← All vessels
SANTA ROSA II
SANTA ROSA II is a 1981 passenger vessel (inspected). The Coast Guard has recorded 77 inspections since 1985, most recently in May 2026, along with 268 deficiencies — 2 with no resolution recorded — and 2 operational controls.
Records from 1985 to 2026. Most recent: inspection, 1 May 2026.
- Built
- 1981
- Last inspected
- 1 May 2026
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 268 recorded · 2 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
643232
WDE6039
228915
Flag
UNITED STATES
303621000
Maury page id
psix-228915
Inspections, by type
…with no type recorded3
…past their stated due date2
Years with a record
37 calendar years (1985–2026)
The 77 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Tonnage as PSIX records it18 - Simplified, Gross Ton
14 - Simplified, Net Ton
14 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
WDL2451MMSI 303621000 · active · compulsorily equipped · granted 10 September 2019, expires 10 September 2029
WDF2005MMSI 368491000 · expired · compulsorily equipped · granted 1 September 2009, cancelled 2 November 2019
WDE6039MMSI 303621000 · expired · compulsorily equipped · granted 28 August 2008, cancelled 3 November 2018
WCH4051MMSI not assigned · expired · compulsorily equipped · granted 26 May 1994, cancelled 1 August 2004 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 77
1 May 2026
Administrative Inspection
Administrative · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 8368354
1 July 2025
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 8170903
8 August 2024
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 7976750
7 March 2024
Hull Examination · Examination of Repairs
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 7875833
6 June 2023
Annual Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 7710206
5 December 2022
Type not recorded
No type recorded · Maritime Safety & Security Team Honolulu (91107) · Activity 7608840
19 April 2022
COI Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 7433658
29 March 2022
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 7421116
1 October 2020
Administrative Inspection
Administrative · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 7072950
3 April 2020
Drydock Exam
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 6934894
2 July 2019
Deficiency Check · COI Inspection · DAPI Audit
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 6734058
1 October 2018
Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 6552810
13 March 2018
Examination of Repairs · Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 6371488
11 December 2017
Administrative Inspection
Administrative · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 6321957
13 October 2017
Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 6287319
4 May 2017
Administrative Inspection
Administrative · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 6138500
7 September 2016
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 5994002
10 May 2016
Administrative Inspection
Administrative · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 5873141
1 March 2016
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 5824472
5 March 2014
Administrative Inspection · Examination of Repairs · Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 4810096
6 July 2012
Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 4372150
13 June 2012
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 4342420
17 September 2010
DAPI Audit
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3886807
25 March 2010
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 3704038
19 March 2010
Deficiency Check · Drydock Exam
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 3700073
14 July 2009
COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 3533948
27 March 2009
DAPI Audit
Administrative · U.S. COAST GUARD FORCES MICRONESIA/SECTOR GUAM · USCG Oceania District (CGD-O) · Activity 3623590
2 June 2008
Drydock Exam · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 3210413
12 July 2007
Annual Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2929550
14 August 2006
Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2746411
3 July 2006
Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2698986
27 June 2006
Internal Structural Exam · Annual Inspection · Hull Examination
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2639134
11 October 2005
Annual Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2512391
10 June 2005
Type not recorded
No type recorded · USCGC GALVESTON ISLAND (WPB 1349) · USCG Oceania District (CGD-O) · Activity 2390932
12 May 2005
Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2355581
12 November 2004
Administrative Inspection
Administrative · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2246489
22 September 2004
Administrative Inspection
Administrative · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2201782
14 July 2004
Hull Examination · COI Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 2039740
29 October 2003
MARPOL Annex V Examination · Annual Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 1945604
31 January 2003
In-Service Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 1737742
28 December 2002
Deficiency Check
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 1723543
13 November 2002
Administrative Inspection
Administrative · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 1704597
4 October 2002
COI Inspection
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 1684835
15 March 2002
Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Saipan · USCG Oceania District (CGD-O) · Activity 1494259
18 October 2001
Re-Inspection · Administrative Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1074677
26 October 2000
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1055236
27 September 2000
Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1361732
25 April 2000
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 816819
28 March 2000
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 816569
17 March 2000
Hull Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1361347
26 January 2000
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 814326
12 January 2000
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1048006
3 November 1999
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 804590
18 October 1999
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1123831
16 September 1999
MARPOL Annex V Examination · COI Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1361124
28 October 1998
Deficiency Check
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 803348
28 September 1998
Re-Inspection · MARPOL Annex V Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1381343
9 March 1998
Hull Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 787249
12 October 1997
Re-Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1364397
2 July 1997
Administrative
Administrative · MSO GUAM · USCG Oceania District (CGD-O) · Activity 779685
11 October 1996
COI Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 848131
2 October 1996
Administrative
Administrative · MSO GUAM · USCG Oceania District (CGD-O) · Activity 833581
3 December 1995
Hull Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1078187
11 October 1995
Re-Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 877937
11 October 1994
Re-Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1141087
6 January 1994
Hull Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1162228
13 October 1993
COI Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1146480
22 December 1992
Administrative
Administrative · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1137428
22 October 1992
Re-Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 950493
25 October 1991
Re-Inspection · Hull Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1008268
27 September 1991
Administrative
Administrative · MSO GUAM · USCG Oceania District (CGD-O) · Activity 934657
12 October 1990
COI Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1234107
27 April 1989
Hull Examination
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 933593
4 January 1989
Type not recorded
No type recorded · MSO GUAM · USCG Oceania District (CGD-O) · Activity 1045136
1 November 1988
Re-Inspection
Physical examination · MSO GUAM · USCG Oceania District (CGD-O) · Activity 889057
15 October 1987
COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1015470
12 December 1985
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1304994
Deficiency record · 268
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 9 August 2026
No resolution recorded
To maintain a valid Certificate of Inspection, the operator must complete the annual inspection within the periods specified in § 176.500(b)(1) and the Certificate of Inspection must be endorsed. The new owner/operator failed to complete an annual inspection within the 90 day annual window.
The vessel's 90 day annual window expired on August 9, 2026.
The COI was voided on this date.
46 CFR 176.502
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 1 May 2026
No resolution recorded
The owner or managing operator shall make a vessel available for drydock examinations, internal structural examinations, and underwater surveys (UWILD) required by this section. A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years.
Vessel is due for a hull examination no later than April 30, 2026. Issued 01 CG-835 restricting passenger operations until a hull examination is completed.
46 CFR § 176.600
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 1 July 2025
Resolved
A submersible electric bilge pump may be used as a power bilge pump required by Table 182.520(a) only on a vessel of not more than 19.8 meters (65 feet) in length carrying not more than 49 passengers, other than a ferry, provided that: The pump discharge line is suitably supported and a positive shutoff valve is installed at the hull penetration.
The discharge piping on the stbd engine compartment bilge pump and lazarette bilge pump was found disconnected at the pump. The port and stbd engine compartment bilge piping is also missing a positive shut off valve at the skin of the vessel.
46 CFR 182.520
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 1 July 2025
Resolved
A vessel on which a pre-engineered fixed gas fire extinguishing system is installed must have the following equipment at the operating station:
(1) A light to indicate discharge;
(2) An audible alarm that sounds upon discharge; and
(3) A means to reset devices used to automatically shut down ventilation systems and engines as required by paragraph (a)(3) of this section.
The port and stbd main engine pre-engineered fixed gas fire extinguishing systems were tested and the marine inspector found that the audible alarm and means to reset devices used to shut down the engine are inoperable.
46 CFR 181.420
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 1 July 2025
Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted in the vicinity of the vent.
The port engine compartment, protected by a fixed gas extinguishing system, has one inoperable ventilation closure located aft of the space. The closure is frozen open.
46 CFR 182.465
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 1 July 2025
Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating.
The visual indicator for the port side engine compartment bilge pump is inoperable.
46 CFR 182.530
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 July 2025
Resolved
Electrical equipment on a vessel must be installed and maintained to the satisfaction of the OCMI.
The port and starboard main engine starting electrical conductors were found installed in the bilge and unsupported.
46 CFR 183
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 July 2025
Resolved
Each connection to a conductor or terminal part of a conductor must be made within an enclosure and have either:
(1) A pressure type connector on each conductor;
(2) A solder lug on each conductor;
(3) A splice made with a pressure type connector to a flexible lead or conductor; or
(4) A splice that is soldered, brazed, or welded to a flexible lead or conductor.
Electrical conductors in the lazarette and engine compartments were found with screw-type wire connectors. These conductors are required to have a pressure type connector and shall be made watertight using a shrink wrap.
46 CFR 183.340
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 July 2025
Resolved
Each battery must be located as high above the bilge as practicable, secured to protect against shifting with the roll and pitch of the vessel, and free from exposure to water splash or spray.
The stbd main engine battery tray is damaged and the battery is not secured from movement.
46 CFR 183.350
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 1 July 2025
Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the International and Inland Navigation Rules, except that a vessel of more than 19.8 meters (65 feet) in length must also have navigation lights that meet UL 1104, “Standards for Marine Navigation Lights,” or other standard specified by the Commandant.
The port side navigation light housing was found painted over and the housing must be replaced.
46 CFR 183.420
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 July 2025
Resolved
At each inspection for certification and at every other vessel inspection all observed unsafe practices, fire hazards, and other hazardous situations must be corrected and all required guards and protective devices must be in satisfactory condition.
The owner admitted to using an open flame grill for food service onboard to passengers. The use of an open flame creates a fire hazard onboard due to the fiberglass hull and is not permitted.
46 CFR 176.830
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 1 July 2025
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. When repairs are made during an emergency, the owner, managing operator, or master shall notify the OCMI as soon as practicable after such repairs or alternations are made.
Wood decay was observed on the overhead beam stbd side immediately aft of the passenger embarkation. Additional wood decay and termites were observed in the wood installed on the side shell used to support the overhead beam. Make repairs IAW good marine practice.
46 CFR 176.700
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 8 August 2024
Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted in the vicinity of the vent.
The vertical exhaust duct discharge opening for each engine space was not modified or designed with a closing device. The crew are unable to close ventilation in the event the pre-engineered fixed fire extinguishing system is used.
46 CFR 182.465 (h)
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 8 August 2024
Resolved
Except when in the judgment of the cognizant OCMI the operation of a vessel does not present one of the hazards listed, the emergency instruction placard should contain at least the applicable portions of the “Recommended Emergency Check Off List” listed in § 185.25-5.
The Emergency Check Off List does not include instructions for operating the fire pump or using the fire pump.
46 CFR 185.25-1(b)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 8 August 2024
Resolved
Gages to indicate cooling water discharge temperature and lube oil pressure shall be provided for all propulsion engines and located to be in view of the operator.
The oil and temp gauges are inoperable on the port main engine.
46 CFR 182.15-5(b)
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 8 August 2024
Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew.
A first-aid kit may be considered acceptable if it meets all of the requirements of ISO 18813:2006(E) paragraph 4.12, except that it does not contain the burn preparations. It must be clearly marked on the first-aid kit that it does not include the burn preparations.
The first aid kit does not comply with the requirements of ISO 18813:2006(E).
46 CFR 184.710
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 August 2024
Resolved
At least one ring life buoy must be fitted with a lifeline. If more than one ring life buoy is carried, at least one must not have a lifeline attached. Each lifeline on a ring life buoy must:
(1) Be buoyant;
(2) Be of at least 18.3 meters (60 feet) in length;
(3) Be non-kinking;
(4) Have a diameter of at least 7.9 millimeters ( 5/16 inch);
(5) Have a breaking strength of at least 5 kilonewtons (1,124 pounds); and
(6) Be of a dark color if synthetic, or of a type certified to be resistant to deterioration from ultraviolet light.
The ring buoy's life line was less than 60'.
46 CFR 180.70(c)
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 8 August 2024
Resolved
Where fire extinguishing equipment are installed but not required, the system or equipment shall meet the requirements of this part.
The vessel is equipped with two fire pumps that are operated off of each engine. The stbd fire pump was inoperable due to flexible piping that was too short and fell off during a pressure test of the system. The port fire pump was found to be operational.
46 CFR 181.05-5
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 6 June 2023
Resolved
The owner or managing operator must provide satisfactory evidence of the required servicing of the fixed fire suppression system to the attending Coast Guard marine Inspector. If any of the equipment or records have not been properly maintained, a qualified servicing may be required to perform the required inspections, maintenance procedures, and hydrostatic pressure tests. The vessel pre-engineered fixed fire suppression system has not been properly been maintained.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 6 June 2023
Resolved
No marine employer shall engage or employ any individual to serve as a crew member unless the individual passes a chemical test for dangerous drugs for that employer.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 6 June 2023
Resolved
vessel port MDE tachometer is not operable, vessel rep either need to remove the tachometer or conduct permanent repairs to bring the tachometer back in operation.
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 6 June 2023
Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician in accordance with § 80.59 once every five years.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 April 2022
Resolved
Vessel new crew was not properly screened for drugs prior to hiring.
10 - Safety of Navigation › N/A - No Subsystem › Navigation bridge visibility
Issued 19 April 2022
Resolved
The port window was damaged, vessel rep needs to replace window.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 19 April 2022
Resolved
Vessel rep had an expired COD, vessel must have a valid COD onboard or have the COD be deactivated and restrict the vessel to operate only within CNMI waters.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 19 April 2022
Resolved
Vessel rep need to provide a crew that is read to conduct fire and MOB drills.
01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 2 July 2019
Resolved
Provide current medical certificate for CAPTAIN.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 2 July 2019
Resolved
Provide current FCC Station License.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 2 July 2019
Resolved
Provide the following publications; Light List, Coastal Pilot [name withheld] to Mariners. All must be up-t0-date.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 2 July 2019
Resolved
Repair and show proper operations of the public address system.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 2 July 2019
Resolved
Provide proof of annual service and tags with up-to-date service s dates. Vessel must have (04) BII and (01) BI portable CO2.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 2 July 2019
Resolved
Provide proof of annual service performed on fire boy (FGFE).
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 2 July 2019
Resolved
Repair hydraulic oil leak on steering pump.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 July 2019
Resolved
Repair inoperable deck light located at port upper deck.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 2 July 2019
Resolved
Replace damaged water seal on fire pump.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 1 October 2018
Resolved
Vessel must have valid FCC Station License. Onboard Station license expired on May 2018.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 1 October 2018
Resolved
First aid kit must have up-to-date contents. Replace expired aspirin.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 1 October 2018
Resolved
vessel must have operating navigation light. Repair inoperable starboard running light.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 1 October 2018
Resolved
Vessel must have up-to-date navigation publications. Update light list, coastal pilot and notice to mariners.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 1 October 2018
Resolved
FGFE remote activation must be label. Label port engine fire boy remote activation pull.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 1 October 2018
Resolved
Number for maximum passenger on upper deck must be post on the entrance to upper deck. Relocate sign for maximum number for passenger for upper deck so that it is visible.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 1 October 2018
Resolved
Vessel must have operational bilge high level alarms. Repair inoperable audible for bilge high level alarms.
Operations/Management › Drills/Instruction › Not Conducted
Issued 13 October 2017
Resolved
Master shall conduct drills with crew as required by 46 CFR 185.25-10 (Old T). Provide proof of quarterly drills conducted.
Navigation › Piloting/Steering › Marine Charts
Issued 13 October 2017
Resolved
Vessel must have up-to-date charts for intended voyage as required by 46 CFR 185.20-35 (Old T). Provide proof of Charts published by NOAA or NOS for Tanapag harbor.
Electrical › Lighting (service) › Lighting Fixture
Issued 13 October 2017
Resolved
Deck light must be in serviceable conditions as required by 46 CFR 183.05-50 (Old T). Repair burnt out deck light on main deck and upper deck.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 13 October 2017
Resolved
Vessel shall be equipped with suitable number of portable battery lights as required by 46 CFR 184.30-1 (Old T). Provide 2 portable flash lights.
Lifesaving › Hand Flares › Not on Board
Issued 13 October 2017
Resolved
All vessel shall carry pyrotechnic distress signal as required by 46 CFR 180.35-1 (Old T). Provide (03) red flares and (03) orange smoke with unexpired dates.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 13 October 2017
Resolved
All Fire protection equipments must be serviced annual as required by NFPA. Provide proof of annual services for Portable CO2s and pre-engineered FGFE system.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 13 October 2017
Resolved
Water light on ring life buoy must be maintained and and in good conditions as required by 46 CFR 180.30-1. Install approved missing battery on ring life buoy light.
Fire Fighting › Portable CO2 Fire Extinguisher › Mounting Bracket
Issued 13 October 2017
Resolved
Mounting bracket must be serviceable conditions as required by NFPA. Repair rusted & wasted mounting bracket for all portable CO2.
Communications › Alarms/Indicators › Bilge Alarm
Issued 13 October 2017
Resolved
Vessel must have visual and audible high water level alarm as required by 46 CFR 182.530 (New T). show proper operation of bilge alarm for starboard engine room and #3 void port side.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 7 September 2016
Resolved
All vessel must have navigation lights that are in compliance with Int'l & Inland navigation rules as required by 46 CFR 183.420. Repair inoperable STBD side (Green) light.
Engineering › Fuel Oil Service System › Valve
Issued 7 September 2016
Resolved
Fuel shutoff valve must be installed in the supply line as required by 46 CFR 182.455. Repair broken remote shutoff line.
Electrical › Lighting (service) › Lighting Fixture
Issued 7 September 2016
Resolved
Exterior light fixture must be guard or be made of higher strength material as required by 46 CFR 183.410. Repair damage upper deck light forward portside.
Lifesaving › Hand Flares › Expired
Issued 7 September 2016
Resolved
Vessel operates in lakes, bays and sounds must have (03) red flares and (03) orange smoke as required by 46 CFR 180.68. Replace expired (03) red flares.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 7 September 2016
Resolved
Fixed gas fire equipment must be service annually as required by 46 CFR 176.810 and NFPA. Provide proof of annual service conducted on FGFE system.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 7 September 2016
Resolved
Ring life buoy must have water light and lanyard with corrosion resistant clip as required by 46 CFR 180.70. Replace undersize metallic clip with proper size.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 7 September 2016
Resolved
Vessel must carry first-aid-kits as required by 46 CFR 184.704. Replace expired eye wash in the first-aid-kit.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 7 September 2016
Resolved
Vessel must have at least (02) portable battery lights as required by 46 CFR 183.430. Provide (01) missing portable battery light on board.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 7 September 2016
Resolved
Vessel must carry adequate and up-to-date charts and nautical publication as required by 46 CFR 184.420. Provide copy of the following publications on board: U.S. COAST PILOT, COAST GUARD LIGHT LIST, CHARTS, CURRENT TABLE, TIDE TABLE and NOTICE TO MARINERS.
Electrical › Electric Supply System (service) › Battery Installation
Issued 13 June 2012
Resolved
No battery trays 46 CFR 183.350. Install battery trays for main & emergency batteries.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Remote Pulls
Issued 13 June 2012
Resolved
Disconnected cable for manual actuation 46CFR181.420. Install pre-engineered FGFE system as per manufacture instruction.
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 17 September 2010
Resolved
Pre-Employment Testing - 46 CFR 16.210 / 49 CFR 40.25
Discrepancies: Result/exemptions received prior to work in a safety sensitive position, Drug testing background checks completed ( 49 CFR part 40.25 )
Operations/Management › Drug and Alcohol Testing › Testing, Serious Marine Incident
Issued 17 September 2010
Resolved
Serious Marine Incident Testing - 46 CFR 16.240 or 46 CFR 4.06
Discrepancies: Arrangements made for post-casualty testing
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 17 September 2010
Resolved
EAP Requirements - 46 CFR 16.401
Discrepancies: Following Items Displayed: EAP, Policy/Statement, Hotline Number, Crewmembers properly trained before assuming safety sensitive position, Supervisor received 1 hour EAP training, Employer has Substance Abuse Professional (SAP) name and contact information
Pollution Prevention/Response › Prevention Equipment › Bilge Monitor
Issued 25 March 2010
Resolved
Found inoperable bilg high water level alarm starboard mid void. Reapir alrm.
Communications › Public Address System › Announcing Station
Issued 25 March 2010
Resolved
Found PA system inoperable. Repair PA system.
Documentation › Certificates/Documents › Proof of Consortium Enrollment (DAPI)
Issued 25 March 2010
Resolved
Found crew not on company drug program. Provide a proof crew drug program enrollment.
Documentation › Certificates/Documents › FCC Vessel Bridge-to-Bridge Radiotelephony Cert.
Issued 25 March 2010
Resolved
Found missing FCC safety certificate. Provide a proof of FCC Safety Cert.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 25 March 2010
Resolved
Found expired eye wash solution in first aid kit. Repalce expired eye wash solution.
Navigation › Piloting/Steering › Marine Charts
Issued 25 March 2010
Resolved
Found 2004 area chart. Provide a current area chart.
Documentation › Certificates/Documents › FCC SSL
Issued 25 March 2010
Resolved
Found deferent call sign on Station license and COI.
Construction/Loadline › Hull › Hull Plating
Issued 19 March 2010
Resolved
Found hull damage about 5 inch long on starboard forefoot 2 feet from water line. Repair hull damage IAW 8-87.
Construction/Loadline › Hull › Bottom Plating
Issued 19 March 2010
Resolved
Found FRP blisters through out both hull below water line. Repair all indicated FRP blisters on both hulls.
Construction/Loadline › Penetrations › Valve Flange
Issued 19 March 2010
Resolved
Found damaged through hull valve on port main engine salt water suction valve. Replace warped 1/4" suction valve.
Engineering › Shafting/Propeller Arrangements › Strut Bearing
Issued 19 March 2010
Resolved
Found port shaft strut cutlass bearing with more that 50% wear. Replace cutlass bearing.
Engineering › Fuel Oil Service System › Hose
Issued 19 March 2010
Resolved
Found fuel line hoses on both main engines spliced and connected with brass tube and hose clamps. Replace fuel line with CG approved fuel hose.
Construction/Loadline › Hull › Weld
Issued 19 March 2010
Resolved
Found weld cracks on stern swimming platform hinges. Repair all weld cracks.
Electrical › Electrical Distribution System (service) › Wiring
Issued 19 March 2010
Resolved
Found electrical wiring in both port and starboard engine room and bilge high level alarm in both hulls with wire nut connections. Replace all wire connections with water tight heat srink connector.
Construction/Loadline › Structures › Manhole
Issued 19 March 2010
Resolved
Found dry rot wood on port forward hatch framing. Repalce rot wood.
Documentation › Certificates/Documents › FCC SSL
Issued 14 July 2009
Resolved
Provide a proof of current FCC safety certificate.
Operations/Management › Drills/Instruction › Fire
Issued 14 July 2009
Resolved
Provide a training log book for fire and man overboard drills.
Fire Fighting › Fire Bucket › Stenciling
Issued 14 July 2009
Resolved
Stencile in contrast color with buckets, the word " FIRE BUCKET" .
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 14 July 2009
Resolved
Repair railing - port side midship.
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 14 July 2009
Resolved
Install missing valve handle on sewage salt water supply valve.
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 14 July 2009
Resolved
Provide document ( letter) for designate senior deck hand I.A.W. NVIC 1-91.
Construction/Loadline › Structures › Superstructure
Issued 14 July 2009
Resolved
Replace cracked wind shield forward port side.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 20 June 2008
Resolved
Provide proof that the fixed fire extinguishing system for both engine rooms has had annual servicing.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 20 June 2008
Resolved
Install plastic seal for starboard aft fire extinguisher pin.
Personnel › Training › First Aid/CPR
Issued 20 June 2008
Resolved
Provide proof that at least half of the crew has current first-aid and CPR training.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 20 June 2008
Resolved
Place on board current copy of Coast Guard light list for area vessel operates in.
Navigation › Piloting/Steering › Marine Charts
Issued 20 June 2008
Resolved
Place on board current corrected chart for area vessel operates in.
Navigation › Piloting/Steering › US Coast Pilot
Issued 20 June 2008
Resolved
Place on board current copy of US Coast pilot for area vessel operates in.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 20 June 2008
Resolved
Place on board current copy of tide tables and tidal current tables for area vessel operates in.
Documentation › Certificates/Documents › FCC SSL
Issued 20 June 2008
Resolved
Place on board current FCC station license.
Construction/Loadline › Hull › Hull Plating
Issued 2 June 2008
Resolved
Remove temporary repairs to bow section and make permanent repairs in accordance with NVIC 8-87.
Construction/Loadline › Hull › Bottom Plating
Issued 2 June 2008
Resolved
Port hull forward crop out to good laminate and make permanenet repairs.
Construction/Loadline › Hull › Side Shell
Issued 2 June 2008
Resolved
Grind or sand back to good laminate several identified spots on port side and make permamnent repairs.
Construction/Loadline › Hull › Hull Plating
Issued 2 June 2008
Resolved
Provide access to compartment between second and third bulkhead for USCG inspection.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 2 June 2008
Resolved
Remove both propellers and make available for USCG inspection. Replace both port and starboard shaft bearings and packing.
Engineering › Steering Gear System › Rudder
Issued 2 June 2008
Resolved
Replace both port and starboard rudder bearings.
Engineering › Sea-water System (primary cooling) › Valve
Issued 2 June 2008
Resolved
Remove all through hull fittings, including all sea suction valves, bilge pump overboard discharge check valves.
Construction/Loadline › Hull › Side Shell
Issued 2 June 2008
Resolved
Grind or sand back to good laminate several identified spots on starborad side and make permamnent repairs.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 2 June 2008
Resolved
Remove temporary repairs made to second transverse bulkhead and make permanent repairs.
Accommodation/Occupational Safety › Washroom/Toilet › Number Per Persons
Issued 2 June 2008
Resolved
Install second toilet and mark one for male and one for female. Vessel takes voyages longer than 30 minutes several times a week.
Construction/Loadline › Hull › Bottom Plating
Issued 2 June 2008
Resolved
Port hull ten feet aft of midship make permenent repairs to two foot by two foot section.
Construction/Loadline › Hull › Strut/Cross Tie
Issued 2 June 2008
Resolved
Grind or sand back to good laminate inboard side of port shaft strut and make permamnent repairs.
Accommodation/Occupational Safety › Washroom/Toilet › Washbasin
Issued 2 June 2008
Resolved
Install washbasin in second toilet as per 46CFR177.30-5.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 2 June 2008
Resolved
Replace all four B-II fire extinguishers due to excessive corrosion.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 2 June 2008
Resolved
Provide service to expired B-I fire extinguisher.
Engineering › Bilge Water Management System › Pump
Issued 2 June 2008
Resolved
Secure/mount electric bilge pumps in port & stbd engine compartments to prevent movement.
Fire Fighting › Fixed Halon Fire Extinguishing System › Tanks
Issued 12 July 2007
Resolved
Found fixed fire extinguishing system without annual servicing. Prove system has received servicing.
Operations/Management › Drills/Instruction › Not Conducted
Issued 12 July 2007
Resolved
Found crew not conducting monthly drills. Prove all required drills are conducted on a monthly basis.
Navigation › Piloting/Steering › Marine Charts
Issued 12 July 2007
Resolved
Found navigation charts not corrected. Prove charts are current and corrected.
Electrical › Lighting (service) › Lighting Fixture
Issued 12 July 2007
Resolved
Found anchor light lens cracked. Replace cracked lens.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 12 July 2007
Resolved
Found starboard deck rail cracked. Make permenant repairs to rail.
Construction/Loadline › Hull › Bottom Plating
Issued 12 July 2007
Resolved
Found water entering the vessel through the seal of the second from forward glass bottom.
Vessel captain to log daily the amount of water pumped from the compartment until permanent repairs have been made.
Fire Fighting › Fire Hydrants › Condition
Issued 12 July 2007
Resolved
Found fire stations missing spanner wrenches. Prove a spanner wrench is available on board the vessel for both stations.
Engineering › Bilge Water Management System › Hose
Issued 12 July 2007
Resolved
Found bilge overboard hoses on #2 and 3 port not of approved material. Prove all bilge hoses are of approved material.
Electrical › Lighting (service) › Lighting Fixture
Issued 12 July 2007
Resolved
Found 2 lighting fixtures missing cages. Prove all lighting fixures have cages.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 20 July 2006
Resolved
Found vessel's original certificate of documentation not onboard. Prove vessel has valid COD onboard.
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 27 June 2006
Resolved
Found vessel missing up to date navigation publications. Prove vessel has up to date navigation publications.
Engineering › Gasoline Engine (propulsion) › Pump, Cooling Water (4 cycle)
Issued 27 June 2006
Resolved
Found vessel port engine water temperature guage on bridge not functioning. Prove temperature guage works properly.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 27 June 2006
Resolved
Found vessel bilge pump operation visual indicator not funtioning. Prove visual bilge pump operation indicator functions.
Communications › Alarms/Indicators › Bilge Alarm
Issued 27 June 2006
Resolved
Found vessel bilge high water level alarms not working. Prove proper operation of all bilge alarms.
Operations/Management › Drills/Instruction › Fire
Issued 27 June 2006
Resolved
Found fire drill performed inadeqately. Prove vessel crew can properly perform fire drill.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 11 October 2005
Resolved
Found the company was not operating with a drug program. Removed COI and directed the owner/operator to enroll in an approved drug program prior to operating with passengers.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 11 October 2005
Resolved
Found port engines exhaust pipe leaking. Repair or replace leaking exhaust pipe.
Operations/Management › Drills/Instruction › Fire
Issued 11 October 2005
Resolved
Found crew unable to properly respond to fire situations. Prove the crew can fight fires onboard the vessel.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 11 October 2005
Resolved
Found crew unable to properly respond to man overboard. Prove the crew can safely recover man overboard.
Electrical › Electric Supply System (service) › Cable
Issued 11 October 2005
Resolved
Found dead-end wires throughout vessel. Remove dead-end wire to junction box.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 11 October 2005
Resolved
Found port and starboard engines belts and pulley exposed to crew during emergency situations. Install safety guards around belts and pulley.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 11 October 2005
Resolved
Found portable fire extinguishers not service annually. Service fire extinguishers.
Operations/Management › Pollution › Control of Garbage
Issued 11 October 2005
Resolved
Found the vessel did not have a waste management plan in place. Post and follow a approved waste management plan.
Personnel › Training › First Aid/CPR
Issued 11 October 2005
Resolved
Found the vessel did not have 50% of crew trained in First Aid/CPR. Train 50% of crew in First Aid/CPR.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 11 October 2005
Resolved
Found the vessel did not have a current training log, a lifesaving equipment maintenance records or bridge log. Maintain all applicable Ops Readiness/maintenance and inspection logs and records.
Navigation › Piloting/Steering › Magnetic Compass
Issued 11 October 2005
Resolved
Found the magnetic compass back light on operating properly. Repair back light prior to operating at night.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 11 October 2005
Resolved
Found the vessel was not maintaining proper passenger counts. Maintain passenger counts on all trips.
Communications › Internal Communications System › Portable Radios
Issued 11 October 2005
Resolved
Found master unable communicate to upper deck deckhand. Establish communication to upper deck prior to operating with passengers.
Stability › Freeing Ports › General
Issued 11 October 2005
Resolved
Found freeing port block with carpet. Open freeing ports.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 11 October 2005
Resolved
Found the vessel did not have a valid COD. Prove the vessel is documented by USCG for service.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 11 October 2005
Resolved
Found the vessel was waiting on EAP training program from consortium. Conduct EAP training when materials are available.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 8 April 2004
Resolved
Personnel › Certificates/Documents/Licenses › Certificate, First Aid Course Completion
Issued 8 April 2004
Resolved
Documentation › Certificates/Documents › FCC SSL
Issued 8 April 2004
Resolved
RADIO STATION LICENSE
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 8 April 2004
Resolved
Lifesaving › Embarkation Appliances/Stations › Steps
Issued 8 April 2004
Resolved
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 8 April 2004
Resolved
AUTOMATIC MODULE AND ALARM INOPERATIVE. SYSTEM OPERABLE IN MANUAL MODE.
Communications › Audible Communications › Horn/Whistle
Issued 8 April 2004
Resolved
Communications › Audible Communications › SPD (Other)
Issued 8 April 2004
Resolved
PUBLIC ADDRESS SYSTEM INOPERATIVE
Deck/Cargo › Mooring/Anchoring › Anchor Rope
Issued 8 April 2004
Resolved
INCREASE LENGTH OF LINE TO APPROX 5 - 7 TIMES DEPTH OF WATER VESSEL EXPECTS TO OPERATE IN.
Communications › Radio Communications › VHF Radiotelephone
Issued 8 April 2004
Resolved
VHF Radiotelephone - Improper Installation
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 29 October 2003
Resolved
PROVE PROPER OPERATION OF FIXED FIRE FIGHTING SYSTEM LEGACY COMPONENT DESC: Operating Controls
Engineering › Bilge Water Management System › Not Operational
Issued 29 October 2003
Resolved
PROVE PROPER OPERATION OF BILGE SYSTEM LEGACY COMPONENT DESC: Operation, Alarms & Indicators
Operations/Management › Passenger Operations
Issued 31 January 2003
Resolved
Senior deck hand tested 31 Jan 2003 and oberved to not have the knowledge/skills required under NVIC 1-91.
Deck/Cargo › Mooring/Anchoring
Issued 31 January 2003
Resolved
Anchor line insufficient length given vessel's route and reasonable cable/depth ratios for shallow water anchoring. Owner/operator to conduct assessment and provide sufficiently long anchor line.
Accommodation/Occupational Safety › Occupational Safety
Issued 17 January 2003
Resolved
Vessel w/o two operable emergency flashlights per 46 CFR Subchapter T.
Operations/Management › FireFighting
Issued 28 December 2002
Resolved
Vessel operator and crew unable to start fire pumps after ten minutes of effort due to their lack of understanding of the vessel's electrical system. All operators of said vessel and all crew members shall be provided with detailed training on how to operate said pumps in a timely manner.
Operations/Management › Passenger Operations
Issued 28 December 2002
Resolved
Vessel dive master failing to adhere to company established record keeping program to allow for managerial and third party verification of compliance with 46 CFR 197 requirements.
Engineering › Bilge Water Management System
Issued 28 December 2002
Resolved
Vessel unable to demonstrate operation of bilge alarm system. LEGACY COMPONENT DESC: Alarms
Engineering
Issued 28 December 2002
Resolved
Engine control panel boost meters, not required by federal regulation, not operable. Boost meters shall be restored to proper functioning or removed from vessel.
Accommodation/Occupational Safety › Occupational Safety
Issued 4 October 2002
Resolved
Vessel unable to demonstrate compliance with 46 CFR 197 Subpart A. Prior to issuance of a COI the vessel shall demonstrate satisfactory compliance so as to assure the safety of passengers engaged in diving activities.
Construction/Loadline › Structures
Issued 4 October 2002
Resolved
Side shell upper deck support located on the stbd side in way of ring buoy fractured in non-adherence with 46CFR177.300 /.310. Satisfactory repair utilizing appropriate marine grade materials required to be conducted to the satisfaction of the attending USCG Marine Inspector prior to COI issuance LEGACY COMPONENT DESC: Side shell upper deck support
Construction/Loadline › Structures
Issued 4 October 2002
Resolved
Deck rail sections, previously installed, fractured and missing in non-adherence with 46 CFR 177.900. Deficiency required to be corrected prior to issuance of COI. LEGACY COMPONENT DESC: Railings
Documentation › Certificates/Documents
Issued 4 October 2002
Resolved
Vessel's Certificate of Documentation not renewed in non-adherence with 46 CFR 67.7/67.9. Deficiency outstanding since 2001. LEGACY COMPONENT DESC: Certificate of Documentation (CG-1270)
Communications › Audible Communications
Issued 4 October 2002
Resolved
Passenger safety orientation incomplete in non-adherence with 46 CFR 185.506. Deficiency required to be corrected prior to the issuance of a COI.
Fire Fighting
Issued 4 October 2002
Resolved
Vessel missing one B-I and one B-II portable fire extinguisher in non-adherence with 46 CFR 181.500. Deficiency required to be corrected prior to COI issuance.
Fire Fighting › Fire Pumps
Issued 4 October 2002
Resolved
Port PTO fire pump inoperable in non-adherence with 46 CFR 181.300.
Fire Fighting
Issued 4 October 2002
Resolved
Stb engine fixed gas fire extinguishing system audible alarm not functioning in non-adherence with 46 CFR 181.41/.420.
Accommodation/Occupational Safety › Medical/First Aid
Issued 4 October 2002
Resolved
First Aid Kit incomplete in non-adherence with 46 CFR 184.710
Navigation › Collision/Grounding Avoidance
Issued 4 October 2002
Resolved
Masthead light inoperable in non-adherence with International Navigation Rules. Deficiency required to be corrected prior to issuance of COI.
Navigation › Piloting/Steering
Issued 4 October 2002
Resolved
Compass without light in non-adherence with 46 CFR 184.402. LEGACY COMPONENT DESC: Magnetic Compass
Lifesaving › Embarkation Appliances/Stations
Issued 4 October 2002
Resolved
Rescue ladder support fractured in non-adherence with 46 CFR 180. Deficiency required to be corrected prior to issuance of COI.
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 4 October 2002
Resolved
Stbd engine fixed gas fire extinguishing system wire pull cable deteriorated in non-adherence with 46 CFR 181.410/.420.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 4 October 2002
Resolved
Stbd motor salt water discharge hose deteriorated in non-adherence with 46 CFR 182. Deficiency required to be corrected using appropriate grade hose prior to issuance of COI.
Engineering › Fuel Oil Service System
Issued 4 October 2002
Resolved
Fuel tank vents deteriorated in non-adherence with 46 CFR 182.
Operations/Management
Issued 4 October 2002
Resolved
Miscellaneous markings, eg upper deck passenger carrying capacity, in non-adherence with 46 CFR 185.
Communications
Issued 4 October 2002
Resolved
Public address system not operable in non-adherence with 46 CFR 184.610. Deficiency requires correction prior to issuance of COI.
Deck/Cargo
Issued 4 October 2002
Resolved
Anchor mooring line deteriorated in non-adherence with 46 CFR 184.300. Deficiency required to be corrected prior to COI issuance.
Construction/Loadline › Structures
Issued 4 October 2002
Resolved
Hatch/scuttle securing mechanisms deteriorated in non-adherence with 46 CFR 179.360(b).
Engineering
Issued 18 October 2001
Resolved
Vessel shall install proper fuel tank vent flame screens pursuant to regulatory requirements.
Lifesaving
Issued 18 October 2001
Resolved
Vessel shall install proper engineroom ventilation closures pursuant to regulatory requirements.
Construction/Loadline
Issued 18 October 2001
Resolved
Vessel shall put in place proper hull markings pursuant to regulatory requirements.
Lifesaving
Issued 18 October 2001
Resolved
Vessel shall renew upper deck passenger load limitation stenciling pursuantto regulatory requirements.
Lifesaving
Issued 18 October 2001
Resolved
Vessel shall reinstall upper deck public address system pursuant to regulatory requirements.
Electrical
Issued 18 October 2001
Resolved
Vessel shall properly insulate electrical wiring connection points (wire- to-wire) pursuant to regulatory requirements.
Engineering
Issued 18 October 2001
Resolved
Vessel shall replace engineroom engine fluid overflows (one gallon capacitybleach jugs) with manufacturer approved units pursuant to regulatory requirements. If mfg units are not available, vessel to install metal overflow recepticles well away from moving parts and other appurtances.
Documentation
Issued 18 October 2001
Resolved
Vsl not able to provide satisfactory evidence of compliance w/46 CFR 16 drug program requirements due to lack of records aboard the vsl.
Lifesaving
Issued 18 October 2001
Resolved
Vsl unable to provide satisfactory evidence of compliance w/46 CFR 197 re: commercial dive operations due to lack of documentary records and availability of equipment which was removed prior to the reinspection.
Navigation
Issued 18 October 2001
Resolved
Vessel did not possess proper, current navigation charts and publications for the area transitted pursuant to regulatory requirements.
Lifesaving
Issued 18 October 2001
Resolved
Vessel failed to demonstrate satisfactory passenger safety orientation pursuant to regulatory requirements.
Fire Fighting
Issued 18 October 2001
Resolved
Vessel shall have fixed fire extinguishing system inspected and serviced pursuant to regulatory requirements.
Lifesaving
Issued 18 October 2001
Resolved
Vessel shall obtain second emergency flashlight pursuant to regulatory requirements.
Lifesaving
Issued 27 September 2000
Resolved
Provide and post lifejacket donning placards for all styles of lifejackets carried on board.
Construction/Loadline
Issued 27 September 2000
Resolved
Prove the operation of the steering compartment bilge pump.
Engineering
Issued 27 September 2000
Resolved
Adjust and prove the operation of the port and stbd fuel tank shut-off valves.
Construction/Loadline
Issued 27 September 2000
Resolved
Restore to original the stringer to hull bonding angle in the steering compartment, centerline.
Construction/Loadline
Issued 27 September 2000
Resolved
Prove the operation of the high-level bilge alarms for the port and stbd shaft compartment, and the steering compartment.
Navigation
Issued 27 September 2000
Resolved
Properly ground the steering system to the hull.
Lifesaving
Issued 27 September 2000
Resolved
Log quarterly man-overboard and fire drills.
Lifesaving
Issued 28 March 2000
Resolved
Properly secure air compressor mounted on upper deck to prevent movement.
Fire Fighting
Issued 17 March 2000
Resolved
Install the proper fire extinguishing systems with the approved type manualdischarge systems (including cylinder control heads) in lieu of the presenttie wraps; port and stbd engine rooms.
Fire Fighting
Issued 17 March 2000
Resolved
Permanently seal openings in the aft bulkheads of the port and stbd engine rooms.
Construction/Loadline
Issued 17 March 2000
Resolved
Permanently repair delaminated side shell stiffeners in the port and stbd engine rooms.
Construction/Loadline
Issued 17 March 2000
Resolved
Permanently repair fractured-delaminated side shell stiffener located in the stbd aft compartment.
Construction/Loadline
Issued 3 November 1999
Resolved
Renew the watertight inspection covers on the main deck directly forward ofthe engine hatch covers on the port and starboard sides.
Construction/Loadline
Issued 3 November 1999
Resolved
Install a distinct and visible indicator for the lazarette high level bilgealarm.
Lifesaving
Issued 16 September 1999
Resolved
Locate a ring buoy on the upper deck.
Documentation
Issued 16 September 1999
Resolved
Renew Oil pollution placards in each engine room.
Lifesaving
Issued 16 September 1999
Resolved
Develop written passenger safety brief in accordance with 46 CFR 185.506. Train crew and implement. Safety brief shall be given to all passengers prior to each voyage.
Engineering
Issued 16 September 1999
Resolved
Properly tighten securing clamps for shift and throttle cables on control heads at the helm.
Navigation
Issued 16 September 1999
Resolved
Provide an 8 inch bell with bracket for the vessel.
Fire Fighting
Issued 16 September 1999
Resolved
Conduct and provide documentation of annual servicing for all fire extinguishers.
Lifesaving
Issued 16 September 1999
Resolved
Provide 2 additional adult PFDs for the vessel.
Fire Fighting
Issued 16 September 1999
Resolved
Install automatic engine and ventilation blower shut-downs upon activation of the FE-241 system in the port and stbd engine rooms.
Lifesaving
Issued 16 September 1999
Resolved
Provide retro-reflective tape for 6 adult and 4 child PFDs.
Lifesaving
Issued 16 September 1999
Resolved
Provide two 24 inch, orange ring buoys for the vessel with the vessel name stenciled and retro-reflective tape. Additionally attach 60 feet of polypropylene line and provide a 3 to 6 feet lanyard with clip for the waterlight.
Navigation
Issued 16 September 1999
Resolved
Provide current copy of navigation rules for the vessel.
Lifesaving
Issued 16 September 1999
Resolved
Prove proper opening/closing of doors to each head.
Lifesaving
Issued 16 September 1999
Resolved
Conduct emergency drills in the presence of a USCG marine inspector by 23SEP99.
Construction/Loadline
Issued 16 September 1999
Resolved
Repair delaminated bonding angles on interior of stbd bulwark, stem to stern and transom.
Engineering
Issued 16 September 1999
Resolved
Relocate main engine crankcase breathers so that they do not vent and discharge oil directly overboard. New crankcase breaters shall be located within engine room. The existing hull connections shall be removed and properly sealed.
Construction/Loadline
Issued 16 September 1999
Resolved
Renew in kind wasted/rotten longitudinal beam in overhead of aft head.
Construction/Loadline
Issued 16 September 1999
Resolved
Make watertight all PVC pipes which penetrate the subdivision and collisionbulkheads and decks.
Construction/Loadline
Issued 16 September 1999
Resolved
Make watertight the upper edge of the collision bulkhead.
Construction/Loadline
Issued 16 September 1999
Resolved
Double clamp all discharge hoses for the electric bilge pumps and hatch coaming drains.
Engineering
Issued 16 September 1999
Resolved
Prove the operation of the port engine lube oil gauge at the helm.
Construction/Loadline
Issued 16 September 1999
Resolved
Ensure all freeing ports remain free of obstructions.
Unknown
Issued 16 September 1999
Resolved
Master shall designate a senior deckhand in writing. A copy of this designation shall be kept aboard and the senior deckhand shall be trained in accordance with NVIC 1-91.
Engineering
Issued 16 September 1999
Resolved
Install and prove the operation of both main engine shut-downs from the helm.
Engineering
Issued 16 September 1999
Resolved
Extend the fuel fill pipes to the weather deck and electrically bond.
Construction/Loadline
Issued 16 September 1999
Resolved
Prove the operation of the following high level bilge alarms: port and stbd shaft alleys; port and stbd engine rooms; and forward center compartment.
Fire Fighting
Issued 16 September 1999
Resolved
Develop, post and train crew in operation of fixed fire extinguishing systems and shut-downs of both main engine and ventilation blowers.
Engineering
Issued 16 September 1999
Resolved
In lieu of plastic bowls, install metallic bowls for each main engine fuel filters.
Engineering
Issued 16 September 1999
Resolved
Double nut or cotter pin the throttle linkages on both main engines.
Construction/Loadline
Issued 16 September 1999
Resolved
Properly label all bilge pump control switches at the helm.
Construction/Loadline
Issued 16 September 1999
Resolved
Install high level bilge alarms and electric bilge pump for the lazarette.
Construction/Loadline
Issued 16 September 1999
Resolved
Seal all openings and make aft bulkhead of each engine room vapor tight.
Fire Fighting
Issued 16 September 1999
Resolved
Install manual activation cables for each FE-241 system.
Construction/Loadline
Issued 16 September 1999
Resolved
Properly position the swing check valves in a horizontal-perpendicular position for all bilge pump discharge hoses.
Construction/Loadline
Issued 16 September 1999
Resolved
Properly mount bilge suction hose and strainers in port and stbd engine rooms.
Construction/Loadline
Issued 16 September 1999
Resolved
Install metallic shut-off valves for the bilge pump overboard connections on the port and stbd shaft alleys.
Engineering
Issued 16 September 1999
Resolved
Properly insulate both main engine exhaust piping up to the point of water injection.
Navigation
Issued 16 September 1999
Resolved
Renew wasted/worn bushing and hardware at steering tiller-cross bar linkageconnections on port and stbd sides. New hardware shall be double nutted, cotter pinned, or nylocks.
Construction/Loadline
Issued 16 September 1999
Resolved
Install handle and prove operation of salt water supply valve for toilet.
Accommodation/Occupational Safety
Issued 16 September 1999
Resolved
Prove the operation of the seized overboard valve for the sewage holding tank.
Construction/Loadline
Issued 16 September 1999
Resolved
Install securing and captive devices for all main deck hatch covers.
Engineering
Issued 16 September 1999
Resolved
Repair exhaust leak on port main engine turbocharger.
Engineering
Issued 16 September 1999
Resolved
Install emergency remote fuel shut-off valve at each fuel tank connection which are operable from outside the fuel tank space on the port and stbd fuel tanks.
Electrical
Issued 16 September 1999
Resolved
Block in place to prevent shifting all starting batteries in the port and stbd engine rooms.
Engineering
Issued 16 September 1999
Resolved
Install SAE marine grade hoses for both main engine salt water cooling systems.
Lifesaving
Issued 28 September 1998
Resolved
Provide wire splint and tourniquet for first aid kit.
Navigation
Issued 28 September 1998
Resolved
Replace bulb for compass. Until bulb is replaced vsl is restricted to daytime ops only.
Documentation
Issued 28 September 1998
Resolved
Provide and post valid FCC Safety Radio Certificate.
Fire Fighting
Issued 28 September 1998
Resolved
Replace/service 2 BII portable fire extinuguishers.
Engineering
Issued 28 September 1998
Resolved
Place lagging around exhaust system where it penetrates E/R bulkhead.
Fire Fighting
Issued 11 October 1995
Resolved
PROVIDE PROOF OF SERVICING OF PORTABLE FIRE EQUIPMENT.
Construction/Loadline
Issued 11 October 1995
Resolved
DRYDOCK VESSEL FOR INSPECTION OF FORWARD AREA OF PORT AND STARBOARD BOWS TOEXAM DAMAGED AREAS.
Engineering
Issued 11 October 1995
Resolved
INSTAL MACHINERY GUARDS TO PORT AND STARBOARD MDE.
Electrical
Issued 11 October 1995
Resolved
INSTAL BATTERY COVERS.
Navigation
Issued 11 October 1995
Resolved
REWELD STEERING SUPPORT STBD SIDE DURING NEXT SCHEDULED DRYDOCK.
Unknown
Issued 13 October 1993
Resolved
Makke vessel ready for credit hull exam in drydock staus with all compartments opened and all sea valves removed and opened
Lifesaving
Issued 1 November 1988
Resolved
STENCIL AREA WHERE CHILDREN'S LIFE PRESERVERS ARE STOWED WITH NUMBER AND TYPE.
Navigation
Issued 1 November 1988
Resolved
CLEAN LENSES ON ALL NAVIGATION LIGHTS.
Navigation
Issued 1 November 1988
Resolved
PROVIDE MARINE VHF FM RADIO. VESSEL IS NOT TO BE OPERATED MORE THAN 1000 FT. FROM LAND UNTIL THIS ITEM IS CORRECTED.
Engineering
Issued 1 November 1988
Resolved
MAKE PERMANENT REPAIRS TO PORT AND STARBOARD ENGINE SPACE VENTILATION FANS.
Engineering
Issued 1 November 1988
Resolved
INSTALL AND PROPERLY LABEL REMOTE FUEL SHUT-OFF VALVES FOR PORT AND STARBOARD ENGINES.
Lifesaving
Issued 1 November 1988
Resolved
STENCIL VESSEL'S NAME ON ALL LIFEJACKETS.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.