1994
Engineering
Issued 1 December 1994
Resolved
SUBMIT PLANS TO REWORK VENTS SO THEY LEAD OUTSIDE OF PASSENGER COMPARTMENTS. MODIFICATIONS MAY BE COMPLETED AT NEXT DRY DOCK.
Condition: Unknown
Due 1 December 1994
Resolved 1 December 1994
Lifesaving
Issued 1 December 1994
Resolved
REFASTEN BARREL BOLTS TO FORWARD ACCESS DOORS PORT & STBD. MARK WARNINGS IAW ITEM 13.
Condition: Unknown
Due 3 January 1995
Resolved 3 January 1995
Electrical
Issued 1 December 1994
Resolved
PROTECT FROM WEATHER AND PROPERLY GROUND ALL X-MAS TREE LIGHTING ON 2ND DECK. REMOVE MULTI PLUGS.
Condition: Unknown
Due 3 January 1995
Resolved 3 January 1995
Electrical
Issued 1 December 1994
Resolved
REPAIR HANGING LAMP, PORT SIDE AFT ON 2ND DECK.
Condition: Unknown
Due 3 January 1995
Resolved 9 December 1994
Construction/Loadline
Issued 1 December 1994
Resolved
PROPERLY BLANK-OFF UNUSED KEEL COOLERS FOR BOTH MAIN ENGINES.
Condition: Unknown
Due 3 January 1995
Resolved 3 January 1995
Electrical
Issued 1 December 1994
Resolved
RENEW TO ORIGINAL CONFIGURATION (GLOBES & CAGES) OR REMOVE LIGHT FIXTURES PORT & STBD AFT ON PILOT HOUSE.
Condition: Unknown
Due 3 January 1995
Resolved 9 December 1994
Construction/Loadline
Issued 1 December 1994
Resolved
PROPERLY SEAL WIRING RUNS PIERCING AFT BULKHEAD OF PORT ENGINE ROOM.
Condition: Unknown
Due 3 January 1995
Resolved 3 January 1995
Electrical
Issued 1 December 1994
Resolved
PROVIDE COVER FOR LIGHTING FIXTURE OF WOMENS HEAD.
Condition: Unknown
Due 3 January 1995
Resolved 9 December 1994
Electrical
Issued 1 December 1994
Resolved
PROPERLY TERMINATE OR REMOVE LOOSE ELECTRICAL WIRING.
Condition: Unknown
Due 3 January 1995
Resolved 9 December 1994
Construction/Loadline
Issued 1 December 1994
Resolved
REPLACE GLASS PANEL MAIN DECK, PORT SIDE FORWARD.
Condition: Unknown
Due 3 January 1995
Resolved 3 January 1995
Construction/Loadline
Issued 1 December 1994
Resolved
REPLACE GLASS PANEL, PORTSIDE WHEEL HOUSE.
Condition: Unknown
Due 3 January 1995
Resolved 3 January 1995
Construction/Loadline
Issued 1 December 1994
Resolved
REPLACE GASKET AND PROVE WEATHER TIGHTNESS OF PASSENGER DOORS, PORT & STBD AFT.
Condition: Unknown
Due 3 January 1995
Resolved 3 January 1995
Construction/Loadline
Issued 1 December 1994
Resolved
PROVE PROPER OPERATION OF ALL ELECTRICAL RULE BILGE PUMPS. ENGINE OPERATED BILGE PUMPS OPERATED SAT. THESE PUMPS ARE SECONDARY ONLY.
Condition: Unknown
Due 3 January 1995
Resolved 3 January 1995
Documentation
Issued 1 December 1994
Resolved
PROVIDE FCC STATION LICENSE FOR VESSEL.
Condition: Unknown
Due 3 January 1995
Resolved 10 January 1995
Electrical
Issued 1 December 1994
Resolved
PROPERLY SECURE OVERHEAD LIGHT IN PORT ENGINE ROOM.
Condition: Unknown
Due 3 January 1995
Resolved 9 December 1994
Construction/Loadline
Issued 1 December 1994
Resolved
PROVIDE DOGGING SCREW FOR PORTSIDE AFT WINDOW.
Condition: Unknown
Due 3 January 1995
Resolved 3 January 1995
Lifesaving
Issued 1 December 1994
Resolved
REPLACE LATCH ON STBD, AFT ACCESS DOOR. FOR BOTH ACCESS DOORS, PORT & STBD PROVIDE: A) SAFETY CHAIN ACROSS ENTRANCE B) BARREL BOLTS C) PAINT WARNING SIGN "TO BE OPEN BY AUTHORIZED PERSONNEL ONLY".
Condition: Unknown
Due 3 January 1995
Resolved 3 January 1995
Electrical
Issued 1 December 1994
Resolved
OPERATOR IS TO REQUEST A COPY OF THE APPROVED ELECTRICAL DIAGRAM FOR VESSELFROM COAST GUARD FILES. ELECTRICIAN NEEDS TO TRACE ELECTRICAL SYSTEM AND NOTE CHANGES AND MODS MADE TO SYSTEM. SUBMIT REVISED ELECTRICAL DIAGRAM. MAYBE DONE IN CONJUNCTION WITH ITEM 4.
Condition: Unknown
Due 14 February 2002
Resolved 14 February 2002
Electrical
Issued 1 December 1994
Resolved
PLUG AND COVER EXPOSED WIRING ON BATTERY PANEL ON BRIDGE.
Condition: Unknown
Due 3 January 1995
Resolved 9 December 1994
Electrical
Issued 1 December 1994
Resolved
SEAL HOLE IN SIDE OF MAIN DISTRIBUTION POWER PANEL.
Condition: Unknown
Due 3 January 1995
Resolved 9 December 1994
Construction/Loadline
Issued 1 December 1994
Resolved
PROVIDE NUTS TO DOG DOWN LARGE ENGINE ROOM HATCHES.
Condition: Unknown
Due 3 January 1995
Resolved 9 December 1994
Engineering
Issued 1 December 1994
Resolved
PROPERLY SECURE HOT WATER HEATER.
Condition: Unknown
Due 3 January 1995
Resolved 9 December 1994
Accommodation/Occupational Safety
Issued 1 December 1994
Resolved
SUBMIT PLANS FOR FLOOR HEATING UNITS ON MAIN & 2ND DECK. THERE MUST BE NO WIRE NUTS, NO EXPOSED WIRING OR HEATING ELEMENTS, WIRED PROPERLY (CORDS NOTRUNNING UNDER CARPETING), AND SECURED TO BULKHEADS AND RAILS PROPERLY.
Condition: Unknown
Due 3 January 1995
Resolved 9 December 1994
Construction/Loadline
Issued 1 October 1994
Resolved
HARD PIPE GRAY WATER OVERBOARD PIPING (LOCATED IN PORT E/R COMPARTMENT AND PORT LAZARETTE).
Condition: Unknown
Due 14 February 2002
Resolved 14 February 2002
Construction/Loadline
Issued 1 October 1994
Resolved
INSTALL WATERTIGHT HATCHES TO ALLOW ACCESS TO BALL VALVES INSTALLED IN PORT/STBD ENGINES AND GENERATOR EXHAUST PIPING SYSTEMS. [SEE DRAWINGS IN FILE]
Condition: Unknown
Due 14 February 2002
Resolved 14 February 2002
Engineering
Issued 1 October 1994
Resolved
INSTALL 3" DIAMETER BRASS PIPING IN EXHAUST SYSTEM FOR PORT/STBD ENGINES AND GENERATOR IAW DRAWING GENERATED 10/3/94.
Condition: Unknown
Due 1 October 1994
Resolved 1 October 1994
Construction/Loadline
Issued 1 October 1994
Resolved
PROVE WATERTIGHTNESS OF 3 FORWARDMOST PONTOON VOID SPACES.
Condition: Unknown
Due 14 February 2002
Resolved 14 February 2002
Fire Fighting
Issued 1 October 1994
Resolved
SERVICE ALL FIRE EXTINGUISHERS.
Condition: Unknown
Due 14 October 1994
Resolved 17 October 1994
Engineering
Issued 1 October 1994
Resolved
MARK EXTERIOR OF FUEL TANK TOP INDICATING CONTENTS WITHIN.
Condition: Unknown
Due 1 October 1994
Resolved 1 October 1994
Construction/Loadline
Issued 11 January 1994
Resolved
REPLACE THREE MISSING BOLTS TO ACCESS PLATE ON STARBOARD SIDE FORWARD WATERTIGHT BULKHEAD IN WAY OF MSD HOLDING TANK.
Condition: Unknown
Due 25 January 1994
Resolved 24 January 1994
Documentation
Issued 11 January 1994
Resolved
PROVIDE A VALID COPY OF FCC RADIO OPERATOR PERMIT.
Condition: Unknown
Due 25 January 1994
Resolved 21 January 1994
Lifesaving
Issued 11 January 1994
Resolved
MARK RINGBUOY WITH VESSEL NAME.
Condition: Unknown
Due 25 January 1994
Resolved 24 January 1994
Construction/Loadline
Issued 11 January 1994
Resolved
PROVE EFFECTIVE OPERATION OF THE ENGINE DRIVEN BILGE PUMPING SYSTEM BRANCH LINES TO PORT&STARBOARD STEERING SPACES, PORT&STARBOARD ENGINE SPACES, GENERATOR SPACE AND CENTERLINE SPACE FORWARD OF FRESSH WATER TANK. NO PASSENGERS MAY BE CARRIED UNTIL THIS REQUIREMENT IS MET.
Condition: Unknown
Due 25 January 1994
Resolved 24 January 1994
Documentation
Issued 8 October 1993
Resolved
PROVIDE DIAGRAM OF ENGINE EXHAUST SYSTEM; INCLUDING COMPONENTS, MATERIALS, SIZES AND LOCATION.
Condition: Unknown
Due 14 February 2002
Resolved 14 February 2002
Engineering
Issued 8 October 1993
Resolved
INSTALL PROPER SUPPORT PIPING FOR EXHAUST COOLING WATER SUPPLY.
Condition: Unknown
Due 22 October 1993
Resolved 22 October 1993
Engineering
Issued 8 October 1993
Resolved
INSTALL VISUAL ALARM INDICATORS ON BRIDGE TO INDICATE LOSS OF COOLING WATERTO THE EXHAUST SYSTEMS FOR BOTH ENGINES.
Condition: Unknown
Due 22 October 1993
Resolved 22 October 1993
Engineering
Issued 8 October 1993
Resolved
PROVIDE LAGGING ON EXPOSED SURFACES OF EXHAUST SYSTEM AND SIPHON LOOP.
Condition: Unknown
Due 22 October 1993
Resolved 22 October 1993
Engineering
Issued 8 October 1993
Resolved
Make permanent proper repairs to exhaust system on port MDE. Prove proper operation of MDE. Clean oil from bilges from port pontoon. Vessel shall not carry passengers until above repairs have been affected and tested in presence of CG marine inspector.
Condition: Unknown
Due 15 October 1993
Resolved 15 October 1993
Construction/Loadline
Issued 17 November 1992
Resolved
PROVE BILGE SUCTION IN FWD CENTER COMPARTMENT.
Condition: Unknown
Due 14 February 2002
Resolved 14 February 2002
Electrical
Issued 17 November 1992
Resolved
SECURE BASE BOARD HEATER WIRE CONNECTIONS WITH UL APPROVED COMPRESSION FITTINGS OR SOLDERED CONNECTIONS.
Condition: Unknown
Due 14 February 2002
Resolved 14 February 2002
Electrical
Issued 17 November 1992
Resolved
REMOVE OR SECURE PROPERLY, LOOSE WIRES IN FOLLOWING LOCATIONS: 1) CENTER FORWARD COMPARTMENT, 2) PORT AFT COMPARTMENT, AND 3) STARBOARD ENGINE COMPARTMENT.
Condition: Unknown
Due 14 February 2002
Resolved 14 February 2002
Lifesaving
Issued 17 November 1992
Resolved
STOW CHILD SIZE LIFE PRESERVERS PHYSICALLY SEPARATED FROM ADULT PFD'S.
Condition: Unknown
Due 14 February 2002
Resolved 14 February 2002
Fire Fighting
Issued 17 November 1992
Resolved
INSTALL BRASS OR BRONZE FITTING BETWEEN FIRE NOZZLES AND HOSES.
Condition: Unknown
Due 14 February 2002
Resolved 14 February 2002
Engineering
Issued 28 January 1992
Resolved
DOUBLE NUT THROTTLE CABLES ON MAIN ENGINES.
Condition: Unknown
Due 28 January 1992
Resolved 28 January 1992
Accommodation/Occupational Safety
Issued 28 January 1992
Resolved
DRILL STOP AND WELD CRACK LOWER FORWARD CORNER AFT STARBOARD DOOR.
Condition: Unknown
Due 14 February 2002
Resolved 14 February 2002
Electrical
Issued 28 January 1992
Resolved
PROVIDE GLASS GLOBE AND GUARD FOR AFT LIGHT IN GENERATOR SPACE.
Condition: Unknown
Due 14 February 2002
Resolved 14 February 2002
Engineering
Issued 28 January 1992
Resolved
TIE UP LOOSE LINE AND TOGGLE SWITCH FOR PUMP IN GENERATOR SPACE.
Condition: Unknown
Due 28 January 1992
Resolved 28 January 1992
Construction/Loadline
Issued 16 February 1991
Resolved
REPAIR WELD ON SOFT PATCH IN 2ND VOID PORT SIDE TO PASS SOAP TEST. (FIX PIN HOLE LEAK IN WATER TIGHT BULKHEAD BETWEEN 2ND AND 3RD PORT VOIDS.)
Condition: Unknown
Due 14 February 2002
Resolved 14 February 2002
Documentation
Issued 28 November 1990
Resolved
POST EMERGENCY CHECK OFF LIST.
Condition: Unknown
Due 14 February 2002
Resolved 14 February 2002
Electrical
Issued 28 November 1990
Resolved
REPAIR BATTERY BOX, STBD ENGINE ROOM, INBOARD, FOR GENERATOR STARTING.
Condition: Unknown
Due 14 February 2002
Resolved 14 February 2002
Engineering
Issued 28 November 1990
Resolved
PERMANENTLY REPAIR PORT AND STARBOARD MAIN DIESEL ENGINE EXHAUST SYSTEM IN WAY OF COOLING WATER INJECTOR.
Condition: Unknown
Due 28 November 1990
Resolved 28 November 1990
Navigation
Issued 28 November 1990
Resolved
PROVIDE COMPASS DEVIATION CARD.
Condition: Unknown
Due 14 February 2002
Resolved 14 February 2002
Engineering
Issued 28 November 1990
Resolved
REPAIR PORT STEERING ROOM BILGE ALARM.
Condition: Unknown
Due 28 November 1990
Resolved 28 November 1990
Engineering
Issued 28 November 1990
Resolved
REPAIR PORT ENGINE ROOM ELECTRIC BILGE PUMP FLOAT SWITCH.
Condition: Unknown
Due 28 November 1990
Resolved 28 November 1990
Engineering
Issued 28 November 1990
Resolved
POST BILGE SYSTEM SCHEMATIC DIAGRAM.
Condition: Unknown
Due 28 November 1990
Resolved 28 November 1990
Accommodation/Occupational Safety
Issued 28 November 1990
Resolved
REAIR PORT ENGINE ROOM VENTILATION BLOWER.
Condition: Unknown
Due 14 February 2002
Resolved 14 February 2002
Engineering
Issued 28 November 1990
Resolved
STENCIL REMOTE FUEL SHUT OFF.
Condition: Unknown
Due 28 November 1990
Resolved 28 November 1990
Construction/Loadline
Issued 2 January 1990
Resolved
1. GRIND OUT AND REWELD OUTBOARD BUTT WELD IN THIRD VOID FROM BOW (JUST AFT OF THE ELEVENTH FRAME FROM THE COLLISION BULKHEAD) IN THE PORT HULL.
Condition: Unknown
Due 14 February 2002
Resolved 14 February 2002
Engineering
Issued 1 December 1989
Resolved
REPAIR ALL BILGE ALARMS ON BRIDGE, (12), OR REMOVE. NOT PROPERLY IDENTIFIED SINCE BULKHEADS INSTALLED. IDENTIFY LOCATIONS.
Condition: Unknown
Due 1 December 1989
Resolved 1 December 1989
Documentation
Issued 1 December 1989
Resolved
PROVIDE A CORRECTED GENERAL ARRANGEMENT DRAWING SHOWING CORRECT LOCATION OFALL WATERTIGHT BULKHEADS.
Condition: Unknown
Due 14 February 2002
Resolved 14 February 2002
Engineering
Issued 1 December 1989
Resolved
INSTALL CHECK VALVE AND STRAINER ON BILGE SUCTION TO STBD AFT STEERING GEARVOID.
Condition: Unknown
Due 1 December 1989
Resolved 1 December 1989
Engineering
Issued 1 December 1989
Resolved
INSTALL BILGE PIPING AND ASSOCIATED CHECK VALVE AND STRAINER FOR PORT AFT STEERING GEAR VOID.
Condition: Unknown
Due 1 December 1989
Resolved 1 December 1989
Engineering
Issued 1 December 1989
Resolved
SHOW THAT VALVES FOR NEW DOUBLE BOTTOM BILGE SUCTION LINES ARE STOP CHECK VALVES OR INSTALL STOP CHECK VALVES AS PER APPROVED PLAN.
Condition: Unknown
Due 1 December 1989
Resolved 1 December 1989
Construction/Loadline
Issued 1 December 1989
Resolved
REMOVE UNUSED PIPE, PLUG, AND WELD AT BULKHEAD IN STBD HULL, AFT VOID, BELOW WOMEN'S HEAD.
Condition: Unknown
Due 14 February 2002
Resolved 14 February 2002
Engineering
Issued 1 December 1989
Resolved
PROVIDE BILGE PIPING DIAGRAM AND INSTRUCTIONS FOR OPERATION OF THE BILGE SYSTEM. POST AT ENTRANCE TO EACH ENGINEROOM, GENERATOR ROOM, AND ABOVE REMOTE VALVE CONTROLS IN BAR.
Condition: Unknown
Due 1 December 1989
Resolved 1 December 1989
Engineering
Issued 1 December 1989
Resolved
LOCATE FUEL TANK VENT AND INSTALL FLAME SCREEN IF REQUIRED. 46CFR182.20-35
Condition: Unknown
Due 1 December 1989
Resolved 1 December 1989
Engineering
Issued 1 December 1989
Resolved
INSTALL A SEA VALVE TO THE CENTER HULL FOREPEAK VOID ELECTRIC BILGE PUMP OVERBOARD DISCHARGE. 46CFR171.119(C).
Condition: Unknown
Due 1 December 1989
Resolved 1 December 1989
Construction/Loadline
Issued 1 December 1989
Resolved
INSTALL DRAIN OR LIMBER HOLES IN HIGH DOUBLE BOTTOM FRAME, CENTER HULL, APPROXIMATELY 23' AFT OF BOW.
Condition: Unknown
Due 14 February 2002
Resolved 14 February 2002
Engineering
Issued 1 December 1989
Resolved
INSTALL BULKHEAD STOP VALVES IN EACH OF THREE HULLS FOR BILGE SUCTION LINESPASSING THROUGH COLLISION BULKHEAD. 46CFR182.25-5(D).
Condition: Unknown
Due 1 December 1989
Resolved 1 December 1989
Construction/Loadline
Issued 1 December 1989
Resolved
INSTALL ACCESS THROUGH BULKHEAD AT 6TH FRAME AFT OF COLLISION BULKHEAD IN PORT HULL TO 3RD VOID. ACCESS MUST BE A WATERTIGHT TYPE.
Condition: Unknown
Due 14 February 2002
Resolved 14 February 2002
Construction/Loadline
Issued 1 December 1989
Resolved
INSTALL A NON-WATERTIGHT ACCESS TO 2' VOID IN STARBOARD HULL BENEATH WOMEN'S HEAD SO THAT SPACE MAY BE INSPECTED. ACCESS SHOULD BE THROUGH AFT MOST BULKHEAD.
Condition: Unknown
Due 14 February 2002
Resolved 14 February 2002
Construction/Loadline
Issued 1 December 1989
Resolved
INSTALL A WATERTIGHT HATCH THROUGH MAIN DECK INTO CENTER HULL AFT VOID TO ALLOW FOR INSPECTION. ALSO INSTALL APPROPRIATE BILGE SUCTION FOR THIS SPACE.
Condition: Unknown
Due 14 February 2002
Resolved 14 February 2002
Accommodation/Occupational Safety
Issued 1 December 1989
Resolved
INSTALL A SEA VALVE FOR SINK DRAIN IN PORT HULL AFT STEERING VOID. NOTE: DRAIN MUST BE HARD PIPED THROUGH WATERTIGHT BULKHEAD. 46CFR182.40-1.
Condition: Unknown
Due 14 February 2002
Resolved 14 February 2002
Construction/Loadline
Issued 1 December 1989
Resolved
MAKE PERMANENTLY WATERTIGHT ALL FOUR NEW WATERTIGHT BULKHEADS BY WELDING AND APPROPRIATE WATERTIGHT THROUGH BULKHEAD CONNECTIONS.
Condition: Unknown
Due 14 February 2002
Resolved 14 February 2002
Engineering
Issued 1 December 1989
Resolved
REPAIR KEEL COOLER LEAK, PORT SIDE OUTBOARD, IN STEERING COMPARTMENT WHERE NEW BULKHEAD WAS INSTALLED.
Condition: Unknown
Due 1 December 1989
Resolved 1 December 1989
Accommodation/Occupational Safety
Issued 1 December 1989
Resolved
SUBMIT PLANS FOR INSTALLATION OF VENT SYSTEM IN GENERATOR SPACE AND INSTALLTO APPROVED PLAN. 46CFR182.20-45
Condition: Unknown
Due 14 February 2002
Resolved 14 February 2002
Accommodation/Occupational Safety
Issued 1 December 1989
Resolved
CHANGE ENGINEROOM VENTS SO THAT THE LOWER VENT IN THE SPACE IS THE EXHAUST.46CFR182.20-45
Condition: Unknown
Due 14 February 2002
Resolved 14 February 2002
Engineering
Issued 1 December 1989
Resolved
REPAIR/REPLACE STOP VALVE FOR STBD AFT STEERING VOID BILGE SUCTION. MAINTAIN SUCTION PIPE CAPPED OR PLUGGED UNTIL REPAIRED.
Condition: Unknown
Due 1 December 1989
Resolved 1 December 1989
Electrical
Issued 19 January 1989
Resolved
PROPERLY SECURE LIGHT FIXTURE IN STBD E/R.
Condition: Unknown
Due 14 February 2002
Resolved 14 February 2002
Construction/Loadline
Issued 19 January 1989
Resolved
ATTACH BITTER END OF ANCHOR CHAIN TO THE VESSEL.
Condition: Unknown
Due 14 February 2002
Resolved 14 February 2002
Electrical
Issued 19 January 1989
Resolved
MAKE PROPER DEAD END CONNECTIONS USING JUNCTION BOXES OR REMOVE ALL OPEN ENDED WIRING IN BOTH ENGINE CMPTS AND GEN CMPT.
Condition: Unknown
Due 14 February 2002
Resolved 14 February 2002
Fire Fighting
Issued 19 January 1989
Resolved
PROVIDE ADDITIONAL BII EXTINGUISHER FOR UPPER DECK PASSENGER AREA.
Condition: Unknown
Due 14 February 2002
Resolved 14 February 2002
Deck/Cargo
Issued 19 January 1989
Resolved
SUBMIT PLANS FOR BILGE SYSTEM FOR 3 NEW DOUBLE BOTTOM CMPTS.
Condition: Unknown
Due 14 February 2002
Resolved 14 February 2002
Electrical
Issued 19 January 1989
Resolved
COVER OPENINGS IN 2 CIRCUIT BREAKER PANELS BEHIND BAR WITH MMETAL OR PLASTIC INSTEAD OF DUCT TAPE.
Condition: Unknown
Due 14 February 2002
Resolved 14 February 2002
Navigation
Issued 19 January 1989
Resolved
DOUBLE-NUT WITH LOCK WASHER IN BETWEEN OR DRILL AND COTTER PIN RUDDER POST TO CROSS MEMBER CONNECTIONS AND RAM TO CROSS MEMBER CONNECTION.
Condition: Unknown
Due 14 February 2002
Resolved 14 February 2002
Engineering
Issued 19 January 1989
Resolved
INSTALL ALARM IN PILOTHOUSE INDICATING LOSS OF COOLING WATER TO ENGINE EXHAUSTS FOR BOTH ENGINES.
Condition: Unknown
Due 19 January 1989
Resolved 19 January 1989
Construction/Loadline
Issued 19 January 1989
Resolved
SUBMIT OUTBOARD PROFILE AND INBOARD PROFILE PLANS FOR ALL PONTOONS DEPICTING LOCATION OF ALL WT BKHDS AND NEW FULL LOAD WATERLINE AS DETERMINED DURING STABILITY TEST TO PROVE COMPLIANCE WITH 46CFR171.043.
Condition: Unknown
Due 14 February 2002
Resolved 14 February 2002
Deck/Cargo
Issued 19 January 1989
Resolved
INSTALL STRAINERS ON END OF BILGE SUCTIONS(3) FOR NEW DOUBLE BOTTOMS.
Condition: Unknown
Due 14 February 2002
Resolved 14 February 2002
Construction/Loadline
Issued 19 January 1989
Resolved
INSTALL STRIKER PLATES UNDER SOUNDING TUBES(3) FOR NEW DOUBLE BOTTOMS.
Condition: Unknown
Due 14 February 2002
Resolved 14 February 2002
Construction/Loadline
Issued 19 January 1989
Resolved
INSTALL ACCESS OPENINGS EVERY 5-6 FT ALONG LENGTH OF CENTER PONTOON TO FACILITATE INSPECTION OF NEW DOUBLE BOTTOMS.
Condition: Unknown
Due 14 February 2002
Resolved 14 February 2002
Documentation
Issued 19 January 1989
Resolved
PROVIDE VALID FCC SAFETY CERT.
Condition: Unknown
Due 14 February 2002
Resolved 14 February 2002
Lifesaving
Issued 19 January 1989
Resolved
PROVIDE 1 ADDITIONAL CHILD PFD TO BRING TOTAL ONBOARD TOP 17.
Condition: Unknown
Due 14 February 2002
Resolved 14 February 2002
Lifesaving
Issued 19 January 1989
Resolved
STENCIL LIFE JACKET STOWAGE LOCKERS.
Condition: Unknown
Due 14 February 2002
Resolved 14 February 2002
Accommodation/Occupational Safety
Issued 19 January 1989
Resolved
REMOVE EXISTING RUBBER DSCH HOSES AND BLANK OFF VENT LINE HULL PENETRATION BOTH PORT AND STBD SEWAGE TANKS. A PROPER VENT MUST BE INSTALLED TERMINATING ABOVE THE WEATHERDECK.
Condition: Unknown
Due 14 February 2002
Resolved 14 February 2002
Accommodation/Occupational Safety
Issued 19 January 1989
Resolved
REMOVE OVBD DSWCH PIPING FROM PUMP INSIDE BOTH PORT AND STBD SEWAGE CMPT.
Condition: Unknown
Due 14 February 2002
Resolved 14 February 2002
Accommodation/Occupational Safety
Issued 19 January 1989
Resolved
BLANK OFF PIPE NIPPLE WITH CHECK VALVE ATTACHED TO ONE END ONE IN PORT SEWAGE TANK ONE IN STBD.
Condition: Unknown
Due 14 February 2002
Resolved 14 February 2002
Engineering
Issued 19 January 1989
Resolved
INSTALL FLAME SCREEN FOR FUEL TANK VENT.
Condition: Unknown
Due 19 January 1989
Resolved 19 January 1989
Construction/Loadline
Issued 19 January 1989
Resolved
INSTALL SKIN VALVES FOR BILGE PUMP OVBDS IN BOTH ER CMPTS.
Condition: Unknown
Due 14 February 2002
Resolved 14 February 2002
Construction/Loadline
Issued 19 January 1989
Resolved
HARD PIPE BIGE PUMP OVBD LINES,BOTH ENGINE ROOMS.
Condition: Unknown
Due 14 February 2002
Resolved 14 February 2002
Accommodation/Occupational Safety
Issued 19 January 1989
Resolved
INSTALL OVBD DSCH VALVES FOR THR HEAD SINK OVBD,BOTH PORT AND STBD SEWAGE CMPTS,ALSO REPLACE RUBBER LINE WITH METAL.
Condition: Unknown
Due 14 February 2002
Resolved 14 February 2002
Electrical
Issued 19 January 1989
Resolved
HARD PIPE GEN RAW WATER COOLING LINE FROM SKIN VALVE TO GEN AND GEN TO EXHAUST LINE.
Condition: Unknown
Due 14 February 2002
Resolved 14 February 2002
Engineering
Issued 19 January 1989
Resolved
HARD PIPE EXHAUST COOLING WATER SUPPLY LINE, BOTH ENGINES.
Condition: Unknown
Due 19 January 1989
Resolved 19 January 1989
Accommodation/Occupational Safety
Issued 28 October 1988
Resolved
1 INSTALL BULWARK, CHAIN LINK FENCING, WIRE MESH OR THE EQUIVALENT ON THE RAIL ON THE 2ND DECK. (THE SPACE BELOW THE RAIL)
Condition: Unknown
Due 14 February 2002
Resolved 14 February 2002
Accommodation/Occupational Safety
Issued 3 May 1988
Resolved
INSTALL PLACARD ON UPPER DECK TO DISPLAY MAXIMUM NUMBER OF PERSONS ALLOWED AT 94.
Condition: Unknown
Due 14 February 2002
Resolved 14 February 2002
Engineering
Issued 6 November 1987
Resolved
LOCATE FUEL TANK VENT AND INSTALL FLAME SCREEN IF NECESSARY.
Condition: Unknown
Due 6 November 1987
Resolved 6 November 1987
Accommodation/Occupational Safety
Issued 6 November 1987
Resolved
PRIOR TO COMPLETION NEXT VESSEL DRYDOCKING, CLEAN OUT SEWAGE TANK AND REMOVE OR PERMANENTLY SEAL MSD OVERBOARD DISCHARGE IF APPLICABLE.
Condition: Unknown
Due 14 February 2002
Resolved 14 February 2002
Construction/Loadline
Issued 6 November 1987
Resolved
INSTALL VENTILATION TO MACHINERY SPACES. ONE VENT EXTENDING TO JUST ABOVE THE BILGE. INSTALL IN BOTH PORT AND STBD MAIN ENGINES AND CENTERLINE GENERATOR SPACE.
Condition: Unknown
Due 14 February 2002
Resolved 14 February 2002
Documentation
Issued 6 November 1987
Resolved
PROVIDE FCC RADIOTELEPHONY CERTIFICATE AND FCC RADIO STATION LICENSE.
Condition: Unknown
Due 14 February 2002
Resolved 14 February 2002
Accommodation/Occupational Safety
Issued 6 November 1987
Resolved
SHIM AND PERMANENTLY MOUNT STBD FRESH WATER PUMP.
Condition: Unknown
Due 14 February 2002
Resolved 14 February 2002
Engineering
Issued 6 November 1987
Resolved
PERMANENTLY SECURE MAIN ENGINE BELT GUARD PORT AND STBD MAIN ENGINES.
Condition: Unknown
Due 6 November 1987
Resolved 6 November 1987
Electrical
Issued 6 November 1987
Resolved
REPLACE MISSING GLASS GLOBES AND GUARDS TO LIGHTING.
Condition: Unknown
Due 14 February 2002
Resolved 14 February 2002
Construction/Loadline
Issued 6 November 1987
Resolved
REMOVE WASTE OIL AND CLEAN OUT AFT CENTERLINE VOID.
Condition: Unknown
Due 14 February 2002
Resolved 14 February 2002