Records from 2008 to 2026. Most recent: inspection, 20 January 2026.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 23 January 2025
Resolved
A vessel not required to have a power driven fire pump by § 181.300 must have at least three 9.5 liter (2 1/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket.
Provide proof of 1 additional fire bucket.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 30 January 2025
Resolved 23 January 2025
Resolution: Vessel provided photo of new fire bucket.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 23 January 2025
Resolved
Marine employers shall establish programs for the chemical testing for dangerous drugs on a random basis of crewmembers on inspected vessels.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 February 2025
Resolved 28 January 2025
Resolution: Vessel sent program contents to [name withheld].
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 23 January 2025
Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 25 millimeters (1 inch) high indicating purpose of the valve and direction of operation.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 February 2025
Resolved 28 January 2025
Resolution: Vessel installed stickers to identify fuel shut of vavlves.
01 - Certificates & Documentation › 011 - Ships Certificates › Pollution Prevention by Noxious Liquid Sub in Bulk
Issued 23 January 2025
Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets and immersion suits. Identification of the items may be in words, or the appropriate symbols in IMO Resolution A.760(18) (incorporated by reference; see 46 CFR 175.600). Letters and numbers must be at least 50 millimeters (2 inches) high. Symbols must be at least 100 mm (4 inches) square.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 February 2025
Resolved 28 January 2025
Resolution: Labeling installed on seating.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 23 January 2025
Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 February 2025
Resolved 28 January 2025
Resolution: Divider installed to separate child and adults.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 28 January 2022
Resolved
All vessels shall be provided with an approved adult type life preserver for each person carried. Each life preserver carried on a vessel must have at least 200 sq. cm of retro-reflective material on each side...Provide photos of 01 new life preserver and new SOLAS retro-reflective material installed.
46 CFR 180.25-5/180.25-25
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 February 2022
Resolved 3 February 2022
Resolution: Capt sent pictures of lifejackets with retro-reflective tape.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 28 January 2022
Resolved
Where rigid nonmetallic material is permitted for use in piping systems by this subpart, the following restrictions shall be adhered to: Each such penetration (of watertight decks and bulkheads) is accomplished using an acceptable metallic fitting, welded or otherwise attached to the bulkhead or deck by an accepted method...Provide evidence that various bulkhead penetrations are secured via appropriate fittings.
46 CFR 182.40-1
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 February 2022
Resolution: Captain sent pictures of satisfactory bulkhead penetration installation.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 28 January 2022
Resolved
All wiring shall be run as high as practicable above bilges... provide photos that wiring handing in bilge areas are clamped as high off the deck as practicable.
183.05-50(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 February 2022
Resolved 28 February 2022
Resolution: Captain sent pictures of satisfactory wire installation.
05 - Radio Communications › N/A - No Subsystem › Other (radio communication)
Issued 28 January 2022
Resolved
A proper certificate issued by the Federal Communications Commission shall be regarded as evidence that the radio installation is in compliance...Issued radio certificate is expired.
184.25-1(b)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 February 2022
Resolution: Received FCC certificate.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 28 January 2022
Resolved
An inspection for renewal of a certificate of inspection shall...be such to ensure that the vessel, as regards to the structure...is in satisfactory condition and fit for the service for which it is intended...Wood cross members/support structure in the engine room are rotting. Replace wood supports in deteriorated areas and provide evidence of changes.
176.05-10(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 February 2022
Resolved 28 February 2022
Resolution: Captain sent pictures of satisfactory structural member installation.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 11 January 2022
Resolved
Multiple areas of the hull have blisters or soft spots. All marked areas to be ground down to find extent of damage and repairs to be made prior to credit dry-dock. 46 CFR 176.610
Action required: 705 - Other - as specified
Resolved 26 January 2022
Resolution: Repairs completed SAT.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 11 January 2022
Resolved
Small section of core in the keel has rotted. Provide repair proposal and make repairs prior to credit dry-dock.
46 CFR 176.610
Action required: 705 - Other - as specified
Resolved 26 January 2022
Resolution: Repair completed SAT.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 11 January 2022
Resolved
De-lamination found in the port and stbd fiberglass tabs in the fwd compt and a hole found at the top stbd section of the collision bulkhead. Make repairs prior to credit dry-dock.
46 CFR 176.610
Action required: 705 - Other - as specified
Resolved 26 January 2022
Resolution: Repairs completed SAT.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 11 January 2022
Resolved
Lazerette watertight hatch frame cracked through the frame causing complete separation. Repair/replace frame prior to credit dry-dock. 46 CFR 179.360
Action required: 705 - Other - as specified
Resolved 26 January 2022
Resolution: Frame repaired SAT.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 11 January 2022
Resolved
Deck rails and center rail found loose due to separated and unsecure mounting. Secure all rails prior to credit dry-dock.
46 CFR 177.900
Action required: 705 - Other - as specified
Resolved 26 January 2022
Resolution: Rails secured SAT.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 11 January 2022
Resolved
Lazerette hatch missing securing device. Install securing device prior to credit dry-dock. 46 CFR 179.360
Action required: 705 - Other - as specified
Resolved 26 January 2022
Resolution: Securing device installed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 11 January 2022
Resolved
Prove proper operation of propulsion engine suction through hull valve and head through hull valve prior to credit dry-dock. 46 CFR 176.610
Action required: 705 - Other - as specified
Resolved 21 January 2022
Resolution: Valves operate SAT.
14 - Pollution Prevention › 141 - MARPOL Annex I › Retention of oil on board
Issued 1 February 2021
Resolved
Clean oil from bilges.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 February 2021
Resolved 4 February 2021
Resolution: Vessel removed oil from bilges.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 February 2021
Resolved
Provide evidence of DAPI consortium enrollment and EAP training.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 February 2021
Resolved 4 February 2021
Resolution: Vessel provided evidence of DAPI consortium enrollment and EAP training.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 1 February 2021
Resolved
Obtain/renew ship station license.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 February 2021
Resolved 23 January 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 February 2021
Resolved
Replace retroreflective tape on all ID'd lifejackets.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 February 2021
Resolved 4 February 2021
Resolution: Vessel replaced retroreflective tape on all ID'd lifejackets.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 1 February 2021
Resolved
Replace 02 lifejackets. Passenger count reduced by 02 until replaced.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 February 2021
Resolved 4 February 2021
Resolution: Vessel replaced 02 lifejackets. Passenger count resumed to amount allowed on COI..
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 1 February 2021
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 February 2021
Resolved 4 February 2021
Resolution: EPIRB marked properly.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 1 February 2021
Resolved
Demonstrate pre-engineered fire extinguishing override.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 February 2021
Resolved 23 January 2025
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 1 February 2021
Resolved
Log fire drills and conduct regularly.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 February 2021
Resolved 4 February 2021
Resolution: Drill log provided.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 24 February 2020
Resolved
Prove proper operation of nav lights. restricted to daylight operations only until cleared.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 March 2020
Resolution: Nav lights working properly
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 February 2020
Resolved
Provide current DAPI crew list.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 24 March 2020
Resolution: Provided DAPI crew list.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 24 February 2020
Resolved
Provide 3 fire buckets.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 March 2020
Resolution: Provided 3 fire buckets
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 22 April 2019
Resolved
Provide 12 approved flares.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 April 2019
Resolution: Provided 12 approved hand flares.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 April 2019
Resolved
Provide 07 more Type I adult lifejackets prior to carrying more that 13 total persons.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 April 2019
Resolution: Provided 7 more approved type I's.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 22 April 2019
Resolved
Prove proper operation of bilge alarms.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 April 2019
Resolution: Proved proper operation of bilge alarms.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 22 April 2019
Resolved
Provide 3 fire buckets.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 April 2019
Resolution: Provided 03 fire buckets.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 April 2019
Resolved
Provide drug and alcohol program for inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 April 2019
Resolution: Provided drug and alcohol program for inspection.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 22 April 2019
Resolved
Prove proper operation of anchor light.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 April 2019
Resolution: Proved proper operation of anchor light.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 5 April 2018
Resolved
"OLD T" - 46CFR 176.25-25 - Service fixed and portable fire extinguishing systems.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 April 2018
Resolved 13 April 2018
Resolution: Verified servicing, cleared def.
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 8 December 2017
Resolved
Vessel hailing port not on stern of vessel.
Action required: 705 - Other - as specified
Due 22 December 2017
Resolved 16 January 2018
Resolution: Vessel hailing port and name placed on stern of vessel.
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 27 January 2017
Resolved
Renew retroflective tape on lifejackets.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 February 2017
Resolved 13 February 2017
Resolution: Vessel renewed retroflective tape on lifejackets.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 27 January 2017
Resolved
Label storage location(s) with quantity of lifejackets.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 13 February 2017
Resolved 13 February 2017
Resolution: Vessel labeled storage location(s) with quantity of lifejackets.
Lifesaving › Lifefloat › Paddle
Issued 27 January 2017
Resolved
Replace (2) oars for lifefloat.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 February 2017
Resolved 13 February 2017
Resolution: Vessel replaced (2) oars for lifefloat.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 27 January 2017
Resolved
Provide DAPI documentation in order to conduct/verify a compliance audit. 46 CFR 4/16
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 February 2017
Resolved 13 February 2017
Resolution: Vessel provided DAPI documentation.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 27 January 2017
Resolved
Lifefloat waterlight battery requires replacement.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 January 2017
Resolved 27 January 2017
Resolution: Vessel replaced battery for lifefloat waterlight.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 27 January 2017
Resolved
Provide current publications: light list, tide chart, coast pilot, and nav rules.
Condition: Invalid
Action required: 705 - Other - as specified
Due 13 February 2017
Resolved 13 February 2017
Resolution: Vessel provided current publications.
Communications › Alarms/Indicators › High Water Alarm
Issued 18 April 2016
Resolved
Prove proper operation of forward compartment high water alarm.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 April 2016
Resolution: Proved proper operation of high water alarm.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 18 April 2016
Resolved
Prove proper operation of anchor light.
Due 22 April 2016
Resolved 22 April 2016
Resolution: Proved proper operation of anchor light.
Documentation › Certificates/Documents › FCC SSL
Issued 18 April 2016
Resolved
Provide current FCC SSL.
Due 18 May 2016
Resolved 20 May 2016
Resolution: Provided current FCC SSL.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 18 April 2016
Resolved
Provide current FCC radio safety cert.
Due 22 April 2016
Resolved 22 April 2016
Resolution: Provided current FCC radio safety cert.
Fire Fighting › Remote Fuel Shutoff › General
Issued 18 April 2016
Resolved
Label emergency fuel shutoff valves.
Due 22 April 2016
Resolved 22 April 2016
Resolution: Labeled emer fuel shutoff valves.