MAURY USCG vessel records Sign in
← All vessels

HRM TRADITION

HRM TRADITION is a 1984 offshore supply vessel. The Coast Guard has recorded 58 inspections since 1984, most recently in June 2021, along with 37 deficiencies and 1 casualty investigation in 2012.

Records from 1984 to 2021. Most recent: inspection, 22 June 2021.

Built
1984
Last inspected
22 June 2021
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

228990
Flag
ANTIGUA AND BARBUDA
366778920, 367036120, 367178460, 367611290 (licence lapsed)
Maury page id
psix-228990

Inspections, by type

…with no type recorded12
Years with a record 32 calendar years (1984–2021)
The 58 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 5 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it90 - Convention (Subpart B), Gross Ton
61 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDH3823MMSI 367611290 · expired · compulsorily equipped · granted 21 March 2014, cancelled 25 May 2024 · licensed under a name not among this hull’s recorded names (not shown)
WDD6853MMSI 367178460 · expired · voluntarily equipped · granted 6 April 2007, cancelled 10 June 2017
WDC5121MMSI 367036120 · expired · voluntarily equipped · granted 23 April 2005, cancelled 27 June 2015
WCZ7161MMSI 366778920 · cancelled · compulsorily equipped · granted 22 March 2000, cancelled 9 January 2006 · licensed under a name not among this hull’s recorded names (not shown)
WBB9227MMSI not assigned · expired · voluntarily equipped · granted 22 August 1996, cancelled 30 December 2006 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 58

22 June 2021 In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7232487
11 September 2017 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6264097
25 March 2014 Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4822241
25 January 2012 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 4231660
17 February 2011 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3947458
7 October 2010 Hull Examination · Examination of Repairs · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3864449
5 January 2010 COI Inspection · Administrative Inspection · Ballast Water Examination
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3658121
26 March 2009 Ballast Water Examination · Administrative Inspection · Re-Inspection · MTSA Verification
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 3440604
21 May 2008 Hull Examination · Internal Structural Exam · Examination of Repairs
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3212544
31 March 2008 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3174354
19 April 2007 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2910364
20 April 2006 Annual Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 2629674
14 November 2005 Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2534148
5 April 2005 Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2327009
18 January 2005 COI Inspection · Ballast Water Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 2276563
10 June 2004 Annual Inspection
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2100051
25 April 2003 Hull Examination
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 1780446
18 April 2002 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1608198
10 April 2001 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1387023
21 March 2000 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1436351
23 March 1999 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1410059
11 December 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 768132
18 July 1998 Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 193488
29 May 1998 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1128942
30 April 1998 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1431961
27 March 1998 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1449026
4 January 1998 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1119030
9 May 1997 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1380861
1 April 1996 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1425717
20 October 1995 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1392316
12 June 1995 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1190095
25 April 1995 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1443576
20 March 1995 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 759707
25 February 1995 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 193492
7 April 1994 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1362958
19 July 1993 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1161518
25 June 1993 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 441187
23 April 1993 Hull Examination · Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1419103
10 April 1992 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 137904
9 April 1992 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 944746
8 April 1992 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 665772
31 March 1992 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 665771
19 March 1992 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 162417
6 February 1992 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 168472
4 December 1991 Examination of Repairs
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 946274
5 June 1991 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 930435
10 October 1990 Hull Examination · MARPOL Annex II Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 899473
12 April 1990 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1218104
13 June 1989 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1039047
27 April 1988 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1342648
14 April 1988 COI Inspection · Hull Examination
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1338685
7 August 1987 Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1340819
23 April 1987 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1005663
22 December 1986 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1334965
9 July 1986 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 999507
17 April 1986 COI Inspection · Credit Drydock
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1308459
1 May 1985 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 983174
19 April 1984 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1280860

Deficiency record · 37

Fire Fighting › Fixed Fire Detection System › Heat Detectors
Issued 25 January 2012 Resolved
Thermal Detectors in engine room are painted over preventing proper operation.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 January 2012
Resolution: All new Thermal Detectors have been installed.
Documentation › Markings/Placards › Official Number (US)
Issued 25 January 2012 Resolved
Permanently mark vessels Official Numer not les than 3" high on structural bulkhead in engine room
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 February 2012
Resolved 25 April 2014
Fire Fighting › Fire Pumps › Gland Sealing
Issued 17 February 2011 Resolved
Properly secure leak of fire pump prior to sailing.
Action required: 705 - Other - as specified
Resolved 22 February 2011
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 18 April 2002 Resolved
Fire resistant sight glass not provided for day tanks.
Due 18 April 2002
Resolved 18 April 2002
Resolution: Proper sight glass provided.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 18 April 2002 Resolved
Emergency lighting not provided for stbd side water tight door and escape hatch in engine room.
Condition: Design Flaw
Due 18 April 2002
Resolved 19 April 2002
Resolution: Emergency lighting provided.
Fire Fighting › Fire Pumps
Issued 18 April 2002 Resolved
Fire pump gauge not visable from controls. LEGACY COMPONENT DESC: Gauge
Due 18 April 2002
Resolved 18 April 2002
Resolution: Moved gauge.
Engineering › Steering Gear System › Rudder
Issued 18 April 2002 Resolved
Contact being made with rudder stops.
Condition: Improper/Lack of Maintenance
Due 18 April 2002
Resolved 18 April 2002
Resolution: Linkage adjustment made so that no contact is made with rudder stops
Fire Fighting
Issued 30 April 1998 Resolved
Provide approved plans from CGHQ for fixed CO2 system. Compliance date 13JUN98.
Condition: Unknown
Due 2 June 1998
Resolved 25 June 1998
Electrical
Issued 27 March 1998 Resolved
PROPERLY HARD WIRE POWER SUPPLY CABLES FOR SSB, VHF AND LOUD HAILER WITH APPROVED MARINE GRADE WIRING.
Condition: Unknown
Due 27 March 1998
Resolved 27 March 1998
Engineering
Issued 27 March 1998 Resolved
MAKE PERMANENT REPAIRS TO WIRING ON L/O PRESSURE AND J/W TEMP SENDING UNITSON #1MDE.
Condition: Unknown
Due 27 March 1998
Resolved 27 March 1998
Electrical
Issued 27 March 1998 Resolved
INSTALL BREAKER OR BLANK PLATE IN ENGINE ROOM LIGHTING PANEL ON PORT SIDE OF ENGINE ROOM.
Condition: Unknown
Due 27 March 1998
Resolved 27 March 1998
Electrical
Issued 27 March 1998 Resolved
PROPERLY LABEL PANEL BOARDS IN ENGINE ROOM AS PER 46 CFR 111.40-11.
Condition: Unknown
Due 27 March 1998
Resolved 27 March 1998
Engineering
Issued 27 March 1998 Resolved
PROVE PROPER OPERATION OF TACHOMETERS ON BOTH MAIN ENGINES AND BOTH SSDG'S.
Condition: Unknown
Due 27 March 1998
Resolved 27 March 1998
Engineering
Issued 27 March 1998 Resolved
REMOVE PLASTIC PLUGS FROM RACOR FILTERS ON #1 SSDG AND INSTALL STEEL OR HIGH TEMP BRASS PLUGS.
Condition: Unknown
Due 27 March 1998
Resolved 27 March 1998
Engineering
Issued 27 March 1998 Resolved
PROVE PROPER OPERATION OF #1MDE LOCAL CONTROL.
Condition: Unknown
Due 27 March 1998
Resolved 27 March 1998
Lifesaving
Issued 27 March 1998 Resolved
REPAIR BROKEN PIPE HANGER ON #1SSDG J/W LINE FROM THE KEEL COOLER.
Condition: Unknown
Due 27 March 1998
Resolved 27 March 1998
Lifesaving
Issued 9 May 1997 Resolved
PROVIDE RETRO TAPE ON RING BOUYS.
Condition: Unknown
Due 9 May 1997
Resolved 9 May 1997
Construction/Loadline
Issued 9 May 1997 Resolved
PROVIDE T HANDLE FOR FOREPEAK BILGE VALVE.
Condition: Unknown
Due 9 May 1997
Resolved 9 May 1997
Construction/Loadline
Issued 9 May 1997 Resolved
PROVIDE STORM PLUGS FOR VENTS ON FOREPEAK.
Condition: Unknown
Due 9 May 1997
Resolved 9 May 1997
Lifesaving
Issued 9 May 1997 Resolved
RENEW HYDROSTATIC RELEASES FOR BOTH LIFERAFTS.
Condition: Unknown
Due 9 May 1997
Resolved 9 May 1997
Documentation
Issued 9 May 1997 Resolved
PROVIDE CURRENT ENDORSEMENT ON LOADLINE SURVEY.
Condition: Unknown
Due 9 May 1997
Resolved 9 May 1997
Electrical
Issued 9 May 1997 Resolved
REPLACE MISSING SCREWS FOR SWITCHBOARD BACK COVER.
Condition: Unknown
Due 9 May 1997
Resolved 9 May 1997
Electrical
Issued 9 May 1997 Resolved
REPLACE MISSING BLANKS ON SWITCHBOARD & ENGINE ROOM LIGHTING PANEL.
Condition: Unknown
Due 9 May 1997
Resolved 9 May 1997
Engineering
Issued 9 May 1997 Resolved
PROVE OPERATION OF MAIN ENGINE HIGH JACKET WATER ALARM.
Condition: Unknown
Due 9 May 1997
Resolved 9 May 1997
Engineering
Issued 9 May 1997 Resolved
REPAIR VENT CLOSURE ON PORT SIDE ENGINE ROOM.
Condition: Unknown
Due 9 May 1997
Resolved 9 May 1997
Navigation
Issued 9 May 1997 Resolved
REPAIR RUDDER ANGLE INDICATOR FOR EMERGENCY STEERING STATION IN ENGINE ROOM.
Condition: Unknown
Due 9 May 1997
Resolved 9 May 1997
Electrical
Issued 9 May 1997 Resolved
BOLT DOWN BATTERY COVERS IN ENGINE ROOM.
Condition: Unknown
Due 9 May 1997
Resolved 9 May 1997
Fire Fighting
Issued 9 May 1997 Resolved
REPLACE GAUGE AT FIRE PUMP ON BRIDGE.
Condition: Unknown
Due 9 May 1997
Resolved 9 May 1997
Construction/Loadline
Issued 25 April 1995 Resolved
Repair as necessary to make engine room escape hatch weathertight, and operable from both sides.
Condition: Unknown
Due 25 April 1995
Resolved 25 April 1995
Construction/Loadline
Issued 25 April 1995 Resolved
Repair as necessary to make starboard aft side (emergency escape door in engine room watertight, and operable from both sides.
Condition: Unknown
Due 25 April 1995
Resolved 25 April 1995
Accommodation/Occupational Safety
Issued 23 April 1993 Resolved
PROVIDE APPROPRIATE LOCKER SPACE FOR EACH PERSON ACCOMMODATED IN ACCORDANCEWITH 46 CFR 96.20-20 (C) (2); AND NOTIFY COGNIZANT OCMI PRIOR TO 23MAY93.
Condition: Unknown
Due 23 April 1993
Resolved 23 April 1993
Lifesaving
Issued 12 April 1990 Resolved
PRIOR TO SAILING, NOTIFY MSO PORT ARTHUR WHEN INFLATABLE LIFERAFT AND HYDROSTATIC RELEASE ARE ON VESSEL AND PROPERLY SECURED.
Condition: Unknown
Due 12 April 1990
Resolved 12 April 1990
Engineering
Issued 12 April 1990 Resolved
REPAIR OVERSPEED ON PORT MAIN ENGINE.
Condition: Unknown
Due 12 April 1990
Resolved 12 April 1990
Unknown
Issued 14 April 1988 Resolved
DEMONSTRATE OPERATION OF OVERSPEED TRIP ON THE STARBOARD PROPULSION ENGINE.
Condition: Unknown
Due 14 April 1988
Resolved 14 April 1988
Deck/Cargo
Issued 17 April 1986 Resolved
INSTALL MECHANICAL CLOSURE DEVICES IN ALL OF THE POLLUTION CONTAINMENT PANSIWO WOODEN PLUGS.
Condition: Unknown
Due 17 April 1986
Resolved 17 April 1986
Electrical
Issued 17 April 1986 Resolved
INSTALL TWO RECHARGEABLE TYPE EMERGENCY LIGHTS IWO THE NON-RECHARGEABLE TYPE LOCATED IN THE ENG. ROOM MACHINERY TRUNK AND FORWARD ENG. ROOM COMPANIONWAY
Condition: Unknown
Due 17 April 1986
Resolved 17 April 1986
Navigation
Issued 17 April 1986 Resolved
POST THE INSTRUCTIONS FOR CHANGING THE STEERING GEAR AT THE ENG. ROOM ALTERNATE STEERING STATION.
Condition: Unknown
Due 17 April 1986
Resolved 17 April 1986

Casualty record · 1

20 December 2012Routine · role: Involved in a Marine Casualty · activity 4505376
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

INT'L TRADITION (2012). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record