Records from 2016 to 2026. Most recent: inspection, 1 June 2026.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 17 January 2025
Resolved
Except under paragraph (a)(2) of this section, vessels that operate in salt water must be examined in accordance with the intervals set forth in Table 91.40-3(a)of this section. Where Table 91.40-3(a) indicates a 2.5 year examinations interval, its means a vessel must undergo two examinations within any five year period. No more than three years may elapse between any two examinations. Vessel shall complete a credit dry-dock and internal examination prior to movement.
Action required: 60 - Rectify deficiencies prior to movement
Due 17 January 2025
Resolved 13 May 2026
Resolution: DD and ISE credited
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 31 January 2023
Resolved
Each cargo vessel must carry at least one rescue boat. The vessel does not have a rescue boat or launching appliance that meet the requirement of 46 CFR 199.262. USACE shall ensure a rescue boat and launching appliance is installed meeting the above reference or provide a letter IAW the MOU that the USACE District Commander has made a decision to allow the vessel to operate with its current rescue boat configuration, which is not in compliance with the applicable regulation.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 7 February 2023
Resolved 3 February 2023
Resolution: Cleared until further review/determination can be made.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 16 December 2022
Resolved
If, during an internal structural damage or deterioration to the hull plating, structural members, or cargo tanks is discovered, the OCMI may require the vessel to be drydocked or taken out of service to further assess damage and to effect permanent repairs. Vessel must remove Temporary repair in #3 Stbd Void slope Weld seam leak, to include aft doubler.
Condition: Improper/Lack of Maintenance
Action required: 66 - Prior to drilling or production operations
Resolved 1 February 2023
Resolution: Items repaired to the satisfaction of the attended MI/ABS Surveyor.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 16 December 2022
Resolved
If, during an internal structural damage or deterioration to the hull plating, structural members, or cargo tanks is discovered, the OCMI may require the vessel to be drydocked or taken out of service to further assess damage and to effect permanent repairs. Wasted plate on port shaft tube must be repaired.
Condition: Improper/Lack of Maintenance
Action required: 66 - Prior to drilling or production operations
Resolved 1 February 2023
Resolution: Items repaired to the satisfaction of the attended MI/ABS Surveyor.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 16 December 2022
Resolved
If, during an internal structural damage or deterioration to the hull plating, structural members, or cargo tanks is discovered, the OCMI may require the vessel to be drydocked or taken out of service to further assess damage and to effect permanent repairs. Wasted Hull plate in Auxiliary Machinery Room must be repaired.
Condition: Improper/Lack of Maintenance
Action required: 66 - Prior to drilling or production operations
Resolved 1 February 2023
Resolution: Items repaired to the satisfaction of the attended MI/ABS Surveyor.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 16 December 2022
Resolved
If, during an internal structural damage or deterioration to the hull plating, structural members, or cargo tanks is discovered, the OCMI may require the vessel to be drydocked or taken out of service to further assess damage and to effect permanent repairs. Wasted plate on watertight bulkhead in #4 Center void must be repaired.
Action required: 66 - Prior to drilling or production operations
Resolved 1 February 2023
Resolution: Items repaired to the satisfaction of the attended MI/ABS Surveyor.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 16 December 2022
Resolved
If, during an internal structural damage or deterioration to the hull plating, structural members, or cargo tanks is discovered, the OCMI may require the vessel to be drydocked or taken out of service to further assess damage and to effect permanent repairs. Wasted Hull plating in #2 Void must be repaired.
Condition: Improper/Lack of Maintenance
Action required: 66 - Prior to drilling or production operations
Resolved 1 February 2023
Resolution: Items repaired to the satisfaction of the attended MI/ABS Surveyor.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 16 December 2022
Resolved
If, during an internal structural damage or deterioration to the hull plating, structural members, or cargo tanks is discovered, the OCMI may require the vessel to be drydocked or taken out of service to further assess damage and to effect permanent repairs. Port side #3 void fuel tank deck insert must be repaired.
Condition: Improper/Lack of Maintenance
Action required: 66 - Prior to drilling or production operations
Resolved 1 February 2023
Resolution: Items repaired to the satisfaction of the attended MI/ABS Surveyor.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 16 December 2022
Resolved
If, during an internal structural damage or deterioration to the hull plating, structural members, or cargo tanks is discovered, the OCMI may require the vessel to be drydocked or taken out of service to further assess damage and to effect permanent repairs.Wasted dredge collection pipes in the #5 port and stbd void must be repaired.
Condition: Improper/Lack of Maintenance
Action required: 66 - Prior to drilling or production operations
Resolved 1 February 2023
Resolution: Items repaired to the satisfaction of the attended MI/ABS Surveyor.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 16 December 2022
Resolved
If, during an internal structural damage or deterioration to the hull plating, structural members, or cargo tanks is discovered, the OCMI may require the vessel to be drydocked or taken out of service to further assess damage and to effect permanent repairs. Failed hose test hatch repairs must be made and NDT'd.
Condition: Improper/Lack of Maintenance
Action required: 66 - Prior to drilling or production operations
Resolved 1 February 2023
Resolution: Items repaired to the satisfaction of the attended MI/ABS Surveyor.
02 - Structural Conditions › N/A - No Subsystem › Decks - corrosion
Issued 16 December 2022
Resolved
If, during an internal structural damage or deterioration to the hull plating, structural members, or cargo tanks is discovered, the OCMI may require the vessel to be drydocked or taken out of service to further assess damage and to effect permanent repairs. Complete repairs to S-17 fan room bulkhead and deck
Condition: Improper/Lack of Maintenance
Action required: 66 - Prior to drilling or production operations
Resolved 1 February 2023
Resolution: Items repaired to the satisfaction of the attended MI/ABS Surveyor.
09 - Working and Living Conditions › 092 - Working Conditions › Winches & capstans
Issued 25 February 2022
Resolved
Vessels in ocean, coastwise, or Great Lakes service, except unmanned barges, shall be fitted with anchors, chains, and hawsers in general agreement with the Standards established by the American Bureau of Shipping.
Starboard windless motor brake failed and the drum clutch casing structurally failed during anchor deployment. This event rendered that system incapable of raising the starboard anchor during mooring or anchoring operations.
Repair starboard windless system, replace clutch and test system to the satisfaction of the attending USCG Marine Inspector. Also have the Portside windless clutch casing non destructively tested to ensure casing is not structurally compromised or damaged.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 31 October 2022
Resolved 19 December 2022
Resolution: Repair completed at Detyens Shipyard, Charleston, SC and satisfactory opeerational test witnessed.
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 25 February 2022
Resolved
All enclosed spaces within the vessel shall be properly vented or ventilated. Means shall be provided to close off all vents and ventilators. (b) Means shall be provided for stopping all fans in ventilation systems serving machinery and cargo spaces and for closing all doorways, ventilators and annular spaces around funnels and other openings to such spaces, from outside these spaces, in case of fire.
Replace or repair inoperable engine room supply fan motor to the satisfaction of th attending USCG Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 March 2022
Resolved 22 March 2022
Resolution: Intake fan motor replaced new. All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 25 February 2022
Resolved
Electric installations on vessels must ensure: (1) Maintenance of services necessary for safety under normal and emergency conditions. (2) Protection of passengers, crew, other persons, and the vessel from electrical hazards. (3) Maintenance of system integrity through compliance with the applicable system requirements (IEEE, NEC, IEC, etc.) to which plan review has been approved.
Properly tag out electrical power switch and secure exposed dead end wires to previously installed space vent fan motor.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 March 2022
Resolved 22 March 2022
Resolution: Dead wire removed and electrical power switch was capped off.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 25 February 2022
Resolved
Arrangements shall be made whereby water in the compartments will drain to the suction pipes. Efficient means shall be provided for draining water from all tank tops, other watertight flats and insulated holds. Peak tanks, chain lockers and decks over peak tanks may be drained by eductors, ejectors, or hand pumps.
Provide repair plan detailing repairs to, non functioning, fore and aft peak tank de-watering system remote control valves.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 March 2022
Resolved 14 December 2022
Resolution: Witnessed op test of aft peak remote control bilge pump valve.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 8 March 2021
Resolved
Ships port davit failed to lift lifeboat after man overboard drill. Davit shall be in proper operation at all times, show proper operation in the presence of Marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 8 April 2021
Resolved 10 March 2021
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 8 March 2021
Resolved
Ships rudder angle indicator is not properly indicating at the local operating station and the Bridge. Show proper operation of the rudder angle indicator and steering gear. Show proper operation in the presence of Marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 8 April 2021
Resolved 19 March 2021
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 8 March 2021
Resolved
Each cargo vessel must carry at least one rescue boat. Vessel's crew stated that they do not have a designated rescue boat. Provide proof of exemption or alternative to the regulations.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 18 April 2021
Resolved 3 February 2023
Resolution: Cleared until further review/determination can be made.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 8 March 2021
Resolved
Fuel oil purifier has leaking hoses. Repair leaks to the satisfaction of attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 March 2021
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 8 March 2021
Resolved
Marine cable transit in the Engine Room had cable pulled and not blocked with appropriate blank. Replace with blank or reinstall cable to make water and vapor tight.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 March 2021
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 8 March 2021
Resolved
Starboard steering gear hydraulic hose has damage exposing the interior braided metal. Repair/replace hose
to the satisfaction of attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 March 2021
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 8 March 2021
Resolved
Flexible hoses attached to two of the CO2 bottles in the
emergency generator space have hoses that are exhibiting
dry-rot and kinked. Provide servicing/repair report from an approved fire servicing company to the satisfaction of a Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 March 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 August 2020
Resolved
Port steering motor inop.
Action required: 60 - Rectify deficiencies prior to movement
Due 19 September 2020
Resolved 22 August 2020
Resolution: Boland Marine & Industrial LLC provided report stating that coupling dogs had been completely sheered. Technician aligned and installed new coupling. Operational tested for 45 minutes along with testing steering from all stations.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 11 June 2020
Resolved
Fire Dampers located on exhaust stack for machinery space pinned-open and prevent closure of space for fire protection. Provide safe/efficient means of closure and/or demonstrate satisfactory operation of protective fire dampers in presence of CG Marine Inspector.
46 CFR 92.15-10(b)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 June 2020
Resolution: Verified original inspector check downdraft louvers, not dampers. Inspected dampers for satisfactory operation.
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 11 June 2020
Resolved
Conduct satisfactory Fire & Abandon Ship drills in presence of CG Marine Inspector prior to departure.
46CFR 96.06-1
46 CFR 199.780(c)(2)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 June 2020
Resolution: Witnessed satisfactory Fire & Boat drills.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 11 June 2020
Resolved
Vessel does not maintain a Weekly Inspection checklist for Lifesaving Equipment (Lifeboat maintenance). Create and provide to satisfaction of CG Marine Inspector.
46CFR 96.06-1
46 CFR 199.190(d)(2)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 June 2020
Resolution: Vessel created weekly lifeboat inspection isntruction and log entry standard including weekly requirements.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 11 June 2020
Resolved
Vessel does not have record of Annual servicing for Lifeboats. Provide annual servicing report that Lifeboats have been inspected & serviced to satisfaction of CG Marine Inspector.
46CFR 96.06-1
46 CFR 199.190(f)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 June 2020
Resolution: Vessel provided letter for annual inspection and servicing of both lifeboats.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 June 2020
Resolved
Start air system contains a 250mawp Pressure Vessel with a 275mawp relief valve, system operates at 250psi. Replace relief valve with that of proper setting and prove proper operation of system at safe working pressure to satisfaction of CG Marine Inspector.
46 CFR 96.03-1(a)
46 CFR 54.15-10(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 June 2020
Resolution: Pressure relief valve replaced with 250psi valve, system regulated down to 245psi, does not affect start air capabilities.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 11 June 2020
Resolved
Galley doors located on "A" Class bulkheads are missing self-closing devices and have hold-back hooks installed. Install properly adjusted self-closing devices and remove hold-back hooks to satisfaction of CG Marine Inspector.
46 CFR 92.07-10(d)(4)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 June 2020
Resolution: Hold-backs have been removed and self-closing devices have been added and adjusted.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 11 June 2020
Resolved
Multiple spaces FWD of vessel that are CO2 protected have failed hatch gaskets. Repair/replace gaskets to satisfaction of CG Marine Inspector.
46 CFR 92.05-1(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 June 2020
Resolution: Hatch gaskets on FWD machinery space doors have been replaced and chalk tested.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 11 June 2020
Resolved
Multiple spaces FWD of vessel that are CO2 protected have open bulkhead penetrations. Correct to satisfaction of CG Marine Inspector.
46 CFR 92.05-1(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 June 2020
Resolution: 3 bulkhead penetrations in FWD machinery spaces have been plugged with threaded fittings.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 11 June 2020
Resolved
Bow thruster space has access plates that are open and missing hardware posing free communication between anchor locker and space. Repair to satisfaction of CG Marine Inspector.
46 CFR 97.15-7(a)
46 CFR 93.01-1
46 CFR 170.165(a)
46 CFR 42.15(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 June 2020
Resolution: Chain link access plates in bow thruster space have been installed with all hardware.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 11 June 2020
Resolved
FWD Pump Motor Room has access door with additional dogs/locks restricting safe means of escape. Correct to satisfaction of CG Marine Inspector.
46 CFR 92.10-20(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 June 2020
Resolution: Dogs and hinges have been lubricated and adjusted for easier use. Special note has been added that Vessel plans to switch to QAWTD's at next shipyard availability.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 11 June 2020
Resolved
No signage instructing crew/personnel with location of Lifeboat Embarkation Areas from nearby accommodations. Install signage to satisfaction of CG Marine Inspector.
46 CFR 97.37-42
46 CFR 199.80(c)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 June 2020
Resolution: Muster location and lifeboat signage has been added in adjacent passageways/accomodation areas.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 June 2020
Resolved
FWD Lamp Locker shares space for paint locker ventilation motor. Verify system meets Class 1 Division 1 Hazardous Location installation to satisfaction of CG Marine Inspector.
46 CFR 96.05-1(a)
46 CFR 111.101-21
46 CFR 111.105-11(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 June 2020
Resolution: Verified motor/fan unit in lamp locker ventilation duct is non-sparking/intrinsically safe. Explosion proof light fixture has been ordered for space.
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 11 June 2020
Resolved
Log weekly soundings of appropriate tanks associated with the storage of oils and use of Oily Water Separator in the vessels Oil Record Book.
46 CFR 97.35-3(b)
33 CFR 151.25(d)
Action required: 10 - Deficiency Rectified
Resolved 11 June 2020
Resolution: Logged weekly soundings.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 11 June 2020
Resolved
Remove storage of corrosives found in paint locker and separate to satisfaction of CG Marine Inspector.
46 CFR 91.25-50(a)
Action required: 10 - Deficiency Rectified
Resolved 11 June 2020
Resolution: Corrosives removed from paint locker.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 11 June 2020
Resolved
Lifeboats are required to be lowered every 3 months and launched annually. Conduct maintenance and log to satisfaction of CG Marine Inspector.
46 CFR 96.06-1
46 CFR 199.180(d)(6)
Action required: 10 - Deficiency Rectified
Resolved 11 June 2020
Resolution: Lifeboats were lowered and maintenance was conducted.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 15 August 2019
Resolved
01) Currently the EDG shuts down on high J/W temp. 46CFR 112.50(g) states alarm only not shutdown. Correct issue so the EDG does not shut down on high J/W temp. 30 Day Compliance date (15Sep2019) to the satisfaction of the Coast Guard.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 September 2019
Resolved 4 November 2019
Resolution: Verified EDG now only alarms and does not shut down for high J/W temp.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 15 August 2019
Resolved
02)Currently the EDG has no Audible alarm in the EDG room, nor in the engine control room. IAW 46CFR 112.50(h). Until the issue is resolved when the EDG is run, the EDG room must be manned by a qualified engineer. 30 Day Compliance date (15Sep2019) to the satisfaction of the Coast Guard.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 September 2019
Resolved 4 November 2019
Resolution: Verified an audible alarm has been installed in the EDG room and now alarms in the ECR.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 15 August 2019
Resolved
03)Currently the EDG PTSP states “Check Valve to Remain Closed” for the L/O testing. This check valve cannot be found. Correct the procedures or find the check valve. 30 Day Compliance Date (15Sep2019) to the satisfaction of the Coast Guard.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 September 2019
Resolved 4 November 2019
Resolution: Verified the PSTP has been amended and the check valve portion has been removed.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 15 August 2019
Resolved
04)Currently the EDG L/O test did not go IAW the procedures, no Low L/O alarm happened only the shutdown did and that was above where the low alarm should have gone off. Correct the EDG alarm and shutdown for the low L/O. 30 Day Compliance Date (15Sep2019) to the satisfaction of the Coast Guard.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 September 2019
Resolved 4 November 2019
Resolution: Verified and tested the L/O alarm and shutdown are functioning as designed
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 15 August 2019
Resolved
05)Currently at the EDG CO2 release station, there is no sign to state there are manual closures to be closed when activating the CO2 system. Install signage to include these closures. 46CFR95.15-10(h). This has been rectified prior to completion of today’s inspection. Issued and Cleared same date.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 15 August 2019
Resolved 15 August 2019
Resolution: Deficiency rectified same day, signs installed.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 15 August 2019
Resolved
06)This goes along with deficiency number 2 issued today. In the engine control room there is in the view screen the previous EDG’s alarm system and controls, the current new EDG is not installed there. Only lacking a computer code to get it re installed. Correct this monitoring issue so alarms work in the control room. 46CFR112.50(h) 30 Day Compliance Date (15Sep2019) to the satisfaction of the Coast Guard.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 September 2019
Resolved 4 November 2019
Resolution: Verfied the EDG alarms and monitoring system now works in the ECR.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 15 August 2019
Resolved
07)Currently the PTSP’s for the SS/DG’s are not complete IAW 46CFR61.40-10. The step by step instructions are missing. Correct this part of the PTSP’s for the ships SS/DG’s. 30 Day Compliance Date (15Sep2019) to the satisfaction of the Coast Guard.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 September 2019
Resolved 4 November 2019
Resolution: Verified the PSTP have been updated with step by step instructions for the SSDGs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 15 August 2019
Resolved
08)Currently on the STBD SS/DG there is a F/O leak at a F/O high pressure injection line at the #4 inboard head. Correct this issue by the end of today’s inspection. This has been corrected. Issued and cleared same day.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 15 August 2019
Resolved 15 August 2019
Resolution: F/O Line has been sealed and tightened.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 August 2019
Resolved
09)Currently fire stations #29 and #35 are in need of PMS, green corrosion covers the blank cap on the “Y” gate and the main stop valves for the stations. Correct before the end of today’s inspection. This has been corrected. Issued and cleared same day.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 15 August 2019
Resolved 15 August 2019
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 15 August 2019
Resolved
10)Currently the Galley roll top door will not close completely. This fire door must close completely. Correct issue with the door. The ¾” to 1” gap at the bottom needs to be filled. 30 Day compliance Date (15Sep2019) to research possible new door. To the satisfaction of the Coast Guard.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 September 2019
Resolved 4 November 2019
Resolution: Verified the galley rolltop door closes fully.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 15 August 2019
Resolved
11)Currently the following deck penetrations are wasted and in serious need of replacement. Cable penetrations boxes PORT side main deck number F2, F3, and the PORT Trunnion winch penetrations. STBD side the F4, F5, F6, and the STBD Trunnion winch penetrations, crop and renew, replace all. 46CFR171.111(e). This item is to be completed at the scheduled shipyard period in September 2019. 90 Day Compliance date (15Nov2019) To the satisfaction of the Coast Guard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 September 2019
Resolved 4 November 2019
Resolution: Verified all deck penetrations in question have been rectified.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 15 August 2019
Resolved
12)Currently the High L/O temp alarm on the Port SS/DG is not working, correct problem and retest. Due to the constantly manned engine room a 30 Day Compliance Date (15Sep2019) To the satisfaction of the Coast Guard.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 September 2019
Resolved 4 November 2019
Resolution: Verified and tested the portside generator high L/O temp alarm has been replaced and is functioning properly
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 15 August 2019
Resolved
13)Currently the Center SS/DG’s reverse power relay is not working. Repair and call USCG to witness testing. This repair is required to be completed prior to sailing. A 30 Day Compliance Date (15Sep2019) to the Satisfaction of the Coast Guard.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 16 August 2019
Resolved 16 August 2019
Resolution: Reverse Power repaired and notification received.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 15 August 2019
Resolved
14)Currently in the AMR upper FWD BLKHD Rox Box has been repaired with in correct rubber blocks, miss matched manufactures. Correct the previous repairs to the box and use correct manufactures blocks. A 30 Day Compliance Date (15Sep2019) to the satisfaction of the Coast Guard. 46CRF171.111(e)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 September 2019
Resolved 4 November 2019
Resolution: Verified the bulkhead penetrations have been repaired using the proper non mismatched blocks
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 15 August 2019
Resolved
15)Currently FWD Generator room BLKHD penetrations (Stuffing Tube Type) not securing wires in the penetrations and also the wires at the same location are not properly attached to the BLKHD. A 30 Day Compliance Date (15Sep2019) to the satisfaction of the Coast Guard. 46CFR171.111(e).
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 September 2019
Resolved 4 November 2019
Resolution: Verified all wires in question have been secured properly
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 15 August 2019
Resolved
16)Currently in the AMR STBD BLKHD a Fixed CO2 system nozzle is being blocked by boxes, Remove the obstruction prior to the close of today’s inspection. This deficiency has been corrected prior to the end of today’s inspection. Issued and cleared the same day.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 15 August 2019
Resolved 15 August 2019
Resolution: All material removed from the space blocking the nozzle.
Engineering › Steering Gear System › Power Unit
Issued 28 March 2018
Resolved
Prior to departure from Sector Mobile Zone, provide a technician report from SPERRY and CAPT conducting steering test under load while underway.
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 28 March 2018
Resolution: Ballasted ship to loaded condition, in heavy seas, with engines full ahead, conducting repeated 20-degree course changes and holding various courses, in all modes of steering, for one hour. The steering system is performing correctly.
Engineering › Steering Gear System › Power Unit
Issued 28 March 2018
Resolved
Prior to departure from port, vessel is required to provide tug assist.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 28 March 2018
Resolution: Tug assist provided for vessel departure.
Electrical › Electrical Distribution System (service) › Wiring
Issued 28 March 2018
Resolved
Make permanent repairs to the main cable transit in the emergency generator room on the bulkhead behind the switchboard to the satisfaction of the attending Coast Guard Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 28 April 2018
Resolved 23 May 2018
Resolution: Fire caulk replaced with rox blocks by contractor ([name withheld]).
Construction/Loadline › Hull › Hull Plating
Issued 18 December 2017
Resolved
All leaks in the vessel shall be repaired and tested to the satisfaction of the attending marine inspector prior to movement. Vessel shall notify USCG Sector Mobile prior to any movemnet outside of the shipyard. Master shall ensure the safety of the vessel is maintained at all times. IAW 46 CFR 91.40-3
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 January 2018
Resolved 5 February 2018
Resolution: All repairs were made and tested sat.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 2 March 2017
Resolved
Provide annual servicing report for fixed CO2 system.
Condition: Invalid
Action required: 705 - Other - as specified
Due 9 March 2017
Resolved 9 March 2017
Resolution: Received, reviewed, and accepted annual fire servicing report.
Communications › Radio Communications › VHF Radiotelephone
Issued 2 March 2017
Resolved
Provide GMDSS and Radio annual servicing report.
Condition: Invalid
Action required: 705 - Other - as specified
Due 9 March 2017
Resolved 9 March 2017
Resolution: Received, reviewed, and accepted annual servicing report.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 2 March 2017
Resolved
Vessel reported inoperative OWS, make proper repairs to installed OWS.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 April 2017
Resolved 4 May 2017
Resolution: Received, reviewed, and accepted statement from master that OWS was operating as designed.
Lifesaving › Lifeboat › Handholds/Handrails
Issued 2 March 2017
Resolved
Replace damaged cotter pin on turnbuckle on starboard lifeboat aft.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 9 March 2017
Resolved 9 March 2017
Resolution: Received, reviewed, and accepted masters statement/report.
Fire Fighting › Fixed Deck Foam System › Hose Connection
Issued 2 March 2017
Resolved
Vessels helo deck feeder tubes were damaged.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 9 March 2017
Resolved 9 March 2017
Resolution: Received, reviewed, and accepted masters statement/report.
Construction/Loadline › Structures › Deck Plating
Issued 2 March 2017
Resolved
Starboard trunnion service frame was damaged. Crop and renew inkind.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 6 April 2017
Resolved 9 March 2017
Resolution: Received, reviewed, and accepted masters statement that the damaged portion of the trunnion was cropped and renewed inkind.
Construction/Loadline › Structures › Deck Plating
Issued 2 March 2017
Resolved
provide and submit repair plan for replacement of damaged and corroded decking around the exterior walk way of bridge. See narrative for details.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 April 2017
Resolved 4 May 2017
Resolution: Received, reviewed, and accepted statement from master that the proper repairs had been carried out the the catwalk gratings.