Records from 1984 to 1997. Most recent: inspection, 27 September 1997.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 27
27 September 1997
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 408369
27 September 1997
Letter of Compliance (Initial/Renewal)
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 783750
28 December 1993
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 110528
18 October 1993
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 538270
11 November 1992
Certificate of Compliance
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1138104
11 November 1992
Certificate of Compliance
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1139058
13 September 1991
Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 937209
14 August 1990
Certificate of Compliance
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 914251
26 June 1989
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1202635
25 February 1989
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 439660
23 December 1988
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 524104
3 August 1988
Type not recorded
No type recorded · THE UNKNOWN UNIT · Activity 1342776
25 May 1988
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 454978
25 May 1988
Certificate of Compliance
Administrative · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1194192
17 July 1987
Administrative
Administrative · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1023294
1 July 1987
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 493017
1 July 1987
Deficiency Check
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1011232
30 June 1987
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1008887
30 June 1987
MARPOL Annex II Examination
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1321060
8 December 1986
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 498210
15 September 1986
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 311425
2 August 1986
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 310458
8 July 1986
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 309998
29 May 1986
Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 309167
29 May 1986
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 988097
8 March 1986
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 530979
24 April 1984
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1286380
Deck/Cargo
Issued 13 September 1991
Resolved
PROVE PROPER OPERATION OR PROVIDE CLASS SOCIETY DOCUMENTATION ATTESTING TO THE SATISFACTORY OPERATION OF INERT GAS SYSTEMS PRIOR TO TRANSFERING CARGO AT NEXT U.S. PORT.
Condition: Unknown
Due 16 September 1991
Resolved 16 September 1991
Unknown
Issued 14 August 1990
Resolved
REPAIR THE PORT AND STBD CARGO MANIFOLD QUICK CLOSING VALVES.
Condition: Unknown
Due 14 August 1990
Resolved 14 August 1990
Engineering
Issued 14 August 1990
Resolved
MAKE PERMANENT REPAIRS TO THE GAS DETECTION SYSTEM.
Condition: Unknown
Due 14 August 1990
Resolved 14 August 1990
Navigation
Issued 30 June 1987
Resolved
PLACE ON BOARD CURRENT U.S. COAST PILOT, COAST GUARD LIGHT LIST, AND ALL RECENT NOTICES TO MARINERS.
Condition: Unknown
Due 30 June 1987
Resolved 30 June 1987
Navigation
Issued 30 June 1987
Resolved
CORRECT ALL HOUSTON SHIP CHANNEL CHARTS OR PLACE ABOARD NEW ONES PRIOR TO DEPARTURE FROM HOUSTON.
Condition: Unknown
Due 30 June 1987
Resolved 30 June 1987
Deck/Cargo
Issued 30 June 1987
Resolved
PRIOR TO LOADING ANY CARGO IN U.S. WATERS, OBTAIN SUITABLE, CERTIFIED SPAN GAS AND CALIBRATE THE FIXED GAS DETECTION SYSTEM TO THE SATISFACTION OF A USCG MARINE INSPECTOR.
Condition: Unknown
Due 30 June 1987
Resolved 30 June 1987
Deck/Cargo
Issued 30 June 1987
Resolved
PRIOR TO CARRYING ACETALDEHYDE OR PROPYLENE OXIDE IN U.S. WATERS, DEMON- STRATE COMPLIANCE WITH MARPOL ANNEX II TO THE SATISFACTION OF A USCG MARINE INSPECTOR.
Condition: Unknown
Due 30 June 1987
Resolved 30 June 1987
Deck/Cargo
Issued 8 July 1986
Resolved
VESSEL DID NOT HAVE PORTABLE VCM MONITORS ON BOARD AS REQUIRED BY 46CFR40.15.
Condition: Unknown
Due 8 July 1986
Resolved 8 July 1986
Fire Fighting
Issued 29 May 1986
Resolved
REMOVE ALL FLAMMABLE STORES FROM THE FORCASTLE PAINT LOCKER TO A SUITABLE STORAGE LOCKER I.E. ONE WITH VAPOR TIGHT BULKHEADS AND EXPLOSION PROOF ELECTRICAL FIXTURES.
Condition: Unknown
Due 29 May 1986
Resolved 29 May 1986
Deck/Cargo
Issued 29 May 1986
Resolved
PROVIDE CARGO TANK GAUGING AND MEASURNG CONNECTIONS WHICH COMPLY WITH 46 CFR 154.536.
Condition: Unknown
Due 29 May 1986
Resolved 29 May 1986
Fire Fighting
Issued 29 May 1986
Resolved
MAKE PERMANENT REPAIRS TO BROKEN EXPLOSION PROOF LIGHT FIXTURE LOCATED IN THE FORWARD PORT DECK STORAGE LOCKER.
Condition: Unknown
Due 29 May 1986
Resolved 29 May 1986