MAURY USCG vessel records Sign in
← All vessels

PRIDE WYOMING

PRIDE WYOMING is a 1976 mobile offshore drilling unit. The Coast Guard has recorded 57 inspections since 1984, most recently in June 2008, along with 85 deficiencies — 3 with no resolution recorded —.

Records from 1984 to 2008. Most recent: inspection, 18 June 2008.

Built
1976
Last inspected
18 June 2008
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8751708 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
HP8085
228969
Flag
LIBERIA
—
Maury page id
psix-228969

Inspections, by type

…with no type recorded18
Years with a record 21 calendar years (1984–2008)
The 57 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it1507 - Regulatory (Subpart C or D), Net Ton
5025 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

LA MARIE Towing Vessel · MISLE 103588 · 18 October 2006 · activity 2804466

Inspection history · 57

18 June 2008 Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3240777
19 May 2008 COC-CVE Annual
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3221588
30 March 2008 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3173887
16 February 2008 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3148504
25 January 2008 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3136254
1 April 2007 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2901728
20 March 2007 COC-MODU Renew
Type not classified · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2871601
28 February 2007 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2879538
18 October 2006 Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2804466
19 July 2006 Type not recorded
No type recorded · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2726328
8 March 2006 COC-MODU Annual
Type not classified · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 2585136
27 January 2005 COC-MODU Renew
Type not classified · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2256532
11 October 2001 Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1443274
22 June 2001 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1066958
14 April 2001 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1061586
6 March 2001 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1060625
11 October 2000 Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1401338
27 September 2000 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1054132
17 May 2000 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 818285
14 October 1999 Letter of Compliance (Initial/Renewal)
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1378831
19 May 1999 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 797781
21 October 1998 Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1457603
19 October 1998 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 801273
13 October 1998 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1132042
17 March 1998 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1107681
9 December 1997 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 780218
21 October 1997 Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1460124
13 October 1997 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1109679
23 September 1997 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 12706
10 July 1997 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1114653
27 April 1997 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1104384
22 October 1996 Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1453280
1 November 1995 Letter of Compliance (Initial/Renewal)
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1421031
26 September 1995 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 878430
13 March 1995 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1172788
23 January 1995 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 857109
21 November 1994 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 868431
2 November 1994 Letter of Compliance (Initial/Renewal)
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1355001
15 September 1994 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 869269
15 September 1994 Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1180203
10 August 1994 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1176654
28 June 1994 Type not recorded
No type recorded · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 135626
3 November 1993 Certificate of Compliance
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1160000
1 April 1993 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 683856
25 March 1993 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 11974
3 November 1992 Certificate of Compliance
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1139798
14 January 1992 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 960141
27 September 1991 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 946468
29 August 1991 Certificate of Compliance
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 946738
19 June 1991 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1201204
13 May 1991 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 904685
30 August 1990 Certificate of Compliance
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1233782
6 September 1989 Certificate of Compliance
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 899991
8 September 1988 Certificate of Compliance
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1194278
2 September 1987 Certificate of Compliance
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1018956
24 June 1986 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1307649
9 April 1984 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 972911

Deficiency record · 85

Engineering › Diesel Engine (propulsion/auxiliary-electric) › Overspeed Device
Issued 20 March 2007 No resolution recorded
Overspeed protection on #2 and #4 Generator failed to work.
Action required: 705 - Other - as specified
Engineering › Pressure Vessel › Relief Valve
Issued 20 March 2007 No resolution recorded
No record of test on Pressure Relief Valves.
Action required: 705 - Other - as specified
Communications › Alarms/Indicators › Fire Alarm
Issued 20 March 2007 No resolution recorded
No audiable fire alarm in Mechanic Shop
Action required: 705 - Other - as specified
Lifesaving
Issued 11 October 2001 Resolved
Provide copy of PRIDE WYOMING station bill for minimum manning.
Condition: Unknown
Due 18 October 2001
Resolved 24 October 2001
Fire Fighting › Miscellaneous Items › B Class Division Penetrations
Issued 11 October 2001 Resolved
Conduct fire and abandon drills in the presence of Coast Guard Inspector prior to commencing operations.
Condition: Unknown
Due 1 December 2001
Resolved 24 March 2005
Resolution: Conducted fire and abandon ship drills.
Documentation
Issued 11 October 2001 Resolved
Provide copy of Panamanian exemption to have immersion suits and lifeboat rations to [name withheld].
Condition: Unknown
Due 18 October 2001
Resolved 24 October 2001
Navigation
Issued 11 October 2000 Resolved
CONDUCT AND PROPERLY LOG MONTHLY EPRIB TESTS.
Condition: Unknown
Due 25 October 2000
Resolved 25 October 2000
Construction/Loadline
Issued 11 October 2000 Resolved
REPAIR HOLE IN LOWER BULKHEAD CORNER TO MUD PITS AT DOOR TO SATISFACTION OFCLASS SURVEYOR.
Condition: Unknown
Due 25 October 2000
Resolved 25 October 2000
Lifesaving
Issued 14 October 1999 Resolved
CONDUCT FIRE DRILL AND ABANDON SHIP DRILL IN THE PRESENCE OF A USCG MARINE INSPECTOR PRIOR TO COMMENCING DRILLING OPERATIONS.
Condition: Unknown
Due 14 October 1999
Resolved 14 October 1999
Lifesaving
Issued 21 October 1998 Resolved
CONDUCT 1.1 RELEASE GEAR OPERATIONAL TEST ON BOTH LIFEBOATS. ALTERNATE TESTMUST BE APPROVED BY THE COGNIZANT OCMI.
Condition: Unknown
Due 21 October 1998
Resolved 21 October 1998
Navigation
Issued 21 October 1997 Resolved
REPAIR FOG HORN.
Condition: Unknown
Due 21 October 1997
Resolved 21 October 1997
Documentation
Issued 21 October 1997 Resolved
REVISE STATION BILL, OPERATIONS MANUAL, FIRE CONTROL AND SAFETY PLAN AND HAZARDOUS LOCATION PLAN TO REFLECT NAME CHANGE.
Condition: Unknown
Due 21 October 1997
Resolved 21 October 1997
Lifesaving
Issued 21 October 1997 Resolved
IMPLEMENT POLICY TO LOWER LIFEBOATS AND OPERATE LIFERAFT DAVIT AT EACH DRILL IN ACCORDANCE WITH 46 CFR 109.213(d).
Condition: Unknown
Due 21 October 1997
Resolved 21 October 1997
Lifesaving
Issued 21 October 1997 Resolved
MAKE GENERAL ALARM AUDIBLE AT ALL LOCATIONS ON RIG.
Condition: Unknown
Due 21 October 1997
Resolved 21 October 1997
Fire Fighting
Issued 21 October 1997 Resolved
MAKE REPAIRS TO FIREFIGHTING EQUIPMENT IN ACCORDANCE WITH TOTAL SAFETY REPORT, DATED OCTOBER 11, 1997. REPLACE B-V SEMI-PORTABLE FIRE EXTINGUISHER ON HELIDECK.
Condition: Unknown
Due 21 October 1997
Resolved 21 October 1997
Electrical
Issued 21 October 1997 Resolved
MAKE MUD PIT DOORS SELF-CLOSING AND GAS TIGHT.
Condition: Unknown
Due 21 October 1997
Resolved 21 October 1997
Construction/Loadline
Issued 21 October 1997 Resolved
PLACE NAME OF VESSEL AND HAILING PORT ON HULL IN ACCORDANCE WITH _x001C_ 46 CFR 67.15.
Condition: Unknown
Due 21 October 1997
Resolved 21 October 1997
Unknown
Issued 21 October 1997 Resolved
INSTALL SAFETY RELIEF VALVE ON RIG STARTING AIR COMPRESSOR SYSTEM BETWEEN COMPRESSOR DISCHARGE AND ISOLATION VALVE.
Condition: Unknown
Due 21 October 1997
Resolved 21 October 1997
Electrical
Issued 21 October 1997 Resolved
CONDUCT SATISFACTORY TEST OF THE TOTAL RIG EMERGENCY SHUTDOWN SYSTEM IN THEPRESENCE OF A CLASSIFICATION SOCIETY SURVEYOR.
Condition: Unknown
Due 21 October 1997
Resolved 21 October 1997
Lifesaving
Issued 21 October 1997 Resolved
MAKE REPAIRS TO LIFEBOATS IN ACCORDANCE WITH SURVIVAL SYSTEMS REPORT, DATEDOCTOBER 6, 1997. REPLACE LIFELINE ON LIFEBOAT NO. 2 AND JACKKNIFE ON LIFEBOAT NO. 1.
Condition: Unknown
Due 21 October 1997
Resolved 21 October 1997
Lifesaving
Issued 21 October 1997 Resolved
PROPERLY LABEL ALL HAZARDOUS MATERIALS.
Condition: Unknown
Due 21 October 1997
Resolved 21 October 1997
Lifesaving
Issued 21 October 1997 Resolved
IMPLEMENT POLICY TO LAUNCH LIFEBOAT EVERY THREE MONTHS WITH THE ASSIGNED OPERATING CREW.
Condition: Unknown
Due 21 October 1997
Resolved 21 October 1997
Lifesaving
Issued 21 October 1997 Resolved
IMPLEMENT POLICY TO CONDUCT AND LOG DAVIT-LAUNCHED LIFERAFT TRAINING AT INTERVALS OF NOT MORE THAN FOUR MONTHS.
Condition: Unknown
Due 21 October 1997
Resolved 21 October 1997
Lifesaving
Issued 21 October 1997 Resolved
IMPLEMENT POLICY TO INSTRUCT THE CREW AND INDUSTRIAL PERSONNEL IN THE USE OF THE UNIT'S FIRE EXTINGUISHING APPLIANCES, LIFESAVING APPLIANCES AND IN SURVIVAL AT SEA AT THE SAME INTERVAL AS EACH REQUIRED DRILL AND LOG APPROPRIATELY.
Condition: Unknown
Due 21 October 1997
Resolved 21 October 1997
Lifesaving
Issued 21 October 1997 Resolved
IMPLEMENT POLICY FOR PERSON-IN-CHARGE TO ENTER A STATEMENT IN THE LOG BOOK STATING ADEQUATE REASONS FOR NOT CONDUCTING THE REQUIRED DRILLS AND TRAINING.
Condition: Unknown
Due 21 October 1997
Resolved 21 October 1997
Lifesaving
Issued 21 October 1997 Resolved
IMPLEMENT POLICY TO CONDUCT WEEKLY, MONTHLY AND ANNUAL INSPECTIONS OF SAFETY EQUIPMENT IN ACCORDANCE WITH 46 CFR 109.301.
Condition: Unknown
Due 21 October 1997
Resolved 21 October 1997
Electrical
Issued 21 October 1997 Resolved
REPAIR ELECTRICAL JUNCTION BOX IN MUD PIT ROOM.
Condition: Unknown
Due 21 October 1997
Resolved 21 October 1997
Lifesaving
Issued 21 October 1997 Resolved
PLACE ABANDONMENT TRAINING MATERIALS ON BOARD IN ACCORDANCE WITH 46 CFR 109.213.
Condition: Unknown
Due 21 October 1997
Resolved 21 October 1997
Lifesaving
Issued 22 October 1996 Resolved
REPLACE ROCKET LINE THROWING GUN CARTRIDGES.
Condition: Unknown
Due 22 October 1996
Resolved 22 October 1996
Fire Fighting
Issued 22 October 1996 Resolved
MAKE REPAIRS TO FIREFIGHTING SYSTEMS IN ACCORDANCE WITH FIRE MASTER REPORT,DATED 16SEP96.
Condition: Unknown
Due 22 October 1996
Resolved 22 October 1996
Lifesaving
Issued 22 October 1996 Resolved
HOLD LINE THROWING DRILLS AND INSPECT EPIRB. LOG ACCORDINGLY.
Condition: Unknown
Due 22 October 1996
Resolved 22 October 1996
Unknown
Issued 22 October 1996 Resolved
REPAIR BILGE SUCTION SYSTEM IN ENGINE ROOM AND PROVE PROPER OPERATION.
Condition: Unknown
Due 22 October 1996
Resolved 22 October 1996
Construction/Loadline
Issued 1 November 1995 Resolved
REPAIR WASTED AREA OF HATCH COAMING FOR HATCH TO MUD PIT ROOM.
Condition: Unknown
Due 1 November 1995
Resolved 1 November 1995
Construction/Loadline
Issued 1 November 1995 Resolved
REPAIR WATERTIGHT DOORS IN ACCORDANCE WITH ABS WORKLIST.
Condition: Unknown
Due 1 November 1995
Resolved 1 November 1995
Navigation
Issued 1 November 1995 Resolved
CONDUCT INTERNAL EXAMINATION AND TEST OF RELIEF VALVES OF ALL PRESSURE VESSELS TO THE SATISFACTION OF AUTHORIZED FLAG STATE REPRESENTATIVE.
Condition: Unknown
Due 1 November 1995
Resolved 1 November 1995
Construction/Loadline
Issued 1 November 1995 Resolved
REPAIR WASTED STIFFENERS AND SUPPORT PIPING FOR OVERHEAD TO SHALE SHAKER AREA.
Condition: Unknown
Due 1 November 1995
Resolved 1 November 1995
Electrical
Issued 1 November 1995 Resolved
PROVIDE NON-CONDUCTIVE MATTING FOR DECK IN FRONT OF SWITCHBOARD IN EMERGENCY GENERATOR ROOM.
Condition: Unknown
Due 16 November 1995
Resolved 16 November 1995
Fire Fighting
Issued 1 November 1995 Resolved
REPAIR LEAK AROUND SHAFT ON #2 FIRE PUMP.
Condition: Unknown
Due 1 November 1995
Resolved 1 November 1995
Electrical
Issued 1 November 1995 Resolved
SECURE ELECTRICAL CABLES ON DERRICK FOR DERRICK LIGHTING.
Condition: Unknown
Due 16 November 1995
Resolved 16 November 1995
Electrical
Issued 2 November 1994 Resolved
REPAIR REVERSE CURRENT RELAY ON #2 SSG.
Condition: Unknown
Due 2 November 1994
Resolved 2 November 1994
Lifesaving
Issued 2 November 1994 Resolved
REPLACE FIRST AID KITS IN LIFEBOATS 1 AND 2.
Condition: Unknown
Due 2 November 1994
Resolved 2 November 1994
Deck/Cargo
Issued 2 November 1994 Resolved
UPON COMPLETION OF REPAIRS TO STBD CRANE, CONDUCT WEIGHT TEST AS PER CLASS SOCIETY SPECIFICATIONS, PROVIDE DOCUMENTATION.
Condition: Unknown
Due 2 November 1994
Resolved 2 November 1994
Engineering
Issued 2 November 1994 Resolved
LABEL F/O TRANSFER HOSE "FUEL OIL ONLY".
Condition: Unknown
Due 2 November 1994
Resolved 2 November 1994
Electrical
Issued 3 November 1993 Resolved
PROVE PROPER OPERATION OF DRILLERS CONSOLE PURGE AIR ALARM.
Condition: Unknown
Due 3 November 1993
Resolved 3 November 1993
Fire Fighting
Issued 14 January 1992 Resolved
PROVE PROPER OPERATION OF TIME DELAY FOR FIXED HALON SYSTEM IN WATER MAKER ROOM._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 14 February 1992
Resolved 24 January 1992
Fire Fighting
Issued 14 January 1992 Resolved
INSTALL SIGNS STATING "WHEN SIREN SOUNDS VACATE SPACE AT ONCE HALON BEING RELEASED" IN BOTH WATER MAKER ROOM AND SCR ROOM.
Condition: Unknown
Due 14 January 1992
Resolved 14 January 1992
Documentation
Issued 29 August 1991 Resolved
Revise operating manual to (1) reflect the actual installation of the fixedhalon system controls and bottles in the SCR Room and Water Maker Room, and(2) provide a description of the bilge system operation.
Condition: Unknown
Due 29 August 1991
Resolved 29 August 1991
Fire Fighting
Issued 29 August 1991 Resolved
Provide time delays and pre-discharge warning alarms for fixed halon systems.
Condition: Unknown
Due 29 August 1991
Resolved 29 August 1991
Electrical
Issued 29 August 1991 Resolved
Repair "Loss of Purge Air" audible alarm on stroke counter on Drill Floor.
Condition: Unknown
Due 29 August 1991
Resolved 29 August 1991
Fire Fighting
Issued 29 August 1991 Resolved
Provide an additional pull station for SCR Room Halon System outside of theWater Maker Room._x001C_ _x001C_
Condition: Unknown
Due 29 August 1991
Resolved 29 August 1991
Fire Fighting
Issued 29 August 1991 Resolved
Replace CO2 Portable Extinguisher Bottle Bracket and Horn Clip for Station 46 on Shale Shaker floor.
Condition: Unknown
Due 29 August 1991
Resolved 29 August 1991
Electrical
Issued 29 August 1991 Resolved
Repair and demonstrate proper operation of remote shutdown of No. 2 Main Generator.
Condition: Unknown
Due 29 August 1991
Resolved 29 August 1991
Electrical
Issued 29 August 1991 Resolved
Remove "E" light designation from light fixtures in SCR Rom and above drillwater pumps that are not on emergency circuits.
Condition: Unknown
Due 29 August 1991
Resolved 29 August 1991
Electrical
Issued 29 August 1991 Resolved
Remove ground in Air Conditioning circuit._x001C_
Condition: Unknown
Due 29 August 1991
Resolved 29 August 1991
Engineering
Issued 29 August 1991 Resolved
Provide fuel transfer documents to designate person in charge, hose manufacture date and burst rating.
Condition: Unknown
Due 29 August 1991
Resolved 29 August 1991
Electrical
Issued 29 August 1991 Resolved
Repair and demonstrate proper operation of Emergency Generator Alarms and Shutdown Control System.
Condition: Unknown
Due 29 August 1991
Resolved 29 August 1991
Engineering
Issued 29 August 1991 Resolved
Conduct and record 150% MAWP hydrostatic test of fuel transfer hose.
Condition: Unknown
Due 29 August 1991
Resolved 29 August 1991
Engineering
Issued 29 August 1991 Resolved
Mark fuel oil transfer hose for its service and maximum allowable working pressure.
Condition: Unknown
Due 29 August 1991
Resolved 29 August 1991
Fire Fighting
Issued 29 August 1991 Resolved
Renew bracket for fire extinguisher in Lifeboat No. 1.
Condition: Unknown
Due 29 August 1991
Resolved 29 August 1991
Engineering
Issued 29 August 1991 Resolved
Label remote fuel oil shutdown valves for emergency generator.
Condition: Unknown
Due 29 August 1991
Resolved 29 August 1991
Fire Fighting
Issued 29 August 1991 Resolved
Refill B-V Dry chemical extinguisher on port side of helicopter deck.
Condition: Unknown
Due 29 August 1991
Resolved 29 August 1991
Fire Fighting
Issued 29 August 1991 Resolved
Renew cracked fitting on hose between nitrogen bottle and dry chemical container on B-V extinguisher on port side of helicopter deck.
Condition: Unknown
Due 29 August 1991
Resolved 29 August 1991
Lifesaving
Issued 29 August 1991 Resolved
Renew EPIRB Battery.
Condition: Unknown
Due 29 August 1991
Resolved 29 August 1991
Lifesaving
Issued 29 August 1991 Resolved
Repair reset switch for winch motor controller for Lifeboat #2.
Condition: Unknown
Due 29 August 1991
Resolved 29 August 1991
Lifesaving
Issued 29 August 1991 Resolved
Provide required amounts of water, condensed milk, and provisions for both lifeboats.
Condition: Unknown
Due 29 August 1991
Resolved 29 August 1991
Unknown
Issued 29 August 1991 Resolved
Provide non-skid surface to helicopter deck.
Condition: Unknown
Due 29 August 1991
Resolved 29 August 1991
Unknown
Issued 29 August 1991 Resolved
Make peripheral lighting on helicopter deck 10 feet apart.
Condition: Unknown
Due 29 August 1991
Resolved 29 August 1991
Lifesaving
Issued 29 August 1991 Resolved
Provide onboard a "rocket-type" line throwing apparatus.
Condition: Unknown
Due 29 August 1991
Resolved 29 August 1991
Deck/Cargo
Issued 29 August 1991 Resolved
Provide hand signal sharts for cranes.
Condition: Unknown
Due 29 August 1991
Resolved 29 August 1991
Deck/Cargo
Issued 29 August 1991 Resolved
Replace cracked glass in crane cabs.
Condition: Unknown
Due 29 August 1991
Resolved 29 August 1991
Lifesaving
Issued 29 August 1991 Resolved
Repair interior lighting in Lifeboat #1.
Condition: Unknown
Due 29 August 1991
Resolved 29 August 1991
Lifesaving
Issued 29 August 1991 Resolved
Repair/replace light for ring buoy at starboard aft station under drill floor.
Condition: Unknown
Due 29 August 1991
Resolved 29 August 1991
Unknown
Issued 29 August 1991 Resolved
Install schrader-type valve for air cushion line to freshwater pressure tanks.
Condition: Unknown
Due 29 August 1991
Resolved 29 August 1991
Electrical
Issued 29 August 1991 Resolved
Repair and demonstrate proper operation of low lube oil pressure shutdown and alarm for No. 3 Main Generator.
Condition: Unknown
Due 29 August 1991
Resolved 29 August 1991
Construction/Loadline
Issued 2 September 1987 Resolved
CONDUCT A N.D.T. OF THE BOW LEG PIN HOLE REPAIR.
Condition: Unknown
Due 2 September 1987
Resolved 2 September 1987
Fire Fighting
Issued 2 September 1987 Resolved
COMPLETE INSTALLATION AND TEST THE OPERATION OF THE FIRESTATION ON THE PORTSIDE, AFT HELOPORT.
Condition: Unknown
Due 2 September 1987
Resolved 2 September 1987
Lifesaving
Issued 2 September 1987 Resolved
CONDUCT OPERATIONAL TEST OF THE DISENGAGING APPARATUS ON BOTH LIFEBOATS.
Condition: Unknown
Due 2 September 1987
Resolved 2 September 1987
Accommodation/Occupational Safety
Issued 2 September 1987 Resolved
COMPLETE INSTALLATION AND TEST THE OPERATON OF THE NEW MARINE SANITATION DEVICE.
Condition: Unknown
Due 2 September 1987
Resolved 2 September 1987
Construction/Loadline
Issued 9 April 1984 Resolved
PROVIDE CONTAINMENT FOR FUEL OIL TRANSFER STATIONS AND FUEL VENTS.
Condition: Unknown
Due 20 April 1984
Resolved 9 April 1984
Accommodation/Occupational Safety
Issued 9 April 1984 Resolved
PROVIDE SUITABLE RELIEF DEVICE FOR #2 POTABLE WATER TANK.
Condition: Unknown
Due 20 April 1984
Resolved 9 April 1984
Navigation
Issued 9 April 1984 Resolved
PROVIDE NOT-UNDER-COMMAND-LIGHTS AND APPROPRIATE DAY SHAPES.
Condition: Unknown
Due 20 April 1984
Resolved 9 April 1984
Construction/Loadline
Issued 9 April 1984 Resolved
INSTALL STAIR TOWER DOORS AND ENCLOSE STAIRWAYS BETWEEN ACCOMODATION LEVELSIN QUARTERS.
Condition: Unknown
Due 20 July 1984
Resolved 9 April 1984
Unknown
Issued 9 April 1984 Resolved
PROVIDE ON BOARD AN APPROVED OPERATIONS MANUAL PRIOR TO NEXT VESSEL MOVEMENT.
Condition: Unknown
Due 20 July 1984
Resolved 9 April 1984
Electrical
Issued 9 April 1984 Resolved
PROVIDE SUITABLE BATTERY BOX FOR THE EMERGENCY GENERATOR START BATTERIES.
Condition: Unknown
Due 20 April 1984
Resolved 9 April 1984
Lifesaving
Issued 9 April 1984 Resolved
PROVIDE AN AUXILIARY LINE FOR THE LINE THROWING APPARATUS.
Condition: Unknown
Due 20 April 1984
Resolved 9 April 1984

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.