SS MISS BELMAR

SS MISS BELMAR is a 1984 passenger vessel (inspected). The Coast Guard has recorded 75 inspections since 1984, most recently in July 2026, along with 74 deficiencies.

Records from 1984 to 2026. Most recent: inspection, 1 July 2026.

Built
1984
Last inspected
1 July 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDL5982
229403
Flag
UNITED STATES
368146270
Maury page id
psix-229403

Inspections, by type

…with no type recorded7
Years with a record 39 calendar years (1984–2026)
The 75 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)86.5 ft × 25.5 ft × 8.3 ft
Registered tonnagegross 98 / net 66
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGULF CRAFT · PATTERSON, LA, UNITED STATES · built 1984
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portBELMAR, NJ
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 30 January 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it98 - Regulatory (Subpart C or D), Gross Ton
66 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDP4546MMSI 368146270 · active · compulsorily equipped · granted 1 March 2024, expires 1 March 2034
WDP4522MMSI 368146270 · active · compulsorily equipped · granted 29 February 2024, expires 28 February 2034
WDL5982MMSI 368146270 · cancelled · compulsorily equipped · granted 23 May 2020, cancelled 9 February 2024 · licensed under a name not among this hull’s recorded names (not shown)
WDC8574MMSI 367089480 · expired · compulsorily equipped · granted 7 January 2016, cancelled 4 April 2026 · licensed under a name not among this hull’s recorded names (not shown)
WCW4196MMSI not assigned · expired · compulsorily equipped · granted 10 April 1996, cancelled 10 June 2006 · licensed under a name not among this hull’s recorded names (not shown)
WSV9141MMSI not assigned · expired · compulsorily equipped · granted 19 April 1994, cancelled 6 June 2004 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 75

1 July 2026 In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8420281
6 May 2026 Annual Inspection · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8343759
7 April 2026 Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8319042
25 March 2025 Internal Structural Exam · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 8097499
4 June 2024 Deficiency Check
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7926998
2 May 2024 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7905104
22 February 2024 Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7868384
2 August 2023 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7758796
8 May 2023 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7684284
16 February 2023 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7637642
11 October 2022 Hull Examination · Examination of Repairs
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7575693
13 April 2022 COI Inspection · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7430021
20 March 2022 Type not recorded
No type recorded · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7415177
28 June 2021 Administrative Inspection · Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7282139
19 January 2021 Deficiency Check · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 7127743
1 June 2020 Annual Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6965355
30 April 2020 Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6946133
8 May 2019 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6684558
1 May 2019 Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6674923
12 April 2018 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6390453
30 October 2017 Deficiency Check · Administrative Inspection
Physical examination · Navigation Center · Activity 6297760
18 April 2017 COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6127651
24 April 2016 Type not recorded
No type recorded · Station New York · USCG Northeast District (CGD-NE) · Activity 5861661
13 April 2016 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5853096
13 October 2015 Type not recorded
No type recorded · Station Jones Beach · USCG Northeast District (CGD-NE) · Activity 5746719
2 December 2011 Administrative Inspection
Administrative · Sector New York · USCG Northeast District (CGD-NE) · Activity 4200337
16 April 2009 Deficiency Check · MTSA Verification · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3453227
18 April 2008 Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3187276
12 September 2007 Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 3056484
18 April 2007 COI Inspection · MARPOL Annex V Examination · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2911448
14 April 2006 Annual Inspection · MARPOL Annex V Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2624828
9 December 2005 Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2548645
5 April 2005 Annual Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2326697
27 October 2004 Hull Examination · Internal Structural Exam · Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2229623
23 October 2004 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2229651
8 April 2004 MARPOL Annex V Examination · Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2039835
10 April 2003 Deficiency Check · Annual Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1771314
10 December 2002 Hull Examination · Drydock Extension · Internal Structural Exam · Examination of Repairs
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1728589
20 November 2002 Damage Survey
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1709727
3 April 2002 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1600736
18 May 2001 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1457937
9 April 2001 Re-Inspection · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1420491
26 April 2000 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1423361
5 April 1999 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1365131
10 December 1998 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 805867
20 April 1998 Re-Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 789034
9 April 1997 MARPOL Annex V Examination · Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1103184
24 February 1997 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1096066
7 November 1996 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1170228
8 October 1996 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1149328
18 September 1996 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1458341
12 April 1996 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1080516
4 May 1995 Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1027973
29 March 1995 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1144348
20 March 1995 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 833715
20 April 1994 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1353555
10 May 1993 Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 838173
20 April 1993 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1462341
8 April 1993 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1462340
23 April 1992 Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 954131
31 March 1992 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1260726
19 February 1992 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1263748
11 April 1991 Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 930429
28 March 1991 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1218401
7 March 1991 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1215126
24 April 1990 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 910007
29 March 1990 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 921162
25 April 1989 COI Inspection · Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 898826
7 February 1989 Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1338647
1 April 1988 COI Inspection · Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 992220
21 April 1987 COI Inspection · Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1317920
8 April 1986 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1306662
29 March 1985 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1290415
19 March 1985 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1288626
19 April 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 973495

Deficiency record · 74

11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 25 March 2025 Resolved
Each disposable hydrostatic release unit must be marked w/an expiration date of two years after the date installed. EPIRB disposable hydrostatic release unit is expired. 46 CFR 185.740(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 April 2025
Resolved 31 March 2025
Resolution: Recieved picture of newly purchased EPIRB HRU.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 25 March 2025 Resolved
Vessels described by 46 CFR 175.110(c) must have an interconnected fire detection system in compliance with §181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces. Vessel did not have smoke detector at operating station. 46 CFR 181.405(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 April 2025
Resolved 2 April 2025
Resolution: New interconnected smoke detector placed at operating station and succesfuly tested.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 March 2025 Resolved
Except as provided otherwise in this subpart, all electrical equipment including motors, generators, controllers, distribution panels, etc., shall be drip-proof protected. The switchboard voltmeter and breaker panel were missing coverings. 46 CFR 183.10-10 (Old T)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 April 2025
Resolved 3 April 2025
Resolution: Voltmeter and switchboard panel have proper covering.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 25 March 2025 Resolved
The construction & arrangement of a vsl must allow the safe operation of the vsl in accordance w/ the terms of its COI. The starboard support beam in the fwd storage compartment has become detached at the deck. Submit repair proposal and correct. 46 CFR 177.100
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 April 2025
Resolved 2 April 2025
Resolution: Stanchion was gouged and properly welded to the deck.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 2 May 2024 Resolved
All vessels shall be provided with not less than two avenues of escape from all general areas accessible to the passengers or where the crew may be quartered or normally employed. Escape hatch was found broken, severely corroded and unable to open from inside the engine room space. Replace/repair escape hatch for engine room. 46 CFR 177.15-1
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 May 2024
Resolved 3 May 2024
Resolution: O/O sent photo evidence of satisfactory repair.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 2 May 2024 Resolved
Except as provided otherwise in this subpart, all electrical equipment including motors, generators, controllers, distribution panels, etc., shall be dripproof protected...so constructed or protected that its successful operation is not interfered with when subjected to falling moisture or dirt, and rotating or uninsulated parts cannot be inadvertently touched... Voltmeter for Generator #2 was exposed/uncovered; cover. 46 CFR 183.10-10(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 May 2024
Resolved 4 June 2024
Resolution: Recieved pictures showing replacement of gauge
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 2 May 2024 Resolved
On a vessel on which the number of passengers permitted on upper decks is limited by stability criteria, as indicated by the vessel's stability letter, the maximum number of passengers allowed on an upper deck must be indicated by a durable marking of at least 25 millimeters (1 inch) numbers and letters at the entranceway to that deck. Vessels upper deck was not labeled with max pax count. 46 CFR 185.602(g)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 May 2024
Resolved 4 June 2024
Resolution: recieved pictures showing upper deck label.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 8 May 2023 Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. Found cracked Amp meter on generator distribution panel on aft bulkhead in engine room. Replace/repair broken Amp meter. 46 CFR 183.01-15 old "T"
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2023
Resolved 11 October 2023
Resolution: O/O provided picture of replaced amp meter
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 8 May 2023 Resolved
All vessels shall be provided with not less than two avenues of escape from all general areas accessible to the passengers or where the crew may be quartered or normally employed. Escape hatch was found broken, severely corroded and unable to open from inside the engine room space. Replace/repair escape hatch for engine room. 46 CFR 177.15-1 Old "T"
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2023
Resolved 11 October 2023
Resolution: O/O provided video of repaired emergency espcape hatch in use.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 13 April 2022 Resolved
No guards were protecting alternator belts on all 03 main engines. 46 CFR 177.35-15(Old T)
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 May 2022
Resolved 27 April 2022
Resolution: Received photographic satisfactory evidence of repair.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 13 April 2022 Resolved
Lifefloat grabline's were secured using zipties. Replace is material that is easily broken when pulled. 46 CFR 180.175(d)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 April 2022
Resolved 27 April 2022
Resolution: Received photographic satisfactory evidence of repair.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 April 2022 Resolved
Secure dead end wires behind operating station. 46 CFR 183.05-50(b) (Old T)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 April 2022
Resolved 27 April 2022
Resolution: Received photographic satisfactory evidence of repair.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 28 June 2021 Resolved
IBA onboard was not attached to the vessel by weak link. This was corrected prior to the end of the inspection.
Action required: 17 - Rectify deficiencies prior to departure
Due 28 June 2021
Resolved 28 June 2021
Resolution: Corrected prior to the end of the inspection.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 19 January 2021 Resolved
Hydro pneumatic tank in the workshop is currently secured with bungees. Provide permanent means of securing.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 29 January 2021
Resolution: Tank secured by aluminum bar attachment.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 19 January 2021 Resolved
Cracks identified in bulwark attachment to deck starboard side aft and in steering compartment scuttle on main deck. Repair cracks prior to credit drydock.
Action required: 705 - Other - as specified
Resolved 29 January 2021
Resolution: Cracks repaired.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 19 January 2021 Resolved
Pitting identified in steering compartment. Gauge and repair as indicated by gauging results prior to credit drydock.
Action required: 705 - Other - as specified
Resolved 25 January 2021
Resolution: Plating cropped and replaced.
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 9 June 2020 Resolved
Input lat/long position into radio
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 July 2020
Resolved 11 June 2020
Resolution: Verified lat/long input in radio.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 9 June 2020 Resolved
Label fuel shutoff valves
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 July 2020
Resolved 11 June 2020
Resolution: Fuel shutoffs labeled.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 June 2020 Resolved
Repair minor fuel leak on port engine fuel filter union
Action required: 16 - Rectify deficiencies w/in 14 days
Due 23 June 2020
Resolved 11 June 2020
Resolution: Fuel leak repaired
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 June 2020 Resolved
Remove dead end wiring, install wire hangers on aft overhead and drill .25" drainage holes in handrails every 5 ft where wire passes through.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 July 2020
Resolved 11 June 2020
Resolution: Holes drilled in handrails.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 May 2019 Resolved
A vesel must carry one floating waterlight, which must be approved IAW 46 CFR 161.010. The waterlight was not marked and Marine Inspector could not verify type approval.
Action required: 10 - Deficiency Rectified
Resolved 8 May 2019
Resolution: Lifebuoy light was replaced.
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 16 April 2009 Resolved
Make permanent repairs to crack in wet exhaust box/line, port side in lazz space.
Action required: 705 - Other - as specified
Due 16 May 2009
Resolved 23 April 2009
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 16 April 2009 Resolved
Provide FCC Bridge-to-Bridge Certificate.
Action required: 705 - Other - as specified
Due 16 May 2009
Resolved 23 April 2009
Communications › Radio Communications › EPIRB
Issued 16 April 2009 Resolved
Register EPIRB through NOAA (Vessel restricted to no more than 3 nautical miles off shore).
Action required: 705 - Other - as specified
Due 16 May 2009
Resolved 16 April 2009
Fire Fighting › Fire Hydrants › Location/Position
Issued 16 April 2009 Resolved
Stencil fire station locations.
Action required: 705 - Other - as specified
Due 16 May 2009
Resolved 23 April 2009
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 16 April 2009 Resolved
Stencil fuel shut-off location.
Action required: 705 - Other - as specified
Due 16 May 2009
Resolved 23 April 2009
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 16 April 2009 Resolved
Stencil life jacket quantity in each storage box.
Action required: 705 - Other - as specified
Due 16 May 2009
Resolved 23 April 2009
Lifesaving › Lifefloat › Serviceable
Issued 16 April 2009 Resolved
Make permanent repairs to (05) life floats, as discussed.
Action required: 705 - Other - as specified
Due 16 May 2009
Resolved 23 April 2009
Electrical › Electrical Distribution System (service) › Wiring
Issued 16 April 2009 Resolved
Remove black and beige-colored wiring IWO port generator.
Action required: 705 - Other - as specified
Due 16 May 2009
Resolved 23 April 2009
Fire Fighting › Fire Main › Condition
Issued 18 April 2008 Resolved
Repair leak on fire main union connection.
Condition: Improper/Lack of Maintenance
Due 1 May 2008
Resolved 24 April 2008
Navigation › Piloting/Steering › Coast Guard Light List
Issued 18 April 2008 Resolved
Replace missing Coast Pilot & Light List.
Condition: Unknown
Due 1 May 2008
Resolved 24 April 2008
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 18 April 2008 Resolved
Provide USCG proof of employee enrollment w/ DAPI Program.
Condition: Unknown
Due 1 May 2008
Resolved 24 April 2008
Lifesaving › Lifefloat › Paddle
Issued 18 April 2007 Resolved
Lash paddles to lifefloats IAW 46 CFR 180.175(f)(2).
Action required: 705 - Other - as specified
Due 18 May 2007
Resolved 23 April 2007
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 18 April 2007 Resolved
Provide proof of enrollement of crew in drug testing program in accordance with 46 CFR Part 16.
Action required: 705 - Other - as specified
Due 18 May 2007
Resolved 23 April 2007
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 18 April 2007 Resolved
Provide one additional child size life jacket onboard vessel. Vessel is restricted to the carriage of 15 passengers until requirement complete.
Action required: 705 - Other - as specified
Due 18 May 2007
Resolved 23 April 2007
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 8 April 2004 Resolved
Provide current navigation publications (tide tables, current tables, light lists).
Due 16 April 2004
Resolved 15 July 2004
Resolution: Curent nav pubs provided.
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 8 April 2004 Resolved
Provide current (COMDTINST M16672.2E) navigation rules (international and inland).
Due 16 April 2004
Resolved 15 July 2004
Resolution: Current Nav Rulres provided.
Electrical › Lighting (emergency)
Issued 10 April 2003 Resolved
Make proper repairs to emergency lighting. LEGACY COMPONENT DESC: Battery Operated Lantern
Condition: Improper/Lack of Maintenance
Due 16 April 2003
Resolved 15 April 2003
Operations/Management › Drills/Instruction
Issued 10 April 2003 Resolved
Post Emergency Broadcast Placard. LEGACY COMPONENT DESC: Making Voice Radio Distress Call
Condition: Improper/Lack of Maintenance
Due 16 April 2003
Resolved 10 April 2003
Lifesaving › Lifejacket/PFD (General)
Issued 10 April 2003 Resolved
Post lifejacket donning placards. LEGACY COMPONENT DESC: Storage
Condition: Improper/Lack of Maintenance
Due 10 April 2003
Resolved 15 April 2003
Accommodation/Occupational Safety › Occupational Safety
Issued 10 April 2003 Resolved
Make proper repair to portable lighting on bridge. LEGACY COMPONENT DESC: Portable Electric Equipment/Appliances
Condition: Improper/Lack of Maintenance
Due 16 April 2003
Resolved 10 April 2003
Electrical › Electric Supply System (service)
Issued 10 April 2003 Resolved
Romove battery acid or water out of stbd battery box. LEGACY COMPONENT DESC: Battery Installation
Condition: Improper/Lack of Maintenance
Due 16 April 2003
Resolved 15 April 2003
Construction/Loadline › Hull › Hull Plating
Issued 10 April 2003 Resolved
At next DD, v/w crack in hatch opening and stanchion just fwd of opening.
Condition: Improper/Lack of Maintenance
Due 31 December 2004
Resolved 27 October 2004
Resolution: Not found during this DD exam.
Lifesaving › Lifejacket/PFD (General)
Issued 10 April 2003 Resolved
Post proper placard for children's life jackets. LEGACY COMPONENT DESC: Storage
Condition: Improper/Lack of Maintenance
Due 10 April 2003
Resolved 15 April 2003
Navigation › Piloting/Steering › Magnetic Compass
Issued 3 April 2002 Resolved
Ensure magnetic compass light is operating.
Due 5 April 2002
Resolved 3 April 2002
Resolution: Light was replaced.
Navigation › Electronic Positioning
Issued 3 April 2002 Resolved
Replace hydrostatic release to EPIRB. LEGACY COMPONENT DESC: EPIRB
Due 5 April 2002
Resolved 3 April 2002
Resolution: Hydrostatic release replaced.
Lifesaving
Issued 9 April 2001 Resolved
Vessel is limited to 100 persons total until proper lights & whistles are installed.
Condition: Unknown
Due 9 April 2001
Resolved 9 April 2001
Lifesaving
Issued 9 April 2001 Resolved
Provide NOAA registration for EPIRB. Vessel must have registration prior toconducting commercial operations outside 3 miles from shore (fax copy of registration sticker).
Condition: Unknown
Due 9 April 2001
Resolved 9 April 2001
Electrical
Issued 9 April 2001 Resolved
Remove extension cords attached to 3 block heaters. Replace w/ boat cable.
Condition: Unknown
Due 9 April 2001
Resolved 9 April 2001
Electrical
Issued 26 April 2000 Resolved
submit plans for approval on the newly installed engine controls, wire, andpower panel.
Condition: Unknown
Due 18 May 2000
Resolved 18 May 2000
Engineering
Issued 5 April 1999 Resolved
Provide 30 x 30 or doubled 20 x 20 flame screens
Condition: Unknown
Due 14 April 1999
Resolved 14 April 1999
Navigation
Issued 5 April 1999 Resolved
Provide current publications, 46CFR 166-199, Coast Piolt, Tide Tables.
Condition: Unknown
Due 14 April 1999
Resolved 14 April 1999
Electrical
Issued 10 December 1998 Resolved
INSTALL FLOURESCENT LIGHT COVER STBD SIDE #3 VOID.
Condition: Unknown
Due 10 December 1998
Resolved 11 December 1998
Construction/Loadline
Issued 10 December 1998 Resolved
#2 VOID - MAKE WATERTIGHT PIPE PENETRATIONS FORWARD OVERHEAD AND WELD REMOVED SEATING BOLT HOLES IN DECK.
Condition: Unknown
Due 10 December 1998
Resolved 11 December 1998
Construction/Loadline
Issued 10 December 1998 Resolved
V/W #3 VOID GUSSET TABS IWO VERTICAL FRAMES AND DECK ROUND. ALL - (7) PORT AND (7) STBD. FULL PENETRATION BOTH SIDES.
Condition: Unknown
Due 10 December 1998
Resolved 11 December 1998
Fire Fighting
Issued 20 April 1998 Resolved
PROVE PROPER OPERATION OF THE FIRE PUMP PRESSURE GAUGE.
Condition: Unknown
Due 20 April 1998
Resolved 20 April 1998
Unknown
Issued 9 April 1997 Resolved
Post employer policy and hotline number for drug & alcohol program.
Condition: Unknown
Due 10 April 1997
Resolved 10 April 1997
Unknown
Issued 12 April 1996 Resolved
PROVIDE LOCKING DEVICE FOR MSD OVERBOARD DISCHARGE VALVE.
Condition: Unknown
Due 12 May 1996
Resolved 18 September 1996
Lifesaving
Issued 12 April 1996 Resolved
SHOW FLOAT FREE OPERAQTION OF ALL LIFE FLOATS TO THE SATISFACTION OF ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 12 May 1996
Resolved 18 September 1996
Unknown
Issued 12 April 1996 Resolved
PROVIDE AND POST STATION BILL IAW 46CFR185.514
Condition: Unknown
Due 11 March 1997
Resolved 18 September 1996
Unknown
Issued 12 April 1996 Resolved
PROVIDE AND POST EMERGENCY BROADCAST PLACARD IAW 46CFR184.506.
Condition: Unknown
Due 11 March 1997
Resolved 18 September 1996
Lifesaving
Issued 12 April 1996 Resolved
PROVIDE 100% SURVIVAL CRAFT FOR COLD WATER OPERATIONS (153 PERSONS) IAW 46CFR180.200.
Condition: Unknown
Due 18 September 1996
Resolved 18 September 1996
Fire Fighting
Issued 29 March 1995 Resolved
Repair leaks in ER fire pump piping and prove operation.
Condition: Unknown
Due 30 March 1995
Resolved 31 March 1995
Lifesaving
Issued 29 March 1995 Resolved
Conduct underway fire and person over board drills.
Condition: Unknown
Due 29 March 1995
Resolved 29 March 1995
Lifesaving
Issued 29 March 1995 Resolved
Provide outside grab line on port lower life float.
Condition: Unknown
Due 30 March 1995
Resolved 31 March 1995
Navigation
Issued 29 March 1995 Resolved
Provide # 13200, 13249, and 13246 updated charts.
Condition: Unknown
Due 30 March 1995
Resolved 31 March 1995
Lifesaving
Issued 10 May 1993 Resolved
PROVIDE SUITABLE RESCUE PLATFORM.
Condition: Unknown
Due 10 May 1993
Resolved 10 May 1993
Lifesaving
Issued 20 April 1993 Resolved
CONDUCT UNDERWAY FIRE AND MAN OVERBOARD DRILLS IN PRESENCE OF USCG MARINE INSPECTOR.
Condition: Unknown
Due 20 April 1993
Resolved 20 April 1993
Accommodation/Occupational Safety
Issued 20 April 1993 Resolved
OBTAIN AND POST ANNEX V PLACARD.
Condition: Unknown
Due 21 April 1993
Resolved 21 April 1993
Documentation
Issued 20 April 1993 Resolved
OBTAIN VALID FCC RADIO OPERATOR'S LICENSE FOR VESSEL'S OPERATOR.
Condition: Unknown
Due 20 April 1993
Resolved 20 April 1993
Lifesaving
Issued 31 March 1992 Resolved
CONDUCT UNDERWAY EMERGENCY DRILLS IN THE PRESENCE OF A CG MARINE INSPECTOR.
Condition: Unknown
Due 31 March 1992
Resolved 31 March 1992
Accommodation/Occupational Safety
Issued 19 April 1984 Resolved
THE OIL FIRED FURNANCE ABOARD SHALL NOT BE OPERATED UNTIL TEST DATA IS PROVIDED SHOWING FURNANCE MEETS MARINE STANDARDS AS SET FORTH IN
Condition: Unknown
Due 19 April 1984
Resolved 19 April 1984
Unknown
Issued 19 April 1984 Resolved
THE FOLLOWING DEFICIENCY PERTAIN TO THE VESSEL DOLPHIN V, DN668477.
Condition: Unknown
Due 19 April 1984
Resolved 19 April 1984
Accommodation/Occupational Safety
Issued 19 April 1984 Resolved
(REQUIREMENT 1 CONTINUED) 46 CFR 63.10-15.
Condition: Unknown
Due 19 April 1984
Resolved 19 April 1984

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.