MAURY USCG vessel records Sign in
← All vessels

TROPICAL DAWN

TROPICAL DAWN is a 1983 freight ship. The Coast Guard has recorded 51 inspections since 1984, most recently in June 2001, along with 58 deficiencies and 2 operational controls.

Records from 1984 to 2001. Most recent: inspection, 11 June 2001.

Built
1983
Last inspected
11 June 2001
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

8300559 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
229500
Flag
VANUATU
—
Maury page id
psix-229500

Inspections, by type

…with no type recorded50
Years with a record 17 calendar years (1984–2001)
The 51 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 25 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it9961 - Dead Weight, Ton
3599 - Regulatory (Subpart C or D), Net Ton
8234 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 3

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

CAPT. J Commercial Fishing Vessel · MISLE 100330 · 9 November 1993 · activity 138433CAPTAIN VUONG Commercial Fishing Vessel · MISLE 115802 · 9 November 1993 · activity 138433GRACE ELAINE Commercial Fishing Vessel · MISLE 295927 · 9 November 1993 · activity 138433

Inspection history · 51

11 June 2001 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 158335
10 April 2001 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 289177
12 February 2001 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 287741
20 October 1999 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 433964
7 July 1999 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 708347
6 July 1999 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 212286
5 October 1998 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 421135
24 November 1997 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 410335
20 October 1997 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 409118
3 March 1997 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 401167
23 October 1996 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 396710
29 April 1996 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 390705
8 April 1996 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 389781
6 November 1995 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 384549
28 August 1995 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 382154
28 August 1995 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 668082
21 August 1995 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 381936
14 August 1995 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 381670
31 July 1995 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 381162
13 February 1995 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 375296
16 August 1994 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 369548
15 August 1994 Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 866888
11 July 1994 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 368516
11 July 1994 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1443482
2 March 1994 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 460314
9 November 1993 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 138433
30 August 1993 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 668081
4 August 1993 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 360586
3 August 1993 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 146191
11 May 1993 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 514361
2 November 1992 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 459934
27 May 1992 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 527427
11 January 1992 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 540325
12 December 1991 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1260751
25 November 1991 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 347360
22 July 1991 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 345043
25 March 1991 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 476044
6 August 1990 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 338644
9 April 1990 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 336365
12 February 1990 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 522108
7 August 1989 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 331894
13 July 1989 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 331445
20 June 1988 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 324039
13 July 1987 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 317304
11 May 1987 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 316852
24 November 1986 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 501620
5 May 1986 Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 308553
21 April 1986 Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 308202
18 August 1985 Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 510900
4 March 1985 Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 300679
29 May 1984 Type not recorded
No type recorded · COTP PHILADELPHIA · USCG East District (CGD-E) · Activity 489125

Deficiency record · 58

Lifesaving
Issued 12 February 2001 Resolved
Noted guard to # 2 Steering gear motor to be wasted. Replace with new machinery guard no later than 12MAR01._x001C_ SOLAS Amended 74/II-2/45
Condition: Unknown
Due 12 March 2001
Resolved 9 April 2001
Fire Fighting
Issued 12 February 2001 Resolved
Observed that "A" class boundary doors to engine room in poor condition. Noted several temporary repairs in particular the foot of doors no longer meets definition of class "A" boundary._x001C_ SOLAS 74/II-47
Condition: Unknown
Due 12 March 2001
Resolved 9 April 2001
Lifesaving
Issued 12 February 2001 Resolved
Observed four flourecent lights located in the vincinty of shaft/aft engineroom to be missing covers._x001C_ SOLAS 74/AMEND/II-1/45
Condition: Unknown
Due 12 March 2001
Resolved 9 April 2001
Fire Fighting
Issued 20 October 1997 Resolved
GENERAL SERVICE/FIRE PUMP HAS SOFT-PATCH WITH PEN HOLE LEAK ON DISCHARGE SIDE OF PUMP ELBOW, AS REQUIRED BY SOLAS 74 (AMENDED) CHAPTER, I, REG. 10 (c).
Condition: Unknown
Due 24 November 1997
Resolved 24 November 1997
Deck/Cargo
Issued 8 April 1996 Resolved
REMOVE EXCESS OIL AND OIL RESIDUE FROM THE BOILER WATER FEED PUMP ROOM.
Condition: Unknown
Due 13 April 1996
Resolved 15 April 1996
Accommodation/Occupational Safety
Issued 8 April 1996 Resolved
RENEW AS ORIGINAL DETERIORATED SEA WATER PIPING STARBOARD SIDE OF DISTILLING PLANT.
Condition: Unknown
Due 13 April 1996
Resolved 15 April 1996
Engineering
Issued 8 April 1996 Resolved
RENEW AS ORIGINAL DETERIORATED FRESH WATER COOLING SUPPLY PIPE TO CONTAINERS LOCATED FORWARD ENGINE ROOM CENTERLINE.
Condition: Unknown
Due 13 April 1996
Resolved 15 April 1996
Engineering
Issued 8 April 1996 Resolved
RENEW AS ORIGINAL DETERIORATED PIPING FROM/TO THE SANITARY/COOLING WATER PUMP LOCATED IN THE ENGINE ROOM LOWER LEVEL FORWARD PORT CORNER(2 BAD SECTIONS)
Condition: Unknown
Due 13 April 1996
Resolved 15 April 1996
Navigation
Issued 8 April 1996 Resolved
PROVIDE ON BOARD VESSEL UP TO DATE CHARTS FOR VESSELS INTENDED VOYAGE._x001C_ SOLAS 74 (AMENDED) V/20
Condition: Unknown
Due 13 April 1996
Resolved 15 April 1996
Fire Fighting
Issued 8 April 1996 Resolved
RENEW AS ORIGINAL DETERIORATED SEA WATER PIPING TO/FROM MAIN FIRE PUMP LOCATED LOWER LEVEL FWD PORT CORNER._x001C_ SOLAS 74 (AMENDED)II-2/21
Condition: Unknown
Due 13 April 1996
Resolved 15 April 1996
Deck/Cargo
Issued 8 April 1996 Resolved
REMOVE ALL EXCESS OIL AND OIL RESIDUE FROM THE AREAS SURROUNDING THE GENERATORS, ALL CONTAINMENTS AND THE ENGINE ROOM BILGE AREA. SLOP TANKS MUST HAVE 50% CAPACITY REMAINING PRIOR TO SAILING.
Condition: Unknown
Due 13 April 1996
Resolved 15 April 1996
Electrical
Issued 8 April 1996 Resolved
RENEW/REPAIR BROKEN LIGHT FIXTURE BEHIND MAIN SWITHBOARD.
Condition: Unknown
Due 13 April 1996
Resolved 15 April 1996
Deck/Cargo
Issued 8 April 1996 Resolved
REMOVE EXCESS OIL AND OIL RESIDUE FROM SEPARATOR ROOM.
Condition: Unknown
Due 13 April 1996
Resolved 15 April 1996
Fire Fighting
Issued 8 April 1996 Resolved
RENEW AS ORIGINAL DETERIORATED FIREMAIN PIPING TO PORT ANCHOR WASH._x001C_ SOLAS 74 (AMENDED) II-2/21.
Condition: Unknown
Due 13 April 1996
Resolved 15 April 1996
Fire Fighting
Issued 8 April 1996 Resolved
RENEW AS ORIGINAL DETERIORATED FIREMAIN PIPING TO STBD ANCHOR WASH._x001C_ SOLAS 74 (AMENDED) II-2/21
Condition: Unknown
Due 13 April 1996
Resolved 15 April 1996
Accommodation/Occupational Safety
Issued 8 April 1996 Resolved
RENEW AS ORIGINAL DETERIORATED NATURAL VENTILATION CLOSURE LOCATED ON THE MAIN DECK FORWARD PORT SIDE._x001C_ SOLAS 74 II-2/25(c)
Condition: Unknown
Due 13 April 1996
Resolved 15 April 1996
Fire Fighting
Issued 8 April 1996 Resolved
RENEW ALL DEFECTIVE FIRE HOSES THROUGHOUT VESSEL._x001C_ SOLAS 74 (AMENDED) II-2/21
Condition: Unknown
Due 13 April 1996
Resolved 15 April 1996
Fire Fighting
Issued 8 April 1996 Resolved
PROVIDE DUAL PURPOSE NOZZLES FOR EACH FIRE HOSE LOCATED IN THE ENGINE ROOM.SOLAS 74 II-2/5(g)(iv)
Condition: Unknown
Due 13 April 1996
Resolved 15 April 1996
Fire Fighting
Issued 8 April 1996 Resolved
RENEW/REPAIR DETERIORATED HOSE TO PORTABLE CO2 FIRE EXTINGUISHER LOCATED INTHE SEPARATOR ROOM._x001C_ SOLAS 74 (AMENDED) II-2/21
Condition: Unknown
Due 13 April 1996
Resolved 15 April 1996
Electrical
Issued 8 April 1996 Resolved
RENEW/REPAIR INOPERABLE LIGHTING TO FAN ROOM LOCATED IN THE UPPER LEVEL ENGINE ROOM PORT SIDE._x001C_
Condition: Unknown
Due 13 April 1996
Resolved 15 April 1996
Lifesaving
Issued 8 April 1996 Resolved
RENEW ALL DEFECTIVE RING LIFEBUOYS. PROVIDE EIGHT RING LIFEBUOYS ON STATION IN SERVICEABLE CONDITION AND AVAILABLE FOR IMMEDIATE USE._x001C_ SOLAS 74 (AMENDED) III/19.2
Condition: Unknown
Due 13 April 1996
Resolved 15 April 1996
Accommodation/Occupational Safety
Issued 8 April 1996 Resolved
RENEW AS ORIGINAL DETERIORATED FRESH WATER PIPING LOCATED IN THE OVERHEAD OF THE PURIFIER ROOM.
Condition: Unknown
Due 13 April 1996
Resolved 15 April 1996
Engineering
Issued 8 April 1996 Resolved
RENEW AS ORIGINAL DETERIORATED SALT WATER PIPING LOCATED IN THE OVERHEAD OFTHE PURIFIER ROOM IN WAY OF THE PURIFIER CONTROL PANEL.
Condition: Unknown
Due 13 April 1996
Resolved 15 April 1996
Engineering
Issued 8 April 1996 Resolved
RENEW/REPAIR STEAM LEAK LOCATED AFT IN THE PURIFIER ROOM.
Condition: Unknown
Due 13 April 1996
Resolved 15 April 1996
Engineering
Issued 8 April 1996 Resolved
RENEW AS ORIGINAL DETERIORATED SALT WATER PIPING TO #2 MAIN GENERATOR.
Condition: Unknown
Due 13 April 1996
Resolved 15 April 1996
Engineering
Issued 8 April 1996 Resolved
RENEW AS ORIGINAL DETERIORATED SALT WATER PIPING (10 INCH PIPE) LOCATED OUTBOARD #1 MAIN GENERATOR BENEATH DECK PLATES.
Condition: Unknown
Due 13 April 1996
Resolved 15 April 1996
Electrical
Issued 8 April 1996 Resolved
RENEW BROKEN/INOPERABLE LIGHT FIXTURES THROUGHOUT THE ENGINE ROOM. _x001C_ SOLAS 74 II-1/27(a)
Condition: Unknown
Due 29 April 1996
Resolved 29 April 1996
Accommodation/Occupational Safety
Issued 8 April 1996 Resolved
RENEW/REPAIR INOPERABLE MAIN VENTILATOR LOCATED ON THE FOCSLE STBD SIDE._x001C_ SOLAS 74 II-2/25(c)
Condition: Unknown
Due 13 April 1996
Resolved 15 April 1996
Fire Fighting
Issued 8 April 1996 Resolved
SERVICE FIRE MAIN RELIEF VALVE/ENSURE VALVES ARE ADJUSTED AS TO PREVENT EXCESSIVE PRESSURE IN ANY PART OF THE FIRE MAIN SYSTEM._x001C_ SOLAS 74 II-2/5(b)(iii)
Condition: Unknown
Due 13 April 1996
Resolved 15 April 1996
Accommodation/Occupational Safety
Issued 8 April 1996 Resolved
PROVIDE GASKET AND FREE FROZEN DOGGING BOLTS TO GOOSENECK VENT LOCATED PORTSIDE ON FANTAIL._x001C_ SOLAS 74 II-2/25(c)
Condition: Unknown
Due 13 April 1996
Resolved 15 April 1996
Accommodation/Occupational Safety
Issued 8 April 1996 Resolved
RENEW/REPAIR INOPERABLE MAIN VENTILATION CLOSURE LOCATED FWD OF DECK HOUSE STBD SIDE._x001C_ SOLAS 74 II-2/25(c)
Condition: Unknown
Due 13 April 1996
Resolved 15 April 1996
Lifesaving
Issued 8 April 1996 Resolved
PROVIDE WEAK LINKS FOR THE SEA PAINTERS ON THE TWO 15 PERSON LIFERAFTS THATWILL ALLOW THE LIFERAFTS TO FLOAT FREE OF ITS STOWAGE, INFLATE AND BREAK FREE FROM THE VESSEL IN THE EVENT OF SINKING._x001C_ SOLAS 74 III/15(p)(i)
Condition: Unknown
Due 13 April 1996
Resolved 15 April 1996
Accommodation/Occupational Safety
Issued 8 April 1996 Resolved
RENEW MISSING VENTILATION CLOSURE TO NATURAL VENT LOCATED PORT SIDE MAIN DECK IN WAY OF GANGWAY._x001C_ SOLAS 74 II-2/25(c)
Condition: Unknown
Due 13 April 1996
Resolved 15 April 1996
Accommodation/Occupational Safety
Issued 8 April 1996 Resolved
RENEW AS ORIGINAL DETERIORATED NATURAL VENTILATION CLOSURE LOCATED ON THE MAIN DECK PORT SIDE OF THE DECK HOUSE._x001C_ SOLAS 74 II-2/25(c)
Condition: Unknown
Due 13 April 1996
Resolved 15 April 1996
Lifesaving
Issued 8 April 1996 Resolved
PROVIDE AT LEAST TWO RING LIFEBUOYS WITH SELF IGNITING LIGHTS AND AN EFFICIENT SELF ACTIVATING SMOKE SIGNAL CAPABLE OF QUICK RELEASE FROM THE NAVIGATING BRIDGE._x001C_ SOLAS 74 III/21(g)
Condition: Unknown
Due 13 April 1996
Resolved 15 April 1996
Electrical
Issued 8 April 1996 Resolved
PROVIDE AN APPROVED EXPLOSION PROOF LIGHT FIXTURE FOR USE IN THE BATTERY STORAGE ROOM._x001C_ SOLAS 74 II-1/27(c)
Condition: Unknown
Due 13 April 1996
Resolved 15 April 1996
Accommodation/Occupational Safety
Issued 8 April 1996 Resolved
RENEW AS ORIGINAL DETERIORATED NATURAL VENTILATION CLOSURE TO BATTERY STORAGE ROOM._x001C_ SOLAS 74 II-2/25(c)
Condition: Unknown
Due 13 April 1996
Resolved 15 April 1996
Accommodation/Occupational Safety
Issued 8 April 1996 Resolved
RENEW AS ORIGINAL DETERIORATED VENTILATION CLOSURES LOCATED PORT SIDE ON THE BRIDGE DECK. VENTILATION DUCTS SERVICE ENGINE ROOM._x001C_ SOLAS 74 II-2/25(c)
Condition: Unknown
Due 13 April 1996
Resolved 15 April 1996
Accommodation/Occupational Safety
Issued 8 April 1996 Resolved
RENEW AS ORIGINAL DETERIORATED VENTILATION CLOSURES LOCATED STARBOARD SIDE ON THE BRIDGE DECK. VENTILATION DUCTS SERVICE ENGINE ROOM._x001C_ SOLAS 74 II-2/25(c)
Condition: Unknown
Due 13 April 1996
Resolved 15 April 1996
Fire Fighting
Issued 6 November 1995 Resolved
REPAIR/RENEW DETERIORATED FIREMAIN BRANCHLINE PIPING LOCATED IN STEERING GEAR ROOM. SEE SOLAS 74 AMENDED II-2/21
Condition: Unknown
Due 13 November 1995
Resolved 17 November 1995
Fire Fighting
Issued 6 November 1995 Resolved
PROVIDE ONBOARD INSTRUCTIONS FOR MAINTENANCE AND OPERATION OF ALL INSTALLATIONS/EQUIPMENT FOR FIGHTING AND CONTAINMENT OF FIRE. SOLAS 74 AMENDED II-2/20
Condition: Unknown
Due 13 December 1995
Resolved 5 December 1995
Lifesaving
Issued 6 November 1995 Resolved
repair/replace/renew both keel rails on stbd lifeboat and portside keel rail on port lifeboat. SOLAS 74 amended III/19.2
Condition: Unknown
Due 13 November 1995
Resolved 17 November 1995
Lifesaving
Issued 6 November 1995 Resolved
repair/rplace/renew deteriorated lifeboat exposure cover framework to both port and stbd lifeboats. SOLAS 74 amended III/41.8
Condition: Unknown
Due 13 November 1995
Resolved 17 November 1995
Lifesaving
Issued 6 November 1995 Resolved
REPLACE DETERIORATED BUOYANT LIFELINES TO RING BUOYS. SOLAS 74 AMENDED III/7.1.2
Condition: Unknown
Due 13 November 1995
Resolved 17 November 1995
Construction/Loadline
Issued 6 November 1995 Resolved
REMOVE EXCESSIVE OIL/WATER FROM BILGE IN ENGINE ROOM TO SHORE RECEPTION FACILITY. MARPOL 73/78 AX 1
Condition: Unknown
Due 13 November 1995
Resolved 17 November 1995
Construction/Loadline
Issued 6 November 1995 Resolved
CLEAN/REMOVE EXCESSIVE OIL/FUEL RESIDUES FROM ENGINE ROOM DECKS, CONTAINMENTS, AND MACHINERY SURFACES. MARPOL 73/78 AX.1
Condition: Unknown
Due 13 November 1995
Resolved 17 November 1995
Engineering
Issued 6 November 1995 Resolved
REPAIR/RENEW DETERIORATED AND LEAKING SALTWATER COOLING PIPE (12") FOR SHIPS SERVICE GENERATOR.
Condition: Unknown
Due 13 November 1995
Resolved 17 November 1995
Navigation
Issued 14 August 1995 Resolved
PRIOR TO NEXT ENTRY INTO U.S. PORT REQUIRED PRE-ARRIVAL TESTS MUST BE CONDUCTED AND LOGGED AS PER 33 C.F.R. 164.25.
Condition: Unknown
Due 28 August 1995
Resolved 28 August 1995
Navigation
Issued 14 August 1995 Resolved
MANEUVERING FACT SHEET MUST BE CORRECTED TO SHOW EFFECTIVE MANEUVERING SPEEDS OF BOW THRUSTER PRIOR TO NEXT U.S. VOYAGE.
Condition: Unknown
Due 21 September 1995
Resolved 28 August 1995
Navigation
Issued 11 July 1994 Resolved
PROVIDE NON-SLIP SURFACE OR GRATING IN THE STEERING GEAR COMPARTMENT.
Condition: Unknown
Due 11 July 1994
Resolved 11 July 1994
Lifesaving
Issued 11 July 1994 Resolved
THE PORT LIFE BOAT IS MISSING ONE BOAT HOOK.
Condition: Unknown
Due 11 July 1994
Resolved 11 July 1994
Navigation
Issued 11 July 1994 Resolved
RUDDER ANGLE INDICATOR IN STEERING GEAR COMPARTMENT WAS FOUR DEGREES OFF WITH THE RUDDER ANGLE INDICATOR ON THE BRIDGE.
Condition: Unknown
Due 11 July 1994
Resolved 11 July 1994
Documentation
Issued 13 July 1989 Resolved
A VIO OF 33 CFR 155.820 IN THAT THE VSL DID NOT HAVE A WRITTEN RECORD OF THE DATE AND RESULTS OF THE MOST RECENT TEST OF THE OIL TRANSFER SYSTEM REQBY 33 CFR 156.170.
Condition: Unknown
Due 13 July 1989
Resolved 13 July 1989
Documentation
Issued 11 May 1987 Resolved
33CFR151.25(D) VSL FAILED TO LOG POSITION OF SHIP DURING OIL DISCHARGE OVERBOARD THROUGH 15PPM EQUIPMENT IN OIL RECORD BOOK.
Condition: Unknown
Due 11 May 1987
Resolved 11 May 1987
Navigation
Issued 11 May 1987 Resolved
33CFR164.33(A)(2)(II) COAST GUARD LIGHT LIST FOR THE GULF COAST NOT ON BOARD.
Condition: Unknown
Due 11 May 1987
Resolved 11 May 1987
Documentation
Issued 11 May 1987 Resolved
33CFR155.750(A)(2)(III) OIL TRANSFER PROCEDURES DID NOT HAVE A DISCRIPTION OF AND PROCUDRES FOR EMPTYING THE DISCHARGE CONTAINMENT SYSTEM.
Condition: Unknown
Due 11 May 1987
Resolved 11 May 1987
Navigation
Issued 21 April 1986 Resolved
THE VESSEL DID NOT HAVE A COPY OF INLAND RULES OF THE ROAD ON BOARD
Condition: Unknown
Due 21 April 1986
Resolved 21 April 1986
Navigation
Issued 21 April 1986 Resolved
THE VESSEL DID NOT HAVE A TABLE OF MANUEVERING SPEEDS FOR THE BOW THRUSTER POSTED WIHT THE MANEUVERING INFORMATION
Condition: Unknown
Due 21 April 1986
Resolved 21 April 1986

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.