Inspection record

Last inspected 11 March 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDG0971
228973
Flag
UNITED STATES
Maury page id
psix-228973

Documentation record

Registered dimensions (L × B × D)41.5 ft × 15.1 ft × 3.5 ft
Registered tonnagegross 38 / net 30
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCHRIS-CRAFT CORPORATION · HOLLAND, MI, UNITED STATES · built 1967
Hull materialSteel
PropulsionDiesel Direct
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portALGONAC, MI
Endorsements, as the file codes themcw_un, rec, reg
DocumentationValid · issued 31 March 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it38 - Simplified, Gross Ton
30 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 17 inspections, each with its date, unit and type; 25 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 17

11 March 2026 Internal Structural Exam · Drydock Exam
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 8324322
29 July 2025 Annual Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 8197441
25 November 2024 Deficiency Check
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 8039571
26 June 2024 Annual Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7938647
2 August 2023 Annual Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7758484
3 August 2022 Deficiency Check · COI Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7523809
11 August 2021 Deficiency Check · Annual Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7283326
22 January 2021 Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7128742
5 August 2020 Annual Inspection · Deficiency Check · Exemption
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7024459
23 July 2019 Deficiency Check · Annual Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6689408
28 June 2018 Deficiency Check
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6458094
24 May 2018 Deficiency Check · Annual Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6416838
8 November 2017 Administrative Inspection
Administrative · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6303245
18 August 2017 Deficiency Check
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6244669
15 May 2017 COI Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 6148104
20 July 2016 Annual Inspection
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 5947933
22 March 2016 Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 5839120

Deficiency record · 25

05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 26 June 2024 Resolved
Station license required for operation of all maritime services transmitting equipment on board a vessel. Provided ship station license.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 July 2024
Resolved 25 November 2024
Resolution: Received copy of FCC document.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 26 June 2024 Resolved
Vessel shall keep a passenger count ashore for each voyage. Currently the count is being kept on board the vessel. Corrected on the spot.
Action required: 10 - Deficiency Rectified
Due 26 June 2024
Resolved 26 June 2024
Resolution: Corrected on the spot
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 3 August 2022 Resolved
All vessels must undergo an inspection for certification as specified in 176.404. COI expired 17MAY22. Vessel has been operated since that date with an expired COI.
Action required: 10 - Deficiency Rectified
Resolved 3 August 2022
Resolution: Vessel underwent COI renewal inspection.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 3 August 2022 Resolved
Fire and MOB drills shall be logged with date and general description of scenario. Drills were logged but only with the date. 46 CFR 185.520
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 September 2022
Resolved 31 August 2022
Resolution: Recieved photo via email of updated logs, however still room for improvement. Sent feedback outlining what should be logged.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 3 August 2022 Resolved
Ensure correct MMSI number is loaded into the VHF radio 46 CFR 184.520
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 September 2022
Resolved 31 August 2022
Resolution: Correct MMSI number is now loaded into the radio
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 3 August 2022 Resolved
Ring lifebuoy light battery is expired. Replace floating waterlight must be approved under 161.010 46 CFR 180.70(d)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 September 2022
Resolved 31 August 2022
Resolution: Received photo of correctly installed floating water light.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 3 August 2022 Resolved
Rudder post is leaking. Secure leak 46 CFR 184.814
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 September 2022
Resolved 31 August 2022
Resolution: Owner stated he tightened the packing.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 11 August 2021 Resolved
Abandon ship and man overboard drills shall be logged for review by the Coast Guard and shall include date and general description.
Action required: 10 - Deficiency Rectified
Resolved 11 August 2021
Resolution: Vessel owner logged the drill completed during the inspection.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 11 August 2021 Resolved
Firefighting drills and training shall be logged to include date and description of scenario
Action required: 10 - Deficiency Rectified
Resolved 11 August 2021
Resolution: Owner logged drills conducted during the annual inspection
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 11 August 2021 Resolved
Where a flexible fill pipe section is necessary, where flexible section is a non-conductor of electricity, the metallic sections shall be joined by a conductor for protection against static spark. No bonding strap was found on the flexible fuel fill line.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 September 2021
Resolved 16 September 2021
Resolution: Email provided including pictures of pipe with bonding strap.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 22 January 2021 Resolved
DETERMINE PROPER SECURING CONFIGURATION FOR PROPELLER IAW GOOD MARINE PRACTICE AND MANUFACTURERS GUIDELINES.
Action required: 705 - Other - as specified
Resolved 30 March 2021
Resolution: Previously installed castle nut arrangement for prop has been removed and replaced with a new shaft, propeller, and double nut arrangement for propeller.
04 - Emergency Systems › N/A - No Subsystem › Means of communication between safety centre and other control stations
Issued 5 August 2020 Resolved
Ferries operating on short runs may substitute signs for the announcement required in paragraphs (a) and (b). Required announcement: the location of emergency exits and ring life buoys, the stowage location of lifejackets, and that all passengers will be required to don life jackets as directed by the master.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 September 2020
Resolved 23 September 2020
Resolution: Signs describing the emergency exits and PFD stowage locations were posted.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 August 2020 Resolved
An adult lifejacket must be provided for each person carried on board. 50 lifejackets are on board, the vessel is certificated for 51. Update signage as necessary.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 September 2020
Resolved 2 October 2020
Resolution: Corrected sign on door to 51
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 5 August 2020 Resolved
Each battery used in lifesaving equipment must be replaced during the annual inspection if the expiration date of the battery has passed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 September 2020
Resolved 23 September 2020
Resolution: battery has been replaced
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 5 August 2020 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up to date charts of large enough scale to make safe navigation possible.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 September 2020
Resolved 14 December 2020
Resolution: Vessel has been granted a special consideration for the carraige of charts. Notated on COI and letter scanned into documents.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 5 August 2020 Resolved
Stored pressure fire extinguishers require an internal inspection at 6 year intervals, and a hydrostatic test at 12 year intervals. Both fire extinguishers on board are overdue for either test as indicated by the collar stamped May 2014. Determine test needed and perform as necessary by a certified person.NFPA 10 7.3.1.2.1; 7.3.3.2; 8.1.1
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 September 2020
Resolved 2 October 2020
Resolution: Hydro test done on out of date fire extinguisher, collar ring properly stamped on other fire extinguisher
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - intoxication
Issued 5 August 2020 Resolved
Each EAP education program must include at least the following elements: display and distribution of a community service hot line telephone number for crew member assistance, and employer's policy regarding drug and alcohol use in the workplace.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 September 2020
Resolved 23 September 2020
Resolution: EAP information and hot line number has been posted in the operating station.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 July 2019 Resolved
A vessel must have a ring life buoy. Life buoy on board needs to be replaced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 July 2019
Resolved 30 July 2019
Resolution: Recieved proof of purchase and photo of new lifebuoy via email from vessel owner.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 23 July 2019 Resolved
The master of a vessel shall keep a correct written count of all passengers; which must be communicated and available.
Action required: 705 - Other - as specified
Due 30 July 2019
Resolved 30 July 2019
Resolution: recieved email from owner with proof of purchase and signs put in place at the dock containing the date and passenger count.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 24 May 2018 Resolved
Provide current FCC Great Lakes Agreement.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 June 2018
Resolved 28 June 2018
Resolution: Received documentation that the annual inspection has been completed.
Personnel › Certificates/Documents/Licenses › License, Operator
Issued 15 May 2017 Resolved
Vessel operator needs a FCC radio operator permit. 47CFR13.5
Action required: 705 - Other - as specified
Due 15 July 2018
Resolved 24 May 2018
Resolution: Examined Marine Operators Permit.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 15 May 2017 Resolved
Update first aid kit.
Action required: 705 - Other - as specified
Due 22 May 2017
Resolved 18 August 2017
Resolution: All items within first aid kit updated.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 15 May 2017 Resolved
Replace ring life buoy and life line with servicable replacement.
Action required: 705 - Other - as specified
Due 22 May 2017
Resolved 18 August 2017
Resolution: Buoyant lifeline and throw bag installed.
Electrical › Electric Supply System (service) › Cable
Issued 20 July 2016 Resolved
Positive cable to solenoid loose at solenoid terminal. Tighten/repair connection.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 July 2016
Resolved 20 July 2016
Resolution: Terminal tightened.
Engineering › Fuel Oil Service System › Pump
Issued 20 July 2016 Resolved
Fuel oil throttle cable attached to regulator with a rivet. Remove rivet and repair as original.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 July 2016
Resolved 20 July 2016
Resolution: Proper cotter pin installed.