Records from 2008 to 2026. Most recent: inspection, 17 March 2026.
Inspection history · 21
17 March 2026
Deficiency Check · Vessel Attendance · Annual Inspection · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8323727
20 February 2026
Vessel Attendance · Internal Structural Exam · Administrative Inspection · Examination of Repairs · Drydock Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8307177
14 July 2025
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8185826
20 February 2025
COI Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8082115
19 February 2025
Administrative Inspection · Simplified Stability Test
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8081351
12 March 2024
Administrative Inspection · Drydock Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7877655
9 January 2024
Administrative Inspection · Internal Structural Exam · Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7847000
13 January 2023
Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7621192
15 December 2022
In-Service Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7609783
29 November 2022
Administrative Inspection · COI Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7594329
14 October 2022
Simplified Stability Test · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7577194
21 April 2022
Hull Examination · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7434821
15 December 2020
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7111992
3 December 2020
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7105482
22 January 2020
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6893717
4 January 2019
Administrative Inspection · Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6605798
26 November 2018
Examination of Repairs · Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6587140
6 December 2017
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6319143
19 April 2017
In-Service Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6128454
2 March 2017
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6086294
18 November 2016
Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6043997
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 17 March 2026
Resolved
Each survival craft required on a vessel by this part must meet the requirements provided in table 180.200(c). Vessel's 22 PAX life float was wasted and deteriorated. Vessel is limited to 24 total persons.
46 CFR 180.200(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 April 2026
Resolved 19 March 2026
Resolution: Vessel installed 02 12 PAX life floats on the PORT side.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 17 March 2026
Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. Vessel did not have any muster and emergency instructions onboard.
46 CFR 185.510 (a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 March 2026
Resolved 19 March 2026
Resolution: Vessel posted emergency and muster instructions.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 17 March 2026
Resolved
Each vessel must be equipped with at least two operable portable battery lights. One of these lights must be located at the operating station and the other at the access to the propulsion machinery space. Vessel did not have any portable lights in the operating station and machinery space.
46 CFR 183.430
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 March 2026
Resolved 19 March 2026
Resolution: Vessel purchased 02 portable lights.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 17 March 2026
Resolved
Vessel shall be provided with toilets and wash basins IAW Table 177.30-5(a). Vessel did not have any toilets.
46 CFR 177.30-5 (OLD T)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 March 2026
Resolved 19 March 2026
Resolution: Vessel purchased 02 toilets.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 17 March 2026
Resolved
Each battery used in an item of lifesaving equipment, except inflatable survival craft equipment, must be replaced during the annual inspection if the expiration date of the battery has passed. Light for the PORT life float had the wrong batteries in accordance with manufacturer's requirements.
46 CFR 185.726(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 March 2026
Resolved 19 March 2026
Resolution: Vessel installed correct batteries for the PORT life float light.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 26 March 2025
Resolved
All vessels except non-self-propelled vessels shall be provided with suitable steering apparatus. Port side rudder arm showed severe signs of corrosion and deterioration along with a bend in the metal. Repair or replace port side rudder arm to the satisfaction of the attending Marine Inspector.
46 CFR 182.30-1(a)
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 2 April 2025
Resolution: Rudder arm repaired.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 26 March 2025
Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspections. Marine Inspector found multiple dead end wires underneath cabin, in void space aft of operator station. Removed dead end wires to the satisfaction of the attending Marine Inspector.
46 CFR 183.01-15(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 April 2025
Resolved 2 April 2025
Resolution: Dead end wires removed.
09 - Working and Living Conditions › 091 - Living Conditions › Sleeping room
Issued 26 March 2025
Resolved
All mattresses must comply with U.S. Department of Commerce "Standards for Mattress Flammability (FF 4-72.16, 16 CFR Part 1632, Subpart A and not contain polyurethane foam.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 April 2025
Resolved 2 April 2025
Resolution: Mattresses removed.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 26 March 2025
Resolved
Penetrations and openings in watertight bulkhead must have means to make them watertight. Observed bulkhead penetration on upper port side of bulkhead between rudder room and engine room to be non watertight.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 April 2025
Resolved 2 April 2025
Resolution: Bulkhead penetration sealed.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 18 January 2024
Resolved
At each initial and subsequent inspection for certification, the marine inspector shall view the vessel afloat and shall conduct the following test and inspections of the hull structure and its appurtenances: Examine all accessible parts of the exterior and interior of the hull. Starboard outboard engine mount has two cracked welds and the Port rudder stop has a cracked weld at the base. Repair to the satisfaction of the attending Marine Inspector. 46 CFR 176.25-5(a)(1)
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 February 2024
Resolved 2 February 2024
Resolution: All welds have been repaired, vessel is currently on a job and high quality pictures were submitted.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 January 2024
Resolved
All wiring and cables shall be suitable for marine service and for the particular installation used. Vessel’s electrical system has many loose and or exposed wires in the engine room. Repair or replace wiring to the satisfaction of the attending Marine Inspector. 46 CFR 183.10-20(a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 February 2024
Resolved 2 February 2024
Resolution: The electrical system has been corrected, vessel is on job and high quality pictures were submitted.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 18 January 2024
Resolved
A vessel must comply with the applicable requirements for any radio including the requirements for a station license and installation certificates to be issued by the FCC, as set forth in 47 CFR part 80. FCC Safety Radio Telephony Certificate is expired, correct to the satisfaction of the attending Marine Inspector. 46 CFR 184.502
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 February 2024
Resolved 2 February 2024
Resolution: Photo of new certificate was sumitted.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 27 December 2022
Resolved
Fire Detection - Vessels described by 46 CFR 175.110 (c) must have an interconnected fire detection system in compliance with 46 CFR 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces. Vessel has not installed the interconnected detection and alarm systems to meet the new regulations outlined in 181.450. Vessel will install and test to the satisfaction of the attending MI and the vessel will be limited to a route of limited coastwise. 46 CFR 181.405 (c)
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 18 January 2023
Resolution: System installed to the satisfaction of the attending MI.
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 29 November 2022
Resolved
Vessels described by 46 CFR 175.11 (c) must have an interconnected fire detection system in compliance with 46 CFR 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces. Must install a system to the satisfaction of the attending US Coast Guard Marine Inspector by 27DEC22.
46 CFR 181.405
Condition: Invalid
Action required: 705 - Other - as specified
Due 27 December 2022
Resolved 27 December 2022
Resolution: Vessel's route was restricted and a new CG 835V was issued.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 29 November 2022
Resolved
All wiring and cables shall be suitable for marine service and for the particular installation used. Be installed with metal supports spaced not more than 24 inches apart. The use of plastic wraps must be limited to bundling. Vessel has cables on the and starboard side of the engine room and potable water space not supported and wired to metal supports. Correct to the satisfaction of the attending Coast Guard Marine Inspector.
46 CFR 183.10-20
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 December 2022
Resolved 18 January 2023
Resolution: New brackets installed approximately every 24".
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 29 November 2022
Resolved
Junction boxes for use in damp or wet locations shall be of watertight construction. Vessel had loose wiring and exposed junction box under the bridge console. Repair to the satisfaction of the attending Coast Guard Marine Inspector.
46 CF3.10-20(f)
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 December 2022
Resolution: All wiring repaired and junction box cover installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 November 2022
Resolved
Guards shall be installed in way of all exposed and hazardous places. Ships service generator missing guard on starboard side. Repair to the satisfaction of the attending Coast Guard Marine Inspector.
46 CFR 177.35-15
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 December 2022
Resolved 18 January 2023
Resolution: Installed to the satisfaction of the attending MI.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 29 November 2022
Resolved
A vessel must carry adequate and up to date charts to make safe navigation possible. Vessel has no means of viewing up to date charts. Repair to the satisfaction of the attending Coast Guard Marine Inspector.
46 CFR 184.420 (a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 December 2022
Resolved 18 January 2023
Resolution: New charts provided.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 29 November 2022
Resolved
All electronic installations shall be to the satisfaction of the Officer in Charge of Marine Inspections. Light switch cover missing on aft bulkhead inside cabin. Repair to the satisfaction of the attending Coast Guard Marine Inspector.
46 CFR 183.01-15
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 December 2022
Resolution: Cover installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 29 November 2022
Resolved
The bilge suctions shall be with suitable strainers having an open area not less than three times the area of the pipe. Missing screen to bilge suction. Repair to the satisfaction of the attending Coast Guard Marine Inspector.
46 CFR 182.25-5 (b)
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 27 December 2022
Resolution: Strainer screen installed.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 29 November 2022
Resolved
A visual and audible alarm must be provided at the operating station. Cabin and lazarette alarms did not work. Repair to the satisfaction of the attending Coast Guard Marine Inspector.
46 CFR 182.530 (a)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 29 November 2022
Resolution: Corrected before we departed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 15 December 2020
Resolved
"On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces."
Visual alarm did not work at the operating station
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 15 December 2020
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 January 2020
Resolved
Sea Rails, with suitable barriers to prevent accidental movement of cooking pots, must be installed on a cooking range. Install dividing sea rails to hold pots in place.
46CFR184.220(e)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 February 2020
Resolved 22 January 2020
Resolution: Received pictures of newly installed sea rail.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 22 January 2020
Resolved
Each battery used in an item of lifesaving equipment must be replaced during the annual inspection if the expiration date of the battery has passed. Battery in floating water light expired.
46CFR185.726(d)
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 22 January 2020
Resolved 22 January 2020
Resolution: Purchased new batteries and replaced expired battery.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 January 2020
Resolved
Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician in accordance with §80.59 once every five years. Ensure that the call signs on FCC documents (Safety Radiotelephone & Bridge-to-Bridge Certificate) match the
COI.
47CFR80.903
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 February 2020
Resolved 15 December 2020
Resolution: During annual inspection they provided information.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 January 2020
Resolved
Connections must be made within an enclosure and the insulated cap of the connector must be secured. Remove dead-end wires or secure in an enclosure (junction box)
46CFR183.340(i)(1)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 February 2020
Resolved 15 December 2020
Resolution: Witnessed duing annual inspection.