Records from 1985 to 1990. Most recent: inspection, 4 June 1990.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 11
4 June 1990
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 929983
27 April 1989
COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1194636
31 May 1988
Hull Examination · Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1037222
3 December 1987
Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1316970
21 July 1987
Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1339429
8 May 1987
COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1333821
12 November 1986
Deficiency Check · Examination of Repairs
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1020625
30 July 1986
Deficiency Check · Credit Drydock
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1277913
11 June 1986
Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1301174
9 May 1985
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1289172
13 March 1985
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1298490
Fire Fighting
Issued 21 July 1987
Resolved
HYDROSTATICALLY TEST THE FIXED CO2 BOTTLES NUMBERED 5160881 AND 5161848.
Condition: Unknown
Due 21 July 1987
Resolved 21 July 1987
Lifesaving
Issued 8 May 1987
Resolved
PROVIDE TWELVE COAST GUARD APPROVED RED HAND HELD DISTRESS SIGNALS FOR THE NUMBER ONE MOTOR LIFEBOAT.
Condition: Unknown
Due 8 May 1987
Resolved 8 May 1987
Fire Fighting
Issued 8 May 1987
Resolved
INSPECT EACH FIXED FIRE EXTINGUISHING SYSTEM IN ACCORDANCE WITH 46 CFR 109.223.
Condition: Unknown
Due 8 May 1987
Resolved 8 May 1987
Fire Fighting
Issued 8 May 1987
Resolved
SERVICE AND HYDROSTATICALLY TEST THE OXYGEN BOTTLES FOR THE SELF CONTAINED BREATHING APPARATUS.
Condition: Unknown
Due 8 May 1987
Resolved 8 May 1987
Fire Fighting
Issued 8 May 1987
Resolved
PROVIDE AN UL, FM OR CSA LABELED OXYGEN/COMBUSTIBLE GAS MONITOR FOR EACH OFTHE REQUIRED FIREMEN'S OUTFITS.
Condition: Unknown
Due 8 May 1987
Resolved 8 May 1987
Electrical
Issued 8 May 1987
Resolved
RENEW THE ELECTRICAL SOLENOID FOR THE EMERGENCY GENERATOR. CONDUCT A TEST OF THE GENERATOR PROME MOVER OVERSPEED TRIP, LOW LUBE OIL TRIP, ALARM, AND THE JACKET WATER ALARM IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 8 May 1987
Resolved 8 May 1987
Engineering
Issued 8 May 1987
Resolved
MAKE THE FIVE DRY BULK PRESSURE VESSELS AVAILABLE FOR INTERNAL INSPECTION BY A COAST GUARD MARINE INSPECTOR.
Condition: Unknown
Due 8 May 1987
Resolved 8 May 1987
Lifesaving
Issued 8 May 1987
Resolved
PROVIDE ELEVEN USCG APPROVED LIFE PRESERVERS TO BRING THE TOTAL NUMBER OF PFD(S) ON BOARD IN COMPLIANCE WITH THE NUMBER REQUIRED BY THE CERTIFICATE OF INSPECTION. UNTIL THE PFD(S) ARE ON BOARD THE MAXIMUM PERSONS PERMITTEDIS 89.
Condition: Unknown
Due 8 May 1987
Resolved 8 May 1987
Fire Fighting
Issued 8 May 1987
Resolved
HYDROSTATICALLY TEST THE HELICOPTER PAD SEMI PORTABLE DRY CHEMICAL FIRE EXTINGUISHERS.
Condition: Unknown
Due 8 May 1987
Resolved 8 May 1987
Unknown
Issued 30 July 1986
Resolved
MAKE PERMANENT REPAIRS TO THE #3 STARBOARD DRILL WATER TANK. REPAIR PROPOSAL IS TO BE SUBMITTED TO MARINE SAFETY OFFICE HONOLULU PRIOR TO COMMENCEMENT.
Condition: Unknown
Due 30 July 1986
Resolved 30 July 1986
Unknown
Issued 30 July 1986
Resolved
SERVICE THE 4 INFLATABLE LIFERAFTS AT AN APPROVED SERVICING FACILITY.
Condition: Unknown
Due 30 July 1986
Resolved 30 July 1986
Unknown
Issued 11 June 1986
Resolved
ALL CO2 PORTABLE FIRE EXTINGUISHERS ARE TO BE HYDROSTATICALLY TESTED.
Condition: Unknown
Due 11 June 1986
Resolved 11 June 1986
Unknown
Issued 11 June 1986
Resolved
ALL FIXED CO2 SYSTEMS ARE TO BE TESTED: PULL CABLES, ALARMS, VENT SHUTDOWNS AND TIME DELAYS SHALL BE TESTED.
Condition: Unknown
Due 11 June 1986
Resolved 11 June 1986
Unknown
Issued 11 June 1986
Resolved
ALL TESTING OF FIREFIGHTING EQUIPMENT SHALL BE RECORDED AS PER 46 CFR 109.435.
Condition: Unknown
Due 11 June 1986
Resolved 11 June 1986
Unknown
Issued 11 June 1986
Resolved
SERVICE THE 4 INFLATABLE LIFERAFTS AT AN APPROVED SERVICING FACILITIY.
Condition: Unknown
Due 11 June 1986
Resolved 11 June 1986
Unknown
Issued 11 June 1986
Resolved
MAKE PERMANENT REPAIRS TO #3 STARBOARD DRILL WATER TANK. REPAIR PROPOSAL AND PROCEDURE IS TO BE SUBMITTED TO MSO HONOLULU PRIOR TO 31JUL86.
Condition: Unknown
Due 11 June 1986
Resolved 11 June 1986
Unknown
Issued 9 May 1985
Resolved
REPLACE THE THROW-OVER INFLATABLE LIFERAFTS WITH DAVIT-LAUNCHED LIFERAFTS OF THE SAME TOTAL CAPACITY. SUBMIT PLANS TO MMT FOR APPROVAL. ADVISE THIS OFFICE OF YOUR SCHEDULE FOR THIS INSTALLATION.
Condition: Unknown
Due 9 May 1985
Resolved 9 May 1985