MAURY USCG vessel records Sign in
← All vessels

GULF FLEET NO. 68

GULF FLEET NO. 68 is a 1984 offshore supply vessel. The Coast Guard has recorded 43 inspections since 1986, most recently in February 2016, along with 91 deficiencies.

Records from 1986 to 2016. Most recent: inspection, 19 February 2016.

Built
1984
Last inspected
19 February 2016
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8301149 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
WBY3772
228994
Flag
VANUATU
303421000, 368663000 (licence lapsed)
Maury page id
psix-228994

Inspections, by type

…with no type recorded1
Years with a record 21 calendar years (1986–2016)
The 43 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 1978.

Documentation record

Tonnage as PSIX records it753 - Convention (Subpart B), Gross Ton
486 - Regulatory (Subpart C or D), Gross Ton
226 - Convention (Subpart B), Net Ton
331 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDB6517MMSI 303421000 · cancelled · compulsorily equipped · granted 18 February 2004, cancelled 27 August 2004
WBY3772MMSI 368663000 · expired · compulsorily equipped · granted 16 September 1998, cancelled 16 May 2004
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 43

19 February 2016 Deficiency Check
Physical examination · Activities Europe · Activity 5818032
19 May 2006 Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2653532
27 June 2005 Administrative Inspection
Administrative · Activities Europe · Activity 2404444
29 December 2003 Security Plan Review - VSP
Administrative · Marine Safety Center (MSC) · Activity 1976363
2 September 2003 Type not recorded
No type recorded · Activities Europe · Activity 1894177
19 July 2003 Periodic Inspection
Physical examination · Activities Europe · Activity 1813265
15 April 2002 Annual Inspection · Deficiency Check
Physical examination · Activities Europe · Activity 1602563
10 October 2001 Hull Examination · Re-Inspection
Physical examination · Activities Europe · Activity 1362529
18 August 2000 Deficiency Check
Physical examination · Activities Europe · Activity 821755
3 April 2000 Deficiency Check
Physical examination · Activities Europe · Activity 1047741
4 March 2000 COI Inspection
Physical examination · Activities Europe · Activity 1365629
29 April 1999 Deficiency Check
Physical examination · Activities Europe · Activity 1128913
3 March 1999 Hull Examination · Re-Inspection
Physical examination · Activities Europe · Activity 1360775
4 March 1998 COI Inspection
Physical examination · Activities Europe · Activity 1120480
16 February 1997 Re-Inspection
Physical examination · Activities Europe · Activity 1097120
8 November 1996 Deficiency Check
Physical examination · Activities Europe · Activity 1171307
2 June 1996 Deficiency Check · Hull Examination
Physical examination · Activities Europe · Activity 1353952
18 March 1996 Administrative
Administrative · Activities Europe - OLD · USCG Northeast District (CGD-NE) · Activity 884614
8 March 1996 COI Inspection
Physical examination · Activities Europe - OLD · USCG Northeast District (CGD-NE) · Activity 1377640
18 April 1995 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1165960
16 February 1995 Re-Inspection · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1141064
15 December 1994 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 849619
15 December 1994 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 849620
21 September 1994 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 860904
25 April 1994 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 859510
25 February 1994 MARPOL Annex V Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1166461
24 February 1994 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 856231
9 October 1993 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 845343
15 April 1993 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 836801
20 July 1992 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1261718
4 June 1992 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 957487
10 April 1992 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 950279
28 April 1991 Re-Inspection · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1251784
2 April 1991 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1236501
7 April 1990 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 922355
29 March 1989 Re-Inspection · Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1208583
30 January 1989 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1031568
4 October 1988 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1196311
11 April 1988 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1035196
8 June 1987 Deficiency Check
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1004147
28 May 1987 Re-Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1028204
25 May 1987 Administrative
Administrative · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1028200
9 April 1986 COI Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 989110

Deficiency record · 91

Lifesaving › Inflatable Liferafts
Issued 30 July 2003 Resolved
1. Provide liferaft serviced at USCG Facility approved for the manufacturer of the raft. RFD Raft on board serviced for Merlin Tide Vanuatu Flag Vessel. LEGACY COMPONENT DESC: servicing station
Action required: 17 - Rectify deficiencies prior to departure
Due 11 August 2003
Resolved 31 July 2003
Resolution: replacement raft supplied
Documentation › Safety/Response Plans/Programs
Issued 30 July 2003 Resolved
2. Documentation of the SOPEP Annual Review not available. Provide copy of annual review of SOPEP Letter. LEGACY COMPONENT DESC: SOPEP
Action required: 705 - Other - as specified
Due 30 August 2003
Resolved 8 August 2003
Resolution: Received FAX copy stating annual review completed. VERIFY NEXT INSP
Documentation › Certificates/Documents
Issued 30 July 2003 Resolved
3. Post certificate of Inspection in accordance with 46CFR 91.01-5 LEGACY COMPONENT DESC: Certificate of Inspection
Action required: 705 - Other - as specified
Due 30 August 2003
Resolved 4 August 2003
Resolution: FAX received stating COI posted. VERIFY NEXT INSP
Navigation › Collision/Grounding Avoidance
Issued 30 July 2003 Resolved
4. Stern light lens clouded. Renew or repair sternlight to make visibility compliant with RULE 22 Navigation Rules. COMDTINST M16672.2C LEGACY COMPONENT DESC: Navigation Lights
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 August 2003
Resolved 4 August 2003
Resolution: Received FAX stating light "fixed" VERIFY NEXT INSP
Deck/Cargo › Ballast
Issued 30 July 2003 Resolved
5. Make permanent repair the the holed and leaking fuel fill line passing through #3 port ballast tank. LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 August 2003
Resolved 4 August 2003
Resolution: Receive FAX stating "fixed" 02.08.03. VERIFY NEXT EXAM
Fire Fighting › Self-contained Breathing Apparatus
Issued 30 July 2003 Resolved
6.Two types of self contained breathing apparatus on board with incompatible air supply bottles. Provide compatible MSHA and NIOSH approved breathing apparatus with compatible bottles LEGACY COMPONENT DESC: Air Bottle
Action required: 17 - Rectify deficiencies prior to departure
Due 30 August 2003
Resolved 30 July 2003
Resolution: Sighted compatable unit placed on board.
Fire Fighting › Firemans Outfit
Issued 30 July 2003 Resolved
7. Provide TYPE II or TYPE III flashlight marked in accordance with ASTM F1014 for fireman's outfits. LEGACY COMPONENT DESC: Lantern (Electric Safety Lamp)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 August 2003
Resolved 1 September 2003
Resolution: Received FAX stating ; Two type II flashlights placed in each fireman''s outfit. VERIFY AT NEXT VISIT
Stability › Watertight Integrity
Issued 30 July 2003 Resolved
8. Renew wasted and holes vent risers, fill pipes, etc. main deck. LEGACY COMPONENT DESC: Vent risers
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 August 2003
Resolved 4 August 2003
Resolution: Received fax signed by vessel master stating repairs completed. VERIFY AT NEXT INSP
Fire Fighting › Fire Main
Issued 30 July 2003 Resolved
9. Renew wasted and holed firemain sections in the engine room. Upon completion of repairs hydro test to 1.25 MAWP. LEGACY COMPONENT DESC: Condition
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 4 August 2003
Resolution: Received fax signed by vessel master stating firemain FIXED and tested VERIFY AT NEXT EXAM
Fire Fighting › Miscellaneous Items
Issued 30 July 2003 Resolved
10. Repair paint locker door to make proper closure. LEGACY COMPONENT DESC: Paint/Flammable Liquid Lockers
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 August 2003
Resolved 4 August 2003
Resolution: Received fax signed by vessel master stating that the paint locker door was fixed. VERIFY AT NEXT EXAM
Engineering › Pressure Vessel
Issued 30 July 2003 Resolved
11. Provide proper relief valve for the potable water pressure tank and the sanitary pressure tank. LEGACY COMPONENT DESC: Relief Valve
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 August 2003
Resolved 4 August 2003
Resolution: Received fax signed by vessel master stating fixed. VERIFY AT NEXT EXAM
Accommodation/Occupational Safety › Occupational Safety
Issued 30 July 2003 Resolved
12. Vessel has non NIOSH approved EEBDs on board. Provide NIOSH approved EEBD.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 August 2003
Resolved 19 February 2016
Resolution: Vessel Reflagged Deficiencies no longer apply.
Engineering › Pressure Vessel
Issued 30 July 2003 Resolved
13. Properly hard pipe the air supply line in the tunnel supplying air forward in lieu of the existing "permanent" rubber hose. LEGACY COMPONENT DESC: Piping
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 August 2003
Resolved 30 July 2003
Resolution: Air line removed.
Lifesaving › Rescue Boat Equipment
Issued 30 July 2003 Resolved
14. Provide proper bridle for the workboat.
Action required: 705 - Other - as specified
Due 30 August 2003
Resolved 4 August 2003
Resolution: Received fax signed by vessel master stating new bridle made. VERIFY AT NEXT INSP
Engineering › Pressure Vessel
Issued 30 July 2003 Resolved
15. Remove permanently attached air charging line from the sanitary (flush) water tank IAW 46 CFR54.01-15 LEGACY COMPONENT DESC: Piping
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 August 2003
Resolved 30 July 2003
Resolution: Air supply line removed
Pollution Prevention/Response › Prevention Equipment
Issued 30 July 2003 Resolved
16. Trouble shoot, repair and prove proper operation of the Marine Sanitation Device (MSD) LEGACY COMPONENT DESC: Marine Sanitation Device, Type II
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 August 2003
Resolved 1 September 2003
Resolution: Received FAX stating ; Defective hose replaced. VERIFY AT NEXT VISIT
Electrical › Electrical Distribution System (service)
Issued 30 July 2003 Resolved
17.Trouble shoot, identify ground fault on the main switchboard and eliminate. LEGACY COMPONENT DESC: Ground Detection
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 August 2003
Resolved 1 September 2003
Resolution: Received fax signed by vessel master stating fixed. Both generators and switchboards were checked and found in good order. VERIFY AT NEXT INSPECTION
Lifesaving › Rescue Boat › Hull (combination rigid/inflated)
Issued 30 July 2003 Resolved
18. Make permanent repair to the work rescue/work boat and weight test to 1.1X weight of the boat capacity. LEGACY COMPONENT DESC: Hull (combination rigid/inflated)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 September 2003
Resolved 19 February 2016
Resolution: vessel reflagged Def''s no longer apply
Navigation › Piloting/Steering
Issued 30 July 2003 Resolved
19. Provide up to date copy of the rules of the road on board the vessel in accordance with 46CFR 88 LEGACY COMPONENT DESC: Inland Navigation Rules
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 August 2003
Resolved 4 August 2003
Resolution: Received fax signed by vessel master stating 2002 edition on board. VERIFY AT NEXT EXAM
Pollution Prevention/Response › Prevention Equipment
Issued 15 April 2002 Resolved
Plugs for main deck fuel oil containment drains missing. Provide proper plug devices for fuel oil containment port and starboard side. LEGACY COMPONENT DESC: Drains/Scuppers (means of closure)
Condition: Improper/Lack of Maintenance
Due 17 May 2002
Resolved 25 May 2002
Resolution: Received faxed copy of vessel''s log book stating proper plugs were installed for the containment.
Communications › Alarms/Indicators
Issued 15 April 2002 Resolved
Renew missing /burned out indicator bulbs in machinery space alarm panel located in the engineroom. LEGACY COMPONENT DESC: Lube Oil Low Pressure Alarm
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 May 2002
Resolved 25 April 2002
Resolution: Received fax confirmation from vessel master that the missing and burned out bulbs in the machinery space alarm panel were installed and tested.
Construction/Loadline › Penetrations
Issued 15 April 2002 Resolved
Forepeak reach rod not operational. Trouble shoot repair and prove proper operation of fore peak control. Properly label valve control and provide key for socket in the immediate area. LEGACY COMPONENT DESC: Valve Flange
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 May 2002
Resolved 25 April 2002
Resolution: Received fax confirmation that the forepeak reach rod was repaired, tested, properly labeled, and proved with a key for the socket operation in the immediate area.
Lifesaving › Launching Appliances
Issued 15 April 2002 Resolved
Prior to placing vessel in service prove proper operation of rescue boat davit. Proper operation to include launching and retrieval of the boat. LEGACY COMPONENT DESC: Winch
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 17 May 2002
Resolved 25 April 2002
Resolution: Received faxed copy of vessel''s log indicating boat davit winch was overhauled and tested.
Communications › Radio Communications › EPIRB
Issued 15 April 2002 Resolved
EPIRB misssing registration sticker. Properly afixed decal to EPIRB
Condition: Improper/Lack of Maintenance
Due 17 April 2002
Resolved 17 April 2002
Resolution: Found decal on afixed to SART
Electrical › Electrical Distribution System (service)
Issued 15 April 2002 Resolved
Electrical panel box 6 missing breaker blanks. LEGACY COMPONENT DESC: Panelboard
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 May 2002
Resolved 17 April 2002
Accommodation/Occupational Safety › Potable Water System
Issued 15 April 2002 Resolved
Electric water heater relief valve drain directed over a electrical control box.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 April 2002
Resolved 16 April 2002
Accommodation/Occupational Safety › Refrigeration (stores)
Issued 15 April 2002 Resolved
Meat locker door latch release frozen. Trouble shoot report and prove proper operation of latch. LEGACY COMPONENT DESC: Door release
Condition: Improper/Lack of Maintenance
Due 17 April 2002
Resolved 16 April 2002
Resolution: exercised
Fire Fighting › Miscellaneous Items › B Class Division Penetrations
Issued 15 April 2002 Resolved
Renew wasted fuel oil vent flame screen for forward port side goose neck vent.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 April 2002
Resolved 17 April 2002
Resolution: renewed
Fire Fighting
Issued 10 October 2001 Resolved
Master to conduct fire and abandon ship drill using the guidance in CG-840 OSV booklet. On completion of drills record drill details in the official log and fax a copy of the entry to The [name withheld].
Condition: Unknown
Due 1 November 2001
Resolved 17 April 2002
Electrical
Issued 10 October 2001 Resolved
Renew all emergency light batteries and prove proper operation of emergencylighting.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Due 1 November 2001
Resolved 1 November 2001
Construction/Loadline
Issued 10 October 2001 Resolved
Complete bulk tank installation and enclose deck prior to getting underway.The repair is to be witnessed by a USCG Marine Inspector or attending ABS Surveyor if a Marine Inspector is not available.
Condition: Unknown
Due 10 October 2001
Resolved 10 October 2001
Construction/Loadline
Issued 3 April 2000 Resolved
Make permanent repairs to the steel in the bow thruster area. Submit classreport verifying that repairs have been satisfactory made.
Condition: Unknown
Due 3 April 2000
Resolved 3 April 2000
Lifesaving
Issued 4 March 2000 Resolved
Provide a new paint locker for on-deck stowage of paints and flammable liquids.
Condition: Unknown
Due 4 March 2000
Resolved 4 March 2000
Documentation
Issued 4 March 2000 Resolved
Provide a valid safety radio certificate.
Condition: Unknown
Due 4 March 2000
Resolved 4 March 2000
Construction/Loadline
Issued 3 March 1999 Resolved
MAKE CHAIN LOCKER DECK COVERS WATERTIGHT.
Condition: Unknown
Due 22 March 1999
Resolved 22 March 1999
Engineering
Issued 3 March 1999 Resolved
RENEW LOCAL TACHOMETER FOR CENTERLINE BOW THRUSTER.
Condition: Unknown
Due 3 March 1999
Resolved 3 March 1999
Fire Fighting
Issued 3 March 1999 Resolved
RE-PACK ALL FIRE HYDRANTS AND FIRE HOSE NOZZLE HANDLES.
Condition: Unknown
Due 3 March 1999
Resolved 3 March 1999
Navigation
Issued 3 March 1999 Resolved
PROVIDE CURRENT TABLES, AFRICA PILOT, LIST OF LIGHTS, AND 33 CFR 1-199.
Condition: Unknown
Due 3 March 1999
Resolved 3 March 1999
Deck/Cargo
Issued 3 March 1999 Resolved
PROVIDE HANDLES FOR TWO BULK TANK PRESSURE RELIEF VALVES.
Condition: Unknown
Due 3 March 1999
Resolved 3 March 1999
Navigation
Issued 3 March 1999 Resolved
REMOVE CONSOLE MAGNETS AND PROPERLY ADJUST MAGNETIC COMPASS USING APPROPRIATE MAGNETS.
Condition: Unknown
Due 3 March 1999
Resolved 3 March 1999
Lifesaving
Issued 3 March 1999 Resolved
REPLACE SART WITH FCC ACCEPTED DEVICE.
Condition: Unknown
Due 3 March 1999
Resolved 3 March 1999
Construction/Loadline
Issued 2 June 1996 Resolved
HYDROSTATICALLY TEST ALL SHELL PLATE INSERTS, THRUSTER TUNNELS (TWO) AND WATERTIGHT BULKHEADS FORWARD OF THE ALLEY WAY (FRAME 18) AND BELOW THE FOC'SL DECK, TO THE SATISFACTION OF THE ATTENDING ABS SURVEYOR.
Condition: Unknown
Due 2 June 1996
Resolved 2 June 1996
Deck/Cargo
Issued 2 June 1996 Resolved
PROVIDE ORIGINAL ANCHOR CHAIN THICKNESS READINGS FOR THE PORT AND STARBOARDCHAINS.
Condition: Unknown
Due 2 June 1996
Resolved 2 June 1996
Documentation
Issued 2 June 1996 Resolved
PRIOR TO CONDUCTING ANCHOR OPERATIONS (WITH THE NEW WINCH AND ASSOCIATED DECK EQUIPMENT) AND OPERATION THE NEW BOW THRUSTER, PROVIDE A NEW STABILITYLETTER FROM THE U.S. COAST GUARD MARINE SAFETY CENTER.
Condition: Unknown
Due 15 June 1996
Resolved 3 July 1996
Deck/Cargo
Issued 2 June 1996 Resolved
VEE AND WELD (V+W) A ONE (01) INCH FRACTURE IN WAY OF THE #5 STARBOARD BULKTANK BULKHEAD, COMMON TO THE ALLEYWAY, LOCATED APPROXIMATELY ONE (01) FOOT FORWARD AND TWO (02) FEET DOWN FROM THE FORWARD FILL PIPE.
Condition: Unknown
Due 2 June 1996
Resolved 2 June 1996
Documentation
Issued 8 March 1996 Resolved
PROVE COMPLIANCE WITH MARPOL 73/78 TO MAINTAIN VALIDITY OF IOPP CERTIFICATEAS FOLLOWS: PROVIDE STANDARD DISCHARGE CONNECTION IAW REG. 19, PROVE PROPEROPERATION OF OILY WATER SEPARATOR, AND PROVIDE TANK CAPACITIES FOR SLOP RETENTION.
Condition: Unknown
Due 8 March 1996
Resolved 8 March 1996
Documentation
Issued 8 March 1996 Resolved
PROVIDE FCC RADIOTELEPHONY CERTIFICATE IAW SOLAS Ch. IV Reg. 4.
Condition: Unknown
Due 21 March 1996
Resolved 21 March 1996
Lifesaving
Issued 8 March 1996 Resolved
PROVE VESSEL MEETS STOWAGE, LAUNCHING, AND FLOAT-FREE REQUEIREMENTS OF 46 CFR 94.15 FOR (2) LIFERAFTS LOCATED ON PORT AND STBD BRIDGE WINGS.
Condition: Unknown
Due 8 March 1996
Resolved 8 March 1996
Lifesaving
Issued 16 February 1995 Resolved
CONDUCTED AN ANNUAL INSPECTION OF ALL LIFERAFTS NLT 30APR95.
Condition: Unknown
Due 28 March 1995
Resolved 28 March 1995
Lifesaving
Issued 16 February 1995 Resolved
INSTALL GENERAL ALARM & PLACARD IN BOW THRUSTER COMPT. AS PER 46 CFR 113.25-9(A).
Condition: Unknown
Due 16 February 1995
Resolved 16 February 1995
Fire Fighting
Issued 16 February 1995 Resolved
REMOUNT (MAKE ACCESSIBLE) THE PORT FWD E/R CO2 FIRE EXTINGUISHER.
Condition: Unknown
Due 28 March 1995
Resolved 28 March 1995
Lifesaving
Issued 16 February 1995 Resolved
UPDATE VSL'S FIRE CONTROL PLAN.
Condition: Unknown
Due 28 March 1995
Resolved 28 March 1995
Construction/Loadline
Issued 16 February 1995 Resolved
REPAIR ALL WASTED TANK VENT SCREENS AS REQUIRED.
Condition: Unknown
Due 28 March 1995
Resolved 28 March 1995
Lifesaving
Issued 16 February 1995 Resolved
PROVE PROPER OPERATION OF ALDIST LAMP AND WIRING CIRCUIT.
Condition: Unknown
Due 16 February 1995
Resolved 16 February 1995
Electrical
Issued 16 February 1995 Resolved
LABEL ALL MOTOR CONTROLERS IN FWD ALLEYWAY.
Condition: Unknown
Due 28 March 1995
Resolved 28 March 1995
Electrical
Issued 16 February 1995 Resolved
ADJUST NO.1 SSDG OVERSPEED DEVICE BETWEEN 1980-2035 RPM'S.
Condition: Unknown
Due 28 March 1995
Resolved 28 March 1995
Electrical
Issued 16 February 1995 Resolved
LABEL ALL EMERGENCY BATTERIES LOCATED OUTSIDE PILOT HOUSE.
Condition: Unknown
Due 28 March 1995
Resolved 28 March 1995
Deck/Cargo
Issued 16 February 1995 Resolved
PROPERLY PROVE OPERATION OF ALL BULK TANK RELIEF VALVES.
Condition: Unknown
Due 28 March 1995
Resolved 28 March 1995
Electrical
Issued 16 February 1995 Resolved
REMOVE DEAD ENDED CABLE ABOVE PORTABLE H2O TANK IN THE ENGINEROOM.
Condition: Unknown
Due 28 March 1995
Resolved 28 March 1995
Construction/Loadline
Issued 24 February 1994 Resolved
VESSEL MAY NOT BE OPERATED WITH A TRIM THAT EXCEEDS 1.7 FEET UNTIL A REVISED STABILITY LETTER IS ISSUED BY THE USCG. THIS REQT MAY BE CLEARED BYPROVIDING COPY OF THE REVISED STABILITY LETTER TO [name withheld].
Condition: Unknown
Due 24 February 1994
Resolved 24 February 1994
Construction/Loadline
Issued 24 February 1994 Resolved
VESSEL PROHIBITED FROM OPERATING ITS CRANE WHILE VESSEL IS UNDERWAY UNTIL AREVISED STABILITY LETTER IS RECEIVED FROM THE USCG. THIS REQT MAY BE CLEARED BY PROVIDING A COPY OF THE STABILITY LETTER TO [name withheld].
Condition: Unknown
Due 24 February 1994
Resolved 24 February 1994
Electrical
Issued 15 April 1993 Resolved
REPLACE NAVIGATION LIGHT INDICATOR PANEL WITH ONE IN ACCORDANCE WITH 46 CFR111.75-17.
Condition: Unknown
Due 15 April 1993
Resolved 15 April 1993
Lifesaving
Issued 15 April 1993 Resolved
REPLACE PAINT LOCKER WITH AS ORIGINAL DESIGN LOCKER.
Condition: Unknown
Due 15 April 1993
Resolved 15 April 1993
Electrical
Issued 15 April 1993 Resolved
PROVE PROPER OPERATION OF #1 ELECTRIC SWITCH BOARD REVERSE POWER RELAY.
Condition: Unknown
Due 15 April 1993
Resolved 15 April 1993
Engineering
Issued 10 April 1992 Resolved
PROVE PROPER OPERATION OF THE OIL/WATER SEPARATOR. OIL WASTE SHALL BE RETAINED ONBOARD VESSEL UNTIL THIS REQUIREMENT HAS BEEN SATISFIED.
Condition: Unknown
Due 10 April 1992
Resolved 10 April 1992
Electrical
Issued 10 April 1992 Resolved
PROVE PROPER OPERATION OF THE REVERSE POWER RELAY FOR THE STARBOARDF (#2) GENERATOR. GENERATORS SHALL NOT BE OPERATED IN PARALLEL UNTIL THIS REQUIREMENT HAS BENN SATISFIED.
Condition: Unknown
Due 10 April 1992
Resolved 10 April 1992
Fire Fighting
Issued 11 April 1988 Resolved
PROVIDE A SCHEMATIC DIAGRAM OF THE FIXED CO2 SYS. WITH INSTRUCTIONS CONCERNING ALTERNATE DISCHARGE METHODS, AT EACH CONTROL STATION IAW 46 CFR 95.15-10(H).
Condition: Unknown
Due 11 April 1988
Resolved 11 April 1988
Construction/Loadline
Issued 11 April 1988 Resolved
REPAIR OR REPLACE WTH FOR PORT SIDE ENGINEROOM ACCESS FROM MAIN DECK.
Condition: Unknown
Due 11 April 1988
Resolved 11 April 1988
Fire Fighting
Issued 11 April 1988 Resolved
PROVIDE A FIXED CO2 SYSTEM FOR THE PAINT LOCKER IAW 46 CFR 95.05-10(C).
Condition: Unknown
Due 11 April 1988
Resolved 11 April 1988
Fire Fighting
Issued 11 April 1988 Resolved
PROVIDE A RELIEF VALVE AND A DISCHARGE PRESSURE GUAGE FOR THE FIRE PUMP IAW46 CFR 95.10-5(D) & (E).
Condition: Unknown
Due 11 April 1988
Resolved 11 April 1988
Navigation
Issued 11 April 1988 Resolved
PROVIDE A NAV LIGHT INDICATOR PANEL IN THE WHEELHOUSE THAT MEETS THE REQUIREMENTS OF 46 CRF 111.75-17(B).
Condition: Unknown
Due 11 April 1988
Resolved 11 April 1988
Navigation
Issued 11 April 1988 Resolved
PROVIDE A DUPLICATE LIGHT SOURCE FOR THE VESSEL'S SIDE, MASTHEAD, STERN & RANGE LIGHTS IAW 46 CFR 111.75-17(C).
Condition: Unknown
Due 11 April 1988
Resolved 11 April 1988
Navigation
Issued 11 April 1988 Resolved
PROVIDE IN THE ENGINEROOM INSTRUCTIONS FOR THE EMERGENCY STEERING SYSTEMS CHANGE OVER PROCEEDURES IAW 46 CFR 97.37-33(A).
Condition: Unknown
Due 11 April 1988
Resolved 11 April 1988
Electrical
Issued 11 April 1988 Resolved
REPALCE CRACKED ENGINE ALARM BATTERY ON STBD SIDE OF THE PILOT HOUSE.
Condition: Unknown
Due 11 April 1988
Resolved 11 April 1988
Electrical
Issued 11 April 1988 Resolved
PROVIDE LABELS, OUTSIDE OR INSIDE OF EMERGENCY BATTERY LOCKERS, STATING BATTERIES SERVICE AND VOLTAGE.
Condition: Unknown
Due 11 April 1988
Resolved 11 April 1988
Electrical
Issued 11 April 1988 Resolved
PROVE PROPER OPERATION OF EMERGENCY LIGHTING IN PILOTHOUSE, GALLEY AND ENGINEROOM.
Condition: Unknown
Due 11 April 1988
Resolved 11 April 1988
Deck/Cargo
Issued 11 April 1988 Resolved
PROVIDE RELIEF VALVES, ASME APPROVED FOR THE STBD AFT, STBD FWD & PORT FWD BULK TANKS
Condition: Unknown
Due 11 April 1988
Resolved 11 April 1988
Construction/Loadline
Issued 11 April 1988 Resolved
PROVIDE BALLS IN THE FOLLOWING BALL CHEEK TYPE VENTS: TANK 17 PORT: STBD, TANK 8 PORT: STBD, TANK 5 PORT: STBD.
Condition: Unknown
Due 11 April 1988
Resolved 11 April 1988
Accommodation/Occupational Safety
Issued 11 April 1988 Resolved
PROVIDE A STORM RAIL IN ER PASSAGEWAY BY EITHER REMOVING STORAGE BINS OR INSTALLING NEW STBD SIDE RAIL.
Condition: Unknown
Due 11 April 1988
Resolved 11 April 1988
Construction/Loadline
Issued 11 April 1988 Resolved
PROVE PROPER OPERATION OF THE FOREPEAK REACH ROD AND PROVIDE FOR IT A NAMEPLATE IAW 46 CFR 56.50-1(B).
Condition: Unknown
Due 11 April 1988
Resolved 11 April 1988
Construction/Loadline
Issued 11 April 1988 Resolved
CLEAN THE FOREPEAK TANK SO AS TO ALLOW INTERNAL EXAMINATION OF WELDS.
Condition: Unknown
Due 11 April 1988
Resolved 11 April 1988
Engineering
Issued 11 April 1988 Resolved
REMOVE THE THREADED PLUG INSTALLED IN THE F/O TRANSFER PUMP. DISCHARGE LINEAND REPLACE LINE AS ORIGINAL.
Condition: Unknown
Due 11 April 1988
Resolved 11 April 1988
Lifesaving
Issued 11 April 1988 Resolved
PROVIDE A RIGID HULLED RESCUE BOAT WITH BUILT IN BUOYANCY IAW 46 CFR 94.10-5(E).
Condition: Unknown
Due 11 April 1988
Resolved 11 April 1988
Engineering
Issued 11 April 1988 Resolved
PROVIDE RELIEF VALVES FOR THE 2 SSAR'S, ASME APPROVED AND SET NMT 200 PSI, WITH A STAMPED SET PRESSURE NMT 10% ABOVE MAWP IAW 46 CFR 54.15-10(G).
Condition: Unknown
Due 11 April 1988
Resolved 11 April 1988
Lifesaving
Issued 11 April 1988 Resolved
SERVICE THE TWO SWITLIK LIFERAFTS AT A USCG APPROVED FACILITY IAW 46 CFR 91.25-15(A)(6).
Condition: Unknown
Due 11 April 1988
Resolved 11 April 1988
Electrical
Issued 11 April 1988 Resolved
PROVIDE STUFFING TUBES FOR THE SAT NAV AND LORAN WIRING THAT PENETRATES THESTBD PILOTHOUSE BLKHD.
Condition: Unknown
Due 11 April 1988
Resolved 11 April 1988
Construction/Loadline
Issued 11 April 1988 Resolved
PROVIDE MEANS OF CLOSURE FOR STACK VENTS IAW 46 CFR 92.15-10(A)
Condition: Unknown
Due 11 April 1988
Resolved 11 April 1988
Lifesaving
Issued 28 May 1987 Resolved
REPLACE 3 NONE COAST GUARD APPROVED RING BUOYS LOCATED ON THE BRIDGE DECK WITH COAST GUARD APPROVED.
Condition: Unknown
Due 28 May 1987
Resolved 28 May 1987
Lifesaving
Issued 28 May 1987 Resolved
REPAIR OR RENEW THE OUTBOARD ENGINE USED ON THE RESCUE BOAT.
Condition: Unknown
Due 28 May 1987
Resolved 28 May 1987
Deck/Cargo
Issued 9 April 1986 Resolved
OBTAIN MACHINERY SPACE OILY WATER PIPING STANDARD DISCHARGE CONNECTION.
Condition: Unknown
Due 9 April 1986
Resolved 9 April 1986
Deck/Cargo
Issued 9 April 1986 Resolved
HYDRO TEST FUEL OIL TRANSFER HOSE AND STENCIL HOSE WITH DATE AND PRESSURE OR INFORMATION IN A LOGBOOK WHICH CAN BE MADE AVAILABLE FOR INSPECTION.
Condition: Unknown
Due 9 April 1986
Resolved 9 April 1986

Ownership record