Inspection history · 23
15 May 1997
Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1105443
10 March 1997
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1104582
14 June 1996
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1078367
2 June 1995
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1187205
31 May 1994
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1330036
23 May 1994
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1330032
21 June 1993
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 41602
3 June 1993
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1138815
20 May 1993
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 836607
5 May 1992
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 951870
25 April 1991
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 910903
5 April 1991
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 930926
27 July 1990
Administrative
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 928058
17 July 1990
Type not recorded
No type recorded · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 905866
9 May 1990
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1224658
19 May 1989
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1207632
26 May 1988
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1199708
12 April 1988
Hull Examination
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1040653
1 June 1987
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1007424
10 June 1986
COI Inspection
Physical examination · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 990070
1 May 1986
Credit Drydock
Administrative · MSO BOSTON · USCG Northeast District (CGD-NE) · Activity 1000160
29 May 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1287839
24 February 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 974118
Lifesaving
Issued 14 June 1996
Resolved
CONDUCT EMERGENCY UNDERWAY DRILLS TO THE SATISFACTION OF AN ATTENDING COASTGUARD MARINE INSPECTOR.
Condition: Unknown
Due 14 June 1996
Resolved 20 June 1996
Construction/Loadline
Issued 14 June 1996
Resolved
PROVE PROPER OPERATION OF BOTH ENGINE ROOM ELECTRIC BILGE PUMPS.
Condition: Unknown
Due 14 June 1996
Resolved 20 June 1996
Construction/Loadline
Issued 14 June 1996
Resolved
PROVE PROPER OPERATION OF THE AFT VOID ELECTRIC BILGE PUMP.
Condition: Unknown
Due 14 June 1996
Resolved 20 June 1996
Documentation
Issued 14 June 1996
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 28 June 1996
Resolved 26 June 1996
Accommodation/Occupational Safety
Issued 14 June 1996
Resolved
MAKE AIR RECEIVER AVAILABLE FOR INTERNAL/HYDRO EXAM.
Condition: Unknown
Due 14 June 1996
Resolved 20 June 1996
Electrical
Issued 14 June 1996
Resolved
PROVIDE SUITABLE ELECTRICAL MATTING RATED FOR THE MAIN DISTRIBUTION BOARD.
Condition: Unknown
Due 14 June 1996
Resolved 20 June 1996
Electrical
Issued 14 June 1996
Resolved
PROPERLY DEAD END ALL LOOSE WIRES, REMOVE WIRE NUTS AND PROPERLY CONNECT ALL ELECTRICAL CONNECTIONS UNDER THE WHEELHOUSE CONSOLE.
Condition: Unknown
Due 14 June 1996
Resolved 20 June 1996
Construction/Loadline
Issued 14 June 1996
Resolved
PLACE FRESH WATER BALLAST ABOARD AS REQUIRED BY THE VESSEL'S STABILITY LETTER.
Condition: Unknown
Due 14 June 1996
Resolved 20 June 1996
Documentation
Issued 14 June 1996
Resolved
PROVIDE VALID CERTIFICATE OF DOCUMENTATION.
Condition: Unknown
Due 14 June 1996
Resolved 20 June 1996
Documentation
Issued 14 June 1996
Resolved
PROVIDE AND PROPERLY POST VESSEL STABILITY LETTER.
Condition: Unknown
Due 14 June 1996
Resolved 20 June 1996
Documentation
Issued 14 June 1996
Resolved
PROVIDE AND PROPERLY POST A VALID FCC STATION LICENSE.
Condition: Unknown
Due 14 June 1996
Resolved 20 June 1996
Lifesaving
Issued 14 June 1996
Resolved
PROVIDE CURRENT DISTRESS SIGNALS AND PROPER CONTAINER.
Condition: Unknown
Due 14 July 1996
Resolved 20 June 1996
Fire Fighting
Issued 14 June 1996
Resolved
REMOVE THE NON-CG APPROVED HALON EXTINGUISHER FROM THE WHEELHOUSE AND REPLACE WITH AN APPROVED BI EXTINGUISHER.
Condition: Unknown
Due 14 June 1996
Resolved 20 June 1996
Construction/Loadline
Issued 14 June 1996
Resolved
PROVIDE DRAFT MARKS FOR THE STERN OF THE VESSEL.
Condition: Unknown
Due 14 June 1996
Resolved 20 June 1996
Fire Fighting
Issued 31 May 1994
Resolved
PROVIDE 5 GALLON PER MINUTE HAND FIRE PUMP.
Condition: Unknown
Due 17 June 1994
Resolved 23 June 1994
Accommodation/Occupational Safety
Issued 31 May 1994
Resolved
PROVE PROPER OPERATION OF AIR RECEIVER RELIEF VALVE.
Condition: Unknown
Due 17 June 1994
Resolved 23 June 1994
Fire Fighting
Issued 31 May 1994
Resolved
REPAIR AND PROVE PROPER OPERATION OF FIXED FIRE MAIN. UNTIL SUCH TIME VESSEL IS TO BE EQUIPPED WITH INSTALLED 9 BII PORTABLE EXTINGUISHERS AND PORTABLE FIRE PUMP.
Condition: Unknown
Due 17 June 1994
Resolved 23 June 1994
Documentation
Issued 20 May 1993
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 20 June 1993
Resolved 1 July 1993
Lifesaving
Issued 20 May 1993
Resolved
INSTALL A LABEL PLATE LEADING TO THE UPPER DECK WITH THE MAXIMUM NUMBER OF PASSENGERS ALLOWED ON THE UPPER DECK AS PER THE VESSEL'S STABILITY LETTER.
Condition: Unknown
Due 3 June 1993
Resolved 11 June 1993
Engineering
Issued 10 June 1986
Resolved
FABRICATE A REMOTE FUEL SHUT-OFF FOR FUEL TANK.
Condition: Unknown
Due 10 June 1986
Resolved 10 June 1986
Documentation
Issued 10 June 1986
Resolved
CONTACT FCC TO GET RADIO STATION LICENSE.
Condition: Unknown
Due 10 June 1986
Resolved 10 June 1986
Navigation
Issued 10 June 1986
Resolved
TEST AIR PRESSURE TANK RELIEF VALVE.
Condition: Unknown
Due 10 June 1986
Resolved 10 June 1986
Documentation
Issued 10 June 1986
Resolved
SUBMIT NEW STABILTY DATA FOR SPONSON ADDITION.
Condition: Unknown
Due 10 June 1986
Resolved 10 June 1986
Electrical
Issued 10 June 1986
Resolved
MAKE EMERGENCY GENERATOR OPERABLE.
Condition: Unknown
Due 10 June 1986
Resolved 10 June 1986
Construction/Loadline
Issued 10 June 1986
Resolved
PROVIDE BILGE SUCTION TO PORT AND STARBOARD SPONSONS.
Condition: Unknown
Due 10 June 1986
Resolved 10 June 1986
Lifesaving
Issued 10 June 1986
Resolved
PROVIDE SEPERATE STOWAGE FOR CHILD LIFE PRESERVERS.
Condition: Unknown
Due 10 June 1986
Resolved 10 June 1986
Fire Fighting
Issued 10 June 1986
Resolved
PROVIDE A SPANNER WRENCH AT EACH FIRE STATION.
Condition: Unknown
Due 10 June 1986
Resolved 10 June 1986
Electrical
Issued 24 February 1984
Resolved
PROVIDE APPROVED DRAWINGS FOR ELECTRICAL AND HYDRAULIC INSTALLATION.
Condition: Unknown
Due 24 February 1984
Resolved 24 February 1984
Construction/Loadline
Issued 24 February 1984
Resolved
(CONT. FROM 1) RESTRICTIONS.
Condition: Unknown
Due 24 February 1984
Resolved 24 February 1984
Construction/Loadline
Issued 24 February 1984
Resolved
PROVIDE PLACARDS AT FILLER AREAS FOR FORWARD VOIDS PORT AND STARBOARD #1A BALLAST PORT AND STARBOARD, FUEL OIL TANK AND PORTABLE WATER TANK GIVING
Condition: Unknown
Due 24 February 1984
Resolved 24 February 1984
Unknown
Issued 24 February 1984
Resolved
THE FOLLOWING DEFICIENCIES PERTAIN TO THE M/V TECHE QUEEN, O.N. DN664922.
Condition: Unknown
Due 24 February 1984
Resolved 24 February 1984