Records from 1985 to 2026. Most recent: inspection, 10 August 2026.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 60
10 August 2026
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8460899
1 July 2026
Annual Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8426055
16 July 2025
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8187814
23 April 2025
Internal Structural Exam · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8120127
5 July 2024
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7949431
5 July 2023
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7735032
18 May 2022
Internal Structural Exam · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7457174
20 April 2022
COI Inspection · Administrative Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7394384
29 October 2021
Administrative Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7342071
7 July 2021
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7247313
2 April 2021
Administrative Inspection · In-Service Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7249670
5 August 2020
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7025703
26 December 2019
Construction Oversight
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6884830
2 July 2019
Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6742234
21 May 2019
Internal Structural Exam · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6689306
3 July 2018
Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6469234
14 April 2017
DAPI Audit · COI Inspection · Administrative Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6124540
5 July 2016
DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5932416
25 May 2016
Drydock Exam · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5887652
29 April 2016
Type not recorded
No type recorded · Station St Inigoes · USCG East District (CGD-E) · Activity 5866082
28 July 2015
Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5192265
13 August 2014
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4953404
7 July 2011
Internal Structural Exam · DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4077507
14 July 2008
Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3267804
6 July 2007
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2985538
3 May 2007
COI Inspection · Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2913927
1 May 2007
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2919792
18 July 2006
Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2720154
26 July 2005
Periodic Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2440620
11 May 2005
Periodic Inspection · Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2404930
2 July 2004
Periodic Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2118544
27 April 2004
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2053702
29 May 2003
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1821699
21 May 2002
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1619484
6 May 2002
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1610543
31 May 2001
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1399632
20 June 2000
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 823430
17 May 2000
Re-Inspection · Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1410350
4 May 1999
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1131928
3 May 1999
Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 793415
15 May 1998
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 793991
28 July 1997
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 781241
4 June 1997
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1368314
28 May 1997
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1402491
6 May 1996
Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1088154
2 May 1996
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1083242
2 May 1995
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1465831
24 May 1994
Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1168283
17 May 1994
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1173690
27 April 1993
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1136397
29 April 1992
Hull Examination · Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1264709
2 May 1991
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 914832
2 April 1991
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1224025
2 May 1990
Drydock Extension · COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 911545
1 June 1989
Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1352520
4 May 1989
Drydock Extension · Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1196921
21 May 1988
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 888022
6 May 1987
Hull Examination · COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1028849
20 May 1986
Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 994064
14 May 1985
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 983865
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 1 July 2026
Resolved
13104 - A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. The bilge indicator for the automatic bilge pump was inoperable.
46 CFR 182.530(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 August 2026
Resolution: Witnessed proper operation of the bilge indicator light.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 1 July 2026
Resolved
04108 - The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. The vessel did not have emergency instructions on board.
46 CFR 185.510(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 July 2026
Resolution: Received photographic evidence of the emergency instructions.
01 - Certificates & Documentation › 013 - Documents › Garbage record book
Issued 1 July 2026
Resolved
01320 - A vessel must comply with the applicable design, equipment, personnel, procedures, and record requirements of 33 CFR parts 151, 155, and 156. The vessel's garbage placard was deteriorated.
46 CFR 184.702
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 July 2026
Resolution: Received photographic evidence of a new garbage placard.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 July 2021
Resolved
The minimum number of portable fire extinguishers required on a vessel must not be fewer than the minimum number required by Table 181.500(b). Vessel was missing 2-A rated extinguisher from forward berth and 40-B:C extinguisher from adjacent machinery space.
46 CFR 181.500
Table 181.500(b)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 July 2021
Resolution: Vessel installed new 2-A fire extinguisher in forward berth and relocated 4-A:60-B:C extinguisher to adjacent machinery space.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 July 2021
Resolved
Shutoff valves shall be fitted in the fuel supply lines, one at the fuel tank connection. Shutoff valve at fuel tank had wasted handle. Replace in kind.
46 CFR 182.115
Old "T" 182.20-40(b)(3)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 July 2021
Resolution: Shutoff valve handle replaced in kind.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 July 2021
Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 1" high indicating purpose of the valve and direction of operation. Required markings were missing at time of inspection.
46 CFR 185.608
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 July 2021
Resolution: New fuel shutoff valve stencil placed adjacent remote fuel shutoff valve at fuel tank.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 7 July 2021
Resolved
Each vessel constructed of a material other than wood certificated on a lakes, bays, and sounds route in cold water must be provided with life floats for at least 50% of the total number of persons permitted onboard. Vessel's STBD buoyant apparatus did not have an approval plate and no weak link was employed connecting buoyant
apparatus painter to deck. Vessel must have approved
life floats properly rigged to accommodate 50% total POB
by cold water months, beginning November 1.
46 CFR 180.207(b)
Action required: 705 - Other - as specified
Due 1 November 2021
Resolved 29 October 2021
Resolution: Received photographic evidence from vessel rep [name withheld] confirming new 8-person lifefloat properly installed in place of STBD buoyant apparatus.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 7 July 2021
Resolved
Portable fire extinguishers shall be installed to the satisfaction of the [name withheld] extinguishers were not installed with appropriate marine-type mounts. Replace in kind.
46 CFR 181.115
Old "T" 131.30-10
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 July 2021
Resolved 8 July 2021
Resolution: All of vessel's 3 fire extinguishers now installed with appropriate marine-type mounts.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 28 July 2015
Resolved
Vessels Mast head light was inoperable. Issued CG-835 to repair or replace mast head light
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 July 2015
Resolution: vessel corrected inoperable masthead light on the spot. Light wire connections had a build up of corrsion on the connections.
Engineering › Bilge Water Management System › Pump
Issued 28 July 2015
Resolved
Vessels automatic electric bilge and float switch was inoperable in the automatic and manual mode.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 30 July 2015
Resolution: Vessel operator made repairs to electric bilge and attending Marine Inspector verified that bilge pump was in proper working order.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 28 July 2015
Resolved
Removed (04) defective kapok adult life jackets, passenger allowed onboard reduced to 44 until replacement of (04) for a total of 48 as per vessels COI.
Due 11 August 2015
Resolved 30 July 2015
Resolution: Verified (04) new type I adult PFD''s had been acquired and labeled as required. Passenger count allowed on board raised back to 48 per vessels COI.
Fire Fighting › Portable CO2 Fire Extinguisher › Number
Issued 7 July 2011
Resolved
Vessel missing one (1) BII fire extinguisher. Provide as new and mount on the vessel.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 July 2011
Resolution: New BII Fire Extinguisher purchased & installed to the satisfaction of the CG marine inspector.
Lifesaving › Buoyant Apparatus › Lifeline
Issued 7 July 2011
Resolved
Grab lines on port side buoyant apparatus wasted, replace as new.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 July 2011
Resolution: New grab lines purchased & installed to the satisfaction of the CG marine inspector.
Fire Fighting › Portable CO2 Fire Extinguisher › Approval
Issued 3 May 2007
Resolved
Heat sensor in engine compartment cannot be tested, does not meet requirements for an electrically supervised fire detection system. Must install approved fire detection system or be able to test heat sensor.
Action required: 705 - Other - as specified
Due 31 July 2007
Resolved 4 June 2008
Resolution: Pre-engineered Fireboy system installed for engine compartment protection.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 1 May 2007
Resolved
Failure to make vsl available prior to COI expiration date of May 06, 2007.
Action required: 705 - Other - as specified
Due 1 May 2007
Resolved 11 October 2007
Resolution: Isuued LOW in seprate activity
Lifesaving › Buoyant Apparatus › Lifeline
Issued 26 July 2005
Resolved
Reconfigure lanyard and painter on the buoyant apparatus as so they can be lowered independently pf each other.
Action required: 705 - Other - as specified
Due 4 August 2005
Resolved 30 August 2005
Electrical › Lighting (service) › Outlet Box
Issued 26 July 2005
Resolved
Permanently mount deck light into overhead aft of steering station.
Action required: 705 - Other - as specified
Due 4 August 2005
Resolved 30 August 2005
Lifesaving › Lifejacket/PFD (Type I)
Issued 29 May 2003
Resolved
RENEW RETRO-REFLECTIVE TAPE ON 4 SELECTED CHILD PFD'S. LEGACY COMPONENT DESC: Retroreflective Material
Action required: 705 - Other - as specified
Due 29 June 2003
Resolved 10 September 2003
Resolution: Corrected.
Lifesaving › Buoyant Apparatus
Issued 29 May 2003
Resolved
LABEL BOTH BUOYANT APPARATUS WITH VESSEL NAME AND CAPACITY.
Action required: 705 - Other - as specified
Due 29 June 2003
Resolved 10 September 2003
Resolution: Life float labled.
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 6 May 2002
Resolved
SERVICE FIXED AND PORTABLE FIRE EXTINGUISHERS. ITEM TO BE COMPLETED PRIOR TO CARRYING PASSENGERS AND BY 07 MAY 02. LEGACY COMPONENT DESC: Service
Due 7 May 2002
Resolved 7 May 2002
Lifesaving
Issued 31 May 2001
Resolved
PROPERLY SECURE SEAPAINTER TO THE BODY OF THE BUOYANT APPARATUS.
Condition: Unknown
Due 4 June 2001
Resolved 4 June 2001
Lifesaving
Issued 31 May 2001
Resolved
PROVIDE WATERLIGHT FOR BUOYANT APPARATUS LOCATED ON PORT SIDE.
Condition: Unknown
Due 4 June 2001
Resolved 4 June 2001
Lifesaving
Issued 31 May 2001
Resolved
PROPERLY ARRANGE SEA PAINTER FOR BOTH B.A.s.
Condition: Unknown
Due 4 June 2001
Resolved 4 June 2001
Construction/Loadline
Issued 17 May 2000
Resolved
REPAIR CRACKED STBD FWD FRAME #3 FROM STEM.
Condition: Unknown
Due 17 June 2000
Resolved 28 June 2000
Engineering
Issued 17 May 2000
Resolved
RENEW STUFFING BOX CLAMPS
Condition: Unknown
Due 17 June 2000
Resolved 11 July 2000
Fire Fighting
Issued 4 May 1999
Resolved
INSTALL FIXED FIRE FIGHTING SYSTEM.
Condition: Unknown
Due 4 May 1999
Resolved 4 May 1999
Navigation
Issued 15 May 1998
Resolved
REWIRE COMPASS LIGHT SO LIGHT OPERATIONAL. LIMITED TO DAYLIGHT OPERATIONS W/PASSENGERS UNTIL REPAIRED.
Condition: Unknown
Due 30 May 1998
Resolved 2 July 1998
Lifesaving
Issued 4 June 1997
Resolved
B/A WATER LIGHT NOT ATTACHED TO B/A._x001C_
Condition: Unknown
Due 25 June 1997
Resolved 14 July 1997
Fire Fighting
Issued 4 June 1997
Resolved
(2) B-II PORTABLE EXTINGUISHERS PITTED AND CORRODED._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 25 June 1997
Resolved 14 July 1997
Fire Fighting
Issued 4 June 1997
Resolved
(2) B-II PORTABLE FIRE EXTINGUISHERS PITTED AND CORRODED.
Condition: Unknown
Due 4 June 1997
Resolved 4 June 1997
Navigation
Issued 2 May 1995
Resolved
FIX/REPAIR STERN LIGHT.
Condition: Unknown
Due 1 November 1995
Resolved 13 December 1995
Electrical
Issued 2 May 1995
Resolved
REPLACE WING NUTS WITH HEX TYPE NUTS ON THE BATERIES.
Condition: Unknown
Due 1 November 1995
Resolved 13 December 1995
Construction/Loadline
Issued 2 May 1995
Resolved
INSTALL HIGH BILGE ALARMS IAW 46 CFR 182.530
Condition: Unknown
Due 2 May 1995
Resolved 2 May 1995
Navigation
Issued 2 May 1995
Resolved
MOUNT BELL.
Condition: Unknown
Due 1 November 1995
Resolved 13 December 1995
Navigation
Issued 2 May 1995
Resolved
OBTAIN CURRENT RULES OF THE ROAD.
Condition: Unknown
Due 1 November 1995
Resolved 13 December 1995
Navigation
Issued 2 May 1995
Resolved
OBTAIN CURRENT COAST PILOT.
Condition: Unknown
Due 1 November 1995
Resolved 13 December 1995
Navigation
Issued 2 May 1990
Resolved
REBUSH OR REPLACE FUDDER TILLER ARM
Condition: Unknown
Due 2 May 1990
Resolved 2 May 1990
Lifesaving
Issued 4 May 1989
Resolved
PROVIDE AND INSTALL APPROVED WEAK LINK OF APPROPRIATE BREAKING STRENGTH FOR BOUYANT APPARATUS
Condition: Unknown
Due 4 May 1989
Resolved 4 May 1989
Lifesaving
Issued 4 May 1989
Resolved
BRACE PFD STORAGE BOX AND BAIL TANK TO PREVENT MOVEMENT ALONG DECK ACTUAL COMPLIANCE DATE FOR ABOVE REQUIREMENTS: 24MAY89
Condition: Unknown
Due 4 May 1989
Resolved 4 May 1989
Lifesaving
Issued 21 May 1988
Resolved
PRIOR TO CARRYING PASSENGERS, BUT NO LATER THAN 1JUN88, RENEW GRAB LINES ONBOTH SEVEN PERSON BUOYANT APPARTUS.
Condition: Unknown
Due 21 May 1988
Resolved 21 May 1988
Unknown
Issued 6 May 1987
Resolved
PROVIDE CAPTIVE CHAINS, HINGES OR OTHER RETAINING DEVICES FOR ALL HATCHES/DECK COVERINGS.
Condition: Unknown
Due 6 May 1987
Resolved 6 May 1987
Unknown
Issued 6 May 1987
Resolved
PROPERLY WIRE ELECTRICAL BILGE PUMP WIRING SO AS TO ELIMINATE WIRE NUTS TO TWO BILGE PUMPS.
Condition: Unknown
Due 6 May 1987
Resolved 6 May 1987