Records from 1984 to 2011. Most recent: inspection, 6 December 2011.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 63
6 December 2011
Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4202742
19 October 2010
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3872647
13 April 2009
Drydock Exam · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3451950
22 January 2009
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3400329
4 December 2008
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3377876
8 January 2008
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3126532
9 July 2007
In-Service Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2989845
9 July 2007
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2989850
27 March 2007
Hull Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2895834
10 October 2006
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2803663
2 August 2006
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2738858
2 May 2006
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2639022
27 April 2006
In-Service Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2634956
27 April 2006
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 2634984
18 October 2005
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2517024
8 August 2005
COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2455599
25 March 2005
Hull Examination · Internal Structural Exam
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2318746
10 November 2004
Re-Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 2230205
29 September 2003
Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1916232
7 April 2003
Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1768194
30 July 2001
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1075045
17 May 2001
Re-Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1457941
9 August 2000
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1462130
29 July 1999
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 766803
24 July 1999
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 679667
17 July 1999
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 207063
10 June 1999
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 214117
6 May 1999
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1445462
20 April 1999
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 789511
4 February 1998
Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1449003
3 April 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 759106
22 March 1997
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 199776
12 February 1997
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1380758
19 April 1996
Damage Survey · Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1435754
11 March 1996
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 884581
31 January 1996
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1409442
14 November 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 29863
1 May 1995
Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 929746
27 April 1995
Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1459169
21 April 1995
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 100646
3 February 1995
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1355078
17 February 1994
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1464509
9 January 1994
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 124436
8 April 1993
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 2104
26 February 1993
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1520
26 February 1993
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 29902
19 February 1993
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1425297
10 August 1992
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 28494
31 May 1992
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 145071
27 March 1992
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1262049
25 July 1991
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1247237
9 April 1991
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1239344
6 September 1990
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 906022
19 October 1989
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 898683
12 January 1989
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1203304
1 June 1988
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1196862
26 January 1988
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1327281
21 December 1987
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1010090
5 February 1987
Hull Examination · COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1326082
18 February 1986
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 999777
25 September 1985
Credit Drydock
Administrative · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 992805
4 March 1985
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 984124
3 March 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 973576
Engineering › Fuel Oil Service System › Valve
Issued 8 January 2008
Resolved
Fuel Emergency shut off valve does not operate properly. Repair and show proper operation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 January 2008
Engineering › Fuel Oil Service System › Piping
Issued 8 January 2008
Resolved
Copper Fuel lines have compression type fittings installed for repairs. Replace fittings with flare type fittings or replace fuel pipe.
Due 31 January 2008
Resolved 10 January 2008
Stability › Watertight Integrity › General
Issued 8 January 2008
Resolved
Door Open Indicator for Galley not working properly. Repair to operate when door is in the open position
Action required: 17 - Rectify deficiencies prior to departure
Due 10 January 2008
Resolved 8 January 2008
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 9 July 2007
Resolved
33CFR159.7(c) Failure to secure type II MSD device in area where untreated discharge is prohibited.
Action required: 705 - Other - as specified
Due 9 July 2007
Resolved 9 July 2007
Operations/Management › Cargo Transfer/Lightering › Vessel Transfer Procedures on Hand
Issued 10 October 2006
Resolved
Provide copy of oil transfer procedures for the vessel.
Due 10 November 2006
Resolved 1 November 2006
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 10 October 2006
Resolved
Provide proof to USCG of company's compliance with DOT regulations for a drug ad alcohol program IAW 46CFR16.
Due 10 November 2006
Resolved 1 November 2006
Documentation › Manifests/Lists › Muster List/Emergency Instructions
Issued 10 October 2006
Resolved
Mount an emergency instructions placard for passengers and crew IAW 46CFR185.510
Due 10 November 2006
Resolved 1 November 2006
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 10 October 2006
Resolved
Provide label for deep fat fryer disconnect.
Due 10 November 2006
Resolved 1 November 2006
Engineering › Fuel Oil Service System › Valve, Control
Issued 10 October 2006
Resolved
Install fuel check valves for port and starboard ship's service generators.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 October 2006
Resolution: Installed valves; generators operating properly.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 10 October 2006
Resolved
Repair engine exhaust water and exhaust gas leaks on starboard outboard engine.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 October 2006
Resolution: Repaired leaks.
Construction/Loadline › Structures › Door
Issued 10 October 2006
Resolved
Mount watertight door on aft deck entry.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 October 2006
Resolution: Properly mounted door.
Construction/Loadline › Hull › Weld
Issued 10 October 2006
Resolved
Renew/repair approx 8 inch crack at rear port quarter bull works.
Due 10 November 2006
Resolved 1 November 2006
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 27 April 2006
Resolved
Failure to secure Type III sewage holding tank in area where discharge of untreated sewage prohibited (at pier).
Due 27 April 2006
Resolved 27 April 2006
Operations/Management › Ballast Water Managment › Mandatory Practices
Issued 8 August 2005
Resolved
Provide Ballast Water Management plan prior to 08 SEP 2005.
Condition: Unknown
Due 8 September 2005
Resolved 3 April 2007
Electrical › Lighting (emergency) › Lighting Branch Circuit
Issued 8 August 2005
Resolved
Show proper operation of Emergency Lighting prior to sailing.
Condition: Improper/Lack of Maintenance
Due 12 August 2005
Resolved 10 August 2005
Resolution: Emergency Lighting demonstrated satisfactory.
Engineering › Diesel Engine (auxiliary) › Overspeed Device
Issued 8 August 2005
Resolved
Demonstrate proper operation of Overspeed device for generators.
Condition: Improper/Lack of Maintenance
Due 12 August 2005
Resolved 10 August 2005
Resolution: Overspeed tested satisfactory.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 8 August 2005
Resolved
Provide 8 lifejackets.
Condition: Improper/Lack of Maintenance
Due 12 August 2005
Resolved 10 August 2005
Resolution: Provided 8 lifejackets.
Construction/Loadline › Penetrations › Flange Pad
Issued 8 August 2005
Resolved
Install bolts soft patch to engine room.
Condition: Improper/Lack of Maintenance
Due 12 August 2005
Resolved 10 August 2005
Documentation › Certificates/Documents › FCC SSL
Issued 8 August 2005
Resolved
Renew FCC Station license.
Condition: Improper/Lack of Maintenance
Due 12 August 2005
Resolved 10 August 2005
Documentation › Certificates/Documents › FCC SSL
Issued 8 August 2005
Resolved
Provide Radio Operator's permit for Master.
Condition: Placed in Improper Service
Due 12 August 2005
Resolved 10 August 2005
Engineering › Diesel Engine (propulsion-reduction gear) › Governor
Issued 8 August 2005
Resolved
Show proper operation of engine shutdowns.
Condition: Improper/Lack of Maintenance
Due 12 August 2005
Resolved 10 August 2005
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 8 August 2005
Resolved
Vessel operating more than 12 hours in 24 hour period without the minimum safe manning.
Due 12 August 2005
Resolved 27 March 2007
Electrical › Electric Supply System (service) › Battery Installation Ventilation
Issued 29 September 2003
Resolved
Provide ventilation louver for back-up battery located on Bridge.
Action required: 705 - Other - as specified
Due 29 October 2003
Resolved 30 September 2003
Engineering › Fuel Oil Service System
Issued 29 September 2003
Resolved
Renew fuel hoses on main engines and generators. LEGACY COMPONENT DESC: Hose
Action required: 705 - Other - as specified
Due 29 October 2003
Resolved 30 September 2003
Construction/Loadline › Structures
Issued 29 September 2003
Resolved
Make repairs by welding the forward and aft Engine Room watertight bulkheads around main engine exhaust piping. LEGACY COMPONENT DESC: Longitudinal Bulkhead
Action required: 17 - Rectify deficiencies prior to departure
Due 29 October 2003
Resolved 30 September 2003
Construction/Loadline › Hull
Issued 29 September 2003
Resolved
Make repairs to cracked frames in Generator Room and Engine Room. LEGACY COMPONENT DESC: Transverse Frame
Action required: 705 - Other - as specified
Due 29 October 2003
Resolved 30 September 2003
Construction/Loadline › Hull › Stiffener
Issued 29 September 2003
Resolved
Make repairs to cracked gusset on aft deck.
Action required: 705 - Other - as specified
Due 29 October 2003
Resolved 30 September 2003
Accommodation/Occupational Safety › Occupational Safety › Lifeline
Issued 29 September 2003
Resolved
Provide lifeline from aft deck rail to cargo rail.
Action required: 705 - Other - as specified
Due 29 October 2003
Resolved 30 September 2003
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 29 September 2003
Resolved
Renew lifeline on port and stbd lifebuoys.
Action required: 705 - Other - as specified
Due 29 October 2003
Resolved 30 September 2003
Electrical › Lighting (service) › Lighting Fixture
Issued 29 September 2003
Resolved
Hard-wire the lighting fixture for the forward void.
Action required: 705 - Other - as specified
Due 29 October 2003
Resolved 30 September 2003
Engineering › Diesel Engine (propulsion-direct drive)
Issued 29 September 2003
Resolved
Make repairs to unable all main engines to start. LEGACY COMPONENT DESC: Starter
Action required: 17 - Rectify deficiencies prior to departure
Due 29 October 2003
Resolved 30 September 2003
Electrical › Lighting (emergency)
Issued 29 September 2003
Resolved
Make emergency lighting circuit operable. LEGACY COMPONENT DESC: Lighting Branch Circuit
Action required: 17 - Rectify deficiencies prior to departure
Due 29 October 2003
Resolved 30 September 2003
Lifesaving › Lifebuoys
Issued 29 September 2003
Resolved
Renew float light line for 01 deck lifebuoy. LEGACY COMPONENT DESC: Self-igniting Lights
Action required: 705 - Other - as specified
Due 29 October 2003
Resolved 30 September 2003
Electrical › Electric Generation Source (service) › Power Requirement
Issued 29 September 2003
Resolved
Make repairs to stbd generator to obtain and hold the ship's electrical load.
Action required: 17 - Rectify deficiencies prior to departure
Due 29 October 2003
Resolved 30 September 2003
Engineering › Diesel Engine (propulsion-direct drive)
Issued 29 September 2003
Resolved
Provide chaffing gear for all flexible hoses on main engines. LEGACY COMPONENT DESC: Flexible Hoses
Action required: 705 - Other - as specified
Due 29 October 2003
Resolved 30 September 2003
Lifesaving › Lifebuoys › Quantity
Issued 29 September 2003
Resolved
Renew port 01 deck lifebuoy.
Action required: 17 - Rectify deficiencies prior to departure
Due 29 October 2003
Resolved 30 September 2003
Electrical › Electrical Distribution System (service) › Wiring
Issued 29 September 2003
Resolved
Remove extension cord from Bridge console.
Action required: 705 - Other - as specified
Due 29 October 2003
Resolved 30 September 2003
Engineering
Issued 31 January 1996
Resolved
RENEW OR REPAIR THE BRIDGE CONSOLE OIL PRESSURE GAUGE FOR THE PORT OUTBD. MAIN ENGINE. _x001C_
Condition: Unknown
Due 31 January 1996
Resolved 31 January 1996
Navigation
Issued 31 January 1996
Resolved
OBTAIN AND PLACE ON BOARD A COMPASS DEVIATION CARD.
Condition: Unknown
Due 31 January 1996
Resolved 31 January 1996
Engineering
Issued 31 January 1996
Resolved
MAKE OPERABLE THE REMOTE SHUTDOWN FOR THE STBD. OUTBD. MAIN ENGINE.
Condition: Unknown
Due 31 January 1996
Resolved 31 January 1996
Construction/Loadline
Issued 27 April 1995
Resolved
CROP AND RENEW SIDE SHELL PORT SIDE IN WAY OF #2 BALLAST TANK.
Condition: Unknown
Due 27 April 1995
Resolved 27 April 1995
Electrical
Issued 4 March 1985
Resolved
INSTALL ELECTRICAL MATTING IN FRONT OF ENTIRE SWITCHBOARD.
Condition: Unknown
Due 4 March 1985
Resolved 4 March 1985
Fire Fighting
Issued 4 March 1985
Resolved
REPLACE FIRE NOZZLE STBD SIDE PRIOR TO SAILING
Condition: Unknown
Due 4 March 1985
Resolved 4 March 1985
Electrical
Issued 4 March 1985
Resolved
REPAIR WIPERS MOTORS
Condition: Unknown
Due 4 March 1985
Resolved 4 March 1985
Navigation
Issued 4 March 1985
Resolved
OBTAIN CURRENT NAVIGATION PUBLICATIONS.
Condition: Unknown
Due 4 March 1985
Resolved 4 March 1985
Documentation
Issued 4 March 1985
Resolved
PROVIDE COPY OF VESSELS DOCUMENT FOR VERIFICATION.
Condition: Unknown
Due 4 March 1985
Resolved 4 March 1985
Electrical
Issued 4 March 1985
Resolved
CALIBRATE GROUND METER
Condition: Unknown
Due 4 March 1985
Resolved 4 March 1985