MAURY USCG vessel records Sign in
← All vessels

BAILEY LOUISE TODD

BAILEY LOUISE TODD is a 1984 passenger vessel (inspected). The Coast Guard has recorded 79 inspections since 1985, most recently in October 2023, along with 125 deficiencies and 3 casualty investigations between 2013 and 2023.

Records from 1985 to 2023. Most recent: inspection, 8 October 2023.

Built
1984
Last inspected
8 October 2023
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDI2106
229216
Flag
UNITED STATES
367053290, 367460460, 367674780 (licence lapsed)
Maury page id
psix-229216

Inspections, by type

…with no type recorded9
Years with a record 35 calendar years (1985–2023)
The 79 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it41 - Regulatory (Subpart C or D), Gross Ton
41 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDI2106MMSI 367674780 · cancelled · compulsorily equipped · granted 28 May 2015, cancelled 11 October 2024
WDF5194MMSI 367460460 · expired · compulsorily equipped · granted 13 July 2010, cancelled 12 September 2020
WAK3559MMSI 367053290 · expired · compulsorily equipped · granted 10 May 1999, cancelled 11 July 2009 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 79

8 October 2023 Type not recorded
No type recorded · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7806774
10 August 2023 Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7764092
19 August 2022 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7555185
10 May 2022 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7448423
17 August 2021 DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7288389
2 October 2020 Examination of Repairs · Damage Survey · Deficiency Check
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7070007
2 October 2020 Type not recorded
No type recorded · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7071770
6 July 2020 Examination of Repairs · Hull Examination
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 7000487
30 March 2020 COI Inspection · Deficiency Check
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6933321
30 December 2019 Administrative Inspection
Administrative · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6880674
19 August 2019 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6787752
25 April 2019 Deficiency Check · Hull Examination
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6669927
10 August 2018 Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6507267
23 June 2017 Annual Inspection · Deficiency Check · Hull Examination
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6184401
3 May 2017 Administrative Inspection · Drydock Extension · Internal Structural Exam
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 6138214
18 August 2016 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Belfast · USCG Northeast District (CGD-NE) · Activity 5959845
2 May 2012 Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 4300139
6 January 2012 Examination of Repairs · Plan Review "T" Boat · Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 4219609
7 July 2011 Annual Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 4074373
27 April 2009 Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3457536
3 June 2008 Examination of Repairs
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3226394
25 February 2008 Plan Review "T" Boat
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3153081
28 January 2008 Excursion Permit
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3137434
14 November 2007 Examination of Repairs · Annual Inspection · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 3098480
12 April 2007 COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2904963
21 April 2006 Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2630497
14 March 2006 Plan Review "T" Boat
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2602350
18 May 2005 Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 2361386
2 April 2004 Deficiency Check · Internal Structural Exam · Annual Inspection · Hull Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 2036202
7 May 2003 Plan Review "T" Boat
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1788420
23 April 2003 Annual Inspection · Internal Structural Exam
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1779105
23 May 2002 MARPOL Annex V Examination · Deficiency Check · COI Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1619586
8 April 2002 Hull Examination · Internal Structural Exam
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1482691
5 March 2002 Plan Review "T" Boat
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1491393
7 February 2002 Plan Review "T" Boat
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1484759
23 July 2001 Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1463685
27 April 2001 Deficiency Check · Plan Review "T" Boat
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1077292
26 April 2001 Re-Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1445802
26 March 2001 Administrative
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1064616
16 February 2001 Administrative
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1058872
12 July 2000 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 820373
24 April 2000 Re-Inspection · MARPOL Annex V Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1450461
19 April 2000 Hull Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1432302
15 July 1999 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 41953
10 May 1999 Plan Review "T" Boat
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 795403
9 April 1999 Deficiency Check · MARPOL Annex V Examination · COI Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 788900
21 January 1999 Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1122255
15 January 1999 Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 811489
22 December 1998 Administrative
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 808554
22 April 1998 MARPOL Annex V Examination · Re-Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 806899
6 April 1998 Hull Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1388654
16 April 1997 MARPOL Annex V Examination · Re-Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1099661
22 April 1996 COI Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 786460
22 April 1996 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1083681
22 April 1996 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1084626
27 April 1995 MARPOL Annex V Examination · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1175123
30 March 1995 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 839648
7 April 1994 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1168997
23 April 1993 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 847335
1 April 1993 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 847336
20 October 1992 Drydock Extension
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 960613
18 July 1992 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 945715
9 July 1992 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1264879
28 April 1992 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 959976
3 April 1991 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 936023
17 August 1990 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1219931
19 June 1990 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 923640
2 May 1990 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 927709
5 April 1990 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1231090
23 March 1990 Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 917266
14 December 1989 Drydock Extension
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 910399
6 June 1989 Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 890571
9 June 1988 Hull Examination · Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 889666
30 July 1987 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1026185
23 June 1987 COI Inspection · Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1333772
25 March 1987 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1020383
10 June 1986 Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 992628
8 October 1985 Credit Drydock
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1297482
4 June 1985 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1292251

Deficiency record · 125

05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 19 August 2022 Resolved
FCC Safety certificate expired.
Action required: 705 - Other - as specified
Due 9 October 2022
Resolved 7 October 2022
Resolution: New certificate on vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 19 August 2022 Resolved
Found life ring non serviceable, replace .
Action required: 705 - Other - as specified
Due 9 October 2022
Resolved 7 October 2022
Resolution: New life ring installed on vessel.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 19 August 2022 Resolved
Found discharge assembly not displaying a visual alarm.
Action required: 705 - Other - as specified
Due 9 October 2022
Resolved 7 October 2022
Resolution: New alarm discharge device installed and test sat.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 17 August 2021 Resolved
Found DSC inop due to DGPS NEMA failure, repair replace connection.
Action required: 10 - Deficiency Rectified
Due 17 September 2021
Resolved 24 August 2021
Resolution: New DGPS installed and NEMA connection established.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 17 August 2021 Resolved
Found seat benches not attached to vessel on main deck fixed seating. Attach benches to vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 September 2021
Resolved 8 September 2021
Resolution: Benches attached to vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 17 August 2021 Resolved
Repair / replace water float light.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 September 2021
Resolved 8 September 2021
Resolution: New water float light installed.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 2 October 2020 Resolved
Vessel drifted aground has a result of breaking free of its mooring possibly causing damage. Vessel hull shall be made available for examination prior to carrying passengers for hire.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 October 2020
Resolution: Vessel drydocked pending repairs.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 2 October 2020 Resolved
Vessel drifted aground has a result of breaking free of its mooring possibly causing damage. Vessel hull shall be made available for examination prior to carrying passengers for hire.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 July 2021
Resolution: Repairs completed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 October 2020 Resolved
Vessel drifted aground has a result of breaking free of its mooring possibly causing damage. Vessel running gear shall be made available for examination prior to carrying passengers for hire.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 July 2021
Resolution: Repairs completed.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 6 July 2020 Resolved
Unstep Masts prior to 2021 Operating season.
Action required: 705 - Other - as specified
Due 17 August 2021
Resolved 16 August 2021
Resolution: Mast unstepped, inspection completed sat.
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 19 August 2019 Resolved
Provide emergency instructions. Vessel does not have instructions onboard.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 September 2019
Resolved 7 October 2019
Resolution: Recieved photographs of emergency instructions.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 August 2019 Resolved
Provide first aid kit to meet the requirmetns needed in kit. Vessel missing iodine, forceps, scissors.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 September 2019
Resolved 7 October 2019
Resolution: Recieved photographs of new equipment that was missing on the exam.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 19 August 2019 Resolved
Provide Light List and Coast Pilot
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 September 2019
Resolved 16 September 2019
Resolution: O/O submitted email with photos of corrected deficiency.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 August 2019 Resolved
Shaft Seal supply line needs to be replaced with hose meeting J1942 Standard. Hose is just plastic tubing.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 September 2019
Resolved 16 September 2019
Resolution: Replaced.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 19 August 2019 Resolved
Provide maintenance and inspection program for standing and running rigging.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 September 2019
Resolved 7 October 2019
Resolution: Mariner provided log, NVIC 2-16 was sent providing extra guidance.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 13 May 2019 Resolved
Make Repairs (in-kind) to starboard transom corner post. Marine Inspector to attend once planking is removed to examine extent of rot. Attending MI will review proposal prior to commencing actual repairs. Repairs to be completed prior to 2020 operating season.
Action required: 705 - Other - as specified
Due 1 May 2020
Resolved 6 July 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 1 May 2019 Resolved
Renew hose clamps (02) on engine and head saltwater intake hoses at through hull fittings.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 May 2019
Resolved 13 May 2019
Resolution: Replaced
01 - Certificates & Documentation › 013 - Documents › Stability Information Booklet
Issued 15 August 2018 Resolved
Provide/Post stability letter.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 September 2018
Resolved 16 August 2018
Resolution: O/O provided photo of posted stability letter,
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 August 2018 Resolved
Repair/Replace grab line on ring buoy.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 September 2018
Resolved 16 August 2018
Resolution: O/O provided photo of new line on ring.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 August 2018 Resolved
Provide donning placards for all types on board.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 September 2018
Resolved 28 August 2018
Resolution: O/O provided phto of donning placards posted.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 15 August 2018 Resolved
Provide adequate sound producing device.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 September 2018
Resolved 15 August 2018
Resolution: New horn wired and operational.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 15 August 2018 Resolved
Prove operation of stern and masthead lights. **To be corrected prior to operations at night or during reduced visibility **
Action required: 705 - Other - as specified
Due 15 August 2018
Resolved 24 August 2018
Resolution: O/O provided photos of operational lights.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 15 August 2018 Resolved
Prove proper installation/operation of DSC capability.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 September 2018
Resolved 16 August 2018
Resolution: New VHF with built in GPS/DSC installed.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 21 August 2017 Resolved
Provide valid FCC Safety Certificate.
Action required: 705 - Other - as specified
Due 21 September 2017
Resolved 14 September 2017
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 21 August 2017 Resolved
Replace battery light in ring buoy waterlight.
Action required: 705 - Other - as specified
Due 28 August 2017
Resolved 14 September 2017
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 21 August 2017 Resolved
Provide 3-6' line with clip.
Action required: 705 - Other - as specified
Due 28 August 2017
Resolved 13 September 2017
Communications › Alarms/Indicators › Fire Alarm
Issued 21 August 2017 Resolved
Mount smoke detectors (e/r and forward)
Action required: 705 - Other - as specified
Due 28 August 2017
Resolved 13 September 2017
Engineering › Fuel Oil Storage/Transfer System › Ventilation
Issued 21 August 2017 Resolved
Repair port fuel vent screen.
Action required: 705 - Other - as specified
Due 21 September 2017
Resolved 13 September 2017
Engineering › Sea-water System (primary cooling) › Sea Chest
Issued 21 August 2017 Resolved
Replace se strainer.
Action required: 705 - Other - as specified
Due 28 August 2017
Resolved 13 September 2017
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 21 August 2017 Resolved
Renew markings on (5) PFDs.
Action required: 705 - Other - as specified
Due 28 August 2017
Resolved 14 September 2017
Fire Fighting › Fire Bucket › Lanyard
Issued 21 August 2017 Resolved
Provide line and re-label (1) fire bucket.
Action required: 705 - Other - as specified
Due 28 August 2017
Resolved 13 September 2017
Engineering › Freshwater System (jacketwater cooling) › Piping
Issued 21 August 2017 Resolved
Repair coolant leak.
Action required: 705 - Other - as specified
Due 28 August 2017
Resolved 14 September 2017
Construction/Loadline › Hull › Bracket
Issued 3 May 2017 Resolved
Address soft wood stbd of stem in f'peak.
Action required: 705 - Other - as specified
Due 3 August 2017
Resolved 21 August 2017
Resolution: Area has been repaired.
Construction/Loadline › Structures › Deck Plating
Issued 3 May 2017 Resolved
Address deck leaking ivo king post in fwd cabin.
Action required: 705 - Other - as specified
Due 3 August 2017
Resolved 14 September 2017
Construction/Loadline › Hull › Transverse Frame
Issued 3 May 2017 Resolved
Address mold and wood rot outboard on engine, port side E/R in overhead frames and deck planks
Action required: 705 - Other - as specified
Due 3 August 2017
Resolved 21 August 2017
Construction/Loadline › Hull › Stiffener
Issued 3 May 2017 Resolved
Address mold and wood rot above battery bank, stbd of aft cabin
Action required: 705 - Other - as specified
Due 21 August 2017
Resolved 21 August 2017
Construction/Loadline › Hull › Stringer
Issued 3 May 2017 Resolved
Address mold and wood rot in lazerette, port, outboard of exhaust pipe
Action required: 705 - Other - as specified
Due 3 August 2017
Resolved 21 August 2017
Stability › Unintentional Flooding › General
Issued 3 May 2017 Resolved
Maintain both bilge pumps operational and preform daily checks until DDE.
Action required: 705 - Other - as specified
Due 3 August 2017
Resolved 21 August 2017
Communications › Radio Communications › EPIRB
Issued 18 August 2016 Resolved
Remove old EPRIB or replace with new, registered EPRIB to the current vsl.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 September 2016
Resolved 19 October 2016
Resolution: EPIRB removed vsl
Pollution Prevention/Response › Prevention Equipment › Sewage System Tank
Issued 18 August 2016 Resolved
Replace the hose clamps on the MSD discharge @ seacock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 September 2016
Resolved 19 October 2016
Resolution: double hose clamps were installed
Engineering › Engine Controls (Electric/Electronic) › Actuator
Issued 18 August 2016 Resolved
Repair or replace the engine tachometer(RPM) at the operating station.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 September 2016
Resolved 19 October 2016
Resolution: RPM Gauge was working
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 18 August 2016 Resolved
Provide a valid FCC Safety Radiotelephony cert.
Condition: Invalid
Action required: 705 - Other - as specified
Due 16 September 2016
Resolved 19 October 2016
Resolution: FCC bridge to bridge was valid
Operations/Management › Drills/Instruction › Not Conducted
Issued 2 May 2012 Resolved
Provide training log for new employees.
Due 22 May 2012
Resolved 22 May 2012
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 2 May 2012 Resolved
Provide means to file notice to mariners and applicable chart corrections.
Due 22 May 2012
Resolved 22 May 2012
Lifesaving › Inflatable Buoyant Apparatus › Servicing
Issued 2 May 2012 Resolved
Provide copy of IBA service report (due this month).
Due 1 June 2012
Resolved 22 May 2012
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 2 May 2012 Resolved
Provide copy of fire extinguisher servicing. Two extinguishers need hydro (1 pressurized dry chem and 1 CO2).
Due 1 June 2012
Resolved 13 June 2012
Sail Rigging › Deck Hardware › Shackles
Issued 2 May 2012 Resolved
Provide mousing at main gaff throat halliards (shackles).
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 May 2012
Resolved 11 May 2012
Operations/Management › Passenger Operations › Safety Orientation
Issued 2 May 2012 Resolved
Provide means to keep passengers from bow area without rail.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 May 2012
Resolved 11 May 2012
Resolution: Roped off bow area.
Electrical › Electrical Distribution System (service) › Wiring
Issued 2 May 2012 Resolved
Secure loose wiring throughout the vessel.
Due 22 May 2012
Resolved 22 May 2012
Engineering › Bilge Water Management System › Pump
Issued 2 May 2012 Resolved
Secure bilge pumps.
Due 1 June 2012
Resolved 13 June 2012
Communications › Alarms/Indicators › Bilge Alarm
Issued 2 May 2012 Resolved
Secure bilge float switches.
Due 22 May 2012
Resolved 22 May 2012
Engineering › Bilge Water Management System › Pump
Issued 2 May 2012 Resolved
Secure engine drivin bilge pump valve handle.
Due 22 May 2012
Resolved 22 May 2012
Electrical › Electrical Distribution System (service) › Switch
Issued 2 May 2012 Resolved
Secure battery switches in engine compartment.
Due 22 May 2012
Resolved 22 May 2012
Electrical › Lighting (service) › Lighting Fixture
Issued 2 May 2012 Resolved
Install cover for light in engine compartment.
Due 22 May 2012
Resolved 22 May 2012
Resolution: Replaced entire fixture.
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 2 May 2012 Resolved
Install flame screen on fuel vents.
Due 22 May 2012
Resolved 22 May 2012
Accommodation/Occupational Safety › Cooking Systems › LPG System Requirements
Issued 2 May 2012 Resolved
Secure LPG locker and valve inside locker.
Due 22 May 2012
Resolved 11 May 2012
Resolution: Removed locker with plans to remove stove.
Electrical › Electrical Distribution System (emergency) › Wiring
Issued 2 May 2012 Resolved
Remove wire nuts from fixed fire fighting system.
Due 22 May 2012
Resolved 22 May 2012
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 2 May 2012 Resolved
Restencil life jacket stowage lockers as necessary due to weight reduction and changes in passenger count.
Due 22 May 2012
Resolved 22 May 2012
Electrical › Electric Supply System (service) › Battery Installation
Issued 2 May 2012 Resolved
Secure battery in rescue boat and provide container.
Due 22 May 2012
Resolved 22 May 2012
Construction/Loadline › Structures › Trunk
Issued 2 May 2012 Resolved
Provide proposal for addressing leak in centerboard trunk.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 May 2012
Resolution: Ladder removed indicating a leak in the two lowest plank seams in the centerboard trunk. Area recaulked and tightened with shims. Ladder will not be secured to plank as before.
Sail Rigging › Running Rigging › Topping Lifts/Attachments
Issued 2 May 2012 Resolved
Complete change-out of running rigging (topping lifts, sheet grommets). Lines wasted due to UV degredation.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 May 2012
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 2 May 2012 Resolved
Secure PFD boxes on main deck.
Due 22 May 2012
Resolved 22 May 2012
Communications › Radio Communications › EPIRB
Issued 7 July 2011 Resolved
Provide current registration for EPIRB.
Due 7 August 2011
Resolved 8 July 2011
Resolution: Proof of registration provided to the Marine Inspector.
Construction/Loadline › Hull › Hull Plating
Issued 7 July 2011 Resolved
Repair damaged plank ends aft starboard quarter by next drydock (31OCT11).
Condition: Damaged By Earlier Event
Due 31 October 2011
Resolved 20 March 2012
Engineering › Sea-water System (primary cooling) › Piping
Issued 7 July 2011 Resolved
Repair sea water strainer bolt in engine compartment.
Due 7 August 2011
Resolved 5 August 2011
Resolution: All bolts on the sea water strainer were replaced with new.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 7 July 2011 Resolved
Secure frayed ends of wire lifelines ("fish hooks")
Due 7 August 2011
Resolved 5 August 2011
Resolution: Frayed wire-rope was replaced with polypropylene lifelines.
Navigation › Piloting/Steering › Magnetic Compass
Issued 27 April 2009 Resolved
Repair magnetic compass light. No operations in reduced visibility until light is repaired.
Due 29 May 2009
Resolved 18 May 2009
Resolution: A new light was installed for the magnetic compass. Witness satisfactory operation.
Communications › Radio Communications › EPIRB
Issued 27 April 2009 Resolved
Provide EPIRB. Vessel restricted to operations within 3 NM from the baseline until registered EPIRB is provided.
Due 29 May 2009
Resolved 18 May 2009
Resolution: EPIRB was returned to the vessel from the servicing company. Verified registration, hydrostatic release, and battery dates.
Engineering › Fuel Oil Service System › Valve, Control
Issued 27 April 2009 Resolved
Repair port emergency fuel shutoff.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 April 2009
Resolution: Shutoff repaired.
Communications › Alarms/Indicators › Bilge Alarm
Issued 27 April 2009 Resolved
Repair forward high bilge alarm.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 April 2009
Resolution: Bilge alarm repaired.
Construction/Loadline › Hull › Transverse Frame
Issued 14 November 2007 Resolved
Crop out 5th port frame bad spot and fill with graving piece
Due 31 May 2008
Resolved 3 June 2008
Resolution: Sighted proper repair.
Construction/Loadline › Hull › Longitudinal Frame
Issued 14 November 2007 Resolved
Port side of the keelson install a sill beam for the inboard end of the floor board beams.
Due 31 May 2008
Resolved 3 June 2008
Resolution: Sighted individual sill beams for the floor board beams.
Construction/Loadline › Hull › Transverse Frame
Issued 14 November 2007 Resolved
Lower port futtock five frames aft of the fwd end of centerboard, crop out soft spot and fit graving piece
Due 31 May 2008
Resolved 3 June 2008
Resolution: Sighted proper repair.
Construction/Loadline › Hull › Keel
Issued 14 November 2007 Resolved
Service the centerboard shiaves on deck
Due 31 May 2008
Resolved 3 June 2008
Resolution: Sighted cleaned up sheaves
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 14 November 2007 Resolved
Replace the fore boom
Due 31 May 2008
Resolved 3 June 2008
Resolution: Sighted new boom.
Construction/Loadline › Hull › Stiffener
Issued 14 November 2007 Resolved
Renew the graving piece in the port covering board four tip timbers aft of the aft foremast chain
Due 31 May 2008
Resolved 3 June 2008
Resolution: Sighted proper repair
Construction/Loadline › Hull › Longitudinal Frame
Issued 14 November 2007 Resolved
Replace the middle starboard bulwark plank at the hawse forward of the main forward stay.
Due 31 May 2008
Resolved 3 June 2008
Resolution: Sighted proper repair.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 12 April 2007 Resolved
Conduct fire and man overboard drills in presence of a CG inspector.
Action required: 705 - Other - as specified
Due 12 May 2007
Resolved 2 May 2007
Resolution: Drills conducted.
Engineering › Bilge Water Management System › Interface Detector
Issued 21 April 2006 Resolved
Needs to mount bilge alarm float switch.
Due 7 May 2006
Resolved 26 April 2006
Resolution: Bilge float switch has been mounted
Engineering › Fuel Oil Service System › Suction Strainer
Issued 14 March 2006 Resolved
USCG marine inspector to conduct inspection of approved modification to fuel filter/water separator.
Condition: Placed in Improper Service
Due 14 April 2006
Resolved 21 April 2006
Resolution: Installed new raycor filter.
Electrical
Issued 2 April 2004 Resolved
Reattach shaft log bonding wire to bottom plate. LEGACY COMPONENT DESC: Bonding wire
Condition: Unknown
Due 8 June 2004
Resolved 17 June 2004
Resolution: Complete.
Accommodation/Occupational Safety › Ventilation
Issued 2 April 2004 Resolved
Provide means of closing natural vent from E/R during machinery space fire. LEGACY COMPONENT DESC: Engine Room
Due 8 June 2004
Resolved 17 June 2004
Resolution: Complete.
Accommodation/Occupational Safety › Medical/First Aid
Issued 2 April 2004 Resolved
Provide aspirin & eyewash for first aid kit. LEGACY COMPONENT DESC: Medicine Chest
Condition: Improper/Lack of Maintenance
Due 8 June 2004
Resolved 17 June 2004
Resolution: Complete.
Navigation › Piloting/Steering
Issued 2 April 2004 Resolved
Provide current compass deviation table. LEGACY COMPONENT DESC: Compass Deviation Table
Condition: Unknown
Due 8 June 2004
Resolved 17 June 2004
Resolution: Complete.
Engineering › Bilge Water Management System
Issued 2 April 2004 Resolved
Prove proper "auto" function of aft bilge pump. LEGACY COMPONENT DESC: Pump
Condition: Unknown
Due 8 June 2004
Resolved 17 June 2004
Resolution: Test sat.
Electrical › Electrical Distribution System (emergency)
Issued 23 May 2002 Resolved
Properly splice wires pertaining to bilge pump & float switch located aft of centerboard case. LEGACY COMPONENT DESC: Wiring
Condition: Improper/Lack of Maintenance
Due 6 June 2002
Resolved 21 June 2002
Electrical › Electrical Distribution System (service)
Issued 23 May 2002 Resolved
properly support (hang) wires in Lazz. LEGACY COMPONENT DESC: Wiring
Condition: Improper/Lack of Maintenance
Due 13 June 2002
Resolved 21 June 2002
Electrical › Electrical Distribution System (service)
Issued 23 May 2002 Resolved
Remove dead-ended wires IWO Port Running Light deck penetration. LEGACY COMPONENT DESC: Wiring
Condition: Improper/Lack of Maintenance
Due 6 June 2002
Resolved 21 June 2002
Electrical › Electrical Distribution System (service)
Issued 23 May 2002 Resolved
Properly splice Port & Stbd side running lights wires. LEGACY COMPONENT DESC: Wiring
Condition: Improper Installation
Due 13 June 2002
Resolved 21 June 2002
Stability › Watertight Integrity
Issued 23 May 2002 Resolved
Monitor Centerboard Case leak every 1/2 hour while U/W & log in Ships Log. Until proper repairs are completed (06June02). LEGACY COMPONENT DESC: Centerboard Case
Condition: Unknown
Due 6 June 2002
Resolved 3 June 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 23 May 2002 Resolved
Do not use current Centerboard Down-Haul. Appropriatly re-enforce to the satisfaction of Marine Inspector prior to use use of new system. LEGACY COMPONENT DESC: Centerboard Down-Haul
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 May 2002
Resolved 28 May 2002
Accommodation/Occupational Safety › Occupational Safety
Issued 23 May 2002 Resolved
Tighten Life-lines and Mouse related Shackles. LEGACY COMPONENT DESC: Deck Rail
Condition: Improper/Lack of Maintenance
Due 6 June 2002
Resolved 21 June 2002
Fire Fighting › Miscellaneous Items
Issued 23 May 2002 Resolved
Add name to Fire ax LEGACY COMPONENT DESC: Fire ax
Condition: Improper/Lack of Maintenance
Due 13 June 2002
Resolved 21 June 2002
Fire Fighting › Fire Hydrants
Issued 23 May 2002 Resolved
Place Spanners for Fire Hose Near hose station.
Condition: Unknown
Due 13 June 2002
Resolved 24 July 2002
Lifesaving › Lifejacket/PFD (General)
Issued 23 May 2002 Resolved
Replace 06 Child & 06 Adult Life Jackets. Passenger count to reflect amount of Jackets onboard until replaced. LEGACY COMPONENT DESC: Condition
Condition: Improper Installation
Due 6 June 2002
Resolved 21 June 2002
Construction/Loadline › Hull
Issued 7 February 2002 Resolved
Vessel new sink drain thru-hull to be inspected as per submitted fax. LEGACY COMPONENT DESC: Hull Plating
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 April 2002
Resolution: Attended vessel on the beach at Norwalk Cove Marine, sighted installation of sink drain and valve-Sat
Accommodation/Occupational Safety
Issued 27 April 2001 Resolved
Provide protection for exposed electrical connections on back of gas control panel.
Condition: Unknown
Due 3 December 2001
Resolved 3 December 2001
Lifesaving
Issued 26 April 2001 Resolved
Properly secure reefer to deck/bulkheads.
Condition: Unknown
Due 26 April 2001
Resolved 26 April 2001
Lifesaving
Issued 26 April 2001 Resolved
Replace plastic trash cans with Non-flam type.
Condition: Unknown
Due 26 April 2001
Resolved 26 April 2001
Lifesaving
Issued 26 April 2001 Resolved
Properly secure wires in ovhd of berthing area on port side.
Condition: Unknown
Due 26 April 2001
Resolved 26 April 2001
Lifesaving
Issued 26 April 2001 Resolved
Properly secure all life jacket containers on deck.
Condition: Unknown
Due 26 April 2001
Resolved 26 April 2001
Fire Fighting
Issued 10 May 1999 Resolved
CONDUCT INSTALLATION INSPECTION AND TESTS FOR PRE-ENGINEERED HALON SYSTEM.
Condition: Unknown
Due 10 May 1999
Resolved 10 May 1999
Electrical
Issued 9 April 1999 Resolved
Remove spliced wires, remove/replace plastic cable anchors- throughout the vessel.
Condition: Unknown
Due 9 May 1999
Resolved 17 August 1999
Electrical
Issued 9 April 1999 Resolved
Make wiring connections at boxes in a workmanlike manner- throughout.
Condition: Unknown
Due 9 May 1999
Resolved 17 August 1999
Lifesaving
Issued 9 April 1999 Resolved
Provide divider between adult & child life jackets- fwd locker stbd side.
Condition: Unknown
Due 9 May 1999
Resolved 17 August 1999
Accommodation/Occupational Safety
Issued 9 April 1999 Resolved
Double clamp hoses in cht system.
Condition: Unknown
Due 9 May 1999
Resolved 17 August 1999
Accommodation/Occupational Safety
Issued 9 April 1999 Resolved
Provide means to lock CHT ovbd discharge.
Condition: Unknown
Due 9 May 1999
Resolved 17 August 1999
Engineering
Issued 9 April 1999 Resolved
Double clamp MDE exhaust fittings.
Condition: Unknown
Due 9 May 1999
Resolved 17 August 1999
Electrical
Issued 9 April 1999 Resolved
Remove dead-ended wires in way of main electrical panel over main engine.
Condition: Unknown
Due 9 May 1999
Resolved 17 August 1999
Engineering
Issued 9 April 1999 Resolved
Make proper repairs to main engine throttle control cable.
Condition: Unknown
Due 9 May 1999
Resolved 17 August 1999
Navigation
Issued 22 April 1998 Resolved
PROVIDE AN UPDATED COAST PILOT.
Condition: Unknown
Due 22 April 1998
Resolved 22 April 1998
Lifesaving
Issued 22 April 1998 Resolved
RELABEL ONE LIFEJACKET STOWAGE AREA TO REFLECT CORRECT NUMBER OF LIFEJACKETS. LABEL OPEN STOWAGE AREA FOR LIFEJACKETS BELOW DECK.
Condition: Unknown
Due 22 April 1998
Resolved 22 April 1998
Lifesaving
Issued 16 April 1997 Resolved
PROVIDE WATERLIGHT FOR LIFE FLOAT.
Condition: Unknown
Due 16 May 1997
Resolved 22 April 1997
Lifesaving
Issued 16 April 1997 Resolved
PROVIDE 406MHZ, CATEGORY 1 EPIRB BEFORE SAILING ON COASTWISE ROUTE. VESSEL IS LIMITED TO LAKES BAYS AND SOUNDS ROUTE UNTIL EPIRB PROVIDED.
Condition: Unknown
Due 16 April 1997
Resolved 16 April 1997
Lifesaving
Issued 16 April 1997 Resolved
PROVIDE PROPER NETTING ON LIFE FLOAT.
Condition: Unknown
Due 16 May 1997
Resolved 22 April 1997
Construction/Loadline
Issued 20 October 1992 Resolved
EXTENSION OF DRYDOCK IS GRANTED AND VESSEL IS TO BE DRYDOCKED FOR CREDIT NOT LATER THAN 30 APRIL 1993.
Condition: Unknown
Due 20 October 1992
Resolved 20 October 1992
Lifesaving
Issued 9 July 1992 Resolved
PROVIDE 9 ADULT LIFE PRESERVERS, TYPE I CG APPROVED. VESSEL IS RESTRICTED TO 43 TOTAL PERSONS UNTIL SATISFACTORY COMPLETION OF THIS REQUIREMENT.
Condition: Unknown
Due 11 August 1992
Resolved 11 August 1992
Lifesaving
Issued 28 April 1992 Resolved
PROVIDE 9 ADULT LIFE PRESERVERS, TYPE I CG APPROVED. VESSEL IS RESTRICTED TO 43 TOTAL PERSONS UNTIL SATISFACTORY COMPLETION OF THIS REQUIREMENT.
Condition: Unknown
Due 28 April 1992
Resolved 28 April 1992
Lifesaving
Issued 2 May 1990 Resolved
PROVIDE APPROVED WEAKLINK TO SECURE BUOYANT APPARATUS TO DECK OF VESSEL
Condition: Unknown
Due 2 May 1990
Resolved 2 May 1990
Lifesaving
Issued 2 May 1990 Resolved
PROVIDE ONE USCG-APPROVED WATERLIGHT FOR RING BUOY
Condition: Unknown
Due 2 May 1990
Resolved 2 May 1990
Engineering
Issued 23 June 1987 Resolved
IN ACCORDANCE WITH 46 CFR 182.20-40 MAKE THE EMERGENCY FUEL SHUT OFF ACCESSIBLE FROM THE WEATHER DECK.
Condition: Unknown
Due 23 June 1987
Resolved 23 June 1987
Lifesaving
Issued 23 June 1987 Resolved
IN ACCORDANCE WITH 46 CFR 183.35-10 PROVIDE A WATERTIGHT CONTAINER FOR STORAGE OF THE PYROTECHNIC DEVICES.
Condition: Unknown
Due 23 June 1987
Resolved 23 June 1987
Accommodation/Occupational Safety
Issued 23 June 1987 Resolved
REPLACE THE MSD DISCHARGE HOSE AND ENSURE THAT THE NEW HOSE IS DOUBLE CLAMPED TO THE SEA VALVE.
Condition: Unknown
Due 23 June 1987
Resolved 23 June 1987
Electrical
Issued 23 June 1987 Resolved
IN ACCORDANCE WITH 46 CFR 183.05 SECURE ALL WIRING TO THE OVERHEAD AND OR BULKHEADS TO PROTECT IT FROM CHAFFING AND ACCIDENTAL BREAKING.
Condition: Unknown
Due 23 June 1987
Resolved 23 June 1987
Engineering
Issued 23 June 1987 Resolved
IN ACCORDANCE WITH 46 CFR 185.30-20 MARK THE EMERGENCY FUEL SHUT OFF.
Condition: Unknown
Due 23 June 1987
Resolved 23 June 1987

Casualty record · 3

21 June 2013Routine · role: Involved in a Marine Casualty · activity 4629957
2 October 2020Routine · role: Involved in a Marine Casualty · activity 7071770
8 October 2023Routine · role: Involved in a Marine Casualty · activity 7806774
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

QUINNIPIACK (2013). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.