Records from 2016 to 2021. Most recent: inspection, 12 April 2021.
Documentation record
Registered dimensions (L × B × D)38.7 ft × 13.7 ft × 5.5 ft
Registered tonnagegross 20 / net 16
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderRESMONDO BOAT WORKS · PERDIDO BEACH, AL, UNITED STATES · built 1984
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portPANAMA CITY BEACH, FL
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it20 - Simplified, Gross Ton
16 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 6
12 April 2021
Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7173711
4 August 2020
Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7023906
20 March 2019
Administrative Inspection · Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6647245
2 April 2018
Annual Inspection · Administrative Inspection · Deficiency Check · DAPI Audit
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6381764
20 March 2017
COI Inspection · Hull Examination · DAPI Audit · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6104827
6 June 2016
DAPI Audit · Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5898670
Engineering › Steering Gear System › Rudder Bearing
Issued 2 April 2018
Resolved
Tighten / Replace packing on both rudders
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 May 2018
Resolved 3 May 2018
Resolution: Vessel replaced packing
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 2 April 2018
Resolved
Tighten / replace packing on both engine shafts
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 May 2018
Resolved 3 May 2018
Resolution: Vessel replaced packing
Electrical › Electric Generation Source (service) › Generator
Issued 20 March 2017
Resolved
Provide a means to measure Volts, Amps, and Hertz for vessels generator.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 April 2017
Resolved 26 April 2017
Resolution: Witnessed
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 20 March 2017
Resolved
STBD side engine exhuast clamps need to be replaced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 April 2017
Resolved 26 April 2017
Resolution: Witnessed
Electrical › Electrical Distribution System (service) › Junction Box
Issued 20 March 2017
Resolved
FWD berthing under ladder replace Junction box.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 April 2017
Resolved 26 April 2017
Resolution: witnessed
Navigation › Piloting/Steering › Coast Guard Light List
Issued 20 March 2017
Resolved
Provide current Nav Pubs/Light List.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 April 2017
Resolved 26 April 2017
Resolution: Witnessed
Communications › Radio Communications › VHF Radiotelephone
Issued 6 June 2016
Resolved
Input the MMSI number into the DSC Radio to ID the vessel.
Condition: Invalid
Action required: 705 - Other - as specified
Due 6 June 2016
Resolved 20 June 2016
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 6 June 2016
Resolved
Alcohol testing equipment for 4 persons to meet the 2 hour requirment.
Action required: 705 - Other - as specified
Due 6 June 2016
Resolved 20 June 2016
Personnel › Certificates/Documents/Licenses › License, Operator
Issued 6 June 2016
Resolved
Provide FCC LIC for vessel Captain.
Action required: 705 - Other - as specified
Due 6 June 2016
Resolved 20 June 2016
Engineering › Reduction Gearing/Clutches › Shaft
Issued 6 June 2016
Resolved
Leaking Shaft Packing STBD side.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 June 2016
Resolved 20 June 2016
Communications › Radio Communications › EPIRB
Issued 6 June 2016
Resolved
EPIRB hydrostic release has expired replace expired device.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 June 2016
Resolved 20 June 2016
Electrical › Electrical Distribution System (service) › Shore Connection Box
Issued 6 June 2016
Resolved
Shore power splice needs to be in a juction box.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 June 2016
Resolved 20 June 2016
Resolution: Provided picture of fixed shore tie