MERRIMACK QUEEN is a 1983 passenger barge (inspected). The Coast Guard has recorded 23 inspections since 1984, most recently in May 1997, along with 31 deficiencies.

Records from 1984 to 1997. Most recent: inspection, 15 May 1997.

Built
1983
Last inspected
15 May 1997
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WTX8407
228976
Flag
UNITED STATES
—
Maury page id
psix-228976

Inspections, by type

…with no type recorded6
Years with a record 14 calendar years (1984–1997)
The 23 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 29 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Documentation record

Registered dimensions (L × B × D)69.3 ft × 24.1 ft × 5.7 ft
Registered tonnagegross 80 / net 80
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderRED FOX INDUSTRIES, INC. · NEW IBERIA LA, UNITED STATES · built 1983
Hull materialSteel
PropulsionCombination Types
Hull shapeBox
Hull configurationMonohull
Hailing portBOSTON, MA
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger Barge (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it80 - Simplified, Net Ton
80 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 23

15 May 1997 Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1105443
10 March 1997 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1104582
14 June 1996 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1078367
2 June 1995 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1187205
31 May 1994 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1330036
23 May 1994 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1330032
21 June 1993 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 41602
3 June 1993 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1138815
20 May 1993 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 836607
5 May 1992 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 951870
25 April 1991 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 910903
5 April 1991 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 930926
27 July 1990 Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 928058
17 July 1990 Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 905866
9 May 1990 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1224658
19 May 1989 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1207632
26 May 1988 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1199708
12 April 1988 Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1040653
1 June 1987 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1007424
10 June 1986 COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 990070
1 May 1986 Credit Drydock
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1000160
29 May 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1287839
24 February 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 974118

Deficiency record · 31

Lifesaving
Issued 14 June 1996 Resolved
CONDUCT EMERGENCY UNDERWAY DRILLS TO THE SATISFACTION OF AN ATTENDING COASTGUARD MARINE INSPECTOR.
Condition: Unknown
Due 14 June 1996
Resolved 20 June 1996
Construction/Loadline
Issued 14 June 1996 Resolved
PROVE PROPER OPERATION OF BOTH ENGINE ROOM ELECTRIC BILGE PUMPS.
Condition: Unknown
Due 14 June 1996
Resolved 20 June 1996
Construction/Loadline
Issued 14 June 1996 Resolved
PROVE PROPER OPERATION OF THE AFT VOID ELECTRIC BILGE PUMP.
Condition: Unknown
Due 14 June 1996
Resolved 20 June 1996
Documentation
Issued 14 June 1996 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 28 June 1996
Resolved 26 June 1996
Accommodation/Occupational Safety
Issued 14 June 1996 Resolved
MAKE AIR RECEIVER AVAILABLE FOR INTERNAL/HYDRO EXAM.
Condition: Unknown
Due 14 June 1996
Resolved 20 June 1996
Electrical
Issued 14 June 1996 Resolved
PROVIDE SUITABLE ELECTRICAL MATTING RATED FOR THE MAIN DISTRIBUTION BOARD.
Condition: Unknown
Due 14 June 1996
Resolved 20 June 1996
Electrical
Issued 14 June 1996 Resolved
PROPERLY DEAD END ALL LOOSE WIRES, REMOVE WIRE NUTS AND PROPERLY CONNECT ALL ELECTRICAL CONNECTIONS UNDER THE WHEELHOUSE CONSOLE.
Condition: Unknown
Due 14 June 1996
Resolved 20 June 1996
Construction/Loadline
Issued 14 June 1996 Resolved
PLACE FRESH WATER BALLAST ABOARD AS REQUIRED BY THE VESSEL'S STABILITY LETTER.
Condition: Unknown
Due 14 June 1996
Resolved 20 June 1996
Documentation
Issued 14 June 1996 Resolved
PROVIDE VALID CERTIFICATE OF DOCUMENTATION.
Condition: Unknown
Due 14 June 1996
Resolved 20 June 1996
Documentation
Issued 14 June 1996 Resolved
PROVIDE AND PROPERLY POST VESSEL STABILITY LETTER.
Condition: Unknown
Due 14 June 1996
Resolved 20 June 1996
Documentation
Issued 14 June 1996 Resolved
PROVIDE AND PROPERLY POST A VALID FCC STATION LICENSE.
Condition: Unknown
Due 14 June 1996
Resolved 20 June 1996
Lifesaving
Issued 14 June 1996 Resolved
PROVIDE CURRENT DISTRESS SIGNALS AND PROPER CONTAINER.
Condition: Unknown
Due 14 July 1996
Resolved 20 June 1996
Fire Fighting
Issued 14 June 1996 Resolved
REMOVE THE NON-CG APPROVED HALON EXTINGUISHER FROM THE WHEELHOUSE AND REPLACE WITH AN APPROVED BI EXTINGUISHER.
Condition: Unknown
Due 14 June 1996
Resolved 20 June 1996
Construction/Loadline
Issued 14 June 1996 Resolved
PROVIDE DRAFT MARKS FOR THE STERN OF THE VESSEL.
Condition: Unknown
Due 14 June 1996
Resolved 20 June 1996
Fire Fighting
Issued 31 May 1994 Resolved
PROVIDE 5 GALLON PER MINUTE HAND FIRE PUMP.
Condition: Unknown
Due 17 June 1994
Resolved 23 June 1994
Accommodation/Occupational Safety
Issued 31 May 1994 Resolved
PROVE PROPER OPERATION OF AIR RECEIVER RELIEF VALVE.
Condition: Unknown
Due 17 June 1994
Resolved 23 June 1994
Fire Fighting
Issued 31 May 1994 Resolved
REPAIR AND PROVE PROPER OPERATION OF FIXED FIRE MAIN. UNTIL SUCH TIME VESSEL IS TO BE EQUIPPED WITH INSTALLED 9 BII PORTABLE EXTINGUISHERS AND PORTABLE FIRE PUMP.
Condition: Unknown
Due 17 June 1994
Resolved 23 June 1994
Documentation
Issued 20 May 1993 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 20 June 1993
Resolved 1 July 1993
Lifesaving
Issued 20 May 1993 Resolved
INSTALL A LABEL PLATE LEADING TO THE UPPER DECK WITH THE MAXIMUM NUMBER OF PASSENGERS ALLOWED ON THE UPPER DECK AS PER THE VESSEL'S STABILITY LETTER.
Condition: Unknown
Due 3 June 1993
Resolved 11 June 1993
Engineering
Issued 10 June 1986 Resolved
FABRICATE A REMOTE FUEL SHUT-OFF FOR FUEL TANK.
Condition: Unknown
Due 10 June 1986
Resolved 10 June 1986
Documentation
Issued 10 June 1986 Resolved
CONTACT FCC TO GET RADIO STATION LICENSE.
Condition: Unknown
Due 10 June 1986
Resolved 10 June 1986
Navigation
Issued 10 June 1986 Resolved
TEST AIR PRESSURE TANK RELIEF VALVE.
Condition: Unknown
Due 10 June 1986
Resolved 10 June 1986
Documentation
Issued 10 June 1986 Resolved
SUBMIT NEW STABILTY DATA FOR SPONSON ADDITION.
Condition: Unknown
Due 10 June 1986
Resolved 10 June 1986
Electrical
Issued 10 June 1986 Resolved
MAKE EMERGENCY GENERATOR OPERABLE.
Condition: Unknown
Due 10 June 1986
Resolved 10 June 1986
Construction/Loadline
Issued 10 June 1986 Resolved
PROVIDE BILGE SUCTION TO PORT AND STARBOARD SPONSONS.
Condition: Unknown
Due 10 June 1986
Resolved 10 June 1986
Lifesaving
Issued 10 June 1986 Resolved
PROVIDE SEPERATE STOWAGE FOR CHILD LIFE PRESERVERS.
Condition: Unknown
Due 10 June 1986
Resolved 10 June 1986
Fire Fighting
Issued 10 June 1986 Resolved
PROVIDE A SPANNER WRENCH AT EACH FIRE STATION.
Condition: Unknown
Due 10 June 1986
Resolved 10 June 1986
Electrical
Issued 24 February 1984 Resolved
PROVIDE APPROVED DRAWINGS FOR ELECTRICAL AND HYDRAULIC INSTALLATION.
Condition: Unknown
Due 24 February 1984
Resolved 24 February 1984
Construction/Loadline
Issued 24 February 1984 Resolved
(CONT. FROM 1) RESTRICTIONS.
Condition: Unknown
Due 24 February 1984
Resolved 24 February 1984
Construction/Loadline
Issued 24 February 1984 Resolved
PROVIDE PLACARDS AT FILLER AREAS FOR FORWARD VOIDS PORT AND STARBOARD #1A BALLAST PORT AND STARBOARD, FUEL OIL TANK AND PORTABLE WATER TANK GIVING
Condition: Unknown
Due 24 February 1984
Resolved 24 February 1984
Unknown
Issued 24 February 1984 Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE M/V TECHE QUEEN, O.N. DN664922.
Condition: Unknown
Due 24 February 1984
Resolved 24 February 1984

Ownership record