F M BROWN
Passenger (Inspected) · Passenger Ship class · Built 1970s · USCG Heartland District (CGD-H) · Other hulls named F M BROWN
F M BROWN is a 1973 passenger vessel (inspected). The Coast Guard has recorded 40 inspections since 2000, most recently in March 2026, along with 86 deficiencies and 1 casualty investigation in 2008.
Records from 2000 to 2026. Most recent: inspection, 17 March 2026.
- Built
- 1973
- Last inspected
- 17 March 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 86 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 1 investigation · 2008
Identity
552760
WDJ8261
228925
Flag
UNITED STATES
368014710
Maury page id
psix-228925
Inspections, by type
…with no type recorded5
Years with a record
24 calendar years (2000–2026)
The 40 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)61.6 ft × 17.0 ft × 5.8 ft
Registered tonnagegross 66 / net 45
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBREAUX'S BAY CRAFT · LOREAUVILLE LA, UNITED STATES · built 1973
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portHOUSTON, TX
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 5 February 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it66 - Regulatory (Subpart C or D), Gross Ton
45 - Regulatory (Subpart C or D), Net Ton
45 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDJ8261MMSI 368014710 · active · compulsorily equipped · granted 1 December 2017, expires 1 December 2027 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 40
17 March 2026
Deficiency Check · Vessel Attendance · Annual Inspection · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8323727
20 February 2026
Vessel Attendance · Internal Structural Exam · Administrative Inspection · Examination of Repairs · Drydock Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8307177
14 July 2025
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8185826
20 February 2025
COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8082115
19 February 2025
Administrative Inspection · Simplified Stability Test
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8081351
12 March 2024
Administrative Inspection · Drydock Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7877655
9 January 2024
Administrative Inspection · Internal Structural Exam · Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7847000
13 January 2023
Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7621192
15 December 2022
In-Service Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7609783
29 November 2022
Administrative Inspection · COI Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7594329
14 October 2022
Simplified Stability Test · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7577194
21 April 2022
Hull Examination · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7434821
15 December 2020
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7111992
3 December 2020
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7105482
22 January 2020
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6893717
4 January 2019
Administrative Inspection · Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6605798
26 November 2018
Examination of Repairs · Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6587140
6 December 2017
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6319143
19 April 2017
In-Service Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6128454
2 March 2017
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6086294
18 November 2016
Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6043997
3 November 2015
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 5756608
14 June 2012
Examination of Repairs · Internal Structural Exam · Drydock Exam · COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4343683
23 September 2011
Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 4152774
6 September 2011
Internal Structural Exam · DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 4137687
7 September 2010
Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3844364
22 July 2009
Type not recorded
No type recorded · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3547313
14 July 2009
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 3534617
3 June 2008
Hull Examination · Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3220073
19 January 2008
Deficiency Check · Administrative Inspection · Damage Survey
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3133261
18 January 2008
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3135061
14 June 2007
COI Inspection · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2954438
12 June 2006
Administrative Inspection · Hull Examination · Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2677381
9 June 2005
Annual Inspection
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2384477
8 June 2004
Hull Examination · Annual Inspection
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2091878
17 June 2003
Annual Inspection
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1819559
11 June 2002
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1629431
29 April 2002
Hull Examination · COI Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1610960
9 October 2001
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1629378
5 February 2000
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 30399
Deficiency record · 86
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 17 March 2026
Resolved
Each survival craft required on a vessel by this part must meet the requirements provided in table 180.200(c). Vessel's 22 PAX life float was wasted and deteriorated. Vessel is limited to 24 total persons.
46 CFR 180.200(a)
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 17 March 2026
Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. Vessel did not have any muster and emergency instructions onboard.
46 CFR 185.510 (a)
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 17 March 2026
Resolved
Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and the other at the access to the propulsion machinery space. Vessel did not have any portable lights in the operating station and machinery space.
46 CFR 183.430
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 17 March 2026
Resolved
Vessel shall be provided with toilets and wash basins IAW Table 177.30-5(a). Vessel did not have any toilets.
46 CFR 177.30-5 (OLD T)
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 17 March 2026
Resolved
Each battery used in an item of lifesaving equipment, except inflatable survival craft equipment, must be replaced during the annual inspection if the expiration date of the battery has passed. Light for the PORT life float had the wrong batteries in accordance with manufacturer's requirements.
46 CFR 185.726(d)
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 26 March 2025
Resolved
All vessels except non-self-propelled vessels shall be provided with suitable steering apparatus. Port side rudder arm showed severe signs of corrosion and deterioration along with a bend in the metal. Repair or replace port side rudder arm to the satisfaction of the attending Marine Inspector.
46 CFR 182.30-1(a)
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 26 March 2025
Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspections. Marine Inspector found multiple dead end wires underneath cabin, in void space aft of operator station. Removed dead end wires to the satisfaction of the attending Marine Inspector.
46 CFR 183.01-15(a)
09 - Working and Living Conditions › 091 - Living Conditions › Sleeping room
Issued 26 March 2025
Resolved
All mattresses must comply with U.S. Department of Commerce "Standards for Mattress Flammability (FF 4-72.16, 16 CFR Part 1632, Subpart A and not contain polyurethane foam.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 26 March 2025
Resolved
Penetrations and openings in watertight bulkhead must have means to make them watertight. Observed bulkhead penetration on upper port side of bulkhead between rudder room and engine room to be non watertight.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 18 January 2024
Resolved
At each initial and subsequent inspection for certification, the marine inspector shall view the vessel afloat and shall conduct the following test and inspections of the hull structure and its appurtenances: Examine all accessible parts of the exterior and interior of the hull. Starboard outboard engine mount has two cracked welds and the Port rudder stop has a cracked weld at the base. Repair to the satisfaction of the attending Marine Inspector. 46 CFR 176.25-5(a)(1)
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 January 2024
Resolved
All wiring and cables shall be suitable for marine service and for the particular installation used. Vessel’s electrical system has many loose and or exposed wires in the engine room. Repair or replace wiring to the satisfaction of the attending Marine Inspector. 46 CFR 183.10-20(a)
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 18 January 2024
Resolved
A vessel must comply with the applicable requirements for any radio including the requirements for a station license and installation certificates to be issued by the FCC, as set forth in 47 CFR part 80. FCC Safety Radio Telephony Certificate is expired, correct to the satisfaction of the attending Marine Inspector. 46 CFR 184.502
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 27 December 2022
Resolved
Fire Detection - Vessels described by 46 CFR 175.110 (c) must have an interconnected fire detection system in compliance with 46 CFR 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces. Vessel has not installed the interconnected detection and alarm systems to meet the new regulations outlined in 181.450. Vessel will install and test to the satisfaction of the attending MI and the vessel will be limited to a route of limited coastwise. 46 CFR 181.405 (c)
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 29 November 2022
Resolved
Vessels described by 46 CFR 175.11 (c) must have an interconnected fire detection system in compliance with 46 CFR 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces. Must install a system to the satisfaction of the attending US Coast Guard Marine Inspector by 27DEC22.
46 CFR 181.405
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 29 November 2022
Resolved
All wiring and cables shall be suitable for marine service and for the particular installation used. Be installed with metal supports spaced not more than 24 inches apart. The use of plastic wraps must be limited to bundling. Vessel has cables on the and starboard side of the engine room and potable water space not supported and wired to metal supports. Correct to the satisfaction of the attending Coast Guard Marine Inspector.
46 CFR 183.10-20
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 29 November 2022
Resolved
Junction boxes for use in damp or wet locations shall be of watertight construction. Vessel had loose wiring and exposed junction box under the bridge console. Repair to the satisfaction of the attending Coast Guard Marine Inspector.
46 CF3.10-20(f)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 November 2022
Resolved
Guards shall be installed in way of all exposed and hazardous places. Ships service generator missing guard on starboard side. Repair to the satisfaction of the attending Coast Guard Marine Inspector.
46 CFR 177.35-15
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 29 November 2022
Resolved
A vessel must carry adequate and up to date charts to make safe navigation possible. Vessel has no means of viewing up to date charts. Repair to the satisfaction of the attending Coast Guard Marine Inspector.
46 CFR 184.420 (a)
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 29 November 2022
Resolved
All electronic installations shall be to the satisfaction of the Officer in Charge of Marine Inspections. Light switch cover missing on aft bulkhead inside cabin. Repair to the satisfaction of the attending Coast Guard Marine Inspector.
46 CFR 183.01-15
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 29 November 2022
Resolved
The bilge suctions shall be with suitable strainers having an open area not less than three times the area of the pipe. Missing screen to bilge suction. Repair to the satisfaction of the attending Coast Guard Marine Inspector.
46 CFR 182.25-5 (b)
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 29 November 2022
Resolved
A visual and audible alarm must be provided at the operating station. Cabin and lazarette alarms did not work. Repair to the satisfaction of the attending Coast Guard Marine Inspector.
46 CFR 182.530 (a)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 15 December 2020
Resolved
"On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces."
Visual alarm did not work at the operating station
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 January 2020
Resolved
Sea Rails, with suitable barriers to prevent accidental movement of cooking pots, must be installed on a cooking range. Install dividing sea rails to hold pots in place.
46CFR184.220(e)
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 22 January 2020
Resolved
Each battery used in an item of lifesaving equipment must be replaced during the annual inspection if the expiration date of the battery has passed. Battery in floating water light expired.
46CFR185.726(d)
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 January 2020
Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician in accordance with §80.59 once every five years. Ensure that the call signs on FCC documents (Safety Radiotelephone & Bridge-to-Bridge Certificate) match the
COI.
47CFR80.903
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 January 2020
Resolved
Connections must be made within an enclosure and the insulated cap of the connector must be secured. Remove dead-end wires or secure in an enclosure (junction box)
46CFR183.340(i)(1)
Navigation › Piloting/Steering › Marine Charts
Issued 9 November 2015
Resolved
Missing navigational paper chart of the area transiting.
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 9 November 2015
Resolved
Missing required diamond day shape.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 9 November 2015
Resolved
Lifeline on lifebuoy needs to be replaced due to deterioration.
Engineering › Fuel Oil Service System › Vent Pipe
Issued 9 November 2015
Resolved
Wrong flame screen mesh installed on port fuel oil vent line.
Navigation › Piloting/Steering › Marine Charts
Issued 3 December 2012
Resolved
Charts were 2008 ed. with no corrections.
Stability › Watertight Integrity › General
Issued 3 December 2012
Resolved
Several wire and cable runs were loose in the forward engineroom bulkhead.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 3 December 2012
Resolved
No emergency light existed for the crew accomodation space which below the main deck. Crew to install.
Navigation › Collision/Grounding Avoidance › Day Shapes
Issued 3 December 2012
Resolved
One of the two required ball day shapes was missing.
Navigation › Piloting/Steering › Compass Deviation Table
Issued 3 December 2012
Resolved
Compass deviation card was not onboard.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 3 December 2012
Resolved
Vessel name was missing from lights.
Engineering › Fuel Oil Service System › Piping
Issued 3 December 2012
Resolved
Main Diesel Engine fuel system contained several non metallic flexible hoses in excess of 7 feet. Required vessel to instal metallic piping to reduce the size of the flexible hose to a max of 30".
Electrical › Electrical Distribution System (service) › Switchboard
Issued 3 December 2012
Resolved
Breaker isolation bar was missing to prevent ship's power and shore power from being energized simultaneously.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 3 December 2012
Resolved
Switchboard ground detection system was inoperable.
Electrical › Electric Generation Source (service) › Generator
Issued 6 September 2011
Resolved
Repair or replace SSG starter and prove proper operation of SSG. SSG would not start.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 6 September 2011
Resolved
Repair port MDE exhaust line leak. Exhaust leaking at connection due to bolts not being secured and two bolts missing nuts.
Engineering › Fuel Oil Service System › Hose
Issued 6 September 2011
Resolved
Fuel feed lines to MDE are in poor condition and not of proper type. Replace accordingly.
Communications › Radio Communications › EPIRB
Issued 6 September 2011
Resolved
Replace EPRIB's hydro-static release with properly marked (expiration date) hydro-release.
Engineering › Steering Gear System › Hydraulic Hose
Issued 14 July 2009
Resolved
Repair hydraulic leak under bridge console.
Accommodation/Occupational Safety › Sleeping Accommodations › Berth
Issued 14 July 2009
Resolved
Replace/repair broken bunk lights.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 14 July 2009
Resolved
Properly mark lifejacket stowage location and quantity.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 14 July 2009
Resolved
Properly post appropriate donning instructions for each type of lifejacket carried.
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 July 2009
Resolved
Properly splice/secure all inappropriately connected electrical wires.
Electrical › Electrical Distribution System (service) › Outlet Box
Issued 14 July 2009
Resolved
Propely close/secure box holding potable water pump switch.
Engineering › Steering Gear System › Hydraulic Hose
Issued 14 July 2009
Resolved
properly secure loose hydraulic lines in space below main deck to prevent damage due to excessive vibration.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 14 July 2009
Resolved
Secure excessive water leak from potable water system near filter below main deck.
Engineering › Shafting/Propeller Arrangements › Coupling Bolt
Issued 14 July 2009
Resolved
Properly secure shaft packing on port and starboard shaft (double nut)
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 14 July 2009
Resolved
Double clamp all raw water hoses in engine room.
Electrical › Lighting (service) › Lighting Fixture
Issued 14 July 2009
Resolved
Place light protective globe at fixture above generator.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 14 July 2009
Resolved
Place appropriate guard over bilge pump belt.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 14 July 2009
Resolved
Mark/label bilge visual alarms on bridge.
Stability › Watertight Integrity › General
Issued 14 July 2009
Resolved
Make main deck hatches leading to machinery space watertight.
Lifesaving › Lifefloat › Painter
Issued 14 July 2009
Resolved
Replace painter on life float due to deterioration.
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 14 July 2009
Resolved
Repair leaks in raw water cooling system for generator.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 14 July 2009
Resolved
place appropriate lagging over exposed exhaust piping on main engines.
Engineering › Steering Gear System › Rudder
Issued 14 July 2009
Resolved
properly secure rudder post packing (double nut).
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 14 July 2009
Resolved
provide onboard a method to conduct alcohol testing.
Engineering › Generator (propulsion-electric) › Heating Element Circuitry
Issued 14 July 2009
Resolved
properly repair temp gauge on generator.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 14 July 2009
Resolved
hatch leading to stern area of cabin below deck shall be of sufficient size to make safe.
Stability › Weathertight Integrity › General
Issued 14 July 2009
Resolved
ensure hatch entering cabin at main deck is watertight.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 9 June 2008
Resolved
Missing insulation on exhaust piping
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 9 June 2008
Resolved
Vessel is re-located to new zone. All records and logs of drills are to be kept from this date forward.
Engineering › Bilge Water Management System › Not Installed
Issued 9 June 2008
Resolved
Bilge has excessive amount of oil in it. Must be pumped out at a receiving facility.
Electrical › Electrical Distribution System (service) › Cable
Issued 28 May 2008
Resolved
loose grounding cable rubbing on pully.
Construction/Loadline › Hull › Hull Plating
Issued 19 January 2008
Resolved
Transfer vessel to Bud's Boats repair yard and provide the local OCMI with repair proposal after surveying the full extent of damages throughout the vessel.
Construction/Loadline › Hull › Hull Plating
Issued 19 January 2008
Resolved
Prior to operating, upon approval of repairs by local OCMI, make repairs and schedule to have Coast Guard Marine Inspector assess repairs and structural integrity of the vessel.
Operations/Management › Drills/Instruction
Issued 29 April 2002
Resolved
Provide emergency instructions. LEGACY COMPONENT DESC: Emergency Instructions
Documentation › Logs/Records
Issued 29 April 2002
Resolved
Provide Refuse Log. LEGACY COMPONENT DESC: Garbage Recordkeeping
Navigation › Piloting/Steering
Issued 29 April 2002
Resolved
Provide C. G. Light List and notice to mariner updates. LEGACY COMPONENT DESC: Coast Guard Light List
Navigation › Piloting/Steering
Issued 29 April 2002
Resolved
Provide Navigation Rules. LEGACY COMPONENT DESC: Inland Navigation Rules
Operations/Management › Passenger Operations
Issued 29 April 2002
Resolved
Develop and provide passenger orientation. LEGACY COMPONENT DESC: Safety Orientation
Electrical › Lighting (emergency)
Issued 29 April 2002
Resolved
Provide 2 portable lights, for operating station and engine room. LEGACY COMPONENT DESC: Battery Operated Lantern
Communications › Alarms/Indicators
Issued 29 April 2002
Resolved
Repair port main engine tachometer. LEGACY COMPONENT DESC: Main Engine Tachometer
Fire Fighting › Miscellaneous Items
Issued 29 April 2002
Resolved
Provide 3 - 2.5 gal. fire buckets. LEGACY COMPONENT DESC: Fire Buckets
Lifesaving › Buoyant Apparatus
Issued 29 April 2002
Resolved
Service deteriorated lifefloats. LEGACY COMPONENT DESC: Lifefloats
Engineering › Fuel Oil Service System
Issued 29 April 2002
Resolved
Provide grounding strap on fuel tank fill pipes. LEGACY COMPONENT DESC: Piping
Stability › Watertight Integrity
Issued 29 April 2002
Resolved
Install stuffing tube in forward bulkhead of rudder room, port side. LEGACY COMPONENT DESC: Stuffing Tube
Fire Fighting › Combustible Materials
Issued 29 April 2002
Resolved
Remove all flammables from vessel or provide appropriate flammable locker. LEGACY COMPONENT DESC: Paints/Varnishes/Other Finishes
Accommodation/Occupational Safety › Sleeping Accommodations
Issued 29 April 2002
Resolved
Make emergency escape from crews berthing functional, it is nailed closed and tiled over. LEGACY COMPONENT DESC: Emergency Escape
Engineering › Bilge Water Management System
Issued 29 April 2002
Resolved
Provide hand portable bilge pump. LEGACY COMPONENT DESC: Pump
Communications › Visual Communication
Issued 29 April 2002
Resolved
Stencil water tight closures and emergency escapes with appropriate markings. LEGACY COMPONENT DESC: Water Tight Closures
Casualty record · 1
18 January 2008Routine · role: Involved in a Marine Casualty · activity 3135061
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.