MAURY USCG vessel records Sign in
← All vessels

PARAMACAY

PARAMACAY is a 1983 tank ship. The Coast Guard has recorded 46 inspections since 1984, most recently in January 2002, along with 37 deficiencies and 3 operational controls.

Records from 1984 to 2002. Most recent: inspection, 14 January 2002.

Built
1983
Last inspected
14 January 2002
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8123638 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
229494
Flag
VENEZUELA
—
Maury page id
psix-229494

Inspections, by type

…with no type recorded31
Years with a record 14 calendar years (1984–2002)
The 46 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 24 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it11800 - Dead Weight, Ton
3593 - Regulatory (Subpart C or D), Net Ton
11977 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 46

14 January 2002 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1478583
11 January 2002 Security Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1492494
10 January 2002 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1478725
14 August 2001 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 292755
14 August 2001 Letter of Compliance (Initial/Renewal)
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1069020
28 June 2001 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 291473
7 March 2001 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 287812
7 March 2001 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1373377
13 February 2000 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 535322
3 December 1999 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 809861
13 November 1999 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 806335
15 August 1999 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 432032
14 August 1999 Letter of Compliance (Initial/Renewal)
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1118705
3 May 1998 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 73862
1 May 1998 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1409894
13 November 1997 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 409848
4 July 1997 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 405272
3 July 1997 Letter of Compliance (Initial/Renewal)
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1371937
21 September 1995 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 382890
21 September 1995 Letter of Compliance (Initial/Renewal)
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 879762
16 September 1994 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 370496
16 September 1994 MARPOL Annex I Examination
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1434155
19 July 1994 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 513776
22 March 1994 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1167931
7 March 1994 Administrative
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 857638
10 August 1993 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 360127
10 August 1993 Certificate of Compliance
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1455090
10 March 1989 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 516469
10 March 1989 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1201177
10 October 1988 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 491949
28 May 1988 Certificate of Compliance
Administrative · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 886792
10 February 1988 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1326678
30 October 1987 Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1021756
30 October 1987 MARPOL Annex II Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1021759
23 April 1987 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 450848
13 February 1987 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 461594
10 February 1987 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 449784
9 February 1987 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1014731
25 January 1987 Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 313915
21 January 1987 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 448095
31 October 1986 Type not recorded
No type recorded · COTP NEW YORK · USCG Northeast District (CGD-NE) · Activity 478861
22 May 1986 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 452460
22 May 1986 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 986125
14 March 1986 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 307512
14 March 1986 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1302661
7 September 1984 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 487359

Deficiency record · 37

Fire Fighting
Issued 28 June 2001 Resolved
REISSUED FROM MI01007463. Replace rubber fire dampers for the intake and discharge of the emergency generator space with non-combustible material. Provide a class report to the Cognizant Officer in Charge Marine Inspection.
Condition: Unknown
Due 25 August 2001
Resolved 25 August 2001
Unknown
Issued 28 June 2001 Resolved
REPAIR STEAM/WATER LEAK ON THE BURNER END OF THE INERT GAS GENERATOR._x001C_ CLEAR REQUIREMENT PRIOR TO 14AUG01. SOLAS II-2/62 _x001C_ PROVIDE CLASS REPORT TO THE COGNIZANT OFFICER IN CHARGE MARINE INSPECTION.
Condition: Unknown
Due 25 August 2001
Resolved 25 August 2001
Unknown
Issued 28 June 2001 Resolved
PROVE PROPER OPERATION OF ALL LIGHTS ON THE INERT GAS GENERATOR CONTRL PANEL. REPAIR REQUIREMENT PRIOR TO 14AUG01. SALAS II-2/62 _x001C_ PROVIDE CLASS REPORT TO THE COGNIZANT OFFICER IN CHARGE MARINE INSPECTION.
Condition: Unknown
Due 25 August 2001
Resolved 25 August 2001
Unknown
Issued 28 June 2001 Resolved
PROVE PROPER OPERATION OF ALL ALARMS AND SHUTDOWN ON THE INERT GAS GENORATOR. RESOLVE REQUIREMENT PRIOR TO 14AUG01. SOLAS II-2/62 _x001C_ PROVIDE CLASS REPORT TO OFFICER IN CHARGE MARINE INSPECTION.
Condition: Unknown
Due 25 August 2001
Resolved 25 August 2001
Unknown
Issued 28 June 2001 Resolved
PROVE PROPER OPERATION OF THE AUDIBLE ALARM FOR THE GAS DETECTION SYSTEM. CLEAR REQUIREMENT PRIOR TO 14AUG01. IGC 13.6.4 _x001C_ PROVIDE CLASS REPORT TO OFFICER IN CHARGE MARINE INSPECTOR.
Condition: Unknown
Due 11 July 2001
Resolved 11 July 2001
Fire Fighting
Issued 7 March 2001 Resolved
REPLACE RUBBER FIRE DAMPERS FOR THE INTAKE AND DISCHARGE OF THE EMERGENCY GENERATOR SPACE WITH NON-COMBUSTIBLE MATERIAL._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 7 March 2001
Resolved 7 March 2001
Electrical
Issued 7 March 2001 Resolved
REPAIR ELECTRICAL PACKING GLAND FOR THE #3 PORT SIDE VAPOR LINE VALVE
Condition: Unknown
Due 7 March 2001
Resolved 7 March 2001
Deck/Cargo
Issued 7 March 2001 Resolved
PROVE PROPER OPS OF #1 PORT SIDE QUICK ACTING VALVE ON THE CARGO MANIFOLD. VALVE TO CLOSE WITHIN 30 SECONDS OF EMERGENCY SHUTDOWN ACTUATION. IN ADDITION, VALVE SHOULD OPERATE SMOOTHLY DURING CLOSURE.
Condition: Unknown
Due 7 March 2001
Resolved 7 March 2001
Lifesaving
Issued 7 March 2001 Resolved
CATWALK OVER CARGO TANKS WAS MADE OF WOOD. VSL TO REPLACE WITH NON- COMBUSTIBLE MATERIAL.
Condition: Unknown
Due 7 March 2001
Resolved 7 March 2001
Deck/Cargo
Issued 7 March 2001 Resolved
PROVE PROPER OPERATION OF THE INERT GAS SYSTEM.
Condition: Unknown
Due 7 March 2001
Resolved 7 March 2001
Deck/Cargo
Issued 7 March 2001 Resolved
FIX FUEL LEAKS ON IGS
Condition: Unknown
Due 7 March 2001
Resolved 7 March 2001
Construction/Loadline
Issued 7 March 2001 Resolved
RENEW BOTTOM OF DOOR COAMING FOR EMERGENCY GENERATOR SPACE.
Condition: Unknown
Due 7 March 2001
Resolved 7 March 2001
Lifesaving
Issued 7 March 2001 Resolved
CONDUCT AN INTERNATIONAL SAFETY MANAGEMENT SYSTEM AUDIT AND ADDRESS WHY IMOCERTIFICATE OF FITNESS AND SAFETY CONSTRUCTION CERTIFICATE DID NOT HAVE LAST ANNUAL SURVEYS COMPLETED/ENDORSED.
Condition: Unknown
Due 7 March 2001
Resolved 7 March 2001
Deck/Cargo
Issued 7 March 2001 Resolved
TEMPERTURE SENSOR ON THE #3 CARGO LINE BROKEN. VESSEL TO RENEW SENSOR.
Condition: Unknown
Due 12 March 2001
Resolved 12 March 2001
Deck/Cargo
Issued 7 March 2001 Resolved
RENEW BROKEN FLAME SENSOR UNIT ON IGS.
Condition: Unknown
Due 7 March 2001
Resolved 7 March 2001
Construction/Loadline
Issued 7 March 2001 Resolved
VESSEL'S SUPPORT BRACKETS FOR DECK SPRAY PIPING IN WAY OF #1 PORT & #3 PORT/STARBOARD CARGO TANK DOMES WERE WASTED. SUPPORT BRACKETS TO BE RENEWED
Condition: Unknown
Due 7 March 2001
Resolved 7 March 2001
Documentation
Issued 7 March 2001 Resolved
VESSEL'S IMO CERTIFICATE OF FITNESS ON BOARD LACKED LATEST ANNUAL ENDORSEMENT.
Condition: Unknown
Due 7 March 2001
Resolved 12 March 2001
Documentation
Issued 7 March 2001 Resolved
VESSEL'S SOLAS SAFETY CONSTRUCTION CERTIFICATE LACKED THE LATEST ANNUAL ENDORSEMENT.
Condition: Unknown
Due 8 March 2001
Resolved 12 March 2001
Electrical
Issued 7 March 2001 Resolved
ELECTRICAL CABLE RAKES AND TIE DOWNS IN WAY OF #2 CARGO PUMP, FRONT SIDE #3STARBOARD CARGO TANK DOME, AFT SIDE OF #3 PORT CARGO TANK DOME, AND #1 PORTCARGO TANK WERE WASTED. VESSEL TO RENEW CABLE RAKES AND TIE DOWNS
Condition: Unknown
Due 7 March 2001
Resolved 7 March 2001
Deck/Cargo
Issued 15 August 1999 Resolved
VESSEL IS NOT TO DISCHARGE CARGO AT IN US WATER FROM #4 PORT CARGO TANK, UNTIL THE #4 PORT LIQUID QUICK CLOSING VALVE IS RENEWED/REPLACED TO THE SATISFACTION OF A CLASS SURVEYOR. PROVIDE USCG WITH CLASS REPORT.
Condition: Unknown
Due 15 September 1999
Resolved 9 September 1999
Lifesaving
Issued 4 July 1997 Resolved
PROVIDE SPAN CALIBRATION GAS FOR PORTABLE EXPLOSIVE/ GAS DETECTORS._x001C_ CORRECT PRIOR TO NEXT U.S. PORT.
Condition: Unknown
Due 8 August 1997
Resolved 12 September 1997
Lifesaving
Issued 4 July 1997 Resolved
REPLACE STBD SIDE FLYING BRIDGE SELF IGNITING LIGHT.
Condition: Unknown
Due 4 July 1997
Resolved 9 July 1997
Lifesaving
Issued 4 July 1997 Resolved
REPLACE 19 BAD PROVISIONS TO STBD BOAT AND 20 BAD PROVISIONS TO PORT BOAT.
Condition: Unknown
Due 4 July 1997
Resolved 9 July 1997
Lifesaving
Issued 21 September 1995 Resolved
4 LINE THROWING GUNS ARE EXPIRED 6/94._x001C_ SOLAS 74 CHAPTER III PART C REGULATION 49.
Condition: Unknown
Due 2 October 1995
Resolved 2 October 1995
Documentation
Issued 21 September 1995 Resolved
ORIGINAL COPY OF THE CERTIFICATE OF FINANCIAL RESPONSIBILITY (COFR) NOT ONBOARD.
Condition: Unknown
Due 9 July 1997
Resolved 9 July 1997
Documentation
Issued 21 September 1995 Resolved
VESSEL RESPONSE PLAN DOES NOT HAVE PUERTO RICO GEOGRAPHIC INFORMATION.
Condition: Unknown
Due 9 July 1997
Resolved 9 July 1997
Documentation
Issued 21 September 1995 Resolved
VESSEL RESPONSE PLAN DOES NOT HAVE PUERTO RICO GEOGRAPHIC INFORMATION.
Condition: Unknown
Due 9 July 1997
Resolved 9 July 1997
Documentation
Issued 21 September 1995 Resolved
SHIPBOARD OIL POLLUTION EMERGENCY PLAN (SOPEP) IS MISSING SECTION 4, THE NATIONAL COOPERATION SECTION._x001C_ MARPOL, REGULATION 26.
Condition: Unknown
Due 9 July 1997
Resolved 9 July 1997
Documentation
Issued 22 March 1994 Resolved
VESSEL FAILED TO APPLY TO G-MSC FOR RENEWAL OF EXPIRED SUBCHAPTER "O" ENDORSEMENT (SOE). PROPERLY APPLY FOR SOE PRIOR TO CARRYING CARGO IN ANY U.S. WATERS.
Condition: Unknown
Due 22 March 1994
Resolved 22 March 1994
Navigation
Issued 10 August 1993 Resolved
U.S. COAST PILOT NOT CORRECTED UP TO DATE.
Condition: Unknown
Due 22 July 1994
Resolved 22 July 1994
Navigation
Issued 10 August 1993 Resolved
CG LIGHTLIST NOT CORRECTED UP TO DATE.
Condition: Unknown
Due 7 March 1994
Resolved 7 March 1994
Navigation
Issued 10 August 1993 Resolved
CHART 25677 NOT CORRECTED UP TO DATE.
Condition: Unknown
Due 7 March 1994
Resolved 7 March 1994
Deck/Cargo
Issued 10 August 1993 Resolved
PROVIDE TWO SETS OF PORTABLE GAS DETECTION EQUIPMENT IN ACCORDANCE WITH IGC, PART 13.6.13.
Condition: Unknown
Due 10 August 1993
Resolved 10 August 1993
Deck/Cargo
Issued 10 August 1993 Resolved
MAKE PORTABLE COMBUSTIBLE GAS METER OPERABLE.
Condition: Unknown
Due 10 August 1993
Resolved 10 August 1993
Documentation
Issued 10 March 1989 Resolved
OBTAIN NEW SOE CERTIFICATE FOR CURRENT LOC.
Condition: Unknown
Due 10 March 1989
Resolved 10 March 1989
Deck/Cargo
Issued 30 October 1987 Resolved
REPLACE/REPAIR DEFECTIVE DIAPHRAGM IN PORTABLE DRAEGER TOXIC VAPOR DETECTOR
Condition: Unknown
Due 30 October 1987
Resolved 30 October 1987
Navigation
Issued 14 March 1986 Resolved
33 CFR 164.38 FOREIGN TANK VESSEL OVER 10,000 GT. WAS OPERATING IN US WATERS WITHOUT AN OPERATIONAL AUTOMATIC RADAR PLOTTING AID (ARPA).
Condition: Unknown
Due 14 March 1986
Resolved 14 March 1986

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.