Records from 1984 to 2000. Most recent: inspection, 29 September 2000.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 94
29 September 2000
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 14123
29 September 2000
MARPOL Annex I Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 823971
16 August 2000
Quarterly Examination
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1052732
17 May 2000
Control Verification · MARPOL Annex V Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1426420
6 July 1999
Quarterly Examination
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1092558
30 May 1999
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 805133
27 April 1999
Control Verification
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1365192
7 August 1998
Quarterly Examination
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1378430
21 May 1998
Deficiency Check
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1396930
5 May 1998
Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 790088
3 May 1998
Control Verification
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1430547
22 September 1997
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 408096
15 August 1997
Quarterly Examination
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1396781
26 June 1997
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1111722
4 June 1997
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1110010
24 April 1997
Quarterly Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1443875
15 January 1997
Quarterly Examination · MARPOL Annex I Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1390430
2 October 1996
Control Verification
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1363811
14 August 1996
Type not recorded
No type recorded · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 33155
14 August 1996
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1090373
12 July 1996
Quarterly Examination
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1363719
29 June 1996
Type not recorded
No type recorded · MSD KETCHIKAN · USCG Arctic District (CGD-A) · Activity 72418
6 April 1996
Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1078669
7 January 1996
Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1359015
4 October 1995
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 383849
4 October 1995
Control Verification
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1377541
10 August 1995
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1367471
7 August 1995
Quarterly Examination
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1392285
10 April 1995
Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1154189
9 April 1995
Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 843537
9 February 1995
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1147637
9 January 1995
Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1168746
27 October 1994
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 373991
27 October 1994
Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1359993
25 August 1994
Deficiency Check
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1174629
4 August 1994
MARPOL Annex I Examination · Quarterly Examination
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1356757
7 May 1994
Quarterly Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1377176
9 March 1994
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1165654
4 February 1994
Quarterly Examination
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1163999
7 November 1993
Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1354493
1 October 1993
Certificate of Compliance
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1155883
31 August 1993
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 180935
20 July 1993
Control Verification
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1395974
29 April 1993
Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1366828
18 February 1993
Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1359473
27 January 1993
Deficiency Check
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 828742
26 January 1993
Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 829570
30 October 1992
Certificate of Compliance
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1436715
28 September 1992
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 94776
24 September 1992
Certificate of Compliance · Control Verification
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 947619
3 August 1992
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 526149
3 August 1992
Control Verification
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1425284
25 May 1992
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 443281
21 May 1992
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 350867
5 May 1992
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 352182
5 May 1992
Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 946935
5 February 1992
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 954585
2 February 1992
Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1261134
25 December 1991
Type not recorded
No type recorded · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 84805
7 November 1991
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 647610
6 November 1991
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 346995
24 October 1991
Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1251324
7 August 1991
Control Verification
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1311080
6 May 1991
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1209419
11 February 1991
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 910494
26 October 1990
Certificate of Compliance
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 903125
25 July 1990
Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 924165
4 May 1990
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 337072
4 May 1990
Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 917169
3 February 1990
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1221966
7 November 1989
Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 899829
15 August 1989
Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1352376
5 August 1989
Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 889112
6 May 1989
Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 330255
6 May 1989
Control Verification
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1347681
29 January 1989
Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1207620
9 January 1989
Examination of Repairs
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1351807
21 October 1988
Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1196540
26 July 1988
Control Verification
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1035397
25 April 1988
Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1033221
16 January 1988
Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1323120
21 October 1987
Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1322675
6 August 1987
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1340755
6 May 1987
Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1336061
1 February 1987
Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1002301
29 October 1986
Control Verification
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1013048
23 July 1986
Control Verification
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 992369
29 April 1986
Control Verification
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 989560
8 February 1986
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 306938
8 February 1986
Control Verification
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 997713
20 November 1985
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 525483
9 November 1985
Control Verification
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1302553
1 May 1985
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 982550
28 November 1984
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 514033
Engineering
Issued 16 August 2000
Resolved
Hoses in Bunker Stations are past due on annual pressure testing.
Condition: Unknown
Due 30 August 2000
Resolved 24 August 2000
Lifesaving
Issued 27 April 1999
Resolved
Remove hydraulic oil tank from stairway 15, deck 4 prior to 27MAY99.
Condition: Unknown
Due 27 April 1999
Resolved 27 April 1999
Lifesaving
Issued 27 April 1999
Resolved
Remove reefer compressor from stairway 15 at deck 3 prior to 27MAY99.
Condition: Unknown
Due 27 April 1999
Resolved 27 April 1999
Lifesaving
Issued 27 April 1999
Resolved
Remove stores from stairway on deck 5 in way of FSD 179 prior to 29APR99.
Condition: Unknown
Due 29 April 1999
Resolved 30 April 1999
Lifesaving
Issued 27 April 1999
Resolved
Remove carpenter tools and stores from forward stairtower decks 4 and 5 prior to 29APR99.
Condition: Unknown
Due 29 April 1999
Resolved 30 April 1999
Accommodation/Occupational Safety
Issued 27 April 1999
Resolved
Provide written plan explaining proper stowage of housekeeping trolleys in an area other than passageways prior to 27MAY99.
Condition: Unknown
Due 27 April 1999
Resolved 27 April 1999
Fire Fighting
Issued 7 August 1998
Resolved
BOUNDARY BULKHEAD ABOVE FIRE SCREEN DOOR 317 HAS APPROXIMATELY 5" DIAMETER OPENING AS A RESULT OF EQUIPMENT REMOVAL.
Condition: Unknown
Due 9 August 1998
Resolved 26 August 1998
Fire Fighting
Issued 3 May 1998
Resolved
Boiler room main fire pump OOC.
Condition: Unknown
Due 4 May 1998
Resolved 4 May 1998
Fire Fighting
Issued 3 May 1998
Resolved
Fire detector system zone 11 OOC.
Condition: Unknown
Due 4 May 1998
Resolved 4 May 1998
Construction/Loadline
Issued 3 May 1998
Resolved
Engine room casing door port side, Sun Deck not indicated on FCP, updated FCP.
Condition: Unknown
Due 3 May 1998
Resolved 3 May 1998
Construction/Loadline
Issued 3 May 1998
Resolved
Install manhole cover in bulkhead #65, amidships, #4 A/C room, Sun Deck.
Condition: Unknown
Due 3 May 1998
Resolved 3 May 1998
Construction/Loadline
Issued 3 May 1998
Resolved
Bulkhead SFP insulation missing near FSD #11, #5 A/C room, Sun Deck.
Condition: Unknown
Due 3 May 1998
Resolved 3 May 1998
Accommodation/Occupational Safety
Issued 3 May 1998
Resolved
Remove and properly stow combustible material in locker with direct access to stair, FR 248, Sun Deck.
Condition: Unknown
Due 3 May 1998
Resolved 3 May 1998
Construction/Loadline
Issued 3 May 1998
Resolved
Install B-15 FSDs at access to Captains Lounge, Lido Deck.
Condition: Unknown
Due 3 May 1998
Resolved 3 May 1998
Construction/Loadline
Issued 3 May 1998
Resolved
Prove proper operation of FSDs and indicators for: 15, 20, 22a, 41, 29,30, 36, 25, 54, 55, 253.
Condition: Unknown
Due 3 May 1998
Resolved 3 May 1998
Fire Fighting
Issued 3 May 1998
Resolved
Locate and label the access for fire dampers #106 and #107 in way of cabin 100 on deck #7.
Condition: Unknown
Due 3 May 1998
Resolved 3 May 1998
Lifesaving
Issued 3 May 1998
Resolved
Seal (permanently) the "V.C." room port provisions embark station, comment #3 from CG MSC letter #P003375 dated 13NOV97.
Condition: Unknown
Due 3 May 1998
Resolved 3 May 1998
Accommodation/Occupational Safety
Issued 3 May 1998
Resolved
Remove stores in the forward crossover passageway (emergency exit) on deck #7.
Condition: Unknown
Due 3 May 1998
Resolved 3 May 1998
Accommodation/Occupational Safety
Issued 3 May 1998
Resolved
Remove combustibles (wood structures) in stairway outside of costume lockeron Deck #7.
Condition: Unknown
Due 3 May 1998
Resolved 3 May 1998
Fire Fighting
Issued 3 May 1998
Resolved
Remove miscellaneuos supplies, cleaning compounds from luggage room #19 & locate/label the access for fire damper access in luggage room #19.
Condition: Unknown
Due 3 May 1998
Resolved 3 May 1998
Fire Fighting
Issued 3 May 1998
Resolved
Remove cleaning compounds, solvents etc. and improper stowage above light fixture in carpenter shop on Deck #6.
Condition: Unknown
Due 3 May 1998
Resolved 3 May 1998
Fire Fighting
Issued 3 May 1998
Resolved
Install smoke detectors in following spaces: Stairway in way of FSD 179; fish preparation room, wine and soda manager office, lobby in way of FSD 257a, lobby between engine control room and boiler room.
Condition: Unknown
Due 3 May 1998
Resolved 3 May 1998
Fire Fighting
Issued 3 May 1998
Resolved
Update FCP with current location of pollution response equipment, deck #4, Provision embarkation area at FSD 204.
Condition: Unknown
Due 3 May 1998
Resolved 3 May 1998
Construction/Loadline
Issued 3 May 1998
Resolved
Repair watertight door from emergency generator room to weather deck and install proper sealing gasket.
Condition: Unknown
Due 3 May 1998
Resolved 3 May 1998
Fire Fighting
Issued 3 May 1998
Resolved
Prove proper operation/proper seal of the three vent closures to emergency generator room.
Condition: Unknown
Due 3 May 1998
Resolved 3 May 1998
Accommodation/Occupational Safety
Issued 3 May 1998
Resolved
Provide evidence that ward #3 in hospital is adequate for use as storeroom or remove stores from same.
Condition: Unknown
Due 3 May 1998
Resolved 3 May 1998
Unknown
Issued 3 May 1998
Resolved
Satisfy comments #1-3 of USCG Marine Safety Center RFSA plan review letter P003375, dated April 9, 1998.
Condition: Unknown
Due 3 May 1998
Resolved 3 May 1998
Lifesaving
Issued 3 May 1998
Resolved
Assign a properly trained and qualified person as second-in-charge L/R #8.
Condition: Unknown
Due 5 May 1998
Resolved 5 May 1998
Navigation
Issued 3 May 1998
Resolved
Clean oil from deck of steering gear flat.
Condition: Unknown
Due 3 May 1998
Resolved 3 May 1998
Fire Fighting
Issued 3 May 1998
Resolved
Install FSD indicator and prove proper closure of FSD in golden staircase, deck #4, FR. 193.
Condition: Unknown
Due 3 May 1998
Resolved 3 May 1998
Fire Fighting
Issued 15 August 1997
Resolved
Fire screen door 171 did not close properly.
Condition: Unknown
Due 15 August 1997
Resolved 21 August 1997
Fire Fighting
Issued 15 August 1997
Resolved
Fire screen door 211 indicates on bridge as 218
Condition: Unknown
Due 25 August 1997
Resolved 21 August 1997
Fire Fighting
Issued 15 August 1997
Resolved
Fire screen door fsd closed, but did not indicate closed on bridge.
Condition: Unknown
Due 25 August 1997
Resolved 21 August 1997
Construction/Loadline
Issued 15 August 1997
Resolved
No standard discharge connection for oily waste (MARPOL annex i, reg 19).
Condition: Unknown
Due 25 August 1997
Resolved 21 August 1997
Fire Fighting
Issued 4 June 1997
Resolved
Repair or replace fire screen doors #92, 94, & 133 prior to the return to US waters after drydocking in Portland, Or.
Condition: Unknown
Due 4 June 1997
Resolved 4 June 1997
Accommodation/Occupational Safety
Issued 4 June 1997
Resolved
Repair or replace escape handles on ice cream storeroom #6 and frozen vegatable room #2 prior to the return to US waters after drydocking in Portland, Or
Condition: Unknown
Due 4 June 1997
Resolved 4 June 1997
Electrical
Issued 15 January 1997
Resolved
Several horizontal wire runs are secured to the underside of wire trays with plastic ties. Several vertical wire runs are serures with plastic wire ties. The plastic wire ties were found thoughout the vessel from the main deck up. Issued requirement to replace plastic wire ties.
Condition: Unknown
Due 15 January 1997
Resolved 15 January 1997
Lifesaving
Issued 2 October 1996
Resolved
PROVE PROPER OPERATION OF LIFE BOAT #4 ENGINE.
Condition: Unknown
Due 3 October 1996
Resolved 8 October 1996
Documentation
Issued 2 October 1996
Resolved
COMPLETE LOCAL AREA SPECIFIC APPENDICE FOR SEWARD, AK. COMPLETE PRIOR TO RETURN TO SEWARD, AK.
Condition: Unknown
Due 2 October 1996
Resolved 2 October 1996
Lifesaving
Issued 2 October 1996
Resolved
REMOVE CARPET FROM DECK IN PAINT LOCKER.
Condition: Unknown
Due 3 October 1996
Resolved 8 October 1996
Documentation
Issued 4 October 1995
Resolved
Amend vessel's bunkering procedures to reflect all requirements of 33CFR155.750 prior to bunkering in U.S. waters.
Condition: Unknown
Due 4 October 1995
Resolved 4 October 1995
Lifesaving
Issued 9 January 1995
Resolved
UPDATE "MUSTER LIST" TO INCORPORATE WHICH OFFICERS ARE IN CHARGE OF MAINTANANCE OF LIFE SAVING APPLIANCES AS REQUIRED BY SOLAS 74 CH III.53.3.
Condition: Unknown
Due 9 January 1995
Resolved 9 January 1995
Fire Fighting
Issued 27 October 1994
Resolved
PROVIDE PORTABLE AIR-FOAM UNIT FOR THE EMERGENCY GENERATOR AS REQUIRED BY SOLAS 74 (AS AMENDED) CH II-2 REG 7.2.2
Condition: Unknown
Due 27 October 1994
Resolved 27 October 1994
Fire Fighting
Issued 27 October 1994
Resolved
PROVIDE 2 LIFELINES AT MAIN VERTICAL ZONE #5 FIRELOCKER AS REQUIRED BY SOLAS 74 (AS AMENDED) CH II-2 REG 17.2
Condition: Unknown
Due 27 October 1994
Resolved 27 October 1994
Fire Fighting
Issued 27 October 1994
Resolved
Provide 2 water fog applicators in the emergency generator room (machinery space of category A) as required by SOLAS 74 (as amended) CH II-2 reg. 7.6
Condition: Unknown
Due 27 October 1994
Resolved 27 October 1994
Accommodation/Occupational Safety
Issued 4 August 1994
Resolved
REMOVE EXCESS LAUNDRY CARTS FROM STAIR TOWERS, ALONG WITH EXTRA SUPPLIES STAGED IN STAIRTOWERS.
Condition: Unknown
Due 25 August 1994
Resolved 2 November 1994
Accommodation/Occupational Safety
Issued 4 August 1994
Resolved
REVIEW OPERATIONS OF HOTEL STAFF (CABIN STEWARDS) TO DETERMINE PLAN FOR STORING ROOM SERVICE CARTS OUT OF STAIR TOWERS.
Condition: Unknown
Due 25 August 1994
Resolved 2 November 1994
Electrical
Issued 4 August 1994
Resolved
BLOCK EMERGENCY BATTERIES IN BOX ON PORT BRIDGE WING.
Condition: Unknown
Due 25 August 1994
Resolved 2 November 1994
Lifesaving
Issued 4 August 1994
Resolved
STOW ALL GEAR (FIRST AID, TOOLS, ETC) INSIDE LIFEBOATS IN ACCORDANCE WITH SOLAS 74 UNAMMENDED III.12 AND/OR SOLAS 74 AMMENDED III.41.8.
Condition: Unknown
Due 25 August 1994
Resolved 2 November 1994
Electrical
Issued 4 August 1994
Resolved
BLOCK/SECURE BATTERIES (NEW AND USED) STOWED IN THE EMERGENCY GENERATOR SPACE.
Condition: Unknown
Due 25 August 1994
Resolved 2 November 1994
Fire Fighting
Issued 4 August 1994
Resolved
SERVICE/EXERCISE EXTERIOR VENTILATION DAMPNER "STENHOUSE SLIP" (PELICAN HOOK) RELEASES.
Condition: Unknown
Due 25 August 1994
Resolved 2 November 1994
Electrical
Issued 4 August 1994
Resolved
PROPERLY DEAD END ELECTRICAL CABLES IN RACE WAY ON FRAME #55, INSIDE ELECTRICAL LOCKERS.
Condition: Unknown
Due 25 August 1994
Resolved 2 November 1994
Accommodation/Occupational Safety
Issued 4 August 1994
Resolved
REMOVE TABLE/CHAIRS/LAUNDRY CARTS WHICH ARE BLOCKING EMERGENCY EXIT FROM LAUNDRY SPACE.
Condition: Unknown
Due 25 August 1994
Resolved 2 November 1994
Accommodation/Occupational Safety
Issued 4 August 1994
Resolved
REMOVE SPOOLS OF CABLES/TRASH CANS/ACCUMULATED TRASH FROM UNDER LADDER OF AFT-MOST CREWS STAIRS BETWEEN C AND D DECKS.
Condition: Unknown
Due 25 August 1994
Resolved 2 November 1994
Accommodation/Occupational Safety
Issued 4 August 1994
Resolved
KEEP EMERGENCY EXITS FROM DINING ROOMS FROM BEING BLOCKED BY LAUNDRY CARTS;KEEP CARTS FROM BLOCKING FIRE SCREEN DOORS.
Condition: Unknown
Due 25 August 1994
Resolved 2 November 1994
Documentation
Issued 7 May 1994
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 7 May 1994
Resolved 7 May 1994
Accommodation/Occupational Safety
Issued 7 May 1994
Resolved
REPLACE BULB FOR VALVE #287 ON WATERTIGHT VALVE INDICATING PANEL ON BRIDGE.
Condition: Unknown
Due 7 May 1994
Resolved 7 May 1994
Lifesaving
Issued 7 May 1994
Resolved
PROVIDE PROOF THAT #12 PORT LIFEBOAT LIMIT SWITCH HAS BEEN REPLACED.
Condition: Unknown
Due 7 May 1994
Resolved 7 May 1994
Accommodation/Occupational Safety
Issued 4 February 1994
Resolved
EITHER REMOVE COMBUSTIBLES FROM DECK LOCKER IN THE PORT SIDE OF THE PROMENADE DECK OR INSTALL SPRINKLERS.
Condition: Unknown
Due 4 February 1994
Resolved 4 February 1994
Accommodation/Occupational Safety
Issued 4 February 1994
Resolved
REMOVE COMBUSTIBLES STORE IN ELECTRICAL LOCKER AT THE TOP OF AFT STAIRWAY
Condition: Unknown
Due 4 February 1994
Resolved 4 February 1994
Fire Fighting
Issued 4 February 1994
Resolved
REPLACE DAMAGED FIRE HOSE AT HYDRANT STATION #195
Condition: Unknown
Due 4 February 1994
Resolved 4 February 1994
Accommodation/Occupational Safety
Issued 4 February 1994
Resolved
REPAIR WATER TIGHT BULKHEAD VALVES #287 & #40 AND FIX LIGHTS AT INDICATOR PANEL FOR WATER TIGHT BULKHEAD VALVES #39 & #49
Condition: Unknown
Due 4 February 1994
Resolved 4 February 1994
Fire Fighting
Issued 4 February 1994
Resolved
ADJUST FIRE SCREEN DOOR #25. CARPET PREVENTS CLOSING
Condition: Unknown
Due 4 February 1994
Resolved 4 February 1994
Lifesaving
Issued 4 February 1994
Resolved
REMOVE OIL DRUM FROM FAN ROOM #9
Condition: Unknown
Due 4 February 1994
Resolved 4 February 1994
Construction/Loadline
Issued 4 February 1994
Resolved
CONDUCT WEEKLY INSPECTIONS OF THE "DAMAGE CONTROL SYSTEMS" IAW SOLAS 74 (AMENDED) REG III-24.3.1. LOG THESE WEEKLY INSPECTIONS IAW REG III-25.3
Condition: Unknown
Due 4 February 1994
Resolved 4 February 1994
Lifesaving
Issued 4 February 1994
Resolved
PROVIDE DOCUMENTATION THAT "FLAME CARTS" MEET THE APPROVAL OF FLAG ADMINISTRATION
Condition: Unknown
Due 4 February 1994
Resolved 4 February 1994
Lifesaving
Issued 4 February 1994
Resolved
POST SIGNS WHICH INDICATE PROPER DIRECTION TO THE LIFEBOATS WHEN EVACUATINGTHROUGH PORT & STARBOARD SIDE EXITS AT THE FWD ACCOMODATION AREA ON DECK 10AND WHEN STANDING ON "[name withheld]" STAIRWAY.
Condition: Unknown
Due 4 February 1994
Resolved 4 February 1994
Lifesaving
Issued 4 February 1994
Resolved
CONDUCT TRAINING AND FAMILIARIZE CREW WITH WHAT EMERGENCY EQUIPMENT IS LOCATED IN LIFERAFTS & LIFEBOATS. TRAINING TO BE LOGGED IAW SOLAS 74(AS AMENDED) CH III REG 18.
Condition: Unknown
Due 4 February 1994
Resolved 4 February 1994
Accommodation/Occupational Safety
Issued 4 February 1994
Resolved
REMOVE COMBUSTIBLES FROM STORAGE LOCKER #36 AFT OF STAIRWAYS ON EMERALD DECK
Condition: Unknown
Due 4 February 1994
Resolved 4 February 1994
Fire Fighting
Issued 18 February 1993
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 18 February 1993
Resolved 18 February 1993
Construction/Loadline
Issued 27 January 1993
Resolved
PROVIDE PROPER A-0 BOUNDARIES AROUND THE HYDRAULIC STORAGE TANK LOCATED IN THE STAIRWAY, D DECK, FRAME 110
Condition: Unknown
Due 27 January 1993
Resolved 27 January 1993
Documentation
Issued 5 May 1992
Resolved
THE S.S. Azure Seas, a vessel with a fuel capacity of over 10,500 gallons, failed to have complete oil transfer procedures. The procedures for emtyingcontainment and tending mooring lines were not addressed, also the list of products transferred were missing.
Condition: Unknown
Due 5 May 1992
Resolved 21 September 1992
Construction/Loadline
Issued 5 May 1992
Resolved
REPAIR WATER TIGHT DOOR INDICATORS ON #1,7,27, AND 47._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 5 May 1992
Resolved 5 May 1992
Fire Fighting
Issued 5 May 1992
Resolved
PROVIDE FLAG ADMINISTRATION APPROVAL FOR THE MACHINERY SPACE DIRECTLY ACCESSING THE STAIRWAY AT FRAME 115, AT THE BOTTOM OF THE STAIRS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 5 May 1992
Resolved 5 May 1992
Construction/Loadline
Issued 5 May 1992
Resolved
PROVIDE PROPER A-0 BOUNDRIES AROUND THE HYDRAULIC STORAGE TANK LOCATED IN THE STAIRWAY, D DECK, FRAME 110_x001C_ _x001C_ _x001C_
Condition: Unknown
Due 5 May 1992
Resolved 5 May 1992
Accommodation/Occupational Safety
Issued 5 May 1992
Resolved
REMOVE COMBUSTIBLES STORED IN THE SHAMPOO AND THE HOOVER LOCKERS IN THE STAIRWAY ON D DECK, FRAME 110. THESE WERE ORIGINALLY TOILETS AND HAVE BEEN CONVERTED TO STORE ROOMS CONTRARY TO SOLAS._x001C_ _x001C_
Condition: Unknown
Due 5 May 1992
Resolved 5 May 1992
Engineering
Issued 6 November 1991
Resolved
Vessels' oil transfer procedures were incomplete in that did not provide _x001C_ for the amount of people required to be on scene during the transfer of _x001C_ fuel oil._x001C_ _x001C_
Condition: Unknown
Due 7 February 1992
Resolved 7 February 1992
Construction/Loadline
Issued 6 November 1991
Resolved
Vessel did not have a permanent loadline marking as required by _x001C_ 46 CFR 42.03-10(c).
Condition: Unknown
Due 7 February 1992
Resolved 7 February 1992
Engineering
Issued 6 November 1991
Resolved
Vessels' oil transfer procedures did not contain procedures for reporting_x001C_ the discharge of oil to the Coast Guard._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 February 1992
Resolved 7 February 1992
Engineering
Issued 6 November 1991
Resolved
Vessels' oil transfer procedures were not complete because it did not_x001C_ contain procedures for emptying fuel oil manifold containment._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 February 1992
Resolved 7 February 1992
Fire Fighting
Issued 6 May 1991
Resolved
REPAIR FIRE SCREEN DOOR RELEASES ON DOORS NO. 97,124,159,166,177,194,293,_x001C_ AND 313.
Condition: Unknown
Due 6 May 1991
Resolved 6 May 1991
Lifesaving
Issued 6 May 1991
Resolved
REPAIR STARBOARD LIFEBOAT ENGINE ON LIFEBOAT NO. 14.
Condition: Unknown
Due 6 May 1991
Resolved 6 May 1991
Engineering
Issued 25 July 1990
Resolved
PRIOR TO NEXT CONTROL VERIFICATION REPAIR AUTOMATIC SHUT-DOWN VALVE FOR OILY WATER SERVICE PUMP.
Condition: Unknown
Due 25 July 1990
Resolved 25 July 1990
Engineering
Issued 25 July 1990
Resolved
PRIOR TO NEXT CONTROL VERIFICATION PROVIDE APPROPRIATE OIL TRANSFER PROCEDURES IN ACCORDANCE WITH 33 CFR 155.750
Condition: Unknown
Due 25 July 1990
Resolved 25 July 1990
Lifesaving
Issued 25 July 1990
Resolved
PRIOR TO NEXT CONTROL VERIFICATION PROVIDE RETROREFLECTIVE TAPE ON APPROXIMATELY (50) LIFE VESTS AS SEEN DURING BOAT DRILL.
Condition: Unknown
Due 25 July 1990
Resolved 25 July 1990
Fire Fighting
Issued 25 July 1990
Resolved
PRIOR TO NEXT CONTROL VERIFICATION PROVIDE APPROPRIATE LATCHES ON ALL EXTERIOR FIRE STATIONS. TAPE AND STRING AROUND BOXES SHALL BE REMOVED.
Condition: Unknown
Due 25 July 1990
Resolved 25 July 1990
Documentation
Issued 8 February 1986
Resolved
MAKE VESSEL READY FOR CONTROL VERIFICATION EXAMINATION.
Condition: Unknown
Due 8 February 1986
Resolved 8 February 1986
Fire Fighting
Issued 9 November 1985
Resolved
REPAIR FIRE PUMP AND SPRINKLER PUMP PRESSURE GAUGES LOCATED AT PUMP.
Condition: Unknown
Due 9 November 1985
Resolved 9 November 1985
Lifesaving
Issued 9 November 1985
Resolved
INSURE ALL EMERGENCY EXITS ARE FREE AND CLEAR OF OBSTRUCTIONS AND ARE UNLOCKED.
Condition: Unknown
Due 9 November 1985
Resolved 9 November 1985
Fire Fighting
Issued 9 November 1985
Resolved
SPOT CHECK OF DRAFT STOPS REVEALED TWO MISSING AND ONE POORLY FITTING. DURRING NEXT EXAM BE PREPARED TO EXAMINE ANY DRAFT STOPS CHOSEN BY INSPECTOR.
Condition: Unknown
Due 9 November 1985
Resolved 9 November 1985
Fire Fighting
Issued 9 November 1985
Resolved
FSD #44 TO EMERGENCY GENERATOR ROOM BULKHEAD REQUIRES HOLES TO BE CLOSED.
Condition: Unknown
Due 9 November 1985
Resolved 9 November 1985
Fire Fighting
Issued 9 November 1985
Resolved
SPRINKLER PUMP AUTO START WAS BLOCKED OUT AND WOULD NOT START. PROVISIONS TO BE MADE TO ENSURE UNIT IS CORRECTLY LINED UP FOR AUTO START.
Condition: Unknown
Due 9 November 1985
Resolved 9 November 1985
Documentation
Issued 9 November 1985
Resolved
VESSEL DUE FOR QUARTERLY EXAM
Condition: Unknown
Due 9 November 1985
Resolved 9 November 1985
Fire Fighting
Issued 9 November 1985
Resolved
REMOVE LOCK BACKS FROM ALL FSD'S #220,245,239 & 37 WERE FITTED WITH LOCK BACKS
Condition: Unknown
Due 9 November 1985
Resolved 9 November 1985
Fire Fighting
Issued 9 November 1985
Resolved
REMOVE TAPE IN DOOR FRAM FOR FSD #91
Condition: Unknown
Due 9 November 1985
Resolved 9 November 1985
Documentation
Issued 1 May 1985
Resolved
MAKE VESSEL READY FOR 1ST QUARTERLY CONTROL VERIFICATION RE-INSPECTION.
Condition: Unknown
Due 1 May 1985
Resolved 1 May 1985