MAURY USCG vessel records Sign in
← All vessels

ZHEN HUA 7

ZHEN HUA 7 is a 1983 freight ship. The Coast Guard has recorded 60 inspections since 1984, most recently in January 2010, along with 12 deficiencies.

Records from 1984 to 2010. Most recent: inspection, 20 January 2010.

Built
1983
Last inspected
20 January 2010
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8120882 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
J8B2674
229062
Flag
SAINT VINCENT AND THE GRENADINES
—
Maury page id
psix-229062

Inspections, by type

…with no type recorded35
Years with a record 22 calendar years (1984–2010)
The 60 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 16 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it30120 - Dead Weight, Ton
10417 - Convention (Subpart B), Net Ton
34724 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

TABORA Tank Ship · MISLE 224072 · 25 February 2000 · activity 480120

Inspection history · 60

20 January 2010 Deficiency Check · PII Safety Exam · ISPS II Exam
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 3666828
20 March 2008 Deficiency Check · ISPS II Exam · Ballast Water Examination · PI Safety Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 3167025
25 October 2004 Random ISPS/MTSA/PSC
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2228190
28 July 2004 ISPS II Exam · PII Safety Exam
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2148371
22 May 2002 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1619587
15 May 2002 Administrative Inspection
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1491256
14 May 2002 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1616618
19 January 2002 Certificate of Compliance
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1480443
19 April 2001 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1061679
29 May 2000 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 278260
29 May 2000 Tank Vessel Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1049428
25 February 2000 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 480120
25 March 1999 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 426746
25 March 1999 Tank Vessel Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1116364
23 February 1998 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 413064
8 January 1998 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 463003
26 February 1997 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 400444
26 February 1997 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1104209
21 July 1996 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 393336
21 July 1996 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1086658
21 January 1996 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 386997
21 January 1996 Tank Vessel Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 872869
27 January 1995 Tank Vessel Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 830155
26 January 1995 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 374663
28 September 1994 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 443841
28 September 1994 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 485017
21 June 1994 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1176799
31 March 1994 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 365541
12 February 1994 Tank Vessel Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 853932
12 February 1994 Tank Vessel Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1163221
16 April 1993 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 357732
17 February 1993 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 651451
3 February 1993 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 17127
1 February 1993 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 355983
27 January 1993 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1140088
3 December 1992 Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 831720
29 September 1992 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 457882
26 December 1991 Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 946279
1 January 1991 Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1225684
5 November 1990 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 340177
31 October 1990 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 474197
14 December 1989 Certificate of Compliance
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 915028
8 September 1989 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 472662
21 July 1989 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 516239
28 November 1988 Certificate of Compliance
Administrative · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1207611
27 November 1988 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 535219
18 October 1988 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 326302
14 October 1988 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 510527
25 April 1988 Type not recorded
No type recorded · COTP HOUSTON · USCG Heartland District (CGD-H) · Activity 453926
21 March 1988 Administrative
Administrative · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1338903
4 November 1987 Certificate of Compliance
Administrative · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1021009
23 September 1987 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 318619
25 April 1987 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 315974
22 April 1987 MARPOL Annex II Examination
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1313757
5 February 1987 Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 470033
2 August 1986 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 310552
19 May 1986 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 498973
17 July 1985 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 303197
17 July 1985 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1287602
20 September 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1282226

Deficiency record · 12

Engineering › Freshwater System (jacketwater cooling) › Fitting
Issued 20 January 2010 Resolved
Found excessive water leak from water jacket cooling O-Ring #1,2,4,5,7 and 8 were leaking. Repair or replace prior to departure to satisfaction of class society or administration..
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 January 2010
Resolution: Received class report that water leak from water jacket O rings were repaired and found satisfactory for CCS class surveyor.
Electrical › Electric Generation Source (emergency) › Switch
Issued 28 July 2004 Resolved
Prove proper operation of the automatic starting to the Emergency Generator under load to the satisfaction of the attending Marine Inspector IAW SOLAS 74 CH II-1, Reg 44.
Action required: 705 - Other - as specified
Due 29 July 2004
Resolved 29 July 2004
Resolution: Observed proper operation of automatic starting to the Emergency Generator under load.
Pollution Prevention/Response › Prevention Equipment
Issued 19 January 2002 Resolved
Inspected vsl's 15 ppm OWS and found significant amount of oil inside the discharge piping just on the inboard side of the overboard valve. Required vsl to have Class survey the system and submit a report to the CG that the OWS system is working properly prior to departure from the Port of NY. LEGACY COMPONENT DESC: Oily Water Separator (15 ppm)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 January 2002
Resolution: Received Class Report from [name withheld] stating that the T/V PHAROS''''s OWS was working properly after cleaning of OWS and replacement of filters. Class report received on 01/21/02.
Deck/Cargo
Issued 26 February 1997 Resolved
Prior to carrying oil cargoes in U.S. waters, permanently install overfill devices for each cargo tank that is independant of the gauging system._x001C_ _x001C_ 33 CFR 155.480_x001C_
Condition: Unknown
Due 10 March 1997
Resolved 10 March 1997
Deck/Cargo
Issued 21 January 1996 Resolved
VESSEL TO CONDUCT HYDROSTATIC TESTING OF CARGO PIPING.
Condition: Unknown
Due 21 January 1996
Resolved 21 January 1996
Electrical
Issued 12 February 1994 Resolved
REPAIR SOURCE GENERATOR TO SATISFACTION OF ATTENDING USCG MARINE INSPECTOR.
Condition: Unknown
Due 12 February 1994
Resolved 17 February 1994
Construction/Loadline
Issued 12 February 1994 Resolved
INSTALL AN OIL DISCHARGE MONITOR (ODMS) CAPABLE OF DISCHARGING AT 30 _x001C_ LITERS/NM. VESSEL MAY NOT OPERATE IN U.S. WATERS AFTER 06 JULY 1994 IF _x001C_ODMS IS NOT INSTALLED AND OPERATIONAL.
Condition: Unknown
Due 12 February 1994
Resolved 12 February 1994
Documentation
Issued 3 December 1992 Resolved
Update vessel's oil transfer procedures.
Condition: Unknown
Due 17 December 1992
Resolved 17 December 1992
Deck/Cargo
Issued 3 December 1992 Resolved
Repair and demonstrate proper operation of the emergency stop for the stbd cargo pump.
Condition: Unknown
Due 17 December 1992
Resolved 17 December 1992
Deck/Cargo
Issued 3 December 1992 Resolved
PRIOR TO CONDUCTING CARGO OPERATIONS THAT REQUIRE INERTING AT NEXT U.S. PORT, DEMONSTRATE PROPER OPERATION OF BOTH OF THE VESSEL'S INERT GAS SYSTEMBLOWERS.
Condition: Unknown
Due 3 December 1992
Resolved 3 December 1992
Fire Fighting
Issued 4 November 1987 Resolved
PROVIDE ON BOARD ONE ADDITIONAL COMPLETE FIRE SUIT TO THE SPECS OF SOLAS 74CHAP II-2 REG 14 TO MAKE A TOTAL OF 4 SUITS AS PER SOLAS 81 AMDMTS CHAP II-2 REG 17.3. IN THE INTERIM, A RENTED SUIT MUST BE KEPT ABOARD.
Condition: Unknown
Due 4 November 1987
Resolved 4 November 1987
Deck/Cargo
Issued 4 November 1987 Resolved
CONDUCT A 1-1/2 MAWP STATIC LIQUID PRESSURE TEST OF THE CARGO PIPING IN ACCORDANCE WITH 33CFR156.170.
Condition: Unknown
Due 4 November 1987
Resolved 4 November 1987

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.