← All vessels
FOREST VENTURE
Freight Ship · General Dry Cargo Ship class · Built 1970s · USCG Southeast District (CGD-SE) · Other hulls named FOREST VENTURE
FOREST VENTURE is a 1977 freight ship. The Coast Guard has recorded 47 inspections since 2000, most recently in March 2010, along with 15 deficiencies and 9 operational controls.
Records from 2000 to 2010. Most recent: inspection, 12 March 2010.
- Built
- 1977
- Last inspected
- 12 March 2010
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 15 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
7618569 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
P3SK8
2290
Flag
CYPRUS
—
Maury page id
psix-2290
Inspections, by type
The 47 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it8453 - Dead Weight, Ton
54729 - Displacement, Ton
10199 - Convention (Subpart B), Gross Ton
10199 - Simplified, Gross Ton
3059 - Convention (Subpart B), Net Ton
3059 - Simplified, Net Ton
54729 - Displacement, Ton
10199 - Convention (Subpart B), Gross Ton
10199 - Simplified, Gross Ton
3059 - Convention (Subpart B), Net Ton
3059 - Simplified, Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 47
12 March 2010
Type not recorded
No type recorded · USCGC SEAHAWK (WPB 87323) · USCG Southeast District (CGD-SE) · Activity 3695366
8 February 2010
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3676905
8 December 2009
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3646547
11 July 2009
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3531009
10 April 2009
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3450229
8 April 2009
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3457279
30 November 2008
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3371466
10 August 2008
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3294547
9 July 2008
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3262426
21 June 2008
Type not recorded
No type recorded · Station Dauphin Island · USCG Heartland District (CGD-H) · Activity 3243442
21 June 2008
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3268558
4 June 2008
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3222212
3 April 2008
NPV Safety Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3177092
2 April 2008
Type not recorded
No type recorded · Station Pascagoula · USCG Heartland District (CGD-H) · Activity 3176419
2 April 2008
Type not recorded
No type recorded · Station Pascagoula · USCG Heartland District (CGD-H) · Activity 3176425
1 April 2008
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3175551
7 January 2008
Ballast Water Examination · PII Safety Exam · ISPS III Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3123773
2 January 2008
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3123644
16 June 2007
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2962457
30 October 2006
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2834788
13 September 2006
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2721924
2 September 2005
Random ISPS/MTSA/PSC · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2481758
21 July 2005
PII Safety Exam · ISPS III Exam · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2434676
28 April 2005
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2353372
27 April 2005
Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2344377
5 January 2005
Random ISPS/MTSA/PSC
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2269186
21 October 2004
ISPS II Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2225453
16 July 2004
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2135130
10 June 2004
MTSA/ISPS Verification
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 2094594
31 October 2003
MARPOL Annex I Examination · Ballast Water Examination · MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1939617
3 July 2003
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1834313
18 June 2003
Security Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1820552
16 June 2003
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1819128
11 June 2003
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1815152
11 June 2003
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1815305
18 April 2003
Annual Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1776279
25 November 2002
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1710539
12 June 2002
Ballast Water Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1629838
11 June 2002
Security Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1629621
26 April 2002
Security Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1609924
28 March 2002
Annual Inspection · Ballast Water Examination
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1598462
14 March 2002
Security Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1493568
8 March 2002
Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 1492374
2 February 2002
Security Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1483483
20 October 2001
Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 294751
27 March 2001
Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 288935
27 March 2000
Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 276203
Deficiency record · 15
Documentation › Logs/Records › Logbook (official)
Issued 8 December 2009
Resolved
VESSEL FAILED TO LOG AND RERFORM PREARRIVAL TEST PRIOR TO ARRIVING TO PORT AS REQUIRED BY US REGULATION.
Fire Fighting › Fire Hoses › Location
Issued 8 December 2009
Resolved
FIRE HOSES IN CARGO HOLDS ARE NOT READILY AVAILABLE BECAUSE OF STOWAGE OF CARGO GEAR IN FRONT OF STORAGE BOXES. CLEAR ACCESS [name withheld] PROVIDED FOR ALL CREW MEMBERS.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 8 December 2009
Resolved
SMOKE DETECTORS ABOVE HEAT EXCHANGER AND PORT SIDE PURIFIER FLAT WERE FOUND INOPERABLE. REPAIRS MUST BE MADE IN ACCORDANCE WITH MANUFACTORER INSTRUCTIONS.
Navigation › Piloting/Steering › Gyro Compass
Issued 9 July 2008
Resolved
Vessel has an inoperable gyro compass.
Lifesaving › Lifeboat › Seating
Issued 4 June 2008
Resolved
Observed temporary repair on port lifeboat IWO starboard seat. Temporary repair is pulling away from fiberglass. Starboard life boat, Observed fracture and creasing IWO port forward seating. Additionally longitudinal support bars in stern of STBD Life boat is broken and another is wasted rectify prior to departure from COTP Mobile.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 30 May 2008
Resolved
110v Panel has a ground. Solas 60 II-1/27(a)(i)(1). To the satisfaction of Class.
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Fixed Piping System
Issued 3 April 2008
Resolved
OWS is not to be used in U.S. waters until class certifies proper piping arrangements to overboard discharge valve. Vessel does not use OWS. Oil discharge valve was locked. Oil is in the 2nd stage after OWS piping system. Pipe is also used for sludge tank discharge. Receipts for discharge to facilities were provided. MARPOL 73/78 I/16 50a.
Fire Fighting › Fire Hoses › Condition
Issued 13 September 2006
Resolved
Two Fire Hoses on the Bow (one next to the Emergency Generator and the other amidships) burst from the fire station when energized. The vessel shall repair/replace fire hoses and have class perform tests to ensure all hoses are working properly.
SOLAS 2004 CH II-2 Reg 10.2.3
Fire Fighting › Means of Escape › Number
Issued 13 September 2006
Resolved
EEBD located in Engine Room on Starboard Side Second Deck was expired. Vessel required to recharge/replace.
SOLAS 2004 Ch. II-2 Reg. 13.4.3
Electrical › Lighting (service) › Lighting Fixture
Issued 21 July 2005
Resolved
REPAIR/REPLACE LIGHT COVER ABOVE SEWAGE PLANT TO SATISFACTION OF CLASS PRIOR TO NEXT U.S. PORT AFTER SAILING FORGEIN. SOLAS CHAPTER I REG II.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 21 July 2005
Resolved
REPAIR OILY WATER SEPARATOR TO SATISFACTION OF CLASSIFICATION PRIOR TO NEXT U.S. PORT AFTER SAILING FORGEIN. OWS MUST BE SECURED AND INCINERATOR MUST BE USED WHILE UNDERWAY AND BILGE SLOPES SHALL GO TO RECIVEING FACILITY. MARPOL ANNEX 1 REG 16 (1997 EDITION).
Fire Fighting › Fire Pumps › Pressure
Issued 21 July 2005
Resolved
PRESSURE GAUGES FOR MAIN FIRE PUMP NOT WORKING. REPLACE/REPAIR TO SATISFACTION OF CLASSIFICATION PRIOR TO NEXT U.S. PORT AFTER SAILING FORGEIN. SOLAS CHAPTER I REG 11.
Accommodation/Occupational Safety › Ventilation › General
Issued 21 July 2005
Resolved
REPAIR/REPLACE EXHAUST FAN IN HOSPITAL WASHROOM TO SATISFACTION OF CLASS PRIOR TO NEXT U.S. PORT AFTER SAILING FORIEGN. SOLAS CHAPTER I REG 11.
Navigation › Piloting/Steering
Issued 11 June 2003
Resolved
Gyrorepeater is having intermittent problems LEGACY COMPONENT DESC: Gryo Compass Repeater
Navigation › Piloting/Steering
Issued 25 November 2002
Resolved
The Gyro Repeater is not in sync with the Master Gyro. Issued Letter of deviation allowing vessel to enter port of Savannah and requiring repairs to be made prior to departure. LEGACY COMPONENT DESC: Gryo Compass Repeater
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.