Records from 1984 to 1992. Most recent: inspection, 31 July 1992.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 17
31 July 1992
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1264201
31 January 1992
Permit to Proceed
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1249808
7 November 1990
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1230069
15 December 1987
Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1312850
26 March 1987
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1327029
16 January 1987
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1314945
3 July 1986
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 987823
25 March 1986
Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1306573
9 January 1986
COI Inspection · Credit Drydock
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 993574
16 May 1985
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1290042
28 April 1985
Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 979450
4 March 1985
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1288018
15 January 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 977642
11 April 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 978977
26 March 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 973438
29 January 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 972435
6 January 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1278593
Lifesaving
Issued 16 January 1987
Resolved
REPAIR OR REPLACE THE EMERGENCY EYE WASH STATION AT THE CHEMICAL BENCH IN THE MUD PIT ROOM.
Condition: Unknown
Due 16 January 1987
Resolved 16 January 1987
Electrical
Issued 16 January 1987
Resolved
MAKE REPAIRS TO THE EXHAUST MUFFLER AND DISCHARGE PIPING FOR THE NUMBER 3 ELECTRICAL GENERATOR.
Condition: Unknown
Due 16 January 1987
Resolved 16 January 1987
Accommodation/Occupational Safety
Issued 16 January 1987
Resolved
REMOVE THE HASPS ON THE WEATHERTIGHT DOORS AROUND THE WEATHER DECK OF THE STRUCTURE.
Condition: Unknown
Due 16 January 1987
Resolved 16 January 1987
Construction/Loadline
Issued 3 July 1986
Resolved
MAKE PERMANENT REPAIRS TO THE FOLLOWING SPUD LEGS PRIOR TO PLACING RIG BACKINTO SERVICE (A) BOW LEG: MINOR CRACKS IN TOP WELDS OF CHORD TO CAN CONNECTIONS ON FOUR OF EIGHT SIDES.
Condition: Unknown
Due 9 January 1988
Resolved 3 July 1986
Construction/Loadline
Issued 3 July 1986
Resolved
(B) PORT LEG: FULL LENGTH CRACK ON FORWARD CHORD TO CAN CONNECTION OUTBOARD SIDE AND LARGE FRACTURE TO CHORD SUPPORT GUSSET ON INBOARD CAN TO CHORD CONNECTION. (C) STBD LEG: FULL LENGTH CRACKS ON 5 OF 8 SIDES OF CHORD TO CAN CONNECTIO
Condition: Unknown
Due 9 January 1988
Resolved 3 July 1986
Construction/Loadline
Issued 3 July 1986
Resolved
CONDUCT VISUAL EXAM OF REMAINING CHORD TO CAN CONNECTIONS ON PORT LEG.
Condition: Unknown
Due 9 January 1988
Resolved 3 July 1986
Construction/Loadline
Issued 9 January 1986
Resolved
COMPLETE THE UNDERWATER PORTION OF THE SPECIAL UNDERWATER SURVEY IN LIEU OFDRYDOCKING PRIOR TO 09JUL86.
Condition: Unknown
Due 9 January 1986
Resolved 9 January 1986
Electrical
Issued 9 January 1986
Resolved
CONDUCT GENERATOR TESTS IN THE PRESENCE OF A COAST GUARD MARINE INSPECTOR PRIOR TO 09FEB86.
Condition: Unknown
Due 9 January 1986
Resolved 9 January 1986
Construction/Loadline
Issued 9 January 1986
Resolved
PRIOR TO THE NEXT RIG MOVE BUT NOT LATER THAN 09FEB86, EFFECT PERMANENT REPAIRS OR RENEW INOPERATIVE PRELOAD TANK NON-RETURN VALVES.
Condition: Unknown
Due 9 January 1986
Resolved 9 January 1986
Engineering
Issued 9 January 1986
Resolved
MAKE THE AIR RECIEVER AVAILABLE FOR INTERNAL EXAMINATION OR HYDROSTATICALLYTEST DURING THE NEXT RIG MOVE BUT NOT LATER THAN 09FEB86.
Condition: Unknown
Due 9 January 1986
Resolved 9 January 1986
Lifesaving
Issued 28 April 1985
Resolved
CONDUCT ANNUAL SERVICING FOR BOTH D/L LIFERAFTS.
Condition: Unknown
Due 28 April 1985
Resolved 28 April 1985
Electrical
Issued 15 January 1985
Resolved
MAKE SUITABLE FOR DIVISION II HAZARDOUS LOCATIONS THE MUD PIT FORWARD SPEAKER. 46 CFR 111.92
Condition: Unknown
Due 15 January 1985
Resolved 15 January 1985
Electrical
Issued 15 January 1985
Resolved
PROVIDE CEMENT TO THE EYS FITTING OF THE PORT GENERAL ALARM BELL OF THE MUD PIT. 46 CFR 111.92.
Condition: Unknown
Due 15 January 1985
Resolved 15 January 1985
Construction/Loadline
Issued 15 January 1985
Resolved
PROVIDE FUEL OIL TANK VENTS THAT TERMINATE ABOVE THE MAIN DECK. 46 CFR 56.50-85.
Condition: Unknown
Due 15 January 1985
Resolved 15 January 1985
Lifesaving
Issued 15 January 1985
Resolved
REPAIR THE AIR SUPPLY PIPING IN THE NO 2 LIFEBOAT. 46 CFR 108.503.
Condition: Unknown
Due 15 January 1985
Resolved 15 January 1985
Unknown
Issued 15 January 1985
Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE VESSEL, PENROD 59, DN518632 AND ARE TO BE COMPLIED WITH BY 15FEB85.
Condition: Unknown
Due 15 January 1985
Resolved 15 January 1985
Lifesaving
Issued 15 January 1985
Resolved
PROVIDE A SOO FOOT AUXILIARY LINE TO THE LINE THROWING GUN. 46 CFR 108.152
Condition: Unknown
Due 15 January 1985
Resolved 15 January 1985
Electrical
Issued 15 January 1985
Resolved
REPAIR THE MAIN ENGINE ALARM PANEL. 46 CFR 111.10-5
Condition: Unknown
Due 15 January 1985
Resolved 15 January 1985
Electrical
Issued 15 January 1985
Resolved
PROVIDE A MEANS OF CLOSING THE FUEL OIL DAY TANK SUPPLY VALVE FROM OUTSIDE THE ENGINE ROOM. 46 CFR 56.60-50(A)(1).
Condition: Unknown
Due 15 January 1985
Resolved 15 January 1985
Construction/Loadline
Issued 15 January 1985
Resolved
REPAIR THE HIGH BILGE ALARM IN THE BILGE PUMP SPACE.
Condition: Unknown
Due 15 January 1985
Resolved 15 January 1985
Electrical
Issued 15 January 1985
Resolved
PROVIDE CEMENT IN THE DESANDER MOTOR AND CONTROLLER ELECTRICAL CONNECTIONS.46 CFR 111.92.
Condition: Unknown
Due 15 January 1985
Resolved 15 January 1985
Lifesaving
Issued 6 January 1984
Resolved
CONDUCT A WEIGHT TEST OF THE DAVIT AND WINCH FOR THE DAVIT LAUNCHED INFLAT-ABLE LIFERAFT ASSEMBLY - 46 CFR 107.239.
Condition: Unknown
Due 6 January 1984
Resolved 6 January 1984
Unknown
Issued 6 January 1984
Resolved
REQUIREMENT 9 CONT. 46 CFR 107.267.
Condition: Unknown
Due 6 January 1984
Resolved 6 January 1984
Electrical
Issued 6 January 1984
Resolved
SUBMIT HAZARDOUS LOCATION PLAN TO THE OIC MARINE INSPECTION NEW ORLEANS FORREVIEW - 46 CFR 107.305.
Condition: Unknown
Due 6 January 1984
Resolved 6 January 1984
Unknown
Issued 6 January 1984
Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE MODU PENROD 59 DN518632
Condition: Unknown
Due 6 January 1984
Resolved 6 January 1984
Construction/Loadline
Issued 6 January 1984
Resolved
REVIEW THE VESSEL RECORDS TO DETERMINE IF ANY HIGH STRENGTH STEELS WERE USED IN THE CONSTRUCTION OF THIS VESSEL. REPORT FINDINGS TO THE OIC
Condition: Unknown
Due 6 January 1984
Resolved 6 January 1984
Construction/Loadline
Issued 6 January 1984
Resolved
MAKE AVAILABLE FOR INSPECTION, BOTH INTERNAL AND LEG TO SPUD CAN CONNECT- IONS, ALL THREE SPUD CANS IN CONNECTION WITH THE SPECIAL IN LIEU OF DRYDOCK
Condition: Unknown
Due 6 January 1984
Resolved 6 January 1984
Unknown
Issued 6 January 1984
Resolved
REQUIREMENT 8 CONT. MARINE INSPECTION NEW ORLEANS 46 CFR 107.305.
Condition: Unknown
Due 6 January 1984
Resolved 6 January 1984
Unknown
Issued 6 January 1984
Resolved
REQUIREMENT 12 CONT. 46 CFR 108.503.
Condition: Unknown
Due 6 January 1984
Resolved 6 January 1984
Lifesaving
Issued 6 January 1984
Resolved
PROVIDE ONE ADDITIONAL LIFEBOAT FOR THE VESSEL. INSTALLATION AND TESTING SHALL BE TO THE SATISFACTION OF THE COGNIZANT OIC MARINE INSPECTION,
Condition: Unknown
Due 6 January 1984
Resolved 6 January 1984
Lifesaving
Issued 6 January 1984
Resolved
MARK THE STERN OF THE RIG WITH THE HOMEPORT. MARK THE LIFEBOAT WITH THE CORRECT HOMEPORT.
Condition: Unknown
Due 6 January 1984
Resolved 6 January 1984
Unknown
Issued 6 January 1984
Resolved
REQUIREMENT 7 CONT. PLATE THICKNESS OF AREAS GAUGED WITH THE REPORT.
Condition: Unknown
Due 6 January 1984
Resolved 6 January 1984
Construction/Loadline
Issued 6 January 1984
Resolved
GAUGE THE FORWARD MUDPIT BULKHEAD AND PROVIDE WRITTEN RESULTS OF THE INSPECTION TO THE OIC MARINE INSPECTION NEW ORLEANS, INCLUDE THE ORIGINAL
Condition: Unknown
Due 6 January 1984
Resolved 6 January 1984
Unknown
Issued 6 January 1984
Resolved
REQUIREMENT 6 CONT. NEW ORLEANS, INCLUDE ORIGINAL PLATE THICKNESS OF AREAS GAUGED WITH REPORT.
Condition: Unknown
Due 6 January 1984
Resolved 6 January 1984
Construction/Loadline
Issued 6 January 1984
Resolved
GAUGE THE BOTTOM SHELL PLATING OF THE VESSEL IN WAY OF THE VISABLE WASTAGE IN THE FUEL TANK #8. PROVIDE WRITTEN RESULTS TO THE OIC MARINE INSPECTION
Condition: Unknown
Due 6 January 1984
Resolved 6 January 1984
Construction/Loadline
Issued 6 January 1984
Resolved
MAKE AVAILABLE FOR INSPECTION, TWO PRELOAD VALVES - 46 CFR 61.20-5.
Condition: Unknown
Due 6 January 1984
Resolved 6 January 1984
Lifesaving
Issued 6 January 1984
Resolved
PROVIDE FLOODLIGHTS FOR ILLUMINATION OF THE LIFEBOAT AND LIFERAFTS FROM THESTOWED POSITION TO THE WATER, 46 CFR 111.75-16.
Condition: Unknown
Due 6 January 1984
Resolved 6 January 1984
Deck/Cargo
Issued 6 January 1984
Resolved
PROVIDE CURRENT CRANE CERTIFICATES FOR ALL CRANES ON BOARD THE RIG. 46 CFR 107.258.
Condition: Unknown
Due 6 January 1984
Resolved 6 January 1984
Fire Fighting
Issued 6 January 1984
Resolved
SUBMIT FIRE CONTROL PLAN TO THE OIC MARINE INSPECTION NEW ORLEANS FOR RE- VIEW - 46 CFR 107.305. POST APPROVED COPY UPON RECEIPT.
Condition: Unknown
Due 6 January 1984
Resolved 6 January 1984